Laserfiche WebLink
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6, Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load ° O <br />Safe vertical load Safe horizontal load <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />r• TI <br />- • 1 - ; - 1 �• ; FORM do GROUT SOLID <br />O O <br />8F8-1B/1T 8F8-0B/1T 8RF6-0B/1T ;'� • ;�', O N W <br />lk <br />AO © © O O O• O <br />8RF14-16/1T 8RF14-0B/1T 8F16-0B/11T 8F16-1B/1°T ° 15 BAR CONT. <br />© © 8F1216/1T <br />8F20-0B/1 T <br />® "V" LINTEL DETAIL <br />SCALE = N.T.S. <br />60 <br />no <br />00 <br />0M. OM <br />nip,; <br />TYPE DESIGNATION <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @BOTTOM <br />OF LINTEL CAVITY <br />J <br />a <br />Lu <br />8 F 16- B/ 1 T <br />0 <br />z <br />t142 <br />NOMINAL. L QUANTITY OF <br />WIDTH #5 REBAR AT <br />TOP <br />NOMINAL <br />° <br />HEIGHT <br />#S REBAR.(1)RE TTOP ALTERNATE POWERS <br />MIN. (1) REQ'D <br />G ° CLEAR STEEL LINTEL <br />° ° <br />a <br />M.U. <br />#5 REBAR AT TOP <br />° <br />° <br />GROUT <br />MIN. (1) REQ'D- <br />° <br />n <br />° <br />n a� <br />5 REBAR AT <br />= w <br />° O <br />BOTTOM OF <br />F- rn w <br />w 0 y � <br />LINTEL CAVITY <br />U <br />-BOTTOM <br />Ir 0 O Z <br />REINFORCING <br />4 a c7 � <br />'- <br />7-5/8"ACTUAL <br />PROVIDED IN <br />e LINTEL <br />Z o W a <br />a <br />n cr a LO <br />VOMINAL WIDTP__7 <br />(VARIES) <br />:nn <br />1-1/2" CLEAR <br />REBAR AT <br />AS INDICATE <br />MATERIALS <br />c precas rntels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />minimum net area compressive strength = 1900 psi. <br />1. Refer to manufacturer's specifications for installation. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />2. Contractor to provide proper protection of lintel to prevent rusting. <br />7. 270 low relaxation. <br />Refer to manufacturer's specifications. <br />7/32 wire per ASTM A510. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />8. Mortar per ASTM C270 type M or S. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN, IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />applying the cementitiuos coating. See contractor specifications <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP OR <br />SIMPSON MSTAM36 STRAPS EACH STUD ((1) <br />STRAPS EACH SIDE) CENTERED W/ (13) 10d <br />NAILS & (8) Y4"x1 J" TAPCONS OR TITENS <br />*CENTER OF STRAP @ TfWALL TYP. U.N.O. <br />2x8 #2 SYP P.T. BASE PLATE <br />W/ Y2" EPDXY ANCHOR OR Y2" <br />J BOLT W/ MIN. 7" EMBEDMENT @ <br />32" O.C. & 6" FROM EACH END <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE PLAN <br />F T/WALL <br />II <br />IW <br />8" KNOCKOUT COURSE O O <br />W/ (1) #5 CONT. <br />5'-10" LL 13'-0" LL <br />SEE PLAN FOR FILLED CELL <br />SPACING <br />-1 , <br />1 WALL SPLICE DETAIL <br />REVISED: 11/04/19 SCALE: 1" = 1'-0" <br />E <br />MIN. <br />17'-4" LL <br />LINTEL PLAN - ELEV-B <br />SCALE: X"=V-O" <br />C <br />8'-0" LL <br />0 <br />4'-6" LL <br />(D <br />4'-6" LL <br />B <br />MIN. <br />5'-8" LL <br />O <br />N O <br />00 <br />._ <br />W 1 <br />) v <br />0 <br />co <br />i) <br />CJi a Q <br />L . Y C: <br />5 fi O O <br />U _- <br />�_ <br />c ry O W <br />i <br />To the best of the Engineer s knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />H CD <br />W oro <br />H o E co <br />a O M N <br />O N 4 J <br />LL <br />UN CD J <br />0 � LL; cD N 3k LL W <br />Vi cn r` t�- a - W a- <br />N rNo u- Y <br />LL a Lu <br />J = O <br />Z ; O <br />iU cv cp Lr O <br />��m <br />W in � 1j Q Q ¢ <br />co d a <br />Z N coZ of D O <br />ZO 3 U ccO <br />W ❑ ❑ ❑ <br />Z N fo <br />0 0 <br />z co N <br />z o � <br />Q <br />r- <br />rry <br />N Z <br />`o <br />U <br />4--J <br />Um <br />Ow <br />o <br />N � <br />�V) <br />cn <br />1713 U <br />c <br />W <br />J <br />E <br />fO 8 <br />�Ir <br />U o <br />C u) <br />Q � <br />N Oi <br />�Q <br />t m <br />r_ <br />¢ <br />w <br />M <br />� <br />E <br />=o <br />>� <br />Zo <br />Q o <br />w <br />_® <br />❑� <br />o L <br />U❑ <br />d ¢ <br />o Q <br />Z <br />CV <br />w = oo <br />wz <br />c <br />L <br />�Q" <br />C <br />Qo <br />ono <br />12 <br />m� <br />o <br />Zz <br />>z <br />z <br />� J <br />3 <br />m <br />F e <br />f <br />z z <br />a� <br />°o< <br />wLL <br />g° <br />a <br />W <br />O <br />o <br />N z <br />it <br />i3 <br />o <br />wa <br />a � <br />za <br />3 <br />�� <br />'M <br />J <br />Om <br />c� <br />N <br />L <br />LO <br />C0 'i <br />T <br />=3 T <br />Y <br />T <br />0 m <br />O <br />CD <br />LO <br />(may <br />Q N <br />r <br />ai <br />N <br />LO N <br />0 <br />z <br />rEo <br />z <br />N <br />E t- <br />c <br />d <br />0 <br />U _J Q O <br />_J <br />JOB <br />NO: 22-02365 <br />SCALE : AS NOTED <br />SHEET NO. <br />7 <br />