My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6469 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6469 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 6:18:27 PM
Creation date
2/18/2025 3:28:21 PM
Metadata
Fields
Template:
Building Plans
Street #
6469
Location
Bar S Bar Trl
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />'' MASONRY <br />WINDOW BUCK- <br />2 ) SEALANT JOINT <br />5) SEALANT FROM <br />5) <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME Tf <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTI( <br />1. Cut, fold up & temporarily secure <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3, Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING-, <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WEATHER <br />JE BARRIER & <br />tARILY SECURE <br />WOOD FRAME CONSTR, <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI; <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />8 2 <br />1- SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL <br />SELF -ADHERED FLASHING <br />NAILING FLANGE 1 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />8 (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />MIA EXTERIOR DOOR WITH DECK <br />Sri <br />I Ili DOUBLE <br />j JOIST <br />I <br />j -SINGLE I, I,I'li WOOD BEAM <br />JOIST <br />BELOW <br />SELF -ADHERED - SELF -ADHERED <br />FLASHING FLASHING Q <br />SCS 06 02 WINDOW FIN INTERFACE WITH SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER DECK JOIST <br />SELF -ADHERED FLASHING 2xFRAMEWALL <br />PRODUCTS DETAILS TILE FINISH - <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked asoRstructions <br />in each detail that corresponds to the <br />numbered items in the list below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />1/2" DUROCK- <br />l'-4" PER PLAN <br />1'-0" PER PLAN <br />NO E a <br />Ufa C <br />-• �_ �M M <br />rill �_ <br />M <br />SHOWER SEAT <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />/- DOOR ROUGH OPENING <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />- 3/4"-1" BEAD OF CONSTR. (0.6 cm: 30.5 Cm) include flashing as described in Section R703.4. <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />NAIL BRAND OR EQUAL WEATHER EXTERIOR water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />PROOF CAULKING CEMT. FIN. <br />SELF -ADHERED FLASHING BUILDING PAPER of draining to the exterior water that penetrates the exterior cladding. <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />SUBFLOOR other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />FLASHING REQUIREMENTS <br />i' <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />RIM JOIST <br />j <br />7 <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />1 <br />�1 <br />u <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />2 <br />Q <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />JI M-- <br />SELF -ADHERED FLASHING <br />EMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER 1 <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />FLANGED WINDOW (SEE <br />(SEE DETAILP01) <br />membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED <br />prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF -ADHERED FLASHING, <br />-o (BEFORE FOLDING, SCORE <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />EXTEND AMINIMUM 6" <br />POSE RE <br />ADHESIVELEASE PAPER OWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />VERTICALLY FROM <br />BOTTOM OF <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD <br />shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />AAMA 712. Flashing door be installed in more of the <br />2 <br />shall comply with at exterior window and openings shall accordance with one or <br />following: <br />5 <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />1 <br />6 <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />2 <br />7 <br />subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides: <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />1--SIL <br />SELF -ADHERED FLASHING ' <br />A <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />INSIDE CORNER <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />- <br />Ground,- <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4. 4. Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1 <br />6.6.At wall and roof intersections. <br />w t R c c B rl <br />7.7.At built-in autters. <br />:LF-ADHERED FLASHING <br />ETCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />i <br />Q <br />Lu <br />W <br />lii II <br />- <br />14 <br />14 <br />g g _. _.-_. II <br />a o. -tv <br />Cr LU PLASTER STOP <br />_ co <br />rn CONTINUOUS BACKER <br />U ROD & SEALANT <br />= cr <br />N Cr <br />AV <br />Lu <br />�° A <br />U) <br />e <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />a er es <br />ls an ar er <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) -' o--- - <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - <br />BOND BREAK WEATHER RESISTANT BARRIER- - - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY -- - ---- <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />}. STRIP OF SAF <br />- - DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />--SF LATH <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact, Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact, Specs, <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or situ. <br />caulk for all <br />II I <br />Note: <br />The building paper and metal lath must be <br />Cement <br />installed over the top of the weep screed. <br />- - <br />ER STOP A <br />NUOUS BACKER ROD <br />LANT <br />Plaster <br />over block <br />1 st floor <br />NTITIOUS FINISH <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />rN <br />tV <br />6/ <br />• <br />La 1 <br />CA <br />> <br />o <br />W <br />Li <br />C 10 <br />0 <br />N <br />Q <br />� <br />CC <br />m x <br />LA-a <br />.y <br />o <br />N � <br />w.m <br />sCb 3 <br />1° oy <br />5 �. <br />m � <br />N <br />C <br />eo <br />ry <br />0 <br />U <br />N <br />N <br />M <br />an <br />6 <br />o the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />8E <br />N <br />C <br />��IZ32 <br />a <br />m v <br />m _J <br />MLL LL <br />w <br />w0di <br />a <br />ae <br />W <br />Zga� <br />r9 2 0.5 <br />m <br />z <br />IL <br />N ;Zak <br />Z <br />o� <br />0 N <br />W <br />0p <br />z <br />zo <br />a <br />c� <br />U <br />Q� <br />4-1 <br />w LL <br />�U <br />- g <br />0 <br />W 8 <br />rQ <br />r- cn <br />as <br />U <br />w <br />�- E <br />>I <br />U £ X <br />51 <br />� 0 <br />a p1p <br />N 0 <br />rl- <br />col <br />M <br />y <br />Z <br />Z <br />a <br />LL <br />E E <br />Az® <br />'co <br />O <br />V <br />Z <br />O � <br />N <br />��� <br />�o <br />ry <br />C <br />$$ <br />OYU <br />gLL <br />Z <br />J <br />ab <br />W <br />W <br />S <br />ao <br />N� <br />� <br />S(�y <br />O <br />� 8 <br />al� <br />will <br />85 <br />85. <br />CO <br />= <br />12 <br />> CO <br />1L0 <br />L / <br />0) <br />m <br />r� <br />a- <br />co <br />:30 <br />r <br />Cr <br />O <br />Y <br />U) <br />N <br />m <br />L i <br />4-1M <br />N <br />Cy) <br />04 <br />00 <br />N <br />LO <br />OcoLO <br />E <br />4 <br />o <br />z <br />z <br />E r <br />N <br />a <br />U -J <br />Q p <br />JOB <br />NO : <br />22-06470 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.