My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6606 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6606 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 2:01:57 PM
Creation date
2/18/2025 3:28:51 PM
Metadata
Fields
Template:
Building Plans
Street #
6606
Location
Gall Blvd
Contractor
Sonny's BBQ
Building Plans - Permit #
7935
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FASTENERS SPACING AT END LAP <br />3611 <br />I <br />6 FASTENERS LOCATED AS -%M <br />MOXI" WOOD SCREW WITH <br />STEEL AND NEOPRENE WASHER <br />INTEFVEDIATE FASTENER SPACING <br />�11 <br />3 FASTENERS LOCATED AS SHOWN <br />L <br />- MOXI" WOOD SCREW WITH <br />STEEL AND NEOPRENE WASHER <br />MOXI" 12" OL, WOOD SCREW WITH <br />STEEL AND NEOPRENE WASHER <br />I" TAPE SEALER CONTINUOUS <br />Wr= 1 nc MCTAII irvorAl i <br />FASTENERS SPACING AT EAVE <br />�II <br />1 12 FASTENERS LOCATED AS SHOWN <br />FASTENERS At RIB 6" OL. MOXI" WOOD SCREW WITH <br />FOR FIRST 5'-0" UP ROOF STEEL AND NEOPRENE WASHER <br />b" <br />1" TAPE SEALER CONTINUOUS <br />PANEL END LAP <br />MOXI" WOOD SCREW WITH <br />STEEL AND NEOPRENE WASHER <br />30#FELT UNDERLAYMENT <br />REFERENCE DETAIL <br />FOR EAVE FLASHING <br />4 CLOSURE/TAPE SEALER INFO MATION <br />M t R-PANEL SYSTEM <br />roof detail - M panel fastener locations <br />not to scale <br />BERRIDGE M OR R PANEL <br />UPPER PANEL <br />PANEL FASTENERSt WITH METAL <br />BACKED NEOPRENE WASHER <br />INSIDE FOAM CLOSURE WITH <br />TAPE SEALER TOP AND BOTTOM <br />I ON 12 MIN. SLOPE <br />AWAY FROM UPER PANEL <br />T <br />UNDERLAYMENT <br />TRANSITION FLASHNGt 4° <br />END LAPS WITH CONTINUOUS <br />FASTENER 20" OL. <br />CAULK AT LAPS <br />PLACE A DAB OF CAULK AT <br />FASTENER LOCATION, DRIVE <br />BERRIDGE M OR R <br />FASTENER THROUGH CAULK <br />LOWER PANEL <br />AND CAULK FASTENER HEADS <br />SUB-FLASHNGt 4" END <br />LAPS WITH CONTINUOUS <br />CAULK AT LAPS <br />j <br />FASTENERSt 40" 0jC <br />SOLID SHEATHING <br />PANEL FASTENERSt WITH METAL <br />BACKED NEOPRENE WASHER <br />OUTSIDE FOAM CLOSURE WITH <br />TAPE SEALER TOP AND BOTTOM <br />FASTENERSt WITH METAL <br />BACKED NEOPRENE WASHER 20" OL. <br />L SOLID SHEATHING (BY OTHERS) To BE MINIMUM 1/2" <br />PLYWOOD OR EQUIVALENT IN <br />STRENGTH FOR HOLDING POWER OF FASTENERS. <br />2. ALL FELT UNDERLAYMENT, CAULKING, AND FASTENERS, ARE ITEMS TO BE FURNISHED <br />AND INSTALLED BY THE ROOFING INSTALLER AT THE DISCRETION OF THE ARCHITECT. <br />F = FINISH SIDE <br />F <br />1 loll MIN. <br />TRANSITION FLASHING SUB-FLASHNG <br />M t R-PANEL SYSTEM <br />roof detail - slope transitiion <br />not to scale <br />BERRIDGE M OR R PANEL — <br />RTOP WITH t <br />WS <br />PANEL FASTENER WITH METAL <br />BACKED NEOPRENE WASHER <br />GGAGLKEATT LAPS WITH <br />CONTV INUOUS <br />WALL PANEL <br />20 Oic. <br />SOLID SHEATHING <br />30#FELT <br />UNDERLAYMENT <br />L SOLID SHEATHING (BY OTHERS) TO BE MINIMUM 0' PLYWOOD OR <br />EQUIVALENT IN STRENGTH FOR HOLDING POWER OF FASTENERS. <br />2. TOLB FUR�l1SiD IN$TALI.ED MEN 8H AND R� ST L <br />AT THE DISCRETION OF THE ARCHITECT. <br />F = FINISH SIDE <br />1/2'I <br />EAVE FLASHING <br />M t R-PANEL SYSTEM <br />2 roof detail - eave <br />�01 <br />not to scale <br />FACTORY TABS <br />REVERSE <br />PLATES AND FASTENERS <br />INSTALLED TO