My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6313 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6313 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 12:38:55 PM
Creation date
2/18/2025 3:25:42 PM
Metadata
Fields
Template:
Building Plans
Street #
6313
Location
Beverly Hills Dr
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KNEE WALL WITH <br />1x8 CAP &CASING OR <br />�42" <br />36" RAILING <br />36" <br />D <br />3/4" PLYWOOD <br />DECKING <br />16 _ <br />15 <br />14 <br />_ _ <br />13_ <br />12' PRE-ENG FLOOR <br />TRUSS <br />11_ <br />10 1x TREAD (TYP.) -� <br />3/4" PLYWOOD <br />9 1 <br />DECKING <br />8 <br />�` "'ram <br />1x RISERS (TYP. - <br />2x6 LANDING----,,, <br />\ r` <br />6 <br />2x4 FRAMING <br />\ 1 <br />5 42" KNEE WALL WITH <br />\� <br />4 1x8 CAP & CASING OR <br />3 � � 36" RAILING <br />2 2x4 THRUST <br />/I BLOCK <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />.yN <br />CONT. HANDRAIL <br />36" H. CONT. <br />GRASPABLE RAILING RETURN TO <br />WALL DETAIL <br />- - - B SCALE: NTS <br />2x4 THRUST <br />BLOCK 50 <br />(3) 2xl2 00 <br />STRINGERS 1 <br />3/4" PLYWOOD D2 -� <br />DECKING TYP. @ 0(:E) <br />6 <br />2x6 LANDING CORNERS (2) 25-SH D2 <br />2x4 FRAMING I EGRESS <br />TYP. STAIR SECTION <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />than 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />11/2 inches between the wall and the handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />Required guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />riches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />sphere 4 inches in diameter. <br />nder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />ith 1/2-inch gypsum board. <br />), SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1, <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM OI <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENE <br />LANDING FOF <br />STRINGERS l <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1 /4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />1 <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />--------- GG=T'- <br />MASTER <br />BEDROOM <br />8'-0" FLAT CLG <br />CARPET <br />MJ4068 6 <br />B.F. <br />- - - - - - - - - - - - <br />R/SH <br />" 4'-8" <br />M <br />in <br />16 42" H 1/2 WALL <br />OR RAILING PER <br />15 , SPECS <br />13 <br />12 <br />11 TECH <br />CENTER <br />10 <br />T-11" 9 T-3" <br />_ 8 <br />7 ----- <br />6 <br />140C REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />Opening and penetrations through walls or ceilings separating the <br />BEARING WALL SCHEDULE <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />HEIGHT STUD SPECIES SPACING <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />R302.5.1 Opening Protection <br />FURRING AT 16" O.C. <br />Openings from a private garage directly into a room used for <br />SPF #2 <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />sleeping purposes shall not be permitted. Other openings between <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />the garage and residence shall be equipped with solid wood doors <br />8'-0" 2x4 SYP #2 16" O.C. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />SPF #2 <br />9'-0" 2x4 SYP #2 16" O.C. <br />RECESS. REFER TO MASON'S SCOPE FOR <br />R302.5.2 Duct Penetration <br />RECESS WIDTH. <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />SPF #2 <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />separating the dwelling from the garage shall be constructed of a <br />(*) <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />2x6 SYP #2 16" O.C. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />nonmetallic class 0 or classl duct board, or other approved <br />40' PRODUCT LINE - MIN. 48" x 64" <br />material and shall not have openings into the garage. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />50'PRODUCT LINE -MIN. 48" x 76" <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />R302.5.3 Other Penetrations <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />Penetrations through the separation required in Section R302.6 <br />16'-1" 2'-4" @ 12" O.C.' <br />shall be protected as required by section R302.11, Item 4. <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />*' WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />R302.6 Dwelling/Garage Fire Separation. