Laserfiche WebLink
L _ t u <br />I 'L I I I I__ 1 —1 I - -- I I —1 1 <br />TYP. @ 1 <br />CORNERS D2 <br />0 <br />80 <br />O <br />F` <br />M <br />ih <br />13--0" <br />2 <br />FT3GE D2 <br />12'-0" <br />N <br />O <br />A @ 24" <br />O.C. MIN. <br />O <br />CE <br />CE <br />S6 <br />LL <br />CE <br />TYP. @ 2 STORY. <br />SEE JJ/S6 @ <br />STEMWALL <br />CE <br />FT7G <br />FT6 <br />TYP. 1 O, <br />1 <br />L1 <br />0 <br />CD <br />Ui <br />t~i <br />BRG. WALL"- <br />0 O <br />0 <br />D <br />r <br />FT8G <br />V <br />FT11 LL <br />FT13GE <br />—1 <br />BRG. WALL <br />J <br />S6 <br />TYP. @ 2 STORY. <br />SEE JJ/S6 @ <br />STEMWALL <br />35 <br />A (2) <br />22 <br />A (2) FT9 D1 <br />CJ3B <br />CJ1B <br />S7 <br />9 <br />D1 <br />7 <br />D1 <br />FG3 <br />D1 <br />m <br />� <br />A <br />TYP. <br />U.N.O. <br />0? <br />m m <br />M <br />U U <br />5'-0" <br />M <br />m <br />A <br />S3 <br />TYP. @ 1 STORY <br />(SEE AA/S3 FOR <br />STEM OPT.) <br />5'-8" <br />B4GE <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />JIND SPEED (ULTIMATE) 140.0 MPH <br />JIND SPEED (ALLOWABLE) 108.4 MPH <br />XPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SQ FEET) (-) VALUE DENOTES SUCTION a=oft [4:12]-[12:12] <br />AREA ROOF 1 2e 2n 2r 3 3e 3r, <br />HIP -35.94 49.57 -49.57 -49.57 / <br />10 <br />GABLE 38.22 38.22 -60,99 -60.99 60.99 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />I <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD I I QIr I <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD I I <br />ROOF SHEATHING: j O <br />I I <br />SHINGLE: 3/16" EXP. 1 (21/16) or t%3z' EXP. 1 (3�/16) <br />TILE: %2" EXP. 1 (33/16) I I r I <br />I I I I <br />NOTE: I I I <br />I- -I- <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %8' x 0.113") NAILS t � 13r 3r <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1V32", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2'/s" x 0.131 ") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING [4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />2 ROWS 8d @ 6" O.C. NOTE: THE SHEAR WALL FRAMING DOES NOT EXTEND <br />8d NAILS @ 6" O.C. ABOVE THE ROOF, SUB -ROOF, OR FLOOR SHEATHING <br />TO BLOCKING <br />(2) 12d NAILS TO ROOF OR FLOOR <br />BLOCKING EACH SHEATHING <br />END <br />2X4 BLOCKING AT (2) SYP#2 TOP PLATE <br />EA. ROOF PANEL <br />JOINT AT 48" O.C. <br />MAX LSTA30 EACH SIDE <br />TRUSSES @ EACH END OF <br />WALL <br />2x4 SPF STUDS <br />@ 16" O.C. WALL SEE C/S3 FOR <br />SET BACK 2" PER ADD'L INFO. <br />DETAIL C/S3 <br />SEE PLAN FOR DIM. <br />SEE FND. PLAN <br />FOR FOOTING <br />SPECS. <br />INTERIOR SHEARWALL @ TRUSSES <br />STEP-DOWN, WALL TO TRUSS <br />SCALE: 1/2 = 1 -0 <br />UPLIFT CONNECTION CROSS—REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795(2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 112" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 112" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1 1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dx1-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 1Gd x1-1/2 <br />K <br />HD36 * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005l915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />- <br />8 - 10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ (32) 16D SINKERS & <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-10d x 1 1/2" <br />SP1 <br />555 <br />535 <br />10-10d <br />SPT22 <br />735 <br />8-10d <br />SP2 <br />1010 <br />605 <br />12-10d <br />SPT24 <br />1090 <br />12-10d <br />HCP2 <br />1 590 <br />555 <br />12-10d x 1 1/2" <br />1 HHCP2 <br />1 680 <br />1 570 <br />1 (20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />'** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (6) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ('*). <br />INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 O <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) - 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />:ARRIER <br />R 2 PLY CARRIER (A) <br />xCONTLEDGER <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />FLOOR FRAMING PLAN — ELEV—B_ <br />O <br />r <br />- LL <br />C'4 <br />i <br />LL -0 <br />O O <br />U <br />L1 LU <br />cli <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />ti <br />I. o E <br />Q O (h $ N n XL <br />O N LL <br />N <br />v omNLL`L <br />0 (D 00 LL W <br />Ml tq r.- r; -+ W a <br />LL <br />M <br />Q uU_L a Lu <br />O <br />Z co zr <br />c 2 o O W <br />W (0r rn G <br />a <br />Z n z x <br />N M rn O <br />C9 U=D U) <br />OU <br />W ❑ ❑❑ <br />W <br />Z N (h <br />O � <br />z N <br />z � � <br />� <br />� <br />r <br />N <br />th <br />� I <br />� /E3 <br />� <br />V^ I1 M <br />_S? <br />W V O <br />4--J cn <br />(� w <br />Uo <br />0 w o <br />c <br />w <br />e <br />' <br />L <br />U o <br />U) <br />° <br />_0 <br />c <br />Q N <br />s <br />o0 <br />r� <br />o <br />Z <br />Cl) <br />h <br />o3 <br />� <br />J <br />LL <br />C <br />z o <br />oo <br />'aR <br />a O <br />� V <br />wz <br />z® <br />oa <br />z <br />o E <br />o ,� <br />N <br />d <br />w �o <br />o <br />z <br />-0 <br />°a <br />z <br />w z <br />L <br />¢ o <br />z <br />m 0 <br />Z <br />z <br />C,) <br />N <br />CL <br />29 <br />w9 <br />g <br />aw <br />W <br />UI <br /><0 <br />? <br />� <br />oLL <br />w� <br />=3 <br />A <br />C:) <br />co <br />V <br />0l aT° <br />a <br />3 <br />O <br />C 0 <br />2 <br />0 <br />rn <br />m <br />m <br />0 <br />L <br />� � <br />N <br />U) m <br />0 <br />r <br />NO <br />0) <br />-Q <br />N <br />Lo <br />N <br />Q T <br />r <br />ci <br />E <br />w N <br />C 6 N <br />o <br />Z <br />m <br />z <br />E N <br />a <br />E <br />U Q p <br />JOB <br />NO: 22-02370 <br />SCALE : AS NOTED <br />SHEET NO. <br />6.1 <br />