Laserfiche WebLink
—L - II <br />THIS DETAIL ONLY REFERS TO THE DIAMOND —MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />1 EMI �k� <br />1.L ..'...'....jm''... .. k .........'.. .. .:: <br />: :.k 1.,....,,,1...�,.�..... <br />16GAx1-1\2" LONG 3/4"-1" CROWN 8'. 1...::.::.:.:... ...:: <br />( ) <br />STAPLES @ 6" O.C. VERT BETWEEN MAX. I 16GAx1-1/2" LONG (3/4"-1" <br />.... ... <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES r@ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O 0 0 <br />5'-0" Q = <br />cD <br />STUB -OUT FOR 1 1 _Orr o o i 1 <br />GAS METER 0 o <br />� U <br />9 <br />N O <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) — 12" OFF —CENTER <br />• ROUGH —IN ELECTRIC TO LEFT (ALWAYS) — 12" OFF —CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'4" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist Backer Block <br />Thickness Filler Block Thickness <br />Series <br />3/4" or 718" <br />5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 wood panels 2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 wood panels 2 x — + 5/8" or 3/4" wood panel <br />902.0 2x _ lumber Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking / <br />1/8" gap --I <br />FILL CELL STD. 900 HOOK BOND BEAM <br />w <br />STD, 90° CONT. #5 <br />CONT. #5 <br />BAR --, > � HOOK �� BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />OlSolid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @INT. BRG. WALL <br />N.T.S. <br />1/8" min. 2" min. <br />2" max }Small gap , <br />• � 4 max. <br />4 <br />Clinch nails <br />when <br />possible a <br />hi <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/OSB web stiffener <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4" max. <br />required when indicated or <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />N.T.S. - Under 2nd floor column w/ loads <br />h' h th 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking / <br />1/8" gap --I <br />FILL CELL STD. 900 HOOK BOND BEAM <br />w <br />STD, 90° CONT. #5 <br />CONT. #5 <br />BAR --, > � HOOK �� BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />OlSolid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @INT. BRG. WALL <br />N.T.S. <br />1/8" min. 2" min. <br />2" max }Small gap , <br />• � 4 max. <br />4 <br />Clinch nails <br />when <br />possible a <br />hi <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/OSB web stiffener <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4" max. <br />required when indicated or <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />N.T.S. - Under 2nd floor column w/ loads <br />h' h th 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />• � 4 max. <br />4 <br />Clinch nails <br />when <br />possible a <br />hi <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/OSB web stiffener <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4" max. <br />required when indicated or <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />N.T.S. - Under 2nd floor column w/ loads <br />h' h th 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.' <br />consideration. Check <br />local building <br />11-7171 <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />er an . <br />BLOCKING PANEL, INTERIOR <br />Boise Joist Blocking Vertical load transfer =1900 plf max. along bearing wall <br />Use 3" (10d) nails at 6" o.c. Required on interior walls : - for vertical load transfer <br />Load bearing walls when load bearing -for lateral support when joists 110 <br />/ meet over wall, or wall stacks directly over wall or <br />beam below <br />Load bearing wall must stack over <br />blocking and wall or beam below.' <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />W N.T.S. <br />Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />10d nails SECTION @ INT. BRG. WALL require additional consideration. <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />Joist hanger <br />CO ❑ (O <br />6 A %" ROUND HOLE MAY 6 6 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1tz" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />Any 16" joist 12 T-i0'° ,1'-1" T' 0 T 2" .I'-3` T-9- Z-4" Z--11" 3' 7'° 4-2- 4,-9' S'-4' <br />16 T-C' 1' " T-;Z 1' 2" 1' 7" 2' 6' 3`- ' 3!-10" 4'-g' 5 7" 6-4'° T 2` <br />20 T-9' '1"" 11-21 1' 2" 91-cr 3 {7 4 �"' 14-10". 5' 11" 6'-11" 7'-11" V-11'" <br />24 T-9' 1'-1," 1, Z' 1'_3.. 2 37" 4-9t 5`-10" 7" 2- 8!-4" "'--10' ' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS, <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS, <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series De th End Intermediate <br />BCI 5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190so <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />5/8"D <br />THRU <br />BOLT <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) =11 I-111-111=1 I — <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM a " <br />SEE PLAN FOR °• a . • ; . • a <br />FOUNDATION INFO 4 ' G <br />STEM FOUNDATION <br />r—GRADE _o�,,,,� eCC Or AM <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />All. UMMOr- 4 rVU <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />��® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />d a <br />' TTilf�i • <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />i SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLU1F I <br />MBING LINE <br />d d Q <br />a d <br />Z • a. • <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />7 < C .d d <br />d <br />°' ° da G <br />1=III=I I I-11 Mi I=1 I I: <br />-T=1II_I d ° ° I=1I1=1II- <br />' <br />SEE FND. PLN. <br />SIZE & REINF. <br />p <br />a� C5 <br />eas <br />•_ <br />-p m X <br />N N t <br />t/f -l7 p <br />d <br />112-.4W <br />c <br />3 � <br />eo <br />r <br />y G� <br />_ <br />�E <br />a� <br />0 <br />INV <br />�X <br />s <br />F <br />P <br />LO <br />F E S, <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />d' E <br />0 <br />a <br />W N CO <br />W <br />0fn <br />= Lo N ,p <br />N r0 <br />tii <br />Q <br />2 : LL <br />N M S u- <br />C J <br />52 <br />J LL LL , nµ <br />In <br />Z <br />ctW <br />— : � d Y <br />@C 0 <br />W <br />7 @ N <br />ti o <br />Z <br />ILO <br />U0) m w <br />co Nz a <br />co <br />N O U U <br />W <br />oa <br />Z N cn <br />— o <br />Z N <br />z � * <br />Q <br />J <br />� N <br />V) <br />M <br />U = <br />0 <br />[� <br />a--+ <br />(13 <br />N <br />w e <br />O <br />w s <br />Ul <br />Ul <br />— <br />U � <br />W <br />—E <br />O c4 <br />o <br />2i1 <br />L <br />U u9 ID <br />Q N m <br />I= <br />o <br />CID <br />M <br />h <br />o 0z <br />N E <br />Z o <br />o� <br />o <br />� <br />Z N <br />Q� <br />Q p <br />E u <br />� <br />z® <br />H r0 <br />a= <br />Xo <br />0o <br />0 <br />— E <br />O <br />aF <br />o <br />oz <br />a z <br />N ru <br />L <br />a Zo <br />¢ <br />.92 <br />(6 <br />C <br />o <br />-, z <br />Y <br />U <br />m <br />F O <br />O <br />Z <br />_ <br />U m <br />Qz <br />W <br />d <br />o< <br />3u <br />W <br />a <br />U <br />�0 <br />�- <br />� <br />_ <br />�3 <br />_� <br />o <br />w <br />W <br />;o <br />J <br />a <br />J <br />LO <br />LO <br />rn <br />cc <br />Q <br />cc <br />0 <br />� <br />CID CV <br />co <br />_J <br />I <br />T <br />Y <br />T <br />- <br />m <br />m <br />LO <br />¢� <br />O <br />N <br />o <br />M <br />LO <br />r- <br />to <br />r— <br />hi <br />E <br />_ 'A` <br />o <br />z <br />z <br />� . <br />E <br />N <br />T <br />c <br />c <br />U <br />d <br />J <br />Q 0 <br />JOB <br />NO: <br />22-06475 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />a� <br />a <br />