SPECIFICATION <br />FASTEN MEMBRANE INTO <br />BOTH THE DECK AND THE <br />WALL SO THAT THE MATERIAL <br />IS NOT ALLOWED TO BRIDGE, <br />CUT TABS TO ALLOW FOR <br />SEALANT OR MASTIC AT THE <br />TERi11NATION POINT <br />I: THIS DETAIL CANNOT BE USED ON TAB SYSTEMS THAT <br />EXCEDE 60" TAB SPACINGS OR ON FULLY ADHERED ROOF SYSTEMS. <br />2: IT IS NOT RECOMMENDED THAT THIS DETAIL BE USED IF <br />MORE THAN 24" OF MATERIAL IS NEEDED TO FLASH A WALL <br />10 roof detail - aerp. wall flashin <br />not to scale <br />RIDGE/HIP CAPt 4" END LAPS WITH <br />CONTINUOUS CAULK AT LAPS. <br />POP RIVET AT LAPS AND CAULK <br />RIVET HEADS. <br />BERRIDGE M OR R PANEL <br />- PANEL FASTENER WITH MTL <br />BACKED NEOPRENE WASHER <br />FASTENERS <br />IT14 METAL <br />BAACCKEEDWNEOPRENE <br />WASHER 20" OL. <br />L730\FEL <br />T UNDERLAYP'EWT <br />SOLID SHEATHING <br />OUTSIDE FOAM CLOSURE WITH TAPE SEALER TOP <br />AND BOTTOM. USE EXPANDABLE FOAM CLOSURE <br />WITH TAPE SEALER TOP AND BOTTOM AT HIPS. <br />L SOLID SHEATHING (BY OTHERS) TO BE MINIMUM 1/2" PLYWOOD OR <br />EQUIVALENT N STRENGTH FOR HOLDNG POWER OF FASTENERS. <br />2. ALL FELTING UNDERLAYMENT, CAULKING, AND FASTENERS, ARE <br />ITEMS TO BE FURNISHED AND INSTALLED BY THE ROOFING <br />INSTALLER AT THE DISCRETION OF THE ARCHITECT. <br />F = FINISH SIDE <br />F <br />PJDGE/HIP CAP <br />M t R-PANEL SYSTEM <br />'7'� roof detail - ridae and hi <br />A7.01 / not to scale <br />NOTE I: FASCIA BAR AND COVER MAY BE USED �\ <br />N PLACE OF THE TERMINATION BAR 4 <br />NOTE 2: THE SUBSTRATE MUST BE FREE AND CLEAR <br />OF DEBRIS AT AND BELOW THE TERMINATION POINT. + <br />DURO-LAST PREFABRICATED PARAPET <br />WALL FLASHING <br />DECK <br />inside wall termination <br />not to scale <br />TYPICAL VENT PIPE <br />S.S. <br />STAINLESS STEEL BAND <br />POSITIONED 1/4-INCH <br />FROM THE TOP OF THE <br />STACK FLASHING <br />DURO-LAST <br />PREFABRICATED VENT <br />STACK FLASHING <br />DECK ' ' <br />H IF A LEAD FLASHING IS PRESENT ON THE PIPE, It MUST BE <br />REMOVED BEFORE A DURO-LAS STACK FLASHNG IS INSTALLED. <br />2: MEMBRANE ATTACHMENT AROUND THE PENETRATION WILL BE <br />THE SAME AS THE DECK MEMBRANE, MAX 18-INCHES ON CENTER <br />AND A MINIMUM ONE PLATE)FASTENER PER FLASHING. <br />// �11heat stack detail <br />A7.01 not to scale <br />tv <br />GABLE CAUELK AT LAPS <br />CONT. BEAD of CAULK <br />LAPS WITH CONTLAULKD <br />Tj \ <br />FASTENER WITH METAL <br />BACKED NEOPRENE <br />WASHER 20" O.G <br />RIDGE M OR R PANEL <br />FASTENERSt20" <br />OL. MAX. <br />L0 30 FELT UNDERLAYMENT <br />- TOP LAYER OF FELT TO BE <br />PARALLEL WITH ROOF SLOPE <br />— FASTENERSt 20" OL. MAX <br />SOLID SHEATHhJG <br />L SOLID SHEATHING (BY OTHERS) TO BE MIN" 1/1" PLYWOOD OR <br />EQUIVALENT IN STRENGTH FOR HOLNG POWER OF FASTENERS. <br />2. ALL FELT UNDERLAYMENT, CAULKING, AND FASS, ARE ITEMS <br />TO BE FURNISHED AND INSTALLED BY THE ROOFING INSTALLER <br />AT THE DISCRETION OF THE ARCHITECT. <br />F ■ FINISH SIDE <br />F > <br />"00( <br />' VL <br />GABLE CHANNEL GABLE FLASHNG <br />M t R-PANEL SYSTEM <br />i4� roof detail - aable <br />A7.01 not to scale <br />COUNTERFLASHNG <br />/ v ° <br />� r � <br />b <br />DURO-LAST SEALANT + ° <br />v <br />D <br />O <br />DURO-LAST DURO-FLASH TM f <br />b <br />Lul <br />DURO-LAST FASTENERS° b <br />6-INCHES ON CENTER MAX , <br />° <br />D <br />r <br />durolast duro-flash detail <br />not to scale <br />CANTED - 4" BASE CLEAT <br />I: 0 THE FASTENERS ARE TO PENETRATE THROUGH THE COPING <br />CAP, THEN RUBBER GROMIMETED FASTENERS MUST BE USED. <br />2: INDIVIDUAL SECTIONS OF COPING CAP AND COPING CAP <br />ACCESSORIES MUST BE JOINED BY A SPLICE PLATE <br />I ALL JOINTS ARE TO BE SEALED WITH DURO-LAST CAULKS <br />AND/OR SEALANTS. <br />// �12coaina caa detail <br />A7.01 not to scale <br />tv <br />CAP FLASHNGt 4" END LAPS <br />FASTENERS AT LAPS <br />WITH CONTNUOUS CAULK AT LAPS. <br />*0 STAGGERED t <br />POP RIVET TO COUNTER FLASHING 40 <br />20 O.C, AND CAULK <br />O.C.MAX. CAULK ALL RIVET HEADS <br />FASTENER HEADS <br />ON 12 <br />FASTENERSt 20" OL. MAX <br />COUNTERFLASHNGt 4" END LAPS <br />i ` ' <br />30 FELT UNDERLAYMENT <br />WITH CONTINUOUS CAULK AT LAPS <br />SUB-FLASHhNGt 4" END LAPS WITH <br />CONTINUOUS CAULK AT LAPS <br />11-� <br />FASTENERSt WITH pMETAL <br />30 FELT UNDERLAYMENT <br />WA 'OC. MAX <br />R 40 <br />BERRIDGE M OR R PANEL <br />OUTSIDE FOAM CLOSURE/ PANEL FASTENERSt WITH <br />TAPE SEALER TOP �x . / ;' METAL BACKED <br />AND BOTTOM / ; i NEOPRENE WASHER <br />FASTENERSt WITH METAL <br />BACKED NEOPRENE <br />WASHER 20" O.C. MAX <br />SOLID SHEATHING <br />L SOLID SHEATHNG (BY OTHERS) TO BE MINIMUM 1/2' PLYWOOD OR EQUIVALENT IN <br />STRENGTH FOR HOLDING POWER OF FASTENERS. <br />2. ALL FELT UNDERLAYMENT, CAULKING, AND FASTENERS, ARE ITEMS TO BE FURNISHED <br />AND INSTALLED BY THE ROOFING INSTALLER AT THE DISCRETION OF THE ARCHITECT. <br />F ■ FINISH SIDE <br />F I� <br />F <br />1/2" <br />COUNTERFLASHING SUB -FLASHING CAP FLASHNCx� <br />M t R-PANEL SYSTEM <br />�5� roof detail - as ra aet <br />AL7V not to scale <br />DURO-LAST PREFABRICATED <br />CUSTOM CURB FLASHING POURABLE SEALER DEPTH <br />112 TO 3/4 INCHES <br />{ <br />G + <br />gc <br />a a a <br />a <br />a d e d t <br />�X <br />u e <br />DECK FILLER-I.E. MORTAR <br />CONCRETE OR INSULATION <br />L WATER MUST NOT BE ALLOWED TO POND WITHIN THE PITCH POCKET. BE <br />SURE THAT THE POURABLE SEALER IS LEVEL WITH THE TOP OF THE CURB. <br />2. PERIMETER FASTENING OF THE DECK MEMBRANE WILL BE THE SAME <br />FASTENING PATTERN AS THE FIELD MEMBRANE, MAX 18-INCHES ON CENTER <br />AND NO LESS THAN ONE FASTENER PER SIDE. <br />8 itch Ian d eta i I <br />�01 <br />not to scale <br />DURO-LAST PREFABRICATED <br />PARAPET WALL PLASHNG TERMINATION BAR <br />DECK <br />(o'13 outside wall term. <br />A7.01 not to scale <br />oO v �o <br />LO o <br />^' <br />"C <br />AO <br />1 1 0 <br />> <br />W <br />aa'0 <br />• <br />o0 <br />v v <br />c a <br />0 <br />O <br />rn <br />s <br />a <br />c <br />C <br />c <br />v <br />Q <br />a� 00 <br />��. <br />C <br />C:V <br />M <br />O <br />o � <br />U <br />� <br />'� <br />N O <br />c .-- <br />0 <br />V <br />O <br />r-. <br />V <br />C <br />c <br />0 <br />4 :) <br />p <br />un <n O <br />(D copyright <br />CV <br />I- <br />LO <br />m <br />CO <br />O o <br />> -0 <br />j L <br />O O <br />� N <br />°a) s <br />'o <br />o s <br />%o a <br />1-0N <br />revisions: <br />n <br />�i A <br />A <br />drawn: sc/dm/at <br />checked: rd <br />date: 3-21-08 <br />proj. no: P07-15B <br />A7.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.