I <br />I 1 <br />1— ---- 11 1-- 1----1 1 1 I 1 1 ! II I 1_ -' 11,1 I <br />TERMITE PREVENTI❑N NOTES: <br />COMPLY WITH FBC 2020 7TH ED. SECTI❑N R318 <br />1, A PERMANENT SIGN WITH IDENTIFIES TREATMENT PR❑VIDER <br />AND NEED FOR RE-INSP AND TREATMENT RENEWAL SHALL BE <br />PR❑VIDED, THE SIGN SHALL BE POSTED NEAR THE WATER HEATER <br />ELECTRICAL PANEL FBC 104.26 <br />2, TO ENABLE TERMITE INSPECTI❑N, THE DISTANCE, BETWEEN WALL <br />C❑VERING AND EARTH GRADE SHALL BE 6 INCHES MINIMUM, <br />EXCEPTI❑N: C❑RRISI❑N REISITANT METALS, CEMENTATI❑US FINISHES <br />APPLIED DIRECTLY TO F❑UNDATI❑N. <br />3, INITIAL TERMITE TREATMENT SHALL BE COMPLETED AFTER ALL <br />EXCAVATI❑N AND BACK FILL IS FINISHED, <br />4, S❑ILD DISTURBED AFTER THE INITIAL TREATENT SHALL BE <br />RE -TREATED, INCLUDING SPACES BOXED OR FORMED, <br />5, BOXED AREAS IN CONCRETE FLOORS AND FOR SUBSEQUENT <br />INSTALLATI❑N OF TRAPS, ETC, SHALL BE MADE IN PERMANENT <br />METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF A SIZE <br />& DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF S❑IL <br />AFTER THE TREATMENT, <br />6, MINIMUM 6 MIL P❑LYFILM MUST BE INSTALLED TO PROTECT <br />AGAINST RAINFALL DILUTI❑N, RETREATMENT IS REQUIRED IF <br />RAINFALL OCCURS BEFORE P❑LYFILM PLACEMENT, <br />7, CONCRETE ❑VERP❑UR AND M❑RT❑R ALONG THE F❑UNDATI❑N <br />PERIMETER MUST BE REMOVED BEFORE EXYERI❑R S❑IL TREATMENT. <br />8, ALL BUILDINGS ARE REQUIRED TO HAVE PRE-C❑NSTRUCTI❑N <br />TREATMENT, <br />9, NO WOOD, VEGETATI❑N STUMP, CARDBOARD, TRASH, ETC, SHALL <br />BE BURIED WITHIN 15 FEET OF ANY BUILDING OR PROPOSED <br />BUILDING, <br />10, AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST <br />BE REMOVED FROM WITHIN ONE FOOT OF THE BUILDING, THIS <br />CELLULOSE CONTAINING TMATE�2IAL TRAP BOXES, FORMS, OTHER <br />11. A CERTIFICATE OF C❑MPLIANCE MUST BE PR❑VIDED TO THE <br />BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY <br />BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE <br />CERTIFICATE OF C❑MPLIANCE SHALL STATE THE BUILDING HAS <br />RECEIVED A COMPLETE TREATMENT FOR THE PREVENTI❑N OF <br />SUBTERRANEAN TERMITES AND THAT THE TREATMENT IS IN <br />ACCORDANCE WITH THE RULES AND LAW OF THE FLORIDA DEPT, <br />OF AGRICULTURE AND CONSUMER SERVICE. <br />EXISTING CONC. FILLED TIE BEAM <br />MISSING ANCHOR BOLTS @ BEARING WALL <br />EXTERI❑R BEARING WALL: <br />EXTERI❑R BEARING WALL: IN ADDITI❑N TO THE GENERAL <br />PLACEMENT REQUIREMENTS: USE 5/8 DIAMETER X 6" <br />EMBEDMENT BOLTS SPACED A MAXIMUM OF 24" D.C. <br />INTERI❑R BEARING WALL: <br />IN ADDITI❑N TO THE GENERAL PLACEMENT REQUIREMENTS: USE <br />5/8 DIAMETER X 6" EMBEDMENT BOLTS SPACED A <br />MAXIMUM OF 24" ❑.C„ IF RESISTING UPLIFT LOADS <br />MISSING DOWELS: <br />IN THE EVENT STEEL HAS BEEN INADVERTENTLY ❑MITTED <br />FROM DOWN POUR L❑CATI❑NS, DRILL 5" INT❑ CONCRETE <br />(N❑ CLOSER THAT 3 3/4" FROM EDGES AND 5" FROM ENDS <br />OF CAP WALLS), REMOVE DUST PER MFG'S REC❑MMENDATI❑NS <br />AND USE 2 PART EPDXY TO ANCHOR VERTICAL REINF❑RCEMENT <br />IN PLACE, USE EITHER HILTI C-100 OR SIMPS❑N EP❑XY-TIE, <br />REINFORCING STEEL: <br />REINF❑RCING STEEL SHALL BE ASTM A615 / A615M-12 MIN, GRADE 40, f'y = 40 K51 <br />LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25', #4 BAR 20', #3 BAR 20", <br />ALL DIMENSI❑NS PERTAINING TO THE L❑CATI❑N OF REINF❑RCING ARE TO THE <br />CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSI❑N IS SHOWN TO THE <br />FACE OF THE CONCRETE. <br />REINF❑RCING DETAIL DIMENSI❑NS ARE OUT TO OUT OF BARS, <br />REINF❑RCING MECHANICAL COUPLERS ARE TO DEVELOP 135 OF THE REQUIRED <br />YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF <br />RECORD. <br />DESIGN COVER REQUIREMENTS : <br />C-I-P CONCRETE FORMED AGAINST EARTH :3" <br />C-I-P CONCRETE EXPOSED TO EXTERI❑R : 2" <br />C-I-P CONCRETE NOT EXPOSED : i;j! <br />GROUT FILLED MASONRY 1 �41 <br />WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-14 <br />DETAIL REINF❑RCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) <br />ACI 530-16 (MASONRY STRUCTURES) <br />CONCRETE TYPE <br />DESIGN (f) <br />MODULES OF <br />DESIGN (E <br />C4-P CONCRETE (NORMAL WEIGHT) <br />2,500 Psi <br />2,850 KBI <br />C-I-P GROUT <br />3,000 Psi <br />3,122 Kai <br />CONCRETE SHALL C❑NSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP <br />BETWEEN 6' AND 7' AT TIME OF PLACEMENT, SEE SPECIFICATI❑NS FOR ADDITI❑NAL <br />CRITERIA, <br />GROUT SHALL C❑NSIST OF PEA ROCK (3/8' MAXIMUM AGGREGATE) CONCRETE MIX <br />WITH SLUMP BETWEEN 8' AND 10' AT TIME OF PLACEMENT. SEE SPECIFICATI❑NS FOR <br />ADDITI❑NAL CRITERIA, <br />C❑NSTRUCTI❑N J❑INTS WILL BE PERMITTED <br />METHOD OF CONCRETE F❑RMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN <br />ACCORDANCE WITH THE SPECIFICATI❑NS AS STATED, <br />EARTH SUPPORTED SLABS (EXCLUDING EXTERI❑R WALKWAYS & DRIVEWAYS) : <br />3 1/2' MIN. THICKNESS W/ MIN, REINF❑RCEMENT OF 6,0 x 6,0 W/ 1A x 1A WWF @ <br />MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I,L,❑, WWF @ <br />CONTRACTORS DISCRETI❑N, <br />CONCRETE MASONRY : <br />FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN, <br />LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE II <br />N❑N-M❑ISTURE CONTROLLED, <br />ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL <br />STEM WALLS, <br />THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI <br />MINIMUM, <br />METHOD OF CONCRETE MASONRY PLACEMENT AND C❑NSTRUCTI❑N SHALL BE <br />CONDUCTED IN ACCORDANCE WITH THE SPECIFICATI❑NS AS STATED. <br />MORTAR SHALL BE ASTM C270 TYPE 'S' FOR ALL MASONRY C❑NSTRUCTI❑N, <br />DOWEL INT❑ EXISTING <br />TOP TIE BEAM MIN, <br />G" SET IN EPDXY GR❑L. <br />CORNER CELL @ EXISTING <br />MASONRY WALL IS FILLEE <br />CELL W/(1)#5 VERT, <br />S❑IL: <br />MINIMUM S❑IL BEARING PRESSURE CAPACITY OF 2000 PSF, <br />F❑UNDATI❑NS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF <br />ALL S❑IL IS TO BE CLEAN & P❑IS❑NED FOR TERMITES PER FBC 7th ed, (2020), RESIDENTIAL SECTI❑N <br />R318, <br />NEW TO EXISTING <br />CELL SULID W/ C❑NC, <br />C❑NT, VERT, <br />C❑NT, #5 @ TOP TIE BEAM <br />SET IN C❑NC, LAP SPLICES <br />MIN 25" <br />16" LONG) #5 REBAR - DOWEL <br />8" INT❑ EXISTING AND NEW <br />WALLS - SET IN EPDXY GROUT <br />(2) #5's @ NEW F❑❑TER TO BE DOWELED <br />INT❑ EXISTING F❑❑TING MIN 8" - SET <br />IN EPDXY GROUT <br />MASONRY WALL CONNECTION <br />NOT TO SCALE <br />(1)#5 RER❑D IN GROUTED CELL <br />LOCATED PER PLAN <br />25" DOWEL LAP MINIMUM <br />4" CONCRETE (3000PSI) WITH #10 <br />6X6 MESH ON 6 MIL POLY <br />W ` = VAPOR BARRIER OVER CLEAN <br />COMPACTED P❑IS❑N TREATED <br />Q S❑IL. VAPOR BARRIER <br />> MATERIAL TO BE LAPPED <br />6"WITH SEAMS TAPED <br />FIBERMESH CAN BE SUBSTITUED <br />20"W X 12"H STEMWALL F❑❑TINGS WITH 2 EACH <br />#5 (5/8") RODS CONTINUOUS ON CHAIRS -TYPICAL <br />BOTTOM OF FOOTER SHALL BE 12" FROM GRADE <br />STEMWALL <br />FOOTING DETAIL <br />#5 VERTICAL WALL REINS❑RCING <br />ACI 90 STANDARDA IN GROUTED CELL <br />HOOK -EMBED 6' -BOND BEAM W/(1) #5 REBAR <br />= a <br />H Z.i <br />w <br />_ FILLED CELL <br />N <br />o .. <br />/LL <br />z - <br />o - <br />Q <br />> <br />W <br />w ¢ #5 DOWEL ACI STANDARD HOOK <br />J d <br />EMBED 10 MIN LAP <br />w Z 25" MIN W/ VERT, & H❑RIZ. REINF❑RCING <br />w <br />N <br />CONCRETE F❑❑TING <br />REINF❑RCING REBAR <br />' (SEE F❑UNDATI❑N PLAN) <br />5' MIN LAP <br />MASONRY WALL <br />FILLED CELL DETAIL <br />TING <br />#5 DOWEL H❑RIZ, REBAR <br />z BEAM REINF❑RCING <br />L IN CORNER <br />Q 1 //-WALLLRE NFORCING H <br />CORNER DETAIL - FOOTING AND <br />FOUNDATION WALL REINFORCEMENT <br />EN <br />53g06 <br />\`#5 CORNER REBAR <br />GR❑UTED CELL <br />N❑TE1 ALL LAPS SHALL BE 25' MINIMUM <br />CORNER DETAIL - BOND BEAM <br />AND WALL REINFORCEMENT <br />NEW SLAB TIED TO EXISTING SLAB WITH <br />#5 REBAR IMBEDDED 6' INT❑ ❑RIGINAL SLAB <br />AND 12' INT❑ NEW SLAB 4' ❑C MAX <br />NEW ADDITI❑N WALLS TIED TO EXISTING WALLS <br />WITH #5 REBAR IMBEDDED 8' INT❑ ❑RIGINAL WALL <br />AND 12' INT❑ NEW BLOCK WALL (EVERY OTHER COURSE) <br />NOTE: <br />INDICATES 1-#5 REBAR IN FILLED CELL FROM <br />F❑❑TING TO LINTEL, LOCATED AT EACH SIDE <br />OF ALL WIND❑WS AND DOOR ❑PENINGS <br />6' ❑,C, MAXIMUM SPACING. SEE DETAIL FOR L❑CATI❑NS <br />"'OUNDATION PLAAA <br />_p <br />u <br />I hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W, Smith, P,E, #53608 <br />