GENERAL NOTES: <br />1. CONTRACTOR IS RESPONSIBLE FOR AND SHALL VERIFY AND <br />COORDINATE ALL DIMENSIONS AND DETAILS BEFORE PROCEEDING WITH <br />WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE <br />ATTENTION OF THE ARCHITECT AND ENGINEERS. <br />2. DETAILS SHOWN IN ANY SECTION APPLY TO ALL SIMILAR SECTIONS AND <br />CONDITIONS UNLESS NOTED OTHERWISE. <br />3. CONTRACTOR SHALL FULLY BRACE AND OTHERWISE PROTECT ALL WORK <br />IN PROGRESS UNTIL THE BUILDING IS COMPLETED. <br />4. ALL STRUCTURAL ITEMS FOR THIS PROJECT HAVE BEEN DESIGNED IN <br />ACCORDANCE WITH APPROPRIATE PROVISIONS OF EACH OF THE <br />FOLLOWING: <br />A. THE FLORIDA BUILDING CODE, 2004 EDITION WITH 2O05 AND 2006 <br />REVISIONS. <br />B. ACI STANDARD 318-02 BUILDING CODE REQUIREMENTS FOR <br />REINFORCED CONCRETE. <br />C. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ACI <br />530-05/ASCE 5-02). <br />D. AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND <br />ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" NINTH EDITION. <br />A. AMERICAN FOREST AND PAPER ASSOCIATION, NATIONAL DESIGN <br />SPECIFICATION 2001 EDITION. <br />5. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH <br />THE SPECIFICATIONS AND THE ARCHITECTURAL AND MECHANICAL <br />DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ARCHITECT PRIOR TO <br />PERFORMING WORK. IN CASE OF CONFLICT THE MOST STRINGENT <br />CONDITION SHALL APPLY. <br />6. ALL DIMENSIONS MUST BE COORDINATED WITH ARCHITECTURAL <br />DRAWINGS AND WITH EQUIPMENT MANUFACTURER (I.E. WINDOW, DOOR, <br />AIR HANDLER, ETC.). CONTRACTOR MUST OBTAIN AN ARCHITECTURAL <br />DIRECTIVE IN CASE OF ANY CONFLICT. REFER TO ARCHITECTURAL <br />DRAWINGS FOR DIMENSIONS NOT SHOWN IN STRUCTURAL DRAWINGS. <br />CONCRETE AND REINFORCING: <br />1. ALL CONCRETE WORK SHALL CONFORM TO THE LATEST ACI "BUILDING <br />CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI-318". <br />2. ALL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE <br />STRENGTHS AS INDICATED BELOW: <br />CONCRETE MAX WATER �E <br />STRENGTH CEMENT RATIO AGGREGATE LOCATION USED <br />5000 PSI 0.42 STONE CONCRETE U.N.O. <br />4000 PSI 0.45 STONE FOUNDATIONS <br />3000 PSI 0.52 STONE SLAB ON GRADE <br />3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, NEW BILLET <br />STEEL, DEFORMED BARS, CONFORMING TO ASTM A-615, GRADE 60. <br />ALL BARS SHALL BE SECURELY SUPPORTED AND WIRED IN PLACE. <br />PRIOR TO POURING CONCRETE. ALL REINFORCING STEEL TO BE WELDED <br />SHALL CONFORM TO ASTM A-706. <br />4. ALL WELDED WIRE FABRIC (W.W.F.) IN FLAT SHEETS ONLY AND SHALL <br />CONFORM TO ASTM A-185. <br />5. UNLESS NOTED, ALL BARS MARKED CONTINUOUS SHALL BE SPLICED AT <br />ALL LAP POINTS AND CORNERS AND DEVELOPED AT NON -CONTINUOUS <br />ENDS AS PER TYPICAL DETAILS. SPLICE CONTINUOUS TOPS BARS AT <br />CENTER BETWEEN SUPPORTS AND SPLICE CONTINUOUS BOTTOM BARS <br />AT SUPPORTS. <br />6. CONCRETE COVER FOR REINFORCING BARS SHOWN IN TYPICAL DETAILS. <br />7. UNLESS NOTED, TEMPERATURE REINFORCING (ASTM A-615-60) TO BE <br />0.0018 X CONCRETE AREA. <br />8. PROVIDE #4 ® 12" O.C., WITH STANDARD HOOK, TOP BARS IN ALL <br />SLABS AT DISCONTINUOUS ENDS UNLESS OTHERWISE NOTED ON PLANS. <br />LENGTH OF BARS 1 /4 OF SPAN, MINIMUM 3'-0 UNLESS OTHERWISE <br />NOTED PROVIDE #4 m 12" O.0 IN ALL CANTILEVERS. BAR LENGTH <br />SHALL BE CANTILEVER SPAN PLUS 10'-0" PLUS STANDARD HOOK AT <br />CANTILEVER ENDS. <br />9. WHERE PIPE SLEEVES (UP TO 2" IN DIAMETER) PASS THROUGH <br />CONCRETE BEAMS, PROVIDE ADDITIONAL STIRRUP EACH SIDE OF <br />SLEEVE, SLEEVES FOR PIPES 2" IN DIAMETER OR LARGER MUST BE <br />STEEL OR CAST IRON, AND THE LOCATION MUST BE APPROVED BY THE <br />STRUCTURAL ENGINEER. <br />10. