V <br />--1 11 1 1 p1' <br />i 11 if,, ll __ <br />STRUCTURAL LUMBER <br />INTERI❑R LOAD BEARING WALLS SPF #2 <br />ALL EXTERIOR FRAMING SPF #2 <br />ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER <br />ALL HEADER, BEAMS, COLUMNS ETC, TO BE SYP #2 OR BETTER <br />ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL <br />SHEATHING 15/32' EXP 1 OR 7/16' STRUCTURAL 1, U.N.O. <br />ALL PLYWOOD USED FOR INTERIOR APPLICATI❑NS SUCH AS SUB FLO❑RING AND <br />SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.D. <br />IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR <br />GREATER SECTION PROPERTIES. <br />ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERI❑R APPLICATION. WOOD IN <br />,CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE <br />MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD, <br />DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE 'DESIGN <br />SPECIFICATI❑N FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES' BY THE <br />ANSI/TPI 1-2007 BCSI <br />UNTREATED W❑❑t SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE, SEAT PLATES <br />SHALL BE PR❑VIDED AT BEARING L❑CATI❑NS WITHOUT WOODEN TOP PLATES, <br />ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8' STUCCO FINISH PER <br />ASTM C, 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8' OVER METAL LATH. FIRST <br />2 LAYERS 3/8' THICK EACH. 3RD LAYER 1/8' THICK <br />INSTALLATI❑N OF EXTERI❑R LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 <br />PER FLORIDA CODE R703,7 <br />FASTENERS AND TIE DOWNS 1 <br />FASTENERS AND TIE DOWNS SHALL C❑NSIST OF BUT ARE NOT LIMITED TO 1 <br />SHAPES, ANGLES, CHANNELS 1 ASTM A36/36M 05 F = 36 Ksi <br />ROUND METAL PIPE I ASTM A53, GRADE B Fy = 35y Ks! <br />SQUARE METAL TUBING I ASTM A500, GRADE B Fy = 46Ksi <br />HIGH STRENGTH BOLTS I ASTM A325 <br />MACHINE BOLTS 1 GALVANIZED ASTM A307 <br />SHEET METAL ACCESSORIES SHALL CONFORM TO I Fy = 33KsiWITH G90 <br />GALVANIZED C❑ATING IN ACCORDANCE WITH ASTM A525-87, <br />NAILS SHALL C❑NSIST OF : COMMON WIRE NAILS WITH MINIMUM DIAMETER AS <br />FOLLOWS : 8d = 0.131', 10d = 0.148', 12d = 0,148', 16d = 0.162. <br />ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERI❑R <br />APPLICATION ARE TO RECEIVE AN ANTI-C❑RROSIVE C❑ATING BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />ALL FASTENERS AND TIE DOWNS ARE TO PR❑VIDE THE UPLIFT CAPACITY CALLED <br />FOR IN THE PLANS ARE A MINIMUM, <br />ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS <br />STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND <br />SPECIFICATI❑NS, <br />CONCRETE EMBEDDED 'J' BOLTS USED FOR UPLIFT ARE TO BE WET SET PRI❑R TO <br />INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS, U,N,O, ALTERNATES TO -J' BOLTS ARE NOTED ON PLANS. <br />CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORCING PRRIOR TO OR WHILE PLACING GROUT, <br />NOTE: <br />GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE, FIELD <br />FASTENING SHOULD BE TYPE 'W' 114' DRYWALL SCREWS AT 12' ❑,C, FOR CEILINGS AND 1 <br />DRYWALL SCREWS AT 12' O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBA❑RD SHALL <br />OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS <br />(EDGES IN VERTICAL APPLICATI❑N) SHALL BE 6' O.C. AT EACH SUPPORT, MINIMUM SCREW / <br />NAIL DISTANCE FROM EDGE SHALL BE �-, THIS SHALL APPLY T❑ B❑TH CEILING AND WALL <br />INSTALLATION, DRYWALL SHIMS SHALLE USED ONLY WHERE NECESSARY, OPENINGS <br />CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED <br />ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITH❑UT ADDITI❑NAL TAPING <br />OR CAULKING, DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING, <br />NOTE: <br />ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM <br />AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. <br />EXTERIOR COVERING <br />R703,7 EXTERI❑R PLASTER <br />INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C926, ASTM C1063 AND THE <br />PR❑VISIONS OF THE CODE, <br />R703,7.1 LATH <br />LATH AND LATH ATTACHMENTS SHALL BE OF CORRISI❑N-RESISTANT MATERIALS. EXPANDED METAL OR WOVEN <br />WIRE LATH SHALL BE ATTACHED WITH 1-1/2-INCH-LONG (38mm), 11 GAGE NAILS HAVING A 7/16-INCH (11.1 mm) <br />HEAD, OR 7/8-INCH LONG (22.2 mm), 16 GAGE STAPLES, SPACED NOT MORE THAN 6 INCHES (152 mm), OR <br />AS ❑THERWISE APPROVED <br />R703,7.2 PLASTER <br />PLASTERING WITH P❑RTLAND CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHERE APPLIED OVER <br />METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHERE APPLIED OVER MASONRY, <br />CONCRETE, PRESSURE -PRESERVATIVE TREATED WOOD, OR DECAY -RESISTANT WOOD AS SPECIFIED IN SECTI❑N <br />R317.1 OR GYPSUM BACKING, IF THE PLASTER SURFACE IS COMPLETELY COVERED BY VENEER ❑R OTHER <br />FACING MATERIAL OR IS COMPLETELY C❑NCELAED, PLASTER APPLICATION NEED BE ONLY TWO COATS , PR❑VIDED <br />THE TOTAL THICKNESS IS AS SET FORTH IN TABLE R702,1(1) <br />R703,7,2.1 WEEP SCREEDS <br />A MINIMUM 0,019-INCH (0,5 mm) (N❑. 26 GALVANIZED SHEET GAGE), C❑RRISI❑N-RESISTANT WEEP SCREED OR <br />PLASTIC WEEP SCREED, WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES (89 mm) SHALL BE <br />PR❑VIDED AT OR BELOW THE F❑UNDATI❑N PLATE LINE ON EXTERI❑R STUD WALLS IN ACCORDANCE WITH ASTM <br />C926, THE WEEP SCREED SHALL BE PLACED NOT LESS THAN 4 INCHES (102 mm) ABOVE THE EARTH OR 2 <br />INCHES (51 mm) ABOVE PAVED AREAS AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN <br />TO THE EXTERIOR OF THE BUILDING. THE WEATHER -RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE, <br />THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED, <br />R703.73 WATER-RESISTANT BARRIERS <br />WATER-RESISTANT BARRIERS SHALL BE INSTALLED AS REQUIRED IN SEDCTION R703.2 AND, WHERE APPLIED OVER <br />WOOD -BASED SHEATHING, SHALL INCLUDE A WATER RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE <br />AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER, THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />(INSTALLED IN ACCORDANCE WITH SECTION R703,4) INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS <br />DIRECTLY BETWEEN THE LAYERS, <br />EXCEPTI❑N1 WHERE THE WATER-RESISTANT BARRIER THAT IS APPLIED OVER WOOD -BASED SHEATHING HAS A <br />WATER RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPERATED <br />FROM THE STUCCO BY AN INTERVENING, SUBSTANTIALLY N❑NWATER-ABS❑RBING LAYER OR DESIGNED DRAINAGE <br />SPACE, <br />R703.7.4 APPLICATION <br />EACH COAT SHALL BE KEPT IN A MOIST CONDITI❑N FOR AT LEAST 48 HOURS PRIOR TO APPLICATION OF THE <br />NEXT COAT. <br />EXCEPTI❑N1 APPLICATIONS INSTALLED IN ACCORDANCE WITH ASTM C926 INCLUDING THE REFERENCE IN ASTM <br />C926 SECTI❑N 8 TO SECTION X1.4.2 OF THE APPENDIX. <br />R703,7,5 CURING <br />THE FINISH COAT FOR TWO -COAT CEMENT PLASTER NOT BE APPLIED SOONER THAN SEVEN DAYS AFTER <br />APPLICATION OF THE FIRST COAT, FOR THREE -COAT CEMENT PLASTER, THE SECOND COAT SHALL NOT BE <br />APPLIED SOONER THAN 48 HOURS AFTER APPLICATI❑N OF THE FIRST C❑AT, THE FINISH COAT FOR THREE COAT <br />CEMENT PLASTER SHALL NOT BE APPLIED SOONER THAN SEVEN DAYS AFTER APPLICATION OF THE SECOND COAT, <br />EXCEPTION: APPLICATI❑N INSTALLED IN ACCORDANCE WITH ASTM C926 INCLUDING THE REFERENCE IN ASTM <br />C926 SECTI❑N 8 TO SECTI❑N X1.4.2 OF THE APPENDIX. <br />TABLE R302,6 DWELLING -GARAGE SEPARATI❑N <br />SEPARATION <br />MATERIAL <br />FROM THE RESIDENCE AND ATTICS <br />EQUIVALENT APPLIED TOGTHEUGARAGE SIDE <br />FROM HABITABLE ROOMS ABOVE THE GARAGE <br />NNRDE❑R EQBIVA�EN�NCH TYPE X GYPSUM <br />STRUCTURE(S) SUPPORTING FL❑❑R/CEILING ASSEMBLIES <br />NOT LESS THAN 1/2-INCH GYPSUM BOARD <br />USED FOR SEPERATI❑N REQUIRED BY THIS SECTION <br />OR EQUIVALENT <br />GARAGES LOCATED LESS THAN 3 FEET FROM A DWELLING <br />NOT LESS THAN 1/2-INCH GYPSUM BOARD OR <br />UNIT ON SAME LOT <br />EQUIVALE'!T APPLIED TO THE INTERIOR SIDE <br />OF EXTERIOR WALLS THAT ARE WITHIN THIS AREA <br />FLASHING SHALL COMPLY WITH R903.2 <br />UNDERLAYMENT SHALL COMPLY WITH SECTION R90511 <br />VALLEYS SHALL COMPLY WITH R905.2,8.2 <br />DRIP EDGE SHALL COMPLY WITH R905.2.8.2 <br />PER FLORIDA BUILDING CODE 2020, 7th EDITI❑N <br />PROPER ATTACHMENT OF SOFFITS PANELS TO RESIST <br />WIND LOADS, IN ACCORDANCE WITH R704.2.1/R702.2.2 <br />PER FLORIDA BUILDING CODE 2020, 7th EDITI❑N <br />ASPHALT ROOF <br />SHINGLES ARE CLASSIFIED IN ACCORDANCE WITH <br />IN ACCORDANCEAWITH OR <br />R90ASTM <br />2 6.1D FBC 7thSS F <br />EDITION (2020) - RESIDENTIAL, <br />❑PTI❑NAL1 <br />LEAD BOOT FLASHING W/ INTEGRAL <br />FLANGE SET IN PLASTIC ROOF CEMENT <br />VENT STACK SEE PLUMBING FOR <br />SIZE AND L❑CATI❑NS <br />FLEXIBLE BOOT FLASHING WITH <br />INTEGRAL FLANGE SET IN <br />PLASTIC ROOF CEMENT <br />INSTALL FLANGE OVER <br />SHINGLE AT BASE ----,- <br />INSTALL SHINGLES OVER FLANGE <br />AT HEAD <br />SHINGLE R❑❑FING OVER 15# FELT <br />OVER 7/ 16' OR 15/32' CDX <br />PLYWOOD <br />N❑TES1 <br />1, INSTALL IN STRICT ACCORDANCE WITH <br />MANUFACTURERS WRITTEN INSTRUCTI❑NS <br />2, APPLY R❑❑FING CEMENT OR <br />SELF -ADHERING FLASHING OVER FLANGE AT <br />HEAD ONLY <br />ROOF PENETRATION <br />FLASHING DETAIL <br />MyKIM01u M:�1i i= <br />UNDERLAPP <br />VENT HOD <br />2020 FBC RESIDENTIAL SECTI❑N R703,4 FLASHING <br />APPROVED C❑RRISI❑N RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHI❑N IN A MANNER TO PREVENT ENTRY <br />OF WATER INT❑ THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURE FRAMING COMPONENTS, <br />SELF ADHERED MENBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATI❑N <br />PRODUCTS SHALL BE SEALED AT THE JUNCTI❑N WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA <br />800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSI❑N AND C❑NTRACTION, ASTM <br />C 1281 AAMA 812 OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT, FLUID APPLIED <br />MEMBRANES USED AS FLASHING IN EXTERI❑R WALLS SHALL COMPLY WITH AAMA 714, THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERI❑R WALL FINISH, APPROVED C❑RR❑SI❑N RESISTANT FLASHINGS SHALL BE INSTALLED AT <br />THE F❑LL❑WING LOCATI❑NS. <br />1, EXTERI❑R WINDOW AND DOOR OPENINGS, FLASHING AT EXTERIOR WINDOW AND DOOR ❑PENINGS SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER C❑MPLYING WITH SECTI❑N <br />703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA <br />712, FLASHING AT EXTERI❑R WIND❑W AND DOOR ❑PENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />MORE OF THE F❑LL❑WING. <br />1.1 THE FENESTRATI❑N MANUFACTURERS INSTALLATI❑N AND FLASHING INSTRUCTIONS OR THE APPLICATI❑NS <br />NOT ADDRESSED IN THE FENESTRATