GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed L/360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6_ Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load G 1 .O <br />Safe vertical load Safe horizontal load - <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />8F44 1B/1T8F40 1B/1T 8RF400B/1T 8F321B/1T <br />FORM k GROUT SOLID <br />N <br />O � W <br />U <br />O 15 BAR CONT. <br />8F12-1 B/1 T <br />O <br />'Y LINTEL DETAIL <br />SCALE = N.T.S. <br />E <br />E <br />� <br />Kamm <br />TYPE DESIGNATION <br />#5 REBAR <br />MIN.(1)REQ'D <br />AT TOP <br />ALTERNATE POWERS <br />F=FILLED WITH <br />GROUT / U = UNFILLED <br />1/2" <br />CLEAR <br />STEEL LINTEL <br />n ° <br />R=RECESSED <br />QTY. OF #5 <br />° ° <br />REBAR @ BOTTOM <br />° <br />OF LINTEL CAVITY <br />X <br />G ° <br />.M.U. <br />#5 REBAR AT TOP <br />J¢ <br />w <br />° ° ° <br />MIN. (1) REQ'D <br />1-1/2" CLEAR <br />8 F 16- B/ 1 T <br />H <br />a <br />J <br />z <br />° <br />Z <br />a ° <br />GROUT <br />J <br />tNOMINAL.QUANTITY OF <br />5 REBAR AT <br />L. CO ~ ¢ <br />C.M.U. <br />WIDTH #5 REBAR AT <br />° O <br />BOTTOM OF <br />a in - <br />TOP <br />LINTEL CAVITY <br />rn U <br />o W <br />NOMINAL <br />"*-BOTTOM <br />a it d o z <br />HEIGHT <br />REINFORCING <br />C < C7 � <br />Cr <br />7-5/8"ACTUAL <br />e PROVIDED IN <br />Z LL o w n <br />8" NOMINAL WIDTH <br />LINTEL <br />¢ _ - Cr i'- <br />#5 REBAR AT BOTTOM <br />(VARIES) <br />U) � it a <br />AS INDICATED <br />MATERIALS <br />16 GAUGE POWERS <br />cTf- precaslTntels = 3500 psi. <br />STEEL BOXED LINTEL <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />ONLY IF NOTED ON LINTEL PLAN <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade <br />1. Refer to manufacturer's specifications for installation. <br />Prestressing strand per ASTM A416 grade <br />2. Contractor to provide proper protection of lintel to prevent rusting. <br />7. 270 low relaxation. <br />Refer to manufacturer's specifications. <br />7/32 wire per ASTM A510. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />8. Mortar per ASTM C270 type M or S. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />applying the cementitiuos coating. See contractor specifications <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />2x8 92 SYP STUDS @ 8" O.C. W/ (2) USP OR <br />SIMPSON MSTAM36 STRAPS EACH STUD ((1) <br />STRAPS EACH SIDE) CENTERED W/ (13) 10d <br />NAILS & (8) Y4"x1 J" TAPCONS OR TITENS <br />*CENTER OF STRAP @ T/WALL TYP. U.N.O. <br />2x8 #2 SYP P.T. BASE PLATE <br />W/%" EPDXY ANCHOR ORY2" <br />J BOLT W/ MIN. 7" EMBEDMENT @ <br />32" O.C. & 6" FROM EACH END <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE PLAN <br />T/VVALL <br />8" KNOCKOUT COURSE <br />W/ (1) #5 CONT. <br />- -SEE PLAN FOR FILLED CELL <br />-� SPACING <br />1 WALL SPLICE DETAIL <br />REVISED: 11/04/19 SCALE: 1" = V-0" <br />O <br />8'-0" LL <br />O <br />4'-6" LL <br />O <br />4'-6" LL <br />(DMIN. <br />5'-8" LL <br />O O <br />13'-0" LL 5'-10" LL <br />E <br />MIN. <br />17'-4" LL <br />LINTEL PLAN - ELEV-B <br />SCALE: Y4"=1 '-O" <br />1 o <br />r` 7 <br />® <br />c > >G <br />n <br />-r„ <br />(_� ` <br />`v <br />t.� <br />Y r <br />W p O O <br />Q <br />J c: U <br />63 L <br />> <br />] 2 - W <br />C, <br />�• °• <br />V <br />1 <br />1� <br />. <br />JIOt-!P�' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />WCD <br />W <br />E 1 w <br />Q <br />O M8 N 0 <br />O N J <br />ci <br />Q <br />ONCN <br />7 a0 N LL W <br />N <br />VJ <br />N W LL a- <br />° Y <br />�rNiv <br />a LU <br />Z <br />JLLLL <br />o <br />- 0 Y <br />L2 O O O W <br />'m N m K O <br />W <br />m _JW d <br />) ¢o <br />IL Z <br />� � Z 0- D O <br />a <br />N Q U � 0 <br />°" <br />Z <br />'.` W <br />o00 <br />M � <br />Z N � <br />o g <br />Z <br />N <br />z � � <br />J <br />a � <br />N <br />N <br />M <br />Z <br />U o <br />U <br />Ow <br />N <br />C N <br />Vvi <br />= - <br />U � <br />w m <br />¢ <br />N <br />I� <br />M <br />V7 <br />M <br />Z <br />J <br />E <br />� <br /><� <br />Q a <br />E <br />w� <br /><S <br />z® <br />x0 <br />¢ <br />0° <br />ZO <br />z <br />woE <br />Zw <br />N <br />N i <br />wo� <br />ao <br />mf <br />sU <br />o <br />z � <br />J <br />m,Z <br />° <br />Z <br />Z <br />Cn 3 <br />d <br />op <br />LLa <br />Z <br />Z <br />5Z, <br />mw <br />W <br />o <br />� <br />o <br />w¢ <br />=r <br />�o <br />CZ) <br />it <br />OU <br />V <br />z1 < <br />3 <br />0O <br />0 <br />= <br />>M <br />Om <br />�' <br />cc <br />cc <br />0 <br />N <br />L <br />d. <br />co <br />N <br />T <br />U) m <br />cfl <br />O <br />o <br />0) <br />N <br />`� <br />T_ <br />Q <br />T <br />ci <br />m <br />N <br />N <br />o <br />Z <br />Z <br />E NCU <br />N <br />a <br />U � <br />Q p <br />� <br />JOB <br />NO : <br />22-02370 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />