Laserfiche WebLink
42" KNEE WALL WITH �\ <br />1x8 CAP & CASING OR <br />36" RAILING �1 <br />36" H. CONT. <br />GRASPABLE __@) 7 <br />RAILING <br />3/4" PLYWOOD <br />DECKING 16 <br />15 <br />14 -- <br />13 <br />PRE-ENG FLOOR 12 <br />TRUSS 11 <br />1x TREAD (TYP.) 10 <br />1 9 <br />8 <br />M"la 1 <br />2x4 THRUST <br />/ 1x RISERS (TYP.)C? BLOCK-\ r I 7 <br />bo - / 6 -- <br />v <br />STRINGERS 42" KNEE WALL WITH ( 5 <br />1x8 CAP & CASING OR 4 <br />3/4" PLYWOOD 36" RAILING 3 <br />DECKING <br />Y <br />Cl) 2x6 LANDING 2x4 THRUST 2 <br />BLOCK 1 <br />2x4 FRAMING <br />TYP. STAIR SECTION <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />than 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />11/2 inches between the wall and the handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />equired guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />nches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />sphere 4 inches in diameter. <br />nder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />[with 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUI <br />@ END OF LAN <br />BELOW HDR. B <br />STANDARD (3; <br />STRINGERS w <br />SIMPSON A35 <br />MP34 CLIP TO <br />FLOOR SYSTE <br />LANDING FRA. <br />(2) 2x HD <br />REQ'D @ <br />LANDING <br />STRINGE <br />CONNEC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />CONT. HANDRAIL <br />RETURN TO <br />*VVHLUt I HIL <br />SCALE'LNTS <br />3/4" PLYWOOD <br />DECKING 2'-4" <br />-2x6 LANDING <br />2x4 FRAMING <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS -\ <br />3 <br />D2 <br />SIM, w/ (1) <br />MSTAM36 <br />@ BASE <br />U) <br />to <br />Lu <br />C?D2 N w <br />'v10 <br />H 1").( AD <br />�-A <br />TYP. @ 2 <br />STORY. SEE <br />JJ/S6 FOR <br />STEMWALL <br />OPT. <br />O H1 <br />6 <br />1/2 33 SH <br />4 <br />D2 TEMP <br />4-SH <br />I <br />o O <br />BPI <br />1668 <br />SPECS. I I _ <br />B.F. <br />I v <br />4'-4" <br />M <br />LJ <br />BATH <br />246 <br />A 8' <br />0" FLAT CLG <br />TILE_ <br />R/SH <br />48x42 <br />_--- <br />RECESS' <br />TB <br />r <br />SH011�ER <br />`t <br />0 H1 <br />O(2) SH <br />EGRESS <br />LO <br />CV <br />6-7" <br />- -G-T---------- <br />N <br />"r <br />7-0 <br />2 <br />-3-�L <br />TILE T - <br />I 36" x 2; <br />7' A. . F. <br />I <br />I I ATTI <br />( <br />=I <br />L - - - - - ACCEE <br />ti <br />18'-0" <br />F T CLG <br />ih <br />• <br />C RPET <br />n TP <br />1 <br />2468 <br />BEDROOM 2 <br />F-0" FLAT CLG <br />CARPET <br />5068 <br />B.F. <br />--------------- <br />R/SH <br />-4" <br />12'-10" <br />OWNER <br />SUITE <br />8'-0" FLAT CLG <br />CARPET <br />4068 <br />B.F. <br />- - - - <br />- - - - - - <br />RIS <br />" 4'-8" 1 4" <br />' <br />ih <br />rn <br />42" H 1/2 WALL <br />OR RAILING PER <br />SPECS <br />19 <br />CV <br />0 <br />12 <br />TECH 11 <br />CENTER I <br />10 <br />T-3" 9 <br />1 8 <br />I <br />- ---- 7 <br />6 <br />D2 BEDROOM 3 4-SH N o <br />-1 <br />SIM. w/ (1) T-0" FLAT CLG <br />CARPET G.T. <br />MSTAM36 --_-_ -t-4" <br />@ BASE1 V-6" <br />I G.T. <br />00 <br />OP <br />MSTAM36 OI I v m <br />@BASE BEDROOM 4 <br />3 ( I 8'-0" FLAT CLG <br />D2 G.T. <br />T I CARPET <br />I <br />I00 = o <br />1 1/2 33 SH Q 7 <br />v m I My <br />I D1 <br />M I 25-SH 25-SH <br />B-SH <br />EGRESS 9 EGRES <br />D2D<O D, I <br />I-•---------- <br />5'-8" <br />10" L 2'-11" <br />13-6" <br />Pan <br />T 25'-0" l <br />i I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I ---------------------------------------I <br />1 <br />D2 <br />TYP. @ <br />CORNERS <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />O� <br />1 <br />L1 <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />140C REV 10.1.20 CAB <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />REVISION NOTES 12/17/2009: <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />R302.5.1 through R302.5.3. <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />R302.5.1 Opening Protection <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />the garage and residence shall be equipped with solid wood doors <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />RECESS. REFER