Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />177_ w <br />16GAx1-1\2" LONG (3/4"-1" CROWN) 8 { <br />STAPLES @ 6" O.C. VERT BETWEEN MAX 1 I 16GAx1-1/2" LONG (3/4%1" <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O O O <br />5'-0" Q - <br />0 <br />STUB -OUT FOR O 1'-0" o ;n <br />GAS METER 0 <br />0 0 <br />CV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />1V-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6A <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />V-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />1 T-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />FILL CELLS STD. 90' HOOK r— BOND BEAM <br />SIMPSON MGT <br />w/(22)10d <br />w � NAILS TYP. GIRDER TRUSS <br />¢ STD. 90° CONT. #5 <br />BOR T. #5 I HOOK 77- 1 <br />BAR 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />I� Q �CONT. BASE PLATE <br />BEARING COLUMN �y PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION J �, TJI TO BE CUT TO ALLOW <br />FOR BLOCKINGlTJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />\�\ TJI PER PLAN <br />OTHERWISE SOLID <br />\, BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />DOUBLE JOIST CONSTRUCTION SECTION @ INT. BRG. WALL <br />Backer and Filler Block Dimensions (Not required if both loaded equally from above) N.T.S. <br />BCI®Joist Backer Block . + <br />Thickness Filler Block Thickness Filler blocking # / � 1/8" min. 2" min. <br />Thi <br />2" max. } „ <br />max. � -Web S <br />Series , 4_tl_ffener Fastener Schedule <br />1/8" gap Small gap - <br />3/4" or 7/8" Joist Bearing Location <br />5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x _ ' i <br />p Series_ Depth End Intermediate . <br />®.9-1/211 <br />2-8d2-8d_ <br />1-1/8" or two 1l2" , / BCI 5000s 11-7/8" 2-8d 3-8d <br />6000s 1.8/1.7 wood panels 2 x _ + 518" or 3/4" wood panel 14" 2-8d 5-8d <br />Clinch <br />9 1/2_ 2-8d 2-8d <br />1-1/8" or two 1/2" when nails BCI 6000s®111 7 e 24d 3-8d - <br />wood panels <br />p 1 BCI6500s 16 2-8d 5-8d - 6500s 1.8l1.7 p 2 x _ + 5/8" or 3/4" wood panel 1) Support back of web during nailing to prevent damage to possible ® 16" 1 i - - <br />2-8d 6-8d i <br />1-1/8' or two 1!2 2 g obk solid betweenjoistsfor full length of span. <br />g % \ -..^ 11 7/8 2 8d 3 8d <br />60 2.0 2 x _ + 5/8' or 3/4" wood panel g _ BCI 60s� 1 2-8d 5-8d <br />wood panels 2x4/ I I ood/OSB web stiffener \ 2" _ <br />117/8" 316d 6-8d <br />1 916 2 Sd <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. yy„ BCI 90s 14" T5 16d 3-16d <br />902.0 2 x —lumber Double 2 x _lumber 4' max. O 5 16d <br />4) Place joists together and nail from each side with 2 rows of 10d nails R - <br />required when indicated or 16" 6-16d 6-16d <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION-Birdsmouthcuts. N.T.S. <br />Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) �l <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls / <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />Odnails require additional consideration. <br />SECTION @INT. BRG. WALL— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />CD ❑ CD <br />6A 1Y2" ROUND HOLE MAY 6 6" <br />CUT HOLES DO NOT <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1)/2' <br />[{ <br />%�. �0..�.J1d,+�.iMsi:,e-�il� _a'a�.�-x����i�_rE�;�.� <br />$tr r.»�iG�.=a-N��w����.- <br />.'=-��v3'• <br />«.-'�aw�-.�v��,�-�+4$� <br />�.�'�� <br />-`D�-z2.,�ri� <br />��g�k��y <br />�?M1{„'r...."rt <br />z�f�..�4S�6� <br />.3..� 4.t�.� <br />_✓1 <br />�i¢��}�-�: <br />`...R.. 1 <br />��c <br />Del1*3 <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Yz" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />5/8" 0 <br />THRU <br />BOLT <br />Ice <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />TI I I —II I IfI I ITI I I_ —I I I — <br />\stall tight to top flange. <br />4 A: <br />SLEEVE THRU STEM <br />Joist hanger /j ' v� <br />SEE PLAN FOR •• • . •.; .• , <br />FOUNDATION INFO a' ' d' <br />STEM FOUNDATION <br />Filler block. <br />GRADE REINF. SEE PLAN <br />Nall with <br />P 10-10d nails. <br />d <br />Backer block required where top <br />b <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />I —II ll I l i lI I I I r_I <br />1/4%2" gap <br />— ✓L1 <br />✓ <br />-- - Backer Block- -� <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />l r % ✓ 0.6 X Joist <br />o'✓ i depth <br />o ✓ x✓ <br />I -JOISTS BUCKETS <br />N.T.S. <br />i_ <br />' (2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />-�� LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" . • •� REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" v <br />CENTERED @PIPE <br />PENETRATION <br />t Q a <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />y`— SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />as L <br />Ill III <br />-� \ . a <br />d G <br />A <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />N W a 0 <br />N - <br />00 �J <br />W T <br />(n <br />i <br />d' M <br />C <br />c� O O <br />: U = <br />, <br />0 L <br />CL O <br />.1'' <br />v <br />J Q i <br />S 910 to <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />U) <br />,. l aLU <br />8E <br />Q O <br />N 12 -I <br />LL <br />5Y10 _J <br />C j t) co N # LL W <br />4) N r- r, -V LL w a- <br />0 yrN,0 <br />° Y <br />a m U a W <br />� <br />a° t9 J 0 <br />Z r 0 <br />13 <br />m C:, <br />4Lu <br />-X S'�Nm m O <br />m <br />W inn2C O <br />a <br />Z N M Z X D 0 <br />OU U� vVi <br />1-100 <br />0 <br />z C> <br />z o <br />armm <br />a <br />co <br />N zC3Qj CD o <br />LL <br />N <br />W <br />—� <br />O w o <br />U, Y <br />w <br />= <br />L 'D <br />U o <br />c in <br />�Q <br />co <br />CO <br />Jz <br />w <br />co <br />M <br />o <br />Z <br />4 <br />M <br />U_ <br />aE <br />o <br />za <br />> <br />Zo <br />a® <br />'T m <br />� <br />a� <br />w¢ <br />�° <br />Z0. <br />o <br />N <br />~ <br />Qz <br />aSo <br />&a <br />wz <br />� � <br />� <br />C <br />ox¢ <br />U <br />mE <br />p <br />O� <br />Z H <br />z <br />_J <br />J <br />m <br />< O <br />Q w <br />E <br />to <br />z <br />Zo <br />a <br />�w <br />W <br />U <br />o <br />CID <br />;o <br />zl¢T�U <br />i <br />E2 <br />> co <br />J <br />Orn <br />M <br />m <br />0 <br />L <br />LO <br />1..� <br />U <br />m <br />i-+ <br />i-+ <br />O <br />C14 <br />.0 <br />N <br />Q N <br />C'M <br />E <br />t <br />E ' ^ '7 <br />L <br />0 <br />M <br />z <br />7 / <br />E ,f— N <br />a <br />E <br />0 � Q cc <br />JOB <br />NO: 22-02365 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />