Laserfiche WebLink
�(TYP) SEE ELEV. <br />SIMPSON SP2 w/ (12)1Old <br />NAILS AT EACH STUD <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2) 16d TO <br />TRUSS BELOW <br />(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />(2) 2x HEADER TO SIT <br />2x6 ! 2x8 WALL BEYOND FLUSH TO THE OUTSIDE <br />STANDARD 3" DIA. TEE <br />SEE PLAN FOR HEADER SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />CONNECTION <br />SCREW OFF CAP (3" DIA.) <br />2x DEAD WOOD @ MID <br />FOR CLEAN -OUT <br />POINT w/ (3)12d <br />MIN. EXTENSION FROM <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />7 5/8" 8" j7 5/8" 88" <br />I I <br />SOLID AREAS ARE ❑ <br />7 5/8" 8" <br />DOUBLE 2x TOP TONEAILS SPACED STEEL AND GROUT <br />EXTERIOR FACE OF BLOCK ❑ ❑ ❑ <br />EVENLY " WALL IS 1 1/2MAXIMUM <br />PLATE INTERIOR ❑ . ❑ <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL <br />FACE OF BLOCK WALL IS 21/4" <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />VARIES 2x BOTTOM PLATE W/ (1)10d @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL <br />SCALE: N.T.S. \ S4 / <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" 0/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2X4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />!I 2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />(3)10d TOENAILS T&B <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />++ STUD W/ (3) 10d NAILS <br />1/2" EXTERIOR GRADE SHEATHING —� <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)10d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K,O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90" HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERAL NOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />—ROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />TO DRAIN C- DOOR OPENING DOOR OPENING <br />EXTERIOR � ❑ <br />F111 <br />WALL CLEAN -OUT A WALL ❑ ❑ ❑ <br />SCALE: N.T.S. S4 ❑ ❑ ❑ <br />1ST COURSE 2ND COURSE 3RD COURSE <br />REFER TO WINDOW PRODUCT APPROVAL MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE <br />SHEETS FOR INSTALLATION INFORMATION BY COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOOR JAMB WALL IS TO BE <br />MANUFACTURER. WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />TYPICAL SECTION THRU WINDOW g MASONRY LAYOUT D <br />S4 SCALE: N.T.S. S4 <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/(l)#5 FOR CONCRETE PLACEMENT 7 <br />d <br />° <br />c c <br />d <br />a e e <br />a d <br />0 <br />8 STD. WHOOK 8" <br />BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />EllLINTEL <br />NOTES: <br />J FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR &DIRECTLY ABOVE THE LINTEL. <br />O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />U3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" <br />FORM CONCRETE INSET TO <br />CREATE A SOLID BASE FOR <br />1/2"X9 1/2" PLYWOOD BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />J <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION <br />GARAGE ENTRY FORM DETAIL <br />2x6 MOUNTING BASE <br />SCALE: N.T.S. <br />�8x8x16 C.M.U. <br />GARAGE DOOR TRACK MOUNTING BRACKET <br />GARAGE DOOR ROLLER GARAGE DOOR TRACK <br />CONNECTION ASSEMBLY <br />GARAGEFLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />a n <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B E <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />P <br />SHED FORWARD THIS DRAWING. <br />S4 <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />ram/ <br />S�cFpC�OOPL <br />2x CRIPPLES @ —� <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2X8 WALL) <br />10d NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING —Ot <br />VERTICAL JAM <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />W/MOUNTING ANGLE <br />FOP <br />a <br />IARAGE <br />OOR <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK rK <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />SIZE <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'- 4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />`--(2) 2x HEADER SEE PLAN <br />• INTERIOR HEADER: <br />S4 <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER <br />EXTERIOR HEADERS: <br />ONLY <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />' <br />2x STUDS TYP. <br />00 <br />OR <br />SIMPSON HTT4 TYP. <br />Op <br />U.N.O. SEE N/S4 <br />HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE <br />BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL Q <br />SCALE: N.T.S. SLI <br />SIMPSON SIMPSON <br />SP4 SP2 <br />2X STUDS @ 24" O.C. <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />4 <br />LINTEL <br />12 <br />SEE ELEV. <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM <br />C. 926 APPLY 3 LAYERS W/ <br />TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER <br />1/8" THICK OVER WATER <br />RESISTIVE BARRIER <br />SIMPSON SP2 w/ (12)10d <br />NAILS AT EACH STUD <br />TRUSS BOTTOM CHORD OR 2x4 <br />CRICKET AS <br />BLOCKING W/ 2-16d TOE NAILS <br />1/2" EXTERIOR GRADE SHEATHING <br />@ EACH END <br />FASTENED TO TRUSSES WITH 8d <br />REQUIRED <br />COMMON WIRE NAILS @ 4" 0/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING ( ) <br />v <br />O/C FIELD24 <br />2x TOP PLATE <br />2X4 PT STUDS @ 16" O.C. <br />2-16d NAILS @ 24" O.C. OR <br />(2) 2X4 PT STUDS UNDER HIP <br />EQUAL TO TRUSS BOTTOM <br />CARRIER/GIRDER TRUSS <br />= _= <br />CHORD OR BLOCKING <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />2x STUD @ 24" <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />O.C. MAX, <br />PROVIDE P.A.F. NAILS OR <br />IN KO BLOCK AT EA, STUD <br />MAIN SPAN <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />MOISTURE BARRIER <br />ROOF TRUSS <br />SEE A/S3 FOR <br />STAGGERED FROM BOT. <br />�/M <br />UPLIFT CONNECTOR <br />REINF. INFO. <br />PLATE TO CONCRETE <br />8"X8716" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90' HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY WALL DETAIL <br />SCALE: N.T.S. <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12) 16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE -7 /_,�NAILS TOTAL) EA. SIDE OF <br />48-4PLICE STAGGERED <br />N. <br />10d @ 8" O/C <br />ATTACH ALL <br />EXTERIOR STUDS <br />W/ (4)16d TOENAILS <br />TO P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />OVER STUD <br />AT LEAST 4'-0" LONG. TYPICAL <br />TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. ��4 <br />F= 2240 LBS <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 <br />�SIMPSON SIMPSON <br />SP4 SP4 <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL <br />SIMPSON SP4 <br />2X TOP PLATE <br />OVERLAPPING <br />10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />SPF) <br />(3075# SPF) <br />3 (4565#SPF) <br />i (5645# SPF) <br />i (6970# SPF) <br />)S (9335# SPF) <br />N. 8" <br />PDXIED A.T.R. <br />I; & NUT <br />'OXIED A.T.R. <br />I & NUT <br />OXIED A.T.R. <br />L& NUT <br />ROOF TRUSS ABOVE <br />F 2X BLOCKING <br />2X81P.T. BOTTOM P I ATE <br />C <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />SIMPSON SIMPSON C (MIN. (2) PER BOTTOM PLATE) <br />SP4 SP2 SIMPSON C <br />SP4 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGERED <br />1 NA NA NA TRANSOM FRAMING <br />0 o BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" L PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />G <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"xl0" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY / 1 <br />SCALE: N.T.S. <br />.0 <br />N ' -) I`` O <br />-- � a <br />-91 <br />-C <br />d ANY <br />01 mo d. <br />-d� <br />(D M <br />_3 > .' <br />E <br />M N 0.:_ 0 <br />C: <br />>a — <br />votittle/ <br />�� �� <br />0 <br />4c�Y <br />. <br />G <br />•N <br />N', d 1p i <br />"11yY0(�Se�ION� <br />`'�.e�/etp�lfi�s4t <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />ti <br />11- W t o 'o <br />Q U N <br />O N J <br />Q '3 G oo cc (n LL w <br />Ewa <br />Co Q NM V � to N <br />o <br />_ <br />Zfx <br />a O' w <br />0 2E M M < <br />r <br />W a <br />oo Z N MZ a 0 <br />ILW <br />Z O U Uco <br />W <br />M � <br />O o <br />Q <br />a <br />n <br />M <br />N z <br />C9 __ <br />4--J cr, - <br />! <br />U 2 <br />O W C. <br />-a>t) S <br />�,.. <br />U <br />_ E <br />L <br />Q N <br />�� <br />o <br />W <br />0! <br />Cl) <br />CM <br />¢ <br />z <br />4 <br />zo <br />>� <br />4Q2 <br />M_E <br />o <br />U <br />❑a <br />XU <br />�¢ <br />UK <br />DOU <br />oz <br />z <br />N <br />¢� <br />�a <br />�z <br />w2 <br />L <br />fu <br />cj C <br />- C <br />¢ Z <br />o o <br />m O <br />oE <br />ZrrZ <br />Z <br />uJm <br />Q W <br />zz <br />N <br />~Og <br />Z <br />s0 <br />fl- <br />W <br />R <br />N W <br />W <br />H <br />CDu <br />� S <br />a <br />(O <br />V' <br />i ¢ <br />0 3 <br />E <br />>co <br />__J <br />0 <br />tm <br />CM <br />/}� <br />`v V <br />T <br />:3 T <br />v / ca <br />1 <br />0 <br />04 <br />N <br />Q <br />Q T <br />T <br />ai <br />E <br />w N <br />co N c� <br />o <br />Z <br />Z <br />E T y <br />E <br />m <br />c <br />a <br />U Q p <br />JOB <br />NO : 22-02363 <br />SCALE : AS NOTED <br />SHEET NO. <br />S4 <br />