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED JUST <br />BEFORE PLACING NEW CONCRETE IN ACCORDANCE WITH THE BUILDING <br />CODE. <br />11. FOR CHAMFER OF EXPOSED CORNERS OF BEAMS AND/OR COLUMNS, <br />SEE ARCHITECTURAL DRAWINGS. <br />12. CONTRACTOR SHALL COORDINATE PLACEMENT OF, OR BOX OUT FOR, <br />ALL PIPE SLEEVES, OPENINGS, ETC, REQUIRED FOR VARIOUS TRADES. <br />13. CONTRACTOR SHALL COORDINATE AND NOTIFY OTHER TRADES IN <br />SUFFICIENT TIME TO ALLOW THEM TO SET ANCHORS, INSERTS, BOLTS, <br />HANGERS, ETC., AS REQUIRED FOR THEIR USE. <br />14. SEE ARCHITECTURAL DRAWINGS FOR DETAILS OF FLASHING REGULATES, <br />FASCIA DETAILS, ETC. <br />15. UNDER NO CIRCUMSTANCES SHALL CONCRETE BE PUMPED THROUGH <br />ALUMINUM PIPES. CONCRETE SHALL NOT BE PLACED IN CONTACT WITH <br />ALUMINUM, ALUMINUM MIXING DRUMS, TRUCK MIXERS, BUGGIES, <br />CHUTES, CONVEYORS, TREMIE PIPES, AND OTHER EQUIPMENT MADE OF <br />ALUMINUM SHALL NOT BE USED ON THIS PROJECT. <br />16. SLUMPS OF OVER 4 INCHES WILL NOT BE PERMITTED UNLESS THE <br />HRWR ADMIXTURE (SUPER PLASTICIZER) IS USED. MAXIMUM SLUMP IS <br />THEN 8 INCHES UNLESS OTHERWISE DIRECTED BY THE ENGINEER. <br />17. NO ADMIXTURE SHALL BE USED IN CONCRETE EXCEPT WITH THE <br />PERMISSION OF THE ENGINEERS AND AFTER LABORATORY DESIGN MIX <br />APPROVAL. ALL ADMIXTURES SHALL CONTAIN NO MORE CHLORIDE IONS <br />THAN ARE PRESENT IN MUNICIPAL DRINKING WATER. <br />18. WATER REDUCING ADMIXTURE SHALL CONFORM TO THE ASTM C-494, <br />TYPE A, AND SHALL BE USED IN ALL CONCRETE. <br />19. AIR ENTRAINING ADMIXTURE SHALL CONFORM TO ASTM C260. AIR <br />CONTENT OF CONCRETE SHALL BE USED AS FOLLOWS: <br />A. FOR CONCRETE EXPOSED TO SOIL AND/OR WEATHER, 57. <br />B. FOR INTERIOR WALLS, COLUMNS, AND SLABS, 3%. <br />20. FLY ASH - ASTMC618, TYPE C OR TYPE F SHOULD BE USED BUT NOT <br />TO EXCEED 20X <br />21. ALL EXPOSED CONCRETE SLABS SHALL RECEIVE A CURING COMPOUND. <br />THE CURING COMPOUND SHALL CONFORM TO ASTM C309 AND SHALL <br />HAVE 30% SOLIDS MINIMUM. WATER/BLANKET CURING AS PER ACI <br />RECOMMENDATION MAY BE USED AS ALTERNATE. <br />GENERAL STRUCTURAL NOTES <br />FOUNDATION NOTES: <br />1. FOUNDATIONS FOR THIS PROJECT HAS BEEN DESIGNED ASSUMING THE <br />SOIL IS SUITABLE TO SUPPORT 2000 PSF SPREAD FOOTINGS. <br />CONTRACTOR MUST VERIFY SOIL CONDITIONS AND BEARING CAPACITY <br />AND SHOULD CONTRACT A GEOTECHNICAL ENGINEER TO VERIFY THE <br />ASSUMED BEARING PRESSURE. ANY DISCREPANCY MUST BE INFORMED <br />TO ENGINEER OF RECORD WITH GEOTECHNICAL ENGINEER <br />RECOMMENDATIONS TO OBTAIN A REVISED FOUNDATION PLAN. <br />2. FILL AND SUBGRADE PREPARATION SHALL BE AS NEEDED TO OBTAIN <br />THE SAFE BEARING PRESSURE INDICATED ON NOTE 1. ALL ORGANICS <br />AND UNSUITABLE SOIL SHOULD BE REMOVED AND A MINIMUM OF 98% <br />MUST BE OBTAIN UNLESS GEOTECHNICAL ENGINEER RECOMMENDATIONS <br />ALLOW A LOWER PERCENT OF COMPACTION. <br />3. ALL COLUMN FOOTINGS SHALL BE CENTERED UNDER COLUMN <br />CENTERLINES UNLESS OTHERWISE NOTED. <br />4. BACKFILLING AGAINST FOUNDATION WALLS SHALL BE DONE CAREFULLY <br />WITH SMALL COMPACTION EQUIPMENT, AFTER SLABS ON GROUND ARE <br />IN PLACE AND CONCRETE HAS SET. NO TRUCKS, BULLDOZERS, ETC. <br />SHALL BE ALLOWED CLOSER THAN 6'-0" TO ANY FOUNDATION WALL. <br />ANY WALL 3'-0" OR HIGHER MUST BE BRACED DURING THE <br />CONSTRUCTION PROCESS. <br />5. NO FOUNDATIONS SHALL BE PLACED ABOVE 1 VERTICAL ON 2 <br />HORIZONTAL SLOPES EXTENDED FROM THE CLOSEST EDGE OF ANY <br />UNDISTURBED SOIL OR OTHER FOUNDATION STRUCTURE. BOTTOM OF <br />FOOTINGS SHALL NOT BE LESS THAN 1'-O" BELOW EXISTING GRADE <br />(U.N.O.). <br />6. FOR FOUNDATIONS SIZE AND REINFORCING SEE SCHEDULE. <br />7. ELEVATOR PIT DIMENSIONS = VERIFY WITH ELEVATOR MANUFACTURERS <br />APPROVED SHOP DRAWINGS. <br />8. WATER PROOFING MATERIALS SHALL BE PROVIDED ON ALL SIDES AND <br />BOTTOM OF ELEVATOR CORE AND ESCALATOR PIT. <br />9. CONTRACTOR SHALL TREAT SOIL BENEATH BUILDING FOR TERMITES. <br />MASONRY: <br />1. DESIGN AND CONSTRUCTION SHALL CONFORM TO BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530/02 ASCE 5-02). <br />AND SPECIFICATIONS FOR MASONRY STRUCTURES ACI 530.1-02 / <br />ASCE 6-02. <br />2. MINIMUM NET COMPRESSIVE STRENGTH OF BLOCK ASSEMBLY SHALL BE <br />1500 P.S.I. (f m) MORTAR FOR MASONRY SHALL BE TYPE "S" OR "M". <br />3. FOR ALL EXTERIOR AND INTERIOR BEARING, BED JOINTS ARE TO COVER <br />100% OF THE MASONRY SURFACES AND ALL HEAD JOINTS ARE TO <br />COVER 100% OF THE PROJECTED AREA OF THE FACE SHELLS. <br />4. FILL ALL CELLS AS REQUIRED WITH 3000 P.S.I. GROUT. SLUMP SHALL <br />BE 8 TO 11 INCHES. SUBMIT DESIGN MIX FOR APPROVAL. <br />5. MINIMUM HORIZONTAL REINFORCING SHALL BE 9 GAGE HOT DIP <br />GALVANIZED TRUSS OR LADDER TYPE JOINT REINFORCING AT 16" O.C., <br />PROVIDE MANUFACTURE "T" AND "L" SHAPES FOR INTERSECTIONS AND <br />CORNERS, (MINIMUM LAP 8"). <br />6. MINIMUM VERTICAL REINFORCING SHALL BE 1-#5 ® 48" OR 1-#4 <br />32" O.C., (U.N.O.). <br />7. PROVIDE ADDITIONAL VERTICAL REINFORCING BAR AT EVERY CORNER, <br />INTERSECTION, CONTROL JOINT, AND OPENING EDGES (U.N.O.). <br />8. MINIMUM SPLICE FOR VERTICAL REINFORCING IS SHOWN IN DETAIL <br />4-023, SPLICE FOR HORIZONTAL TRUSS TYPE REINFORCING = 12". <br />9. WALLS ARE DESIGNED TO BE BRACED BY FLOOR OR ROOF MEMBERS, <br />CONTRACTOR SHALL PROVIDE TEMPORARY BRACING DURING <br />CONSTRUCTION. <br />10. ALL CELLS BELOW FIRST FLOOR FINISHED ELEVATION MUST BE FULLY <br />GROUT FILLED. <br />11. ALL KNOCK OUT BLOCK HORIZONTAL BARS SHALL HAVE CORNER BARS <br />AT ALL CORNERS AND WALL INTERSECTIONS. SIZE AND NUMBER OF <br />CORNER BARS SHALL BE SAME AS HORIZONTAL BARS. <br />12. ALL INTERSECTING WALLS AND CORNER WALLS SHALL BE LAID IN AN <br />OVERLAPPING MASONRY BONDING PATTERN, WITH ALTERNATE UNITS <br />HAVING A BEARING OF NOT LESS THAN 3 INCHES ON UNIT BELOW. <br />STRUCTURAL STEEL, <br />1. ALL STRUCTURAL STEEL WORK SHALL BE FABRICATED AND ERECTED IN <br />ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS. <br />2. STRUCTURAL STEEL SHALL CONFORM TO: <br />WIDE FLANGE (WF) ASTM A992 (50 KSI) <br />SHAPES (L,T,C,PL) ASTM A36 <br />STRUCTURAL TUBE (HSS) ASTM A500 (46 KSI) <br />STEEL PIPE (HSS) ASTM A500 (42 KSI) <br />ANCHOR BOLTS ASTM A36 U.N.O. IN PLANS, <br />OR SECTIONS. <br />FRAMING BOLTS ASTM A325 OR A490 <br />SHEAR STUDS ASTM A108 <br />WELDING ELECTRODES E70XX <br />3. ALL HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM SPECIFICATION <br />A325 AND SHALL BE PROVIDED WITH HARDENED WASHERS UNDER THE <br />TURNED ELEMENT (NUT OR BOLT HEAD). <br />4. INSTALLATION AND TIGHTENING OF ALL HIGH STRENGTH BOLTS SHALL <br />CONFORM TO THE "SPECIFICATION FOR STRUCTURAL JOINTS USING <br />ASTM A325 OR A490 BOLTS". <br />5. SHOP CONNECTIONS MAY BE WELDED OR HIGH STRENGTH BOLTED. ALL <br />BOLTS SHALL BE 3/4" DIAMETER MINIMUM. ALL CONNECTIONS SHALL <br />CONFORM TO THE TYPICAL CONNECTION DETAILS SHOWN ON THE <br />PLANS UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. <br />6. ALL FIELD CONNECTIONS SHALL BE BOLTED WITH HIGH STRENGTH <br />BOLTS, SLIP -CRITICAL (FRICTION) TYPE. <br />7. ALL WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY <br />CODE, ANS01.1, ALL WELDING SHALL BE PERFORMED USING E70XX <br />U.N.O. <br />8. CUTS, HOLES, COPINGS, ETC. REQUIRED IN STRUCTURAL STEEL <br />MEMBERS FOR THE WORK OF OTHER TRADES SHALL BE SHOWN IN THE <br />STRUCTURAL STEEL SHOP DRAWINGS AND SHALL BE MADE IN THE <br />SHOP. HOLES SHALL BE REINFORCED AS REQUIRED BY THE ENGINEER. <br />9. BURNING OF HOLES, CUTS, ETC. IN STRUCTURAL STEEL MEMBERS IN <br />THE FIELD WILL NOT BE PERMITTED, EXCEPT WITH THE SPECIFIC <br />APPROVAL OF THE ENGINEER. <br />10. ALL STEEL MEMBERS EXPOSED TO WEATHER (SUCH AS LINTELS, DOOR <br />JAMBS, ETC.) SHALL BE GALVANIZED. <br />11. FOR MISCELLANEOUS STEEL, SEE ARCHITECTURAL DRAWINGS. <br />12. ANY STEEL MEMBERS REQUIRED BY THE ELECTRICAL OR MECHANICAL <br />TRADES FOR THE SUPPORT OF THEIR EQUIPMENT, WHICH ARE NOT <br />SHOWN ON ARCHITECTURAL OR STRUCTURAL DRAWINGS, SHALL BE <br />PROVIDED BY THE TRADE REQUIRING SUCH SUPPORT. <br />13. SEE SPECIFICATIONS FOR PAINTING OF STRUCTURAL STEEL. ALL <br />FABRICATION AND ERECTION MARKS SHALL BE COVERED DURING FIELD <br />TOUCH-UP PAINTING. <br />14. ALL CONNECTIONS TO BE DOUBLE ANGLE FRAMED BEAM CONNECTION <br />PER AISC UNLESS NOTED OTHERWISE. ALL BOLTS TO BE 3/4" MINIMUM <br />DIAMETER UNLESS NOTED OTHERWISE. SHOP CONNECTIONS MAY BE <br />WELDED OR BOLTED. WELDS ARE TO BE EQUAL IN STRENGTH TO <br />BOLTS. <br />15. DESIGN CONNECTIONS FOR THE MAXIMUM SHEAR (V IN KIPS) LISTED IN <br />THE TABLES FOR "ALLOWABLE UNIFORM LOADS IN KIPS FOR BEAMS <br />LATERALLY SUPPORTED" AT THE BOTTOM OF EACH PAGE IN THE <br />"PROPERTIES AND REACTION VALUES", PART 2 OF THE LATEST EDITION <br />OF THE AISC "MANUAL OF STEEL CONSTRUCTION". <br />16. WHEN STEEL MEMBERS ARE WELDED TO EMBED PLATES IN CONCRETE, <br />WELDING PROCESS SHOULD BE PERFORMED IN SUCH WAY THAT EMBED <br />PLATE DOES NOT OVERHEAT AND EXPAND. SUCH EXPANSION WILL <br />CRACK THE CONCRETE SURROUNDING THE EMBED PLATE AND MAY <br />WEAKEN THE STRUCTURAL CAPACITY OF THE CONNECTION. WE <br />RECOMMEND TO PROVIDE SEVERAL SINGLE PASSES TO BUILT UP THE <br />WELD SIZE REQUIRE WITH COOLING OFF PERIODS TO AVOID THE EMBED <br />PLATE EXPANSION. UNDER NO CIRCUMSTANCES PROVIDE MORE THAN 6" <br />OF 1 /4" WELD WITHOUT ALLOWING A COOLING OFF PERIOD. <br />STEEL JOIST, <br />1. STEEL JOIST CONSTRUCTION SHALL CONFORM TO THE LATEST <br />SPECIFICATIONS OF, AND THE JOISTS SHALL BE APPROVED BY, THE <br />STEEL JOIST INSTITUTE. <br />2. UNLESS OTHERWISE NOTED, BEAR SHORT SPAN JOISTS MINIMUM OF <br />2-1/2" ON STEEL BEAMS AND BEAR LONG SPAN JOIST MINIMUM OF 4" <br />ON STEEL SUPPORTS. IN CASES WHERE JOISTS BEAR ON BEAMS FROM <br />ONE SIDE ONLY, JOIST SEATS SHALL EXTEND A MINIMUM OF 1" PAST <br />THE CENTERLINE OF SUPPORTING BEAM. <br />3. ALL JOISTS BEARING ON BEAMS SHALL BE WELDED OR BOLTED TO <br />THOSE BEAMS. <br />4. PROVIDE BRIDGING FOR ALL JOISTS AS SHOWN ON PLAN BUT NOT LESS <br />THAN WHAT IS REQUIRED BY THE STEEL JOIST INSTITUTE OR THE <br />STEEL JOIST DESIGNER. BRIDGING SHALL CONSIST OF MINIMUM 1-1/4" <br />X 1-1/4" X 1/8" ANGLES, (U.N.O.). <br />5. ALL BRIDGING SHALL BE PROVIDED AND INSTALLED BY JOIST SUPPLIER. <br />6. ALL CLIPS AND CONNECTIONS SHALL BE SHOP WELDED. <br />7. NO FIELD WELDING TO BAR JOISTS EXCEPT ITEMS SPECIFICALLY SHOWN <br />ON STRUCTURAL DRAWINGS SHALL BE ALLOWED WITHOUT SPECIFIC <br />PERMISSION FROM THE ENGINEER. <br />8. NO JOIST SHALL BE FIELD SPLICED. <br />9. MAXIMUM DEFLECTION OF STEEL JOISTS = L/240. <br />10. FOR PAINTING OF STEEL JOIST, SEE SPECIFICATIONS. <br />11. JOIST MANUFACTURER SHALL SUBMIT WITH THE SHOP DRAWINGS HIS <br />CATALOG USED FOR THE MANUFACTURE OF JOISTS, INDICATING THE <br />LOAD TABLES AND SIZES OF ALL MEMBERS USED. <br />12. NO LOADS EXCEEDING 40 POUNDS MAY BE HUNG FROM JOISTS <br />WITHOUT SPECIFIC PERMISSION FROM THE STRUCTURAL ENGINEER. <br />LOADS LESS THAN 40 POUNDS MAY BE HUNG AT PANEL POINTS ONLY. <br />ANY COST INVOLVED IN REINFORCING OF JOISTS SHALL BE BORNE BY <br />THE PRIME CONTRACTOR REQUIRING ADDED LOADS. <br />13. ALL SHORT SPAN JOISTS, AND DEEP LONG SPAN JOISTS SHALL HAVE <br />UNIFORM CROSS SECTION, WITH STANDARD DEAD LOAD CAMBER. ROOF <br />PITCH IS ACCOMPLISHED BY SLOPED JOISTS AND SUPPORT BEAMS. <br />ADJUST JOIST SEATS AS SHOWN ON DRAWINGS. <br />14. FOR SPECIFIC JOIST ENDS, SEE ROOF SECTIONS. <br />15. RIGID CONNECTIONS OF BOTTOM CHORDS OF JOISTS TO COLUMNS <br />SHALL BE MADE ONLY AFTER THE APPLICATION OF ALL THE DEAD <br />LOADS. PROVIDE LOOSE BOLTED CONNECTION OF THESE BOTTOM <br />CHORDS DURING ERECTION. <br />STEEL ROOF DECK: <br />1. STEEL ROOF DECK SHALL BE A MINIMUM OF 1-1/2" - 20 GAGE WIDE <br />RIB FOR SPANS UP TO 6'-0" OR 3" TYPE N - 20 GAGE FOR SPANS <br />UP TO 12'-0" . THE SIZE, TYPE AND GAGE INDICATED ABOVE SHOULD <br />BE USED UNLESS A DIFFERENT ONE IS INDICATED IN THE ROOF <br />FRAMING NOTES OF THE ROOF PLAN DRAWING. <br />2. ALL STEEL ROOF DECK SHALL BE HOT -DIPPED GALVANIZED G90 AS <br />PER ASTM SPECIFICATIONS. <br />3. ALL STEEL ROOF DECK SHALL BE CAPABLE OF SUPPORTING ALL <br />CONSTRUCTION LOADS. <br />4. ALL STEEL ROOF DECK SHALL BE CONTINUOUS OVER FOUR OR MORE <br />STRUCTURAL SUPPORTS (I.E. DECK SHOULD BE DETAILED FOR A THREE <br />SPAN CONDITION.) <br />5. STEEL ROOF DECK SHALL HAVE NESTING SIDE LAPS (ATTACHED BY <br />MECHANICAL MEANS) AT THE CENTER OF EACH SPAN 30" O.C.., <br />WHICHEVER IS LEAST DIMENSION. <br />6. IF DECK IS CUT IN SINGLE SPAN CONDITION, EACH END OF SUCH <br />SECTIONS SHALL BE WELDED TO ITS SUPPORT THROUGH WELDING <br />WASHERS IN THE BOTTOM OF EACH RIB. <br />7. IN AREAS WHERE THE DECK IS CUT AS PER NOTE 5, THE GAGE OF <br />THE SINGLE SPAN DECK SHALL BE ADJUSTED UPWARDS AS REQUIRED <br />BY THE ENGINEER TO SUPPORT THE LOADS. <br />8. ANY ELECTRICAL WORK WEIGHING MORE THAN 5 PSF SHALL BE HUNG <br />FROM STEEL BEAMS ONLY. FOR HANGERS, SEE SPECIFICATIONS. ALL <br />MECHANICAL WORK AND PIPING SHALL BE HUNG FROM STEEL BEAMS. <br />SEE STRUCTURAL STEEL NOTE 12 (OF STRUCTURAL STEEL NOTES) FOR <br />ADDITIONAL STEEL REQUIRED BY MECHANICAL/ELECTRICAL TRADES TO <br />SUPPORT THEIR EQUIPMENT. <br />9. METAL DECK CONTRACTOR TO PROVIDE 18 GAGE RIDGE PLATE, VALLEY <br />PLATE, EDGE STRIP, ETC., AS REQUIRED. <br />10. STEEL ROOF DECK SHALL BE WELDED AT ENDS AND ALL INTERMEDIATE <br />SUPPORTING MEMBERS WITH 5/8" DIAMETER PUDDLE WELDS OR <br />ELONGATED WELDS OF EQUAL STRENGTH SPACED PER SPECIFICATIONS <br />IN THE BOTTOM OF THE RIB ACROSS THE WIDTH OF THE DECK UNIT. <br />11. CUT OUT METAL DECK WHERE BOLT PROJECTIONS INTERFERE WITH <br />METAL DECK. <br />12. DIRECTION OF METAL DECK SHOWN THUS ON PLAN. <br />SHOP DRAWINGS: <br />1. NO STRUCTURAL DRAWINGS SHALL BE REPRODUCED FOR USE AS SHOP <br />DRAWINGS. <br />2. ALL DIMENSIONAL COORDINATION SHALL BE DONE BY THE CONTRACTOR <br />AND/OR HIS DETAILER. <br />3. DETAILER SHALL CHECK ALL ARCHITECTURAL AND MECHANICAL <br />DRAWINGS FOR ALL ATTACHMENTS, CLIPS, OPENINGS, OR DUCT WORK <br />AFFECTING STRUCTURAL MEMBERS. ALL ITEMS SHALL BE SHOWN ON <br />SHOP DRAWINGS. <br />4. ALL SHOP DRAWINGS SHALL BE SUBMITTED ON TRANSPARENCIES FOR <br />DIRECT REPRODUCTION WITH THREE PRINTS ONLY. DISTRIBUTION AS PER <br />ARCHITECT INSTRUCTIONS. <br />5. PROVIDE SUFFICIENT SPACE ON SHOP DRAWINGS NEAR TITLE BOX <br />(ABOUT 40 SQUARE INCHES) FOR STAMPS AND ENGINEERS COMMENTS. <br />6. THE SHOP DRAWINGS SHALL BEAR INITIALS OF DETAILER'S CHECKER <br />AND CONTRACTOR PRIOR TO SUBMISSION. <br />7. COMPLETED ERECTION PLANS SHALL BE SUBMITTED PRIOR TO OR IN <br />CONJUNCTION WITH DETAIL DRAWINGS. BUT IN NO CASE SHALL DETAIL <br />DRAWINGS BE SUBMITTED PRIOR TO ERECTION PLANS. <br />8. DETAILER SHALL SUBMIT AN INDEX OF THE DETAIL DRAWINGS WITH <br />EACH SHOP DRAWING SUBMITTAL. <br />9. SHOP DRAWINGS NOT COMPLYING WITH ALL THE ABOVE ITEMS SHALL <br />BE RETURNED FOR CORRECTIONS WITHOUT PROCESSING. <br />10. RESUBMITTED SHOP DRAWINGS SHALL HAVE THE FOLLOWING CHANGES <br />INCORPORATED: FIRST RESUBMISSION TO HAVE LETTER "A" ADDED TO <br />DRAWING <br />A. NUMBER AND ANY CHANGES MARKED ON THE DRAWING <br />MARKED 1 AT EACH ITEM CHANGED. ALL ITEMS TO BE NOTED IN <br />REVISION BOX. <br />B. SUBSEQUENT RESUBMISSION SHALL BEAR CHANGES "B" AND 2 <br />AND 3 ETC. AS IN 11 A. <br />11. CONTRACTOR SHALL HAVE SHOP DRAWINGS WHICH HAVE BEEN <br />SATISFACTORILY REVIEWED BY THE ARCHITECT AND/OR ENGINEER AND <br />CONFIRMED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY <br />WORK. <br />12. DETAILER SHALL USE THE SAME COLUMN NUMBERS IN HIS DETAILS AS <br />THOSE SHOWN ON CONTRACT DRAWINGS. <br />13. SHOP DRAWINGS FOR ALL STRUCTURAL ELEMENTS SHOULD BE <br />SUBMITTED TO MCE WITH A MINIMUM TIME TO BE REVIEWED OF 10 <br />WORKING DAYS, IN CASE OF A LARGE SUBMITTAL OR MORE THAN ONE <br />SUBMITTAL FOR THE SAME PROJECT. AN ADDITIONAL WORKING DAY IS <br />REQUIRED FOR EVERY 5 DRAWINGS/SHEETS OVER 30 <br />UGHTGAGE METAL FRAMING: <br />1. ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH <br />AMERICAN IRON AND STEEL INSTITUTE, "SPECIFICATION FOR THE DESIGN <br />OF COLD FORMED STRUCTURAL MEMBERS", 1996 EDITION. PROVIDE SIGN <br />AND SEALED CALCULATIONS AND DRAWINGS FOR ALL LIGHT GAGE <br />STRUCTURAL ELEMENTS OF THE BUILDING, INCLUDING THE EXTERIOR <br />METAL STUDS (CURTAIN WALL), AND ALL EXTERIOR CEILINGS. <br />2. ALL STRUCTURAL STUDS AND JOISTS 22, 20, AND 18 GAUGES SHALL <br />BE FORMED FROM GALVANIZED STEEL PER ASTM A653, G60 COATING <br />MEETING THE REQUIREMENTS OF ASTM C955 WITH A YIELD STRENGTH <br />OF 33,000 PSI. <br />3. ALL STRUCTURAL STUDS AND JOISTS 16, 14, AND 12 GAUGES SHALL <br />BE FORMED FROM GALVANIZED STEEL PER ASTM A653, G60 COATING <br />MEETING ASTM C955, WITH YIELD STRENGTH OF 50,000 PSI. <br />4. ALL STRUCTURAL TRACK AND BRIDGING SHALL BE FORMED FROM <br />GALVANIZED STEEL PER ASTM A653, G60 COATING MEETING THE <br />REQUIREMENTS OF ASTM C595, WITH YIELD STRENGTH OF 33,000 PSI. <br />5. WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE <br />MANUFACTURER'S STANDARD STEEL RUNNERS (TRACKS), BLOCKING, <br />LINTELS, CLIP ANGELS, SHOES, REINFORCEMENTS, FASTENERS, AND <br />ACCESSORIES AS RECOMMENDED BY MANUFACTURER FOR APPLICATIONS <br />INDICATED, AS