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS" <br />The garage shall be separated as required by Table R302.6. <br />O(D <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />1/2 33 SH D2 <br />EXTERIOR WALLS <br />TEMP <br />4-SH <br />71 <br />O CCn4, <br />� <br />1668 <br />B.F. <br />2,�„5 6„ <br />TEMP. GL. <br />4 8 M. BA <br />I <br />H I N o <br />-- -- 8'-0" FLAT C <br />G I I <br />ENCL. ON 42" <br />R/SH TILE- <br />HIGH KNWL. <br />48x42 ' <br />- - - <br />-- RECESS <br />T-0" SHOWEF <br />3 <br />D2 <br />3'-2" 0„ TB d <br />F �� -i <br />I <br />TILE TO <br />SIM. w/ (1) <br />T A.F.F. <br />MSTAM36 <br />` J <br />3"x22" ----- <br />I __ <br />I= <br />@BASE <br />TTIC I C <br />la <br />CCESS 8'-0" F T CLG <br />00 <br />i C� <br />N <br />CAR T <br />M <br />O <br />2468 <br />II `- <br />TP <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />CD <br />BEDROOM 2 <br />- - 8'-0" FLAT CLG <br />CARPET <br />4" 12'-2" = Lu <br />N w D2 0 <br />5068 <br />B.F. <br />J <br />GO <br />NA <br />S6 <br />N <br />TYP. @ 2 <br />STORY.SEE <br />o <br />JJ/S6 FOR <br />� <br />7n.-913 <br />STEMWALL <br />OPT. <br />3' 4" 5'-7" <br />0o ti��6 <br />T H <br />O <br />I <br />M _ 8 0" FLAT CLG <br />[LTLAEFT <br />.F. <br />2868 TALE <br />Jt,TfH <br />CO BEDROOM 3 D2 <br />8'-0" FLAT CLG SIM. w/ (1) <br />G.T. CARPET MSTAM36 <br />------------@BASE11'-2" 11'-6" -I - - - - - - <br />------- G.T. - - I------� <br />)b o � ti I = ' SIM. w/ (1) <br />r iri I a ( MSTAM36 <br />BEDROOM 4 @BASE <br />8'-0" FLAT CLG I 3 <br />CARPET I D2 <br />I <br />o =I <br />cnI 00 <br />(D� <br />m I m 1/2 33 SH I <br />I H1 e 6 I <br />I D2 I <br />25-SH 25-SH <br />9 I <br />GRESS EGRESS D2 <br />O D2 22 <br />H1 B D1 H1 B I <br />I <br />13-6" 2-11" 2'-10" 2' <br />to <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I--------------------------------------- <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE"C" <br />DA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />O <br />SEE SN SHEET HO SEE SN SHEET <br />� t�Q MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 2 X 251 <br />S.H. <br />13 <br />20 X 38 g <br />181 X 371 <br />S.H. <br />14 <br />20X508 <br />182'X50 <br />S.H. <br />15 <br />20 X 63 <br />18 2 X 621 <br />S.H. <br />16 <br />20X72 <br />182X711 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 3 <br />S.H. <br />1H3 <br />271/4X383 <br />26x37 <br />S.H. <br />1 H4 <br />27 a X 508 <br />26 x 50 <br />S.H. <br />1 H5 <br />271 X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 a X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 s <br />36 2' X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 8 <br />36 4 X 50 <br />S.H. <br />25 <br />37 a X 63 <br />36 ' X 62 1/2 <br />S.H. <br />26 <br />37 a X 72 <br />36 z X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2'WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 25 <br />S.H. <br />33 <br />54 X 38 g <br />521 X 37 <br />S.H. <br />34 <br />54 X 50 8 <br />52 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 2'X 62 z <br />S.H. <br />36 <br />54 X 72 <br />52 ' X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN - B <br />SCALE: /4"=1'-0" <br />N <br />a o <br />N <br />D <br />00 <br />_ ,> <br />w <br />IJ <br />. i <br />_ c <br />c•', "= <br />C <br />CL• Q <br />O O <br />'JCL <br />-W <br />JV <br />N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />H <br />Q <br />0 <br />o E c <br />O M 8 N r * <br />V <br />c c# U- <br />Q <br />.7�0 N LL. W <br />M <br />Oq <br />U) P- a � ut a <br />v u a Y <br />LU <br />LL LL a <br />Z <br />J 0 <br />�_�O <br />W <br />r m o O~ W <br />W <br />0 <br />W <br />LL= <br />00 Z 2 N Q <br />N M <br />Z <br />O 3 U � (n <br />.: W <br />❑❑❑ <br />z N M <br />- o g <br />z <br />z � � <br />Q <br />J - <br />M <br />J <br />(3)C <br />�- <br />o <br />r>3t/Q <br />w <br />Q <br />V <br />O-� <br />w S <br />to <br />�NU) <br />= ~ <br />A <br />U <br />w m <br />i <br />J E <br />U <br />Q <br />soo <br />o <br />co <br />w <br />Z <br />M <br />U_ <br />OZ <br />a <br />� <br />�E <br />o <br />wo <br />ZZo <br />o0zN <br />r� <br />°w¢ <br />E V <br />aO <br />Z <br />t"- � <br />_ <br />� <br />O ro <br />KO <br />a�Z <br />w =o <br />JU <br />wz <br />N t <br />w� <br />� � <br /><o <br />Z`�crzz <br />-� <br />maw <br />Z <br />Cn <br />3 <br />¢F <br />oe <br />Z <br />ao <br />�w <br />W <br />>, <br />T <br />U <br />¢ E <br /><o <br />I <br />aE <br />_0 <br />T, <br />o <br />Q <br />wa <br />�° <br />a <br />,-I- <br />zZ <br />0 <br />2 O <br />i <br />` <br />>M <br />J <br />Co� <br />c� <br />L <br />co <br />T_ <br />:3 T <br />i� <br />Y <br />^ <br />LL <br />r^ <br />V l m <br />O <br />o <br />O <br />� <br />N <br />� <br />N <br />E <br />�' <br />cLO <br />� <br />CV) <br />Z <br />m <br />Z <br />E <br />T_Cc <br />N <br />c <br />a <br />U <br />q p <br />_J <br />JOB <br />NO: <br />22-02365 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.