MIA}�MI•MIAMI-DADE COUNTY, FLORIDA <br />6-AA;6W METRO-DADE FLAGLER BUILDING <br />BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 <br />PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 <br />(305) 375-2901 FAX (305) 375-2908 <br />NOTICE OF ACCEPTANCE (NOA) www.buildin�codeonline.com <br />CECO Door Products <br />9159 Telecom Drive <br />Milan, TN 38358 <br />SCOPE: <br />This NOA is being issued under the applicable rules and regulations governing the use of construction materials. <br />The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted <br />by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by <br />the Authority Having Jurisdiction (AHJ). <br />This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control <br />Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to <br />have this product or material tested for quality assurance purposes. If this product or material fails to perform in <br />the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately <br />revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right <br />to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or <br />material fails to meet the requirements of the applicable building code. <br />This product is approved as described herein, and has been designed to comply with the Florida Building Cade, <br />including the High Velocity Hurricane Zone. <br />DESCRIPTION: Imperial Series 118070 / 407011 Outswing Commercial Steel Door <br />APPROVAL DOCUMENT: Drawing No "05-183", titled "Series 8070 Elevation Drawing Flush & Glazed <br />Imperial Doors", dated 07-26-05 and last revised on 12/20/05, sheets 1 through 16 of 16 prepared by Tilteco Inc., <br />signed and sealed by Walter A. Tillit Jr., P. E., bearing the Miami -Dade County Product Control Revision stamp <br />with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. <br />MISSILE IMPACT RATING: Large and Small Missile Impact Resistant <br />LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and <br />following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. <br />RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no <br />change in the applicable building code negatively affecting the performance of this product. <br />TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the <br />materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any <br />product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply <br />with any section of this NOA shall be cause for termination and removal of NOA. <br />ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by <br />the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall <br />be done in its entirety. <br />INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors <br />and shall be available for inspection at the job site at the request of the Building Official. <br />This NOA revises & supersedes NOA # 04-0611.04 consists of this page 1 and evidences page E-1 &E-2, as well <br />as approval document mentioned above. <br />The submitted documentation was reviewed by Ishaq I. Chanda, P.E. <br />Li <br />NOA No 05-0809.02 <br />Expiration Date: August 05, 2009 <br />Approval Date: January 12, 2006 <br />Page 1 <br />CECO Door Products. <br />NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED <br />A. DRAWINGS <br />1. Manufacturer's parts and sections drawings. <br />2. Drawing No "05-183", titled "Series 8070 Elevation Drawing Flush & Glazed <br />Imperial Doors", dated 07-26-05 and last revised on 12/20/05, sheets 1 through 16 of <br />16 prepared by Tilteco Inc., signed and sealed by Walter A. Tillit Jr., P. E . <br />B. TESTS (transferred from fde#04-0611.04) <br />1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 (except sp# 7 louver) <br />2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 <br />3) Water Resistant Test, per FBC, TAS 202-94 (Not Performed) <br />4) Large Missile Impact Test per FBC, TAS 201-94 <br />5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 <br />6) Forced Entry Test, per FBC 2411.3.2.1 (b) and TAS 202-94 <br />Along with marked -up drawings and installation diagram of outswing steel door, prepared by <br />Hurricane Test Laboratory, LLC, Test Report No. HTL-0345-0203-04 (HTL-04017), <br />(specimen # 1, 2, 3, & 5), dated 02/11/04 thru 02/21/04, signed and sealed by Vinu J. <br />Abraham, P.E <br />C. CALCULATIONS: <br />1. Anchor verification calculations, complying w/ FBC-2004, dated 08-15-2005, <br />prepared, signed and sealed by Walter A. Tillit Jr., P. E. <br />2. Anchor verification calculations, 05/24/04, prepared, signed and sealed by Walter A. <br />Tillit Jr., P. E. (transferred from file#04-0611.04) <br />D. QUALITY ASSURANCE <br />1. Miami Dade Building Code Compliance Office (BCCO). <br />E. MATERIAL CERTIFICATIONS (transferred from file#04-0611.04) <br />1. Test reports No. R5692/O1NK36633, issued by Underwriters Laboratories Inc. for <br />polyurethane foam cores "Surface burning characteristics" per ASTM E-84, dated <br />September 21, 2001, issued to BASF. Corp. <br />2. Test report No.01.10085.01.627, dated April 29, 2004, for "Self ignition test" per <br />ASTM 1929 D for the BASF polyurethane foam cores, issued by Southwest Reseaxeh <br />Institute, Texas. <br />3. Tensile Test report No. Job# 4DM-426, dated March 13, 2004, issued by Q C <br />Metallurgical, Inc, per ASTME-8, signed & sealed by Frank E. Grate, P.E <br />100 Max. <br />100 Max. <br />1 47 25/32 47 25/32 11 47 25/32 47 25/32 --� 12 Welded Comers <br />Caulk Frame Door Max Door Max <br />T2 Welded Comers p/6 (Sea Sheet 6/16) <br />Caulk Frame Door Max D/8 Door M x 8/3 (See Sheet 6/16) Perimeter <br />Perimeter <br />O+r�+ 1 '� 6 Locations (Typ.) <br />6 Locations (Typ,) 2 -"- <br />9 <br />C/ 30 Max �j F/4 / (D O F/4 33 <br />D.LO. @ 33 <br />1 32 Max © or ® or 3 <br />0 or or 3 D.LO. <br />-- -- — _- 83 112 6 <br />83 or Max Door Max <br />1Q Q Door � 7 Q 33 Max <br />r7 71 <br />33 Max 40 <br />40 <br />8 V4 - $ 9 <br />9 <br />N3 D/a N3 <br />AV3 D/S --� 13/3 711 Caulk Under 3/8 Undercut <br />11 Caulk Under 3/8 Undercut Qutswlna Dann Threshold <br />autlII Doors Threshold (interior VIMO <br />(Interior View) Rim Fyif Devices With Hardware Mullion <br />Rim Exit Devices With Hardware Mullion General Notes for 8070 Series Flush & Glazed Imperial Doors: <br />1. Double 8070 Series Imperial Outswing Commercial Steel Door w/series "SF" frame iamb and head, shown on this Product Approval Document (PA.D.) <br />100 Max, has been verified for compliance in accordance with the 2004 edition of the Florida Building Code. <br />Door may be Installed of High Velocity Hurricane Zones. <br />Design wind loads shall be determined as per section 1820 of the above mentioned code. In order to verify that components on this P.A.D., as tested, <br />tl 47 T2 /32 Welded Corners <br />25/ 32 47 25 were not overstressed, a 33% Increase in allowable stress for wind loads was SM used in their analysis. A CD-1.60 duration factor was used for wood <br />Caulk Frame Door Max poor M x fasteners verification. <br />Perimeter B/3 D/0 8/3 (See Sheet 6/16) This Door's adequacy for impact and cyclic resistance has been verified in accordance with section 1809.1.4 of the above mentioned code as per <br />TAS-201, TAS-202, TAS-203 protocols, as per HTL lab report #0345-0203-04 and as per submitted structural calculations, performed as per section <br />1612 of the Florida Building Code. <br />6 Locations (Typ.) --- 2. Des' n Pressure Rating: +70 pef, -70 psf ITKIR Door LJNOT Approved for water Infiltration <br />3. Minimum Frame Depth: 5 3/4" <br />C% 30 Max 30 Max F/4 4. See Sheet 7, 8, 9 de; 14 for Component NomenclatureD.L.O. © D.L.O. 33 <br />32 Max I 32 Max 5. See Sheet 5 for Anchor Details and Location <br />or ® or 3 D.LO. D.L.O. <br />S. All Dimensions are in inches <br />83 1/Hurricane17. <br />33 86 7. This Door DOES NOT require a Hurricane Protection Device <br />Door Max 8. (a) This P.A.D. prepared by this