TO MASON'S SCOPE FOR <br />R302.5.2 Duct Penetration <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />SPF #2 <br />(*) <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />nonmetallic class 0 or classl duct board, or other approved <br />40' PRODUCT LINE - MIN. 48" x 64" <br />5O' PRODUCT LINE -MIN. 48" x 76" <br />material and shall not have openings into the garage. <br />' WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />R302.5.3 Other Penetrations <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />Penetrations through the separation required in Section R302.6 <br />@ 12" O.C.' <br />shall be protected as required by section R302.11, Item 4. <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />"* WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />R302.6 Dwelling/Garage Fire Separation. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS" <br />The garage shall be separated as required by Table R302.6. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />O <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />OG <br />SEE SN SHEET �H SEE SIN SHEET <br />40 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 21X 25' <br />S.H. <br />13 <br />20X38 <br />182'X37q <br />S.H. <br />14 <br />20X50$ <br />182X50 <br />S.H. <br />15 <br />20 X 63 <br />18' X 621 <br />S.H. <br />16 <br />20X72 <br />18'X71 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />1 H3 <br />27 1/4 X 38 3 <br />26 x 37 a <br />S.H. <br />1 H4 <br />27 4 X 50 8 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 4 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 4 X 26 <br />36 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 a <br />36 1 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 $ <br />36 � X 50 <br />S.H. <br />25 <br />37 � X 63 <br />36 1 X 62 1/2 <br />S.H. <br />26 <br />37 a X 72 <br />36 z X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 25 <br />S.H. <br />33 <br />54 X 38 g <br />52 1 X 37 a <br />S.H. <br />34 <br />54 X 50 g <br />52 2'X 50 <br />S.H. <br />35 <br />54 X 63 <br />52'X X 621 <br />S.H. <br />36 <br />54 X 72 <br />521 X 71 1 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.LH. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 112" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2, <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />I. C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S. F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN - B <br />SCALE: A"=V-0" <br />O <br />clzi <br />0 N <br />N J- 4- <br />t� O O <br />-, C U <br />O W' > D_ %.- <br />_ `c ' <, C'V <br />11 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />tlf 10 <br />co <br />a O M 8 N r 3k <br />, 1.11 <br />6 LL <br />O -7 �; m o x ii <br />(0 <br />PL J Lu <br />ch "a <br />a omv x <br />U_ U- a L 5 <br />J o <br />co OIz <br />z -ate <br />13 <br />� <br />2'mN m Y O � <br />o2c, m m d <br />W co rn rn ¢ <br />a <br />Z N M Z of 0 O <br />ILW <br />Z 60 0 � 0 <br />W ❑ ❑ ❑ <br />z�� <br />z <br />O <br />Q <br />N z <br />(Du_ <br />LLD <br />I.L, Y <br />� <br />V <br />�0 S <br />N <br />c <br />(10 U <br />U <br />W <br />f- J <br />o <br />m 1 <br />4 <br />•, <br />U 8 <br />c <br />o <br />Milo` <br />¢ <br />ZZM <br />M <br />m <br />p <br />wO <br />s <br />T N <br />Q N <br />Q O V <br />. <br />w O <br />Z <br />00 <br />co <br /><o <br />U0 <br />O4 <br />Za� <br />o @ <br />Wz <br />O <br />ww <br />L <br />C <br />Q O <br />¢ <br />O� <br />m <br />a <br />�-Z <br />ZCn <br />CJ <br />J <br />m <br /><< w <br />a 3 <br />a <br />ZZ <br />° <br />a 3 <br />8 <br />-Z <br />W <br />c� 3�G <br />0 <br />�z <br />J <br />w,�Z< <br />I <br />0 <br />cCD <br />>M <br />O <br />cc <br />O <br />^� <br />W <br />�- <br />d' <br />to <br />(NJ <br />T <br />Y <br />T� <br />U) U <br />v, 0 <br />m <br />(O <br />L <br />r- <br />� <br />N <br />C) <br />0 <br />C:)0)N <br />N <br />� <br />Q N <br />r <br />ui <br />M <br />co <br />o <br />z <br />Z <br />M <br />E CV <br />rfl <br />G <br />C <br />d <br />U _J Q p <br />J <br />JOB <br />NO: 22-02370 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.2 <br />