My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6469 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6469 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 6:18:27 PM
Creation date
2/18/2025 3:28:21 PM
Metadata
Fields
Template:
Building Plans
Street #
6469
Location
Bar S Bar Trl
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER 1x4 <br />ri/2" DRYWALL <br />DOOR JAMB (REFERr2X <br />1/2" DRYWALL <br />TO PRODUCT <br />P T <br />TO PRODUCT <br />__j_ _ <br />TO PRODUCT <br />APPROVAL FOR CON <br />APPROVAL FOR CONN. <br />1x4 P.T. <br />APPROVAL FOR CONN. <br />1x4 <br />1 X 4 <br />FURRING <br />3-1/4" LONG X 3/16"0FURRING <br />3/16" 0 X 3" LONG <br />TAPCONS <br />FURRING <br />(2) ROWS 3/16" x 3-1/2TAPCON. <br />INTO <br />STAGGERED @ 16" <br />TAPCON @ 16" O.C. &BLOCK@ <br />SPACING „ <br />1 <br />DETAIL <br />1x8 <br />O.C. 2-ROWS INTO <br />P.T. <br />FROM EACH END w/ M. <br />2" EDGE DIST. ATTACH <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1 /211 <br />DETAIL <br />1x8 w/ (2) ROWS 8d NALS <br />" <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C. <br />3/16" x 3 -1/2" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />1x4 <br />1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/MIN <br />TO PRODUCT <br />TO PRODUCT <br />2" EDGE DIST. <br />APPROVAL FOR CONN. <br />2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. <br />(2) ROWS 3/16" x 3-1/2" <br />x 3-1/2" TAPCON @ 16" <br />O.C. & 4" FROM EACH <br />1x4 <br />TAPCON @ 16" O.C. & <br />END w/MIN. 2" EDGE DIST. <br />FURRIN( <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" <br />2x8 <br />')., n=Ail <br />11A11 MCTA11 <br />STAGGERED @ 12" O.C. <br />1-1/d" I)GT,&II <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS <br />SCALE: N.T.S. <br />1/4" MAX <br />I� SOLID BLKG. AT TOP BTWN. <br />N ARCH BLKG. & BUCK <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 114" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45A DIAGONAL (4)10d NAILS INTO <br />BRACE(S) 7/16" OSB 2 x 8 BRACE/ BLKG. <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHO\\,-2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU —� <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />2 x 8 BUCK - CONNECT TO BLOCK <br />2'-0" <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. - <br />/4„ MAX EMBEDMENT INTO ) <br />2'-0" <br />BLOCK HEADER <br />SOLID BLKG. AT TOP BTWN. ARCH <br />1 X 4 FURRING <br />BLKG. & BUCK <br />8d NAILS @ 8" O.C. AT BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />PROVIDE 2 x 8 DIAG. BRACE B <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />LEAVE A CUT OUT IN O.S.B. ON TI <br />2 x 8 VERT. BRACE(S) <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />INSTALL WDW, SCREW <br />THRU OSB INTO 2 x 8 <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />ARCH DETAIL K <br />B-B <br />SCALE: N.T.S. SS <br />�- SECTION <br />A -A <br />8" <br />1/4" x 31/4" TAPCONS <br />—LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />�2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />EQUAL <br />;13�P1[1��J <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />PROPER INSTALLATION MAX. 8" <br />FILL SOLID <br />BOTH CELLS <br />#5 REB, <br />(TYP,) <br />STD. 90' <br />HOOK (1 <br />JL <br />71� <br />JE/// <br />±5A <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />3APACITY = 805 # FOR 1 STRAP <br />=1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"xl 1/2" SDS <br />SCREWS & (5) 1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7)1/4"x2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4W' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE ALL <br />(5)12d NAILS SIMPSON <br />2X6 TO 2X4 H2.5A w/ (10) <br />8d NAILS <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL <br />PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) <br />EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />SEALANT <br />* PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE W/ <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br /><: <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />a, `.. 6" MIN. LAP <br />G) SET SUCCEEDING COURSE OF BLOCKS, SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE NOTE: <br />REMAIN FREE OF MORTAR. <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BYE <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. 00, <br />4'-0" MAX"r/// <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH --/ <br />IF TRUSSES USED) W/ (2) #6 X 4%' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4' X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = V-0" SS <br />#5 CONT. TOP & MID <br />11 <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />WITH MIN. 3 COVER 61-011 <br />11 It <br />GRADE n p An <br />`h z . <br />e. <br />(2) #5 REBAR. (1-STORY) <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />Of <br />100 A. <br />SECTION AT DEEP MONO FOUNDATION <br />REV. 07.28.21 <br />SCALE: 3/4" =1'-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE INSTALLTION <br />DO NOT DO THIS <br />2N BOT. PLATE W/ (2)10d @ 6" O.C.. <br />` #5 REBAR (TYP,) <br />3/4" PLYWOOD DECKING GLUED _ <br />ATTACHED WALL SHEATHING TO <br />BOTTOM PLATE W/ 8d 4" <br />kR ` ' <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />O.C., 2 ROWS STAGGEREDD <br />O <br />O. <br />41 <br />`STD. 90° HOOK (TYP.) <br />`4%h, <br />2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />YP.) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />— <br />1:711 1 1 rl/ <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />' +2» NOTC @ FIRST COURSE <br />` <br />SIMPSON HGAMIOKTA @ 12" O.C. <br />w/ (4)1/41 1/2" SDS SCREWS <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />THE <br />:S ` <br />L/� <br />L <br />FILLED CELL INSTALLATION H <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />2x SUB FASCIA <br />ALUM DRIP EDGE <br />BRG WALL TYPE ALUM FASCIA <br />PER PLAN I I 1-3/4" TRIM PAINTED <br />F CHANNEL, SS NAIL w/ 5/16" HEAD <br />FASTENED PER DIA. @ 24 O.C. <br />NOTE 2 BELOW CONT VENTED OR SOLID SOFFIT <br />CONT 2x4 NAILED TO 2x BLOCKING NAILED TO TOP <br />BLOCKING w/ 2-12d NAILS (*`) CHORD EVERY OTHER TRUSS <br />w/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />j ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 16544 R5 FL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />- CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />- WOOD w/ (3) 16 GA. 3/4"x1/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />- SUB FASCIA w/ 16 GA. 3/4"x1/4" CROWN STAPLE @ EACH GROOVE <br />ESF01 STRUCTURAL SOFFITSCALE: 3/4 = 1 O ( ) FOR ALUMINUM SOFFITS WITH SPANS <br />REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />?k TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />O�F/�j/q * DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />+ + �FNGry (2)10d NAILS @ 8" O.C. <br />+ + TO TRUSS TOP CHORD <br />+ + PLYWOOD SHEATHING <br />BLOCKING AS <br />'RUSS + REQUIRED TO <br />+ SUPPORT SOFFIT <br />2X4 SYP . . <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL <br />SCHED. <br />ENTER SO IT <br />PRECAST LINTEL <br />I , IjJ1L�' SEE ELEVATION ' <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = V-0" SS <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON SET <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: 311f - I -u <br />CFI= CWPPT n) AMr) <br />z <br />O <br />U_ <br />O <br />w <br />a <br />U <br />Cn <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />FOR OVERHANGS BETWEEN OVER 1 112" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />OVERHAN <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />1'-0" 5-0" <br />NISH <br />• ', a ►;. ' : #5 BAR <br />p : .• CENTERED W/ g <br />..' +�► IN TOP 4 <br />• •' a KNOCKOUT / ZN <br />' CHAIR BLOCK <br />MONO FOOTING - ' <br />SIZE AND REINF. PER PLAN e. <br />AND SECTION DETAILS <br />CLEAN FILL <br />DIRT Z <br />e. <br />' STANDARD 9 <br />i 90' HOOK tv <br />#5 BAR IN <br />FILLED CELL �— <br />�s— <br />STEMWALL FOOTING SIZE AND <br />REINF. PERLAN AND STEMWALL <br />MONO TO STEMWALL FOOTING SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC' <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY 12") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />I EXISTING FOOTING <br />RETROFIT FILLED CELL DETAIL <br />(2) #5x6' IN CONC. <br />FILLED CELL <br />4" SAW CUT <br />A SECTION <br />1 SCALE: N.T.S. <br />SCALE: N.T.S. <br />d <br />N <br />cV <br />N = <br />dW <br />91 no <br />E! <br />_= o <br />c.i c.amM <br />Ct <br />•y � N r <br />N 4 <br />Q .d..Y <br />a. <br />¢' <br />� c <br />� eta <br />,° <br />CL) o <br />a A <br />N <br />o <br />d J <br />..1,I, <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Billion. Engineer's signature and seat is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seat. <br />p <br />N <br />V C., <br />N O <br />di aj <br />LL <br />_j <br />LL LL DW_ <br />I^ �C u. <br />zgrn ° <br />IL 04 N Z Q <br />N OU 00 <br />Z <br />W ❑ ❑ <br />CD V <br />0 <br />� <br />Z N <br />z C <br />z F <br />CD <br />v) U o <br />Cn <br /><U <br />�O L <br />w <br />Ul) <br />c <br />' W <br />= a <br />U <br />c <br />Q Y <br />N � <br />w <br />z <br />ch <br />4 <br />� <br />E <br />oo <br />aR <br />Q <br />E <br />E <br /><0 <br />w0 <br />Z <br />of <br />$� <br />a <br />m= <br />00 <br />- C <br />g� <br /><U o Z <br />W <br />�W <br />NJ <br />T O <br />> CO <br />cr_ <br />Lf0 <br />L10 <br />rn <br />` <br />'^ <br />Fes- <br />i.. <br />j C) <br />CM <br />O <br />Y <br />m <br />m <br />LLO <br />r <br />»I»�+ N <br />Qi <br />�� <br />� N <br />N <br />O <br />00 <br />LO <br />CM <br />QLO <br />r <br />E <br />t\ <br />o <br />z <br />z <br />E r �; <br />a <br />U Q p <br />JOB <br />NO: 22-06470 <br />SCALE : AS NOTED <br />SHEET NO. <br />SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.