Laserfiche WebLink
r-------------------------------------i <br />I I I I I I <br />I I I <br />s <br />------------ <br />I I <br />I I <br />I I <br />I ! <br />I I <br />I I <br />I I <br />12 NEW HUB DRAIN - SEE PLUMBING. <br />13 2xo WOOD FRAMED WALL. PROVIDE DBL. STUD AT DOOR JAMBS. <br />STAGGER STUDS TO ACHIEVE WALL THICKNESS. <br />14 LOW WALL/P.O.S. STATION - SEE DETAIL E/Alc <br />15 42" HIGH LOW WALL- COVER WITH FRP - SEE DETAIL A/Alc (SIM.) <br />r <br />i RELOCATED EXHAUST HOOD - SEE MECHANICAL DRAWINGS <br />2 LOW WALL - SEE DETAIL A/Alc <br />3 PROVIDE BLOCKING AS NECESSARY FOR WALL MOUNTED TELEVISION. <br />4 NOT USED <br />5 PASS-THRU OPENING - HEAD AT I'-011 AFF. - FINISHED SILL AT 42" A.F.F. <br />o MATCH ADJACENT WINDOW OPENING SIZE <br />0 MASONRY INFILL a FLOOR - COORDINATE WITH SMOKER <br />8 NEW FLOOR DRAIN - SEE PLUMBING. <br />�r9) NEW DRAIN AT FLOOR LEVEL. RE -TILE AREA AS REQUIRED <br />/1/Al - I11itse'1 ® AGC AT C!>+��IIIAi^5r1 Lf ICI t IIIITI 1 ­l A1k1 T11 C <br />• j� -J'•'\. �-� P •L•J� ill <br />I. THIS PLAN IS FOR DIMENSIONAL PURPOSES ONLY. <br />2. 8" BLOCK WALLS AND o" STUD WALLS ARE DIMENSIONED TO FACE <br />OF WALL. <br />3. GENERAL CONTRACTOR TO NOTIFY ARCHITECT AFTER LAYOUT 15 <br />COMPLETE AND WALL TRACK IS IN PLACE PRIOR TO FRAMING ANY <br />WALLS. <br />4. GENERAL CONTRACTOR TO VERIFY AND COORDINATE ALL <br />PLUMBING AND ELECTRICAL ROUGH -INS REQUIREMENTS AND <br />LOCATIONS WITH EQUIPMENT SUPPLIER. <br />5. SEE PLUMBING AND ELECTRICAL DRAWINGS FOR MORE <br />INFORMATION. <br />20 GA. STEEL CHANNEL <br />FASTEN TO STRUCTURE <br />ABOVE <br />3 5/8" 25 GA. _ z <br />GALV. STEEL <br />BLOCKING AS PER FBC III <br />IN CEILING - SEE SHEET IDI. <br />PLYWOOD SHEATHING. <br />VENEER - SEE SHEET IDI. <br />5/8" PLYWOOD SHEATHING. <br />FRP VENEER - SEE SHEET IDI. <br />3 5/811 GALV. STEEL STUDS AT 16" <br />O.C, 20 GA.STUDS AT WALL <br />MOUNTED EQUIPMENT <br />5/6" DUROCK <br />25 GA. GALV. STEEL CHANNEL <br />FASTEN TO SLAB AT 24" O.G. <br />FINISH BASE MATERIAL - <br />SEE SHEET IDI. <br />FLOOR MATERIAL - SEE SHEET <br />EXISTING CONC. SLAB <br />TYPICAL SUBSTRATES FOR INTERIOR WALLS SHALL BE AS <br />FOLLOWS: <br />KITCHEN AND STORAGE AREAS: <br />0'-0" TO V-0" - 5/6" DUROCK, CEMENT BOARD, <br />V-011 AND ABOVE - 5/8" PLYWOOD. <br />SERVICE AREA AND DRIVE THRU: <br />5/811 MIN. PLYWOOD. <br />5/S" DUROCK CEMENT BOARD (WHERE TILE IS USED). <br />SALES AND SEATING AREAS: <br />5/8" GYPSUM BOARD - PLYWOOD AT CYPRESS SIDING <br />11 <br />CABINET IN NON RATED WALL <br />MODEL NO. 102IFi2 AS MANUFACTURED BY J.L. <br />INDUSTRIES. <br />TOP OF F.E. _ <br />a 5' -0" A.F.F. <br />MAX <br />FIRE <br />EXTINGUISHER <br />SEE SPECS. <br />OF CABINET <br />• A&-JW,_'- <br />GYPSUM <br />WALLBOARD <br />PER WALL TYPE <br />4" METAL STUDS <br />AT to" O.C. <br />