Laserfiche WebLink
WINDOW ELEVATIONS <br />1/2" = 1'-0" <br />Window Schedule <br />W1 <br />LOBBY WINDOW <br />2' - 0" <br />7' - 0" <br />W2 <br />GROOMING WINDOW <br />2' - 0" <br />5' - 0" <br />TWO T-0" DOORS <br />,i <br />ENTRY DOOR <br />FENCE SCHEDULE <br />F1 <br />VESTIBULE FENCING <br />F2 <br />5' FENCE PANEL <br />F3 <br />6' FENCE PANEL <br />F4 <br />8' FENCE PANEL <br />WALL AND PARTITION SCHEDULE <br />WALL <br />TYPE <br />WALL STRUCTURE; SEE DETAILS ON A120 <br />Al <br />20 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF MOISTURE RESISTANT GWB EACH SIDE <br />A2 <br />20 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 1/2" MOISTURE RESISTANT GWB EACH SIDE <br />A3 <br />20 GA 2 1/2" MTL STUD 16" OC W/ 1 LAYER OF MOISTURE RESISTANT GWB ON INTERIOR SIDE. WALL ONLY EXTENDS 5' AFF. RETURNED WITH GYP BOARD BACK TO EXISTING WALL AT TOP. <br />A4 <br />18 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 5/8" MOISTURE RESISTANT GWB EACH SIDE. WALLS ONLY EXTEND TO MEZZANINE HEIGHT. <br />A4.1 <br />18 GA 3 5/8" MTL STUD 16" OC W/ 1 LAYER OF 5/8" MOISTURE RESISTANT GWB ON INTERIOR SIDE. WALLS ONLY EXTEND TO MEZZANINE HEIGHT. <br />A5 <br />TWO CHANNELS OF 20 GA 2 1/2" MTL STUD 16" OC W/ GWB ON INTERIOR FACING SIDES <br />A6 <br />TWO CHANNELS OF 20 GA 2 1/2" MTL STUD 16" OC W/ GWB ON INTERIOR FACING SIDE AND EIFS FINISHED TO MATCH EXISTING FINISH ON EXTERIOR <br />A7 <br />FEATURE WALL; FINISH TO BE SELECTED BY OWNER. <br />F3 <br />6' VINYL FENCE PANEL <br />SF1 <br />NEW STOREFRONT; SEE Al02 <br />,, <br />, <br />, <br />, <br />, <br />SUITE DOOR <br />Suite Schedule <br />Name <br />Area <br />Count <br />STD <br />368 SF <br />23 <br />LUX <br />139 SF <br />7 <br />DBL <br />61 SF <br />2 <br />TYPE <br />ENTRY DOOR <br />SUITE DOOR <br />PASSAGE DOOR <br />RESTROOM DOOR <br />SALVAGED EXTERIOR DOOR <br />568 SF 32 <br />�s <br />0 <br />� <br />0 <br />�Ec3Qi�i <br />a <br />zC <br />T-0" <br />PASSAGE DOOR <br />T-0" <br />RESTROOM DOOR <br />, <br />, <br />, <br />, <br />, <br />T-0" <br />SALVAGED EXTERIOR DOOR <br />DOOR AND FRAME ELEVATIONS <br />1 /2" = 1'-0" <br />DOOR HARDWARE SCHEDULE <br />HW SET <br />HANDLE <br />CLOSER <br />DEADBOLT <br />KICKPLATE <br />PANIC <br />ENTRY/EXIT <br />YES <br />PASSAGE <br />LEVER <br />NO <br />NO <br />NO <br />NO <br />SUITE <br />PUSH/PULL PLATE <br />NO <br />YES <br />NO <br />NO <br />Door Schedule <br />Height <br />MAT <br />Finish <br />MAT <br />FINISH <br />HEAD <br />JAMB <br />SILL <br />HW SET <br />Count <br />T - 0" <br />STOREFRONT <br />ENTRY/EXIT <br />1 <br />6'- 8" <br />FIBERGLASS <br />VINYL <br />PT-3 <br />H1 <br />J1 <br />S1 <br />SUITE <br />32 <br />6'- 8" <br />FIBERGLASS <br />VINYL <br />PT-3 <br />H1 <br />J1 <br />S1 OR S2 <br />PASSAGE <br />7 <br />6'- 8" <br />FIBERGLASS <br />VINYL <br />PT-3 <br />H1 <br />J1 <br />S1 <br />PASSAGE <br />1 <br />7' - 0" <br />EXISTING <br />EXISTING <br />ENTRY/EXIT <br />1 <br />VERIFY ALL DIMENSIONS, SQFT, AND COUNTS IN FIELD OR BEFORE INSTALL. <br />1. <br />THE EXISTING DEMISING <br />1. <br />GC IS TO PROTECT ALL <br />WALL(S) MAY BE RATED <br />EXISTING ITEMS TO REMAIN <br />ASSEMBLY - U.L. THIS <br />(SUCH AS MILLWORK, <br />PARTITION IS REQUIREDTO <br />FLOORING, TRIM, ETC) <br />PROVIDE A CONTINUOUS <br />THROUGHOUT THE COURSE <br />MIN SEPARATION FROM <br />OF THE JOB. ALL SURFACES <br />TENANT SPACE TO ALL <br />AND FINISHES TO REMAIN <br />ADJACENT SPACES. GC TO <br />UNLESS NOTED. IF <br />VERIFY RATING OF <br />DAMAGED DURING <br />PARTITION ABOVE <br />DEMOLITION OR ANY STAGE <br />CORRIDOR CEILING AND <br />OF WORK, SHALL BE <br />MAINTAIN RATING AS <br />REPAIRED BY THE GC AT <br />NECESSARY. <br />HIS EXPENSE TO "LIKE <br />2. <br />PARTITION SUPPORT <br />NEW" CONDITION. <br />KICKERS ARE NOT TO BE <br />2. <br />REMOVAL OF WALLS TO <br />VISIBLE FROM HALLWAYS <br />INCLUDE PATCHING AND <br />AND OTHER PUBLIC <br />PREPING FOR NEW <br />SPACES. <br />FINISHES AT ADJACENT <br />3. <br />ALL WALLS SHALL EXTEND <br />WALLS WHERE IMPACTED <br />6" ABOVE DESIGNATED <br />BY DEMOLITION. <br />CEILING HEIGHT UNLESS <br />3. <br />GYPSUM BOARD WALLS TO <br />NOTED OTHERWISE. <br />BE TAPED, SANDED, AND <br />4. <br />SUPPORT KICKERS TO <br />FINISHED TO MATCH <br />STRUCTURE OR TO <br />EXISTING UNLESS <br />PERPENDICULAR <br />OTHERWISE NOTED. <br />PARTITION WALL. <br />4. <br />GC IS RESPONSIBLE FOR <br />5. <br />NO EXPOSED DRYWALL UP <br />THE REMOVAL OF EXISTING <br />TO 5' IN ANY PLAYROOM <br />FINISH FLOORING DOWN TO <br />INTERIORS. SEE DETAIL <br />THE SLAB, SUBFLOOR, OR <br />FOR FINISHING SPEC. <br />WOOD FLOOR JOISTS IN <br />6. <br />ALL CINDERBLOCK WALLS <br />ALL AREAS WHERE NEW <br />NEW OR EXISTING MUST BE <br />FLOORING IS SPECIFIED. <br />SEALED AND FINISHED. <br />5. <br />GC IS TO REMOVE ALL <br />7. <br />ALL INT SUITE PARTITIONS <br />INACTIVE PIPES, DUCTS, <br />TO BE 6' IN HEIGHT. <br />AND ANCHORS WHICH ARE <br />8. <br />EXT SUITE GYP WALLS NOT <br />NOT TO BE USED AND <br />TO REACH CEILING TO <br />PATCH SURFACES TO FLAT <br />ALLOW AIRFLOW. SEE <br />CONDITION. <br />DETAIL FOR WALL HEIGHTS. <br />6. <br />DO NOT REMOVE ANY <br />9. <br />ALL INTERIOR WALLS TO BE <br />EMERGENCY OR FIRE <br />WALL TYPE Al UNLESS <br />PROTECTION SIGNALS AND <br />OTHERWISE NOTED. <br />EQUPMENT U.O.N. PROTECT <br />10. <br />ALL WALLS WITH SUITE <br />AS REQUIRED FOR <br />DOORS INSTALLED SHALL <br />DURATION OF THE JOB. NO <br />BE WALL TYPE A2. <br />ACTIVE SMOKE DETECTORS <br />SHALL BE COVERED OR <br />OTHERWISE RENDERED <br />FLOORING • <br />INEFFECTIVE. <br />7. <br />RELOCATE EXISTINGACTIVE <br />1. <br />BANYAN CS FLOORING <br />OUTLET BOXES, <br />SCOPE NEEDS TO BE <br />JUNCTION BOXES, ETC., <br />SIGNED BEFORE ANWORK <br />Y <br />WHICH ARE RENDERED <br />BEGINS. <br />INACCESSIBLE BY NEWCONSTRUCTION. <br />2. <br />REFER TO BUDGET. IF YOU <br />HAVE EXCESSIVE FLOOR, <br />SEND UP RED FLAG. <br />3. <br />FLOOR PREP AND GENERAL <br />DOOR NOTES <br />SWEEP TO BE COMPLETED <br />BEFORE INSTALL. <br />1. <br />ALL NEW INTERIOR DOORS <br />4. <br />NO SWEEPING DURING <br />TO BE LEVER TYPE DOOR <br />INSTALL - VACUUM ONLY. <br />HANDLE WITH EXCEPTION <br />5. <br />FLOORING MUST RUN <br />OF THE 'SUITES'. THESE <br />UNDER ALL CABINETS. <br />ARE PUSH/PULL. <br />6. <br />GROUT MUST BE WIPED <br />2. <br />ALL DOORS PROVIDE 32" <br />OFF IMMEDIATELY AFTER <br />CLEAR WIDTH IN THE FULLY <br />APPLYING. <br />OPENED POSITION AND ARE <br />7. <br />FLOOR CLEANOUTS & <br />READILY OPENABLE FROM <br />FLOOR DRAINS MUST BE <br />EGRESS SIDE WITHOUT <br />LEVEL. DO NOT GROUT <br />KEY, SPECIAL KNOWLEDGE <br />UNTIL LEVEL. <br />OR EFFORT. <br />8. <br />ALL CERAMIC TILE MUST BE <br />3. <br />ALL HARDWARE FINISHES <br />SEALED PRESSED TILE IN A <br />TO BE BRUSHED SATIN <br />NEUTRAL, LIGHT COLOR <br />NICKEL FINISH UNLESS <br />AND WITH LIGHT COLORED <br />OTHERWISE NOTED. <br />GROUT. <br />4. <br />ALL EGRESS DOORS (NEW <br />9. <br />LVP NOT TO BE USED IN <br />OR EXISTING) LEADING TO <br />ANY AREA DESIGNATED <br />THE EXTERIOR OF THE <br />FOR ANIMALS (IE <br />BUILDING ARE TO HAVE <br />PLAYROOMS, SUITES, <br />SIGNS ON THEM STATING <br />GROOMING, LEASH). <br />THIS DOOR TO REMAIN <br />'UNLOCKED <br />DURING <br />NOTESINSTALL <br />BUSINESS HOURS". <br />5. <br />VERIFY THAT ALL LOCK <br />1. <br />PORCH LIGHTS ON SUITES <br />KEYED CYLINDER(S) SHALL <br />TO BE INSTALLED ON <br />BE OF THE TYPE THAT <br />CENTER BETWEEN DOOR <br />ACCEPTS INDUSTRY <br />FRAMES. <br />STANDARD "SMALL FORMAT <br />2. <br />ALL PLAYROOM FENCING <br />INTERCHANGEABLE CORES" <br />TO BE 5' HIGH UNLESS <br />(E.G. FALCON, ARROW, <br />NOTED OTHERWISE. <br />BEST, ETC). CONTRACTOR <br />3. <br />ALL PLAYROOM FENCE <br />SHALL INSTALL SAID LOCKS <br />GATES TO BE T MIN WIDTH <br />WITH CONTRACTOR'S OWN <br />AND MATCH ADJACENT <br />CORES AND QUANTITY OF <br />FENCE HEIGHT. <br />KEYS REQUIRED FOR <br />4. <br />ALL PLAYROOM GATES TO <br />CONTRACTOR PURPOSES <br />HAVE SELF -CLOSING <br />DURING CONSTRUCTION. <br />HINGES. <br />6. <br />ALL INTERIOR DOORS TO <br />5. <br />BASE OF PLAYROOM FENCE <br />HAVE THRESHOLDS <br />RAIL TO BE MAX 1" AFF. <br />REMOVED BEFORE INSTALL. <br />7. <br />ALL STANDARD SUITE <br />PLAN NOTES <br />DOORS TO BE CENTERED <br />ON SUITE SPACE. <br />1 <br />BLACK OUT BOTTOM OF <br />8. <br />PASSAGE DOORS TO USE <br />WINDOW UP TO 5`. BAR <br />S1 WHERE TILE FLOOR IS <br />ACROSS ON INTERIOR. SEE <br />UNINTERRUPTED BETWEEN <br />DETAIL. <br />SPACES. S2 TO BE USED <br />2 <br />SEAL DOORS SHUT AND <br />WHERE LVP TRANSITIONS <br />BLACK OUT DOOR GLASS UP <br />TO TILE FLOORING. <br />TO 5'. SEE DETAIL <br />3 <br />REUSE SALVAGED DOOR. <br />SUITE NOTES <br />SEE DEMO NOTE 4 ON AD101. <br />4 <br />18" VIEWING PLATFORM. SEE <br />1. <br />ALL STD (STANDARD) <br />DETAIL ON A121. <br />SUITES ARE 4'-0" x 4'-0" UNO. <br />2. <br />ALL LUX (LUXURY) SUITES <br />5 <br />4" x 4" x 10' STEEL POST <br />ARE 4'-0" x 5'-0" UNO. <br />CORE DRILLED 2'. FINISH <br />3. <br />SEE FINISH SCHEDULE AND <br />HEIGHT 8' AFF TO ANCHOR <br />FINISH PLAN FOR DETAILS. <br />A2 WALL <br />6 <br />ADA RAMP. SLOPE TO MEET <br />ADA REQUIREMENTS. VERIFY <br />HEIGHT DIFFERENCE IN <br />FIELD AND PROVIDE 12" OF <br />RAMP FOR EVERY 1" OF <br />RISE. <br />FLOOR <br />NEW DOOR AND FRAME <br />TO BE INSTALLED <br />EXST DOOR AND FRAME <br />PORCH LIGHT <br />VL- <br />C 0 R I L A N 0 <br />M 0 R G A IN <br />ARC H I H C <br />711 N. FIELDER RD. <br />ARLINGTON, TX76012 <br />PH: (817) 635.5696 <br />FAX: (817) 635.5699 <br />CERTIFIED BY: <br />,LAND Mph, , <br />o y, <br />'U <br />All-OO15586 <br />sTFh'ED ARG <br />CORTLAND MORGAN <br />FLORIDA REG. AR - 0015586 <br />D RAW N BY: <br />STAFF <br />90% <br />1 f TtvtTOWN <br />6440 FORT KING <br />ZEPHYRHILLS, FL <br />33542 <br />DARREN & LUANN <br />Owner <br />Mimi vi M IL <br />CONSTRUCTION <br />JANSEN GEHRING <br />317.747.055-5 <br />ZEPHYR HILLS <br />FLOOR PLAN & <br />SCHEDULES <br />FLOOR PLAN <br />1 /4" = 1'-0" <br />3/17/2022 4:14:04 PM <br />