engineer is generic and does not provide Information for a site specific project; i.e. where the site conditions deviate <br />7 Max from the P.A.D. <br />L(D <br />(b) Contractor to be responsible for the selection, purchase and Installation Including life safety of this product, based on this PA.D., provided he/she <br />40 _ does not deviate from the conditions detailed on this document. Construction safety at site is the controctor's responsibility. <br />B t' (c) This P.A.D. will be considered invalid if altered by any means. PR9l1t1CT REVIEW <br />9 (d) Original P.A.D. shoo bear the date and original seal and signature of the professional engineer of record that prepared it. "OBWPb'hK11111111111411111'11111111" <br />Bomft cede <br />8/3 D/ e B/3 9. Door's manufacturer label shall be placed on the exposed surface of (B) or A,*pWm He OS-Og�-oZ <br />11 Couik Under 3/8 Undercut O�abelshall_ be placed for every opening. Label shall read as follows: g o <br />Outswing Doors Threshold 9159 Telecom Drive 7S C. <br />(Igterfor View) Milan, Tennessee Miami D Pivdre/Cos <br />Rim Exit With Hardware Mullion Mloml-Dade County Product Control Approved. <br />Bivisiae <br />MATERIAL SPECIFICATIONS: REVISIONS: 07-26-0 <br />GENERAL <br />(;;1— 8070 Series Elevation Drawing DRAWN BY: DATE: 12-19-0 <br />�'� IL E c o INe. Finish: Rust Inhibitive <br />Flush & Glazed imperial Doors 07-26-05 <br />DRAWING NUMBER: <br />TILUT TESTING a ENGINEERING COMPANY Primer, One Coat 05--183 <br />e N.11nth 1-1530.F.3XVIRI:(301 n�Al1,Ee _... CECE DD�R PRODUCTS <br />WALTER A. TILLIT Jr., P. E. ®-000e719 <br />MiAMI-DADE COUNTY P.E. SEAL/SIGNATURE/DATE WALTER a TLW jr., P• E.Sheet 1 Of 16 <br />fTORIOA Lie. 441e7 Milan Tennessee 38358 <br />isbaq I. chanda, P.E. <br />Product Control Examiner <br />NOA No 05-0809.IZ <br />Expiration Date: August 05, 2009 <br />Approval Date: January 12, 2006 <br />E-1 <br />Caulk Frame <br />Perimeter <br />33 <br />83 1 /2 -- <br />86 Door <br />MaxMax <br />33 <br />9 <br />52 Max.- <br />- 47 25/32 <br />Door Max <br />8/3-0-1 <br />4 30 Max <br />D.L.O. <br />L 32 Max _ <br />I D.L.O. <br />2)+19 0 <br />3 Locations (Typ.) <br />B/3 <br />3/8 Undercut <br />Outswing Door <br />(interior Vied <br />Rim Exit Device <br />CECO Door Products. <br />NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED <br />F. STATEMENTS (transferred from file# 04-0611.04) <br />1. Statement letter of anchor verification compliance to FBC-2004, dated July 29, 2005, <br />signed by Walter A. Tillit Jr., P. E. <br />2. Statement letter of conformance and "No fmancial interest", both dated June 09, 2004, <br />signed by Walter A. Tillit Jr., P. E. <br />3. Statement letter of compliance issued by Hurricane Testing Laboratory LLC., as part <br />of above referenced test report. <br />4. Statement letter dated 12/19/05, issued by Ceco Door products, requesting deleting of <br />wood installation options, signed by Larry Tyler. <br />G. OTHER <br />1. This NOA revises & supersedes NOA #04-0611.04, expiring August 05, 2009. <br />2. Letter from consultant stating that the product is in compliance with the Florida <br />Building Code (FBC) (transferred from fle#04-0611.04). <br />11 <br />T2 Welded Caulk Frame <br />Corners (See Perimeter <br />_ Sheet 6/16) <br />F/4 <br />- <br />-�or®ors <br />of <br />J <br />1 Caulk Under <br />Threshold <br />33 C/4 <br />83 1/2-------- <br />86 Door 11 <br />Max Max <br />33 ^ <br />9 <br />shaq I. chanda, P.E <br />Product Control Examiner <br />NOA No 05-0809.02 <br />Expiration Date: August 05, 2001 <br />Approval Date: January 12, 2006 <br />E-2 <br />52 Max.