My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6469 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6469 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 6:18:27 PM
Creation date
2/18/2025 3:28:21 PM
Metadata
Fields
Template:
Building Plans
Street #
6469
Location
Bar S Bar Trl
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br />ELECTRICAL SPECIFICATION 150A/2 L C INDOOR <br />PANEL CENTER <br />NOTES: 0 a14 to lights & outlets <br />ELECTRICAL CONTRACTOR 50 AMP X72 to appliances and GFl <br />150 AMP/ <br />MUST VERIFY WITH THE 2ooAMP 10 XatoRange <br />SPECIFICATIONS FOR THE TYPE 10 #6toHVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES.MAIJINT <br />so=zio <br />200=410 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND i <br />n act <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is Intended for bid purposes only. All work shall be done In strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed In accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range Is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />� 3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />—� FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />,Qt <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />[Ja <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />R9 <br />ELECTRIC METER <br />Man <br />ELECTRIC PANEL <br />_=I.=L <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />SECOND FLOOR ELECTRICAL PLAN — ELEV—Al <br />SCALE: Y4'=1'-0" <br />0 <br />d� <br />iP t O <br />ra ra-r C� <br />cc m <br />x <br />.s c t.a. Cl- <br />cc O r <br />to �. O <br />Uf <br />4 � N Y <br />a1 oa <br />d a d <br />c >: <br />m o <br />J <br />N <br />0 <br />N <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Resldentiel 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />Q $ M <br />d0 <br />00) <br />S <br />a <br />di r n 0 <br />46 <br />a C J <br />t� U. u. <br />LL Wa <br />0 <br />Z� <br />13 A <br />a he <br />It <br />W I- <br />0�mW <br />o <br />oD M Z <br />N <br />LL W <br />Q <br />(� <br />Z <br />y <br />f <br />W <br />❑❑ <br />(.D <br />Z tV <br />Z <br />J <br />— N <br />N z U <br />4-}J c„ <br />y <br />0 W <br />N <br />_w <br />1 a <br />N <br />� <br />w <br />s9 <br />Q <br />m "• <br />;� <br />o a <br />Wo <br />Z <br />ow <br />x�W <br />n' t <br />F <br />�p <br />m <br />� <br />hr3 <br />Qz <br />o <br />W <br />d <br />a <br />cow <br />o <br />L �- <br />�o <br />X <br />�► <br />o % <br />3 <br />O <br />> (0 <br />� <br />L0 <br />rn <br />m <br />.•-�L0 <br />Qcc <br />CL <br />L <br />H <br />M <br />j <br />Oco <br />p- Y <br />O <br />m <br />M <br />LO <br />¢I <br />N <br />CV <br />CD <br />00 O <br />Q <br />Li i <br />MLO <br />E <br />m <br />c <br />ui <br />o <br />Z <br />Z <br />c <br />E t— y <br />v15 <br />t`u <br />JOB <br />NO: 22-06470 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.