NEEDED TO PROVIDE A COMPLETE METAL FRAMING <br />SYSTEM. <br />6. PROVIDE GALVANIZED FINISH TO METAL FRAMING COMPONENTS <br />COMPLYING WITH ASTM A653 FOR MINIMUM G 60 COATING. ATTACH <br />SIMILAR COMPONENTS BY WELDING. ATTACH DISSIMILAR COMPONENTS <br />BY WELDING, BOLTING OR SCREW FASTENERS, AS STANDARD WITH <br />MANUFACTURER. ALL WELDING SHALL BE PERFORMED BY WELDERS <br />CERTIFIED AND EXPERIENCED IN LIGHT GAGE STRUCTURAL STEEL <br />FRAMING WORK. <br />7. INSTALL METAL FRAMING SYSTEMS IN ACCORDANCE WITH <br />MANUFACTURER'S PRINTED OR WRITTEN INSTRUCTIONS AND <br />RECOMMENDATIONS, UNLESS OTHERWISE INDICATED. <br />8. INSTALL CONTINUOUS TRACKS SIZED TO MATCH STUDS. <br />9. SET STUDS PLUMB, EXCEPT AS NEEDED FOR DIAGONAL BRACING OR <br />REQUIRED FOR NON -PLUMB WALLS OR WARPED SURFACED AND <br />SIMILAR REQUIREMENTS. <br />10. WHERE STUD SYSTEM ABUTS STRUCTURAL COLUMN OR WALLS, <br />INCLUDING MASONRY WALL, ANCHOR ENDS OF STIFFENERS TO <br />SUPPORTING STRUCTURE. <br />11. SECURE STUDS TO TOP AND BOTTOM RUNNER TRACKS BY EITHER <br />WELDING OR SCREW FASTENERS AT BOTH INSIDE AND OUTSIDE <br />FLANGES. <br />WOOD FRAMING NOTES: <br />1. ALL WOOD FRAMING SHALL BE IN COMPLIANCE WITH THE LATEST NDS <br />EDITION FOR WOOD CONSTRUCTION. DIMENSIONED LUMBER SHALL BE <br />DRESSED S4S, AND SHALL BEAR THE GRADE STAMP OF THE <br />MANUFACTURER'S ASSOCIATION. <br />2. ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WRAP. <br />3. ALL FRAMING LUMBER SHALL BE SOUTHERN YELLOW PINE #2 OR <br />BETTER. <br />4. INTERIOR NON -LOAD BEARING WALLS SHALL BE UTILITY GRADE OR <br />BETTER. <br />5. MINIMUM OF 3-PLY STUD COLUMNS TO BE INSTALLED AT BEAM OR <br />GIRDER TRUSS BEARING LOCATIONS UNLESS NOTED OTHERWISE. <br />6. INSTALL BLOCKING IN ALL WALL STUDS OVER 8'-0" AT MID -HEIGHT, <br />AND SHEATHING JOINT. BRACE GABLE END AT 4'-0" O.C. AS SHOWN <br />IN THE DRAWINGS. <br />7. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE <br />PRESSURE TREATED OR OF NATURAL DURABLE WOOD. <br />8. PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH AN <br />APPROVED TREATMENT IN ACCORDANCE WITH F.S. 11-W-571 AND <br />BARE THE AMERICAN WOOD PRESERVES INSTITUTE EQUALITY MARK <br />LP-2. <br />9. SHEATHING SHALL BE APA EXTERIOR GRADE RATED, AND INSTALLED <br />WITH PLY -CLIPS AT 24" O.C. SEE NAILING SCHEDULE FOR SHEATHING <br />CONNECTION. <br />10. FLOOR SHEATHING SHALL BE A MINIMUM OF 5/8" TONGUE AND <br />GROOVE TYPE SUPPORTED AT 24" O.C. MAX, UNLESS NOTED <br />OTHERWISE IN PLAN. <br />11. ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE <br />OF TIMBER CONSTRUCTION REQUIREMENTS. ALL NAILS EXPOSED TO THE <br />EXTERIOR SHALL BE GALVANIZED. <br />12. ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED BY <br />SIMPSON STRONG TIE OR APPROVED EQUAL. SUBMIT CUT SHEETS FOR <br />ALL CONNECTION HARDWARE TO ENGINEER FOR APPROVAL. ALL NAIL <br />HOLES SHALL BE FILLED OR AS REQUIRED BY THE MANUFACTURER TO <br />ACHIEVE LOAD CAPACITY. <br />13. BRACING: TEMPORARY BRACING OF THE ROOF SYSTEM SHALL BE <br />INSTALLED PER HIB-91 RECOMMENDATIONS AND SHALL BE UTILIZED AS <br />THE PERMANENT BRACING FOR THE ROOF SYSTEM, UNLESS NOTED <br />OTHERWISE. <br />14. ALL WOOD FRAMING SHALL BE IN COMPLIANCE WITH THE LATEST NDS <br />EDITION FOR WOOD CONSTRUCTION. <br />PRE-ENGINEERED WOOD PRODUCTS: <br />1. ALL PRE-ENGINEERED WOOD PRODUCTS SHALL BE VERIFIED BY TRUSS <br />MANUFACTURER. TRUSS MANUFACTURER SHALL HAVE THE AUTHORITY <br />TO MAKE SUBSTITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS <br />DUE TO AVAILABILITY OR ECONOMICS. CHANGES SPECIFIED BY THE <br />TRUSS MANUFACTURER SHALL CONTROL CHANGES MADE AFTER TRUSS <br />ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD, MUST BE <br />APPROVED BY THE ENGINEER OF RECORD. <br />2. FRAMING PLAN IS DIAGRAMMATIC IN NATURE AND IS PROVIDED FOR <br />ILLUSTRATION PURPOSES ONLY. TRUSS MANUFACTURER TO PROVIDE <br />SEPARATE LAYOUT AND TRUSS COMPONENT DESIGN SIGNED AND <br />SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER. <br />3. ALL PRE-ENGINEERED WOOD PRODUCTS ARE THE RESPONSIBILITY OF <br />THE TRUSS MANUFACTURER. THE TRUSS ENGINEER IS A DELEGATED <br />ENGINEER FOR THIS PROJECT, AND AS SUCH, IS RESPONSIBLE FOR THE <br />VALIDITY OF THE COMPONENTS PROVIDED. FRAMING LAYOUTS SHOWN <br />MAY BE CHANGED BY THE TRUSS MANUFACTURER. THE DELEGATE <br />ENGINEER IS RESPONSIBLE FOR PROVIDING A FINAL SEALED SET OF <br />ALL CALCULATIONS AND LAYOUTS FOR THIS PROJECT TO THE ENGINEER <br />OF RECORD FOR REVIEW PRIOR TO MANUFACTURE OF SAID <br />COMPONENTS. ENGINEER OF RECORD HAS NOT REVIEWED THE <br />PRE-ENGINEERED TRUSS MANUFACTURER'S COMPONENTS AT THIS TIME <br />AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER SUCH <br />INFORMATION HAS BEEN PROVIDED FOR REVIEW. CONTRACTOR, AS <br />PROJECT COORDINATOR, SHALL BE RESPONSIBLE FOR INSURING <br />INFORMATION REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER <br />OF RECORD IN A TIMELY MANNER WHEN AVAILABLE. <br />4. ALL PRE-ENGINEERED TRUSSES TO BE DESIGNED USING THE MOST <br />RECENT TPI CRITERIA. TRUSSES TO BE HANDLED AND INSTALLED USING <br />MOST RECENT HIB RECOMMENDATIONS. TEMPORARY AND PERMANENT <br />BRACING SHALL BE PER MOST RECENT HIB RECOMMENDATIONS UNLESS <br />NOTED OTHERWISE, OR MORE STRINGENT CODE REQUIREMENTS APPLY. <br />TRUSS ENGINEER IS RESPONSIBLE FOR INDICATING ALL TRUSS TO <br />TRUSS CONNECTORS, ALL COMPONENTS TO BE DESIGNED FOR BOTH <br />GRAVITY AND UPLIFT LOAD CASES, INCLUDING BEAM COMPONENTS. <br />5. UPON REVIEW, ENGINEER OF RECORD WILL PROVIDE A REVIEW LETTER <br />INDICATING ANY CHANGE IN STRAPPING OR SUPPORT BASED ON THAT <br />REVIEW. CONSTRUCTION COMMENCING PRIOR TO ENGINEER'S REVIEW IS <br />SUBJECT TO MODIFICATION BASED ON REVIEW LETTER. <br />ARMANDO A. CASTELLON, P.E. <br />FL. LI C. No. 43453 <br />i <br />i <br />0 <br />z <br />9 <br />0 <br />�O <br />LO <br />LO O <br />.� <br />LO <br />> <br />L ' �� <br />._ <br />0? C? <br />00 <br />O <br />O <br />rn <br />s <br />� <br />c <br />.E <br />c <br />v <br />CL <br />N 0000 <br />CV <br />c M <br />O <br />U <br />� <br />'. 0 <br />a� O <br />} <br />c q__ <br />0 <br />O <br />-0 t\ -0 <br />C_�n <br />0 <br />c <br />W v <br />L 0 <br />a <br />LO O <br />U <br />Z <br />o <br />C� <br />N O <br />Z � <br />�` <br />Jgo W <br />� o <br />NnN N <br />W W <br />Z <br />oV d <br />� 00 o Z <br />I- 0 <br />U)ZC� <br />V) <br />w"'Q� o <br />QOZ <br />�owo a <br />�UW <br />vFroc <br />N[�M v N <br />CL C14 ado <br />w <br />� �ao() w <br />Qc copyright <br />revisions: <br />0 <br />0 <br />FAI <br />drawn: <br />checked: <br />date: <br />prof. no: <br />CN <br />�t <br />LO <br />CIO <br />C" ) <br />C) 0 <br />N <br />O O <br />N <br />m s <br />'O >` <br />O s <br />'0 Q <br />�O N <br />sc/d m <br />rd <br />1-15-08 <br />P07-15B <br />S1,01 <br />P:\2000 Prolects\2002 R K Collaborative\2002-010 Sonnys Prototyr - ' Zephyrhilis\Sdwg\S1.01.dwg, 2008-02-271:38:40 PM, Noel <br />Signature Date <br />