- <br />47 25/32 <br />Door Max <br />A/3 4-1 <br />0 <br />2)+19 O <br />3 Locations (Typ.) <br />15 I <br />A/3 <br />3/8 Undercut `"`11 <br />Outswing Door <br />(Interior View) <br />Rim Exit Device <br />MATERIAL SPECIFICATIONS: <br />-� I L E c o INc. Finish: Rust Inhibitive <br />Ta.uT TESTING & ENGINEERING COMPANY Primer, One Coat <br />eels N.W. Jeth sae vre0wu nanGA J31M <br />WALTER A. TILLIT Jr., P. E. *°� »-ts>o . Fa" : ]0l)R71-1e1I <br />E6-0006719 <br />MIAMI-DADE COUNTY P.E. SEAL/SIGNATURE/DATE WALTER A. TIWr Jr., P. E. <br />FLORVA Lk. J 44167 <br />General Notes for 4070 Series Flush & Glazed <br />Imperial Doors: <br />1, Single 4070 Series Imperial Outswing Commercial Steel Door <br />w/series "SF" frame jamb and head, shown on this Product <br />Approval Document (P.A,D.) has been verified for compliance in <br />accordance with the 2004 edition of the Florida Building Code. <br />Door may be installed at High Velocity Hurricane Zones. <br />Design wind loads shall be determined as per section 1620 of the <br />above mentioned code. In order to verify that anchors on this <br />T2 Welded <br />P.A.D., as tested, were not overstressed, a 33% increase in <br />Corners (See <br />allowable stress for wind loads was iZ used in their analysis. A <br />Sheet 6/16) <br />CD=1.60 duration factor was used for wood fasteners verification. <br />This Door's adequacy for impoct and cyclic resistance has been <br />9 <br />verified in accordance with section 1609.1.4 of the above <br />mentioned code as per TAS-201, TAS-202, TAS-203 protocols, as <br />per HTL lab report #0345-0203-04 and as per submitted <br />structural calculations, performed as per section 1612 of the <br />Florida Building Code, <br />F/4 <br />2. <br />Design Pressure Rating: +70 psf, -70 psf <br />3 or ® or :J <br />This Door IS NOT Approved for Woter Inflitration <br />3. Minimum Frame Depth: 5 3/4" <br />4. See Sheet 7, 8, 9 & 14 for Component Nomenclature <br />5. See Sheet 5A for Anchor Details and Location <br />6. All Dimensions are in inches <br />40 <br />7. This Door DOES NOT require a Hurricane Protection Device <br />8. (a) This P.A.D. prepared by this engineer is generic and does <br />not provide information for a site specific project; i.e, where the <br />site conditions deviate from the P.A.D. <br />n <br />(b) Contractor to be responsible for the selection, purchose and <br />ZJ <br />installation including life safety of this product, based on this <br />Caulk Under <br />11 <br />P.A.D., provided he/she does not deviate from the conditions <br />this document. Construction safety at site is the <br />Threshold <br />detailed on <br />contractor's responsibility. <br />(c) This P.A.D. will be considered invalid if altered by any means. <br />(d) Original P.A.D. shall bear the date and original seal and <br />PRODUCT REVISED <br />signature of the professional engineer of record that prepared it. <br />by ee�ptytK wN6 the Rorms <br />Cede 02 <br />9. Door's manufacturer label shall be placed on the exposed <br />� <br />surface of ®or <br />One label shall be placed for every opening. Label shall read as <br />follows: <br />CEC13 DWR PRODUCTS <br />9159 Telecom Drive <br />Milan, Tennessee <br />Miami -Dade County Product Control Approved. <br />REVISIONS: 00 RD0849 07-26-05 <br />4070 Series Elevation Drawing <br />GENVIAL <br />DRAWN BY: DATE: 12-19-05 <br />Flush & Glazed Imperial Doors <br />S.M./M.C.V. <br />107-26-05 <br />DRAWING NUMBER: <br />CECO DOOR PRODUCTS <br />05--183 <br />Milan Tennessee 38358 <br />Sheet 2 Of 16 <br />2 <br />L0 Io <br />O <br />LO <br />Lo I\ 0 <br />I <br />c <br />a- <br />00 <br />(� <br />U <br />c o <br />o `~ <br />O <br />s <br />CL <br />c <br />0 <br />U <br />Q- <br />O <br />' <br />a) 00 <br />CN <br />c t`7 <br />O <br />0 -� <br />U <br />� <br />Q) <br />a� o <br />D <br />} <br />c <br />° <br />} <br />o <br />� <br />s <br />C <br />c <br />L0 0 <br />L. <br />L <br />-4Ch <br />v <br />u7 Ch o <br />(E) copyright <br />0 <br />CL <br />E <br />M <br />CO O <br />N <br />-0 O, <br />— •L O <br />0 O O <br />N LO <br />O <br />�s 6 <br />O s1 0 <br />�O N c0 <br />revisions: <br />I ' <br />A <br />i <br />I <br />drawn: sc/dm/at <br />checked: rd <br />date: 3-21-08 <br />prof. no: P07-15B <br />A0903 <br />