Laserfiche WebLink
1_ ___ __u'1, <br />60 <br />llr <br />8. <br />FLAT CLG. <br />= CARPET <br />Y <br />oCl) <br />N _ W <br />A <br />S3 <br />TYP @ 1 <br />STORY <br />0 N <br />0 <br />c� <br />0o (D fn <br />in <br />co <br />PATIO <br />4'-0" <br />124 <br />1 <br />IIIIICIIIIIIIIIIIIIIIIICIIIIIIIIIIIIIIIIIICIIIIIIIIC)I <br />aBEDROOM <br />1. <br />1 <br />CARPET <br />i <br />I <br />co <br />2668 <br />. <br />JILE <br />I.. <br />- <br />2668 <br />! <br />11' 4„ <br />I I <br />, � <br />r� <br />_T� <br />N <br />4068 B.F. <br />FIBERGLASS, <br />8'-34" <br />3' <br />SURROOUND <br />rN <br />60" X 36" <br />------- <br />_ _ _ ----- <br />i> <br />SHOWER <br />R&S <br />16" DEEP <br />O O <br />PANTRY <br />-- - <br />----^ <br />OVERIFY <br />A <br />25-SH <br />METER <br />LOCATION WITH <br />BUILDER <br />11111111111110 71 <br />I <br />EGRESS <br />i <br />I <br />BEDROOM <br />1 <br />8'-0" FLAT CLG. <br />051 <br />00 <br />I <br />CARPET <br />�1 <br />00 <br />I <br />I <br />I <br />I <br />0 <br />0 <br />I <br />I <br />11'-10" <br />24 <br />(0 <br />1 <br />0'-4" <br />HALL <br />9'-4" FLAT CLG. 2668 <br />CARPET <br />BEDROOM 4 <br />8'-0" FLAT CLG. <br />CARPET <br />T-0" 9'-82' <br />I <br />4068 B.F. <br />`14 R&S <br />3'-0" <br />H.B. <br />w 8'-0i 9`1 9 : <br />w K --- <br />_o RA E o I S3 i ------ -- <br />OWNER'S �= TILE <br />I `-° i T I I I <br />SUITE I <br />I <br />� TILE � I i � 8 0 LA CLG.I <br />8'-0" FLAT CLG. it <br />CARPET I 2'16" '-2" -- I 928 I _58, 4, 5134" T <br />I SINK DIS <br />STUDS W/ USP 2x4 #2 SYP K 2-CAR GARAGE I <br />Sr � i S3 I C'3 <br />HTT4@ BASE S3 I� D.W. O O 8'-0" FLAT CLG. <br />00 lI L_�I � ' FIBERGLASS <br />I _o Fr SURROUND I <br />EDGE OF SLAB 2" <br />BEYOND WALL 3� <br />5'-0" 1'-78 G HA NSC lN BOX @ <br />S3 DRYER VENT <br />36 A.F.F. THRU ROOF <br />PT. W OPT. <br />D 20'-9" i <br />3'-8' 2'-8" 4'-3" 6'=10" 3'-7" o I <br />"AT4 11 i <br />2:12I z C <br />! <br />FL <br />CEILING I ry TILE 6'-74" <br />N I <br />I I II I I I <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />b W.H. L--J I <br />ML--------- -- <br />�'� r FAMILY ROOM I I <br />i� VAULT. CLG. CAFE <br />CARPET <br />VAULT. CLG. <br />i CARPET s <br />I 30'-0" 41-13" '-3" 068 1 <br />i' w bN w B04 <br />z z 6cNLU <br />I <br />!�1 - i - - - - -- 1 <br />N <br />H.B. <br />T-0" <br />21'-5" <br />A <br />S3 <br />37-8" <br />35-SH <br />0 <br />16-3" <br />59'-4" <br />0 <br />�O <br />C� <br />ENTRY Lo <br />- <br />8'-0" FLAT CLG. <br />1 <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 112" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 112" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />187'X2571 <br />S.H. <br />13 <br />20X38J <br />18#X37J <br />S.H. <br />14 <br />20 X 50 J <br />18 J X 50 <br />S.H. <br />15 <br />20X63 <br />18JX62J <br />S.H. <br />16 <br />20X72 <br />184X714 <br />S.H. <br />11-12 <br />271/4X26 <br />26X254 <br />S.H. <br />11-113 <br />271/4X38i <br />26x37i <br />S.H. <br />1 H4 <br />27 J X 50 i <br />26 x 50 <br />S.H. <br />11-15 <br />27-1X63 <br />26X621/2 <br />S.H. <br />11-16 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 � X 72 <br />3617 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52,'X 25 <br />S.H. <br />33 <br />54 X 38 J <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 2 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />0 <br />0 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302,5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE"C" <br />® <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />O <br />SEE SN SHEET SEE SN SHEET <br />140 MPH <br />NOTE; WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />INTERIOR BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION - B1 <br />1ST FLOOR LIVING AREA 1817 <br />LIVING TOTAL 1817 <br />GARAGE 427 <br />FRONT ENTRY 32 <br />TOTAL AREA 2276 <br />PATIO 23 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />FLOOR PLAN ELEV B 1 EXT FRAME 2 x 6 R-13 KRAFT FACED <br />CONDITIONED CEILING R-0 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />SCALE: %4"=1'-0" GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />iV <br />117'4 <br />0 <br />on = <br />ar =a <br />C2 <br />E�o <br />o-r o <br />� c-2 <br />c I a <br />(a v L <br />'0-�_ <br />cc <br />_: d . <br />E c <br />o_ <br />c E <br />m o <br />O- U <br />Ra�`e��`��E$$Y$f4/$•d� <br />, � <br />OW <br />;r• O <br />4 <br />�-• r . <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />W <br />ar3o8 <br />N p <br />N cor-N N rm <br />N on-o # <br />Q -MvC U- u. <br />LL <br />J W <br />LL LL D <br />J uJ <br />Z -�� <br />t 10O <br />L � cc <br />W05 cp ' m Lu <br />Co 0 <br />Q J <br />Z LO Cl) <br />ZN O U 0 U <br />w ❑O <br />M C, <br />z N o <br />z N <br />� <br />cZ v <br />13 <br />z <br />� � o <br />�N lL <br />Cn <br />L.IJ <br />ig <br />U <br />O g <br />vi c <br />U <br />H J E <br />- <br />r <br />z1 <br />8 <br />QN0 <br />s <br />O <br />co <br />w <br />MZ <br />o <br />Z <br />< <br />Q E <br />E <br />wo <br />oo <br />,q <br />QR <br />0� <br />u <br />r <br /><'z <br />0 <br />,0 <br />o <br />Q <br />E <br />O <br />.0°a <br />az <br />az <br />iZ <br />CO c <br />oY <br />�m <br />m0 <br />Oz <br />Z <br />< 6 <br />aw <br />g z <br />cn <br />o¢ <br />ao <br />� 3 <br />�w <br />W <br />U3 <br />wLL <br />0 <br />�LL <br />= H <br />�3 <br />o <br />CD <br />wz <br />�O <br />a <br />v <br />a <br />°� <br />I <br />J <br />Lid <br />LO <br />co <br />r <br />cle) <br />Cr <br />_N <br />T <br />U <br />U) o <br />N <br />m <br />m <br />LO <br />T <br />¢1 <br />,} j <br />N <br />0 o <br />CD <br />r <br />N <br />T <br />LO <br />�--� <br />CO <br />T <br />E <br />c <br />O <br />z <br />E co onz <br />CD <br />m` <br />c <br />a <br />U Q p <br />c <br />JOB <br />NO: 22-06475 <br />SCALE : AS NOTED <br />SHEET NO. <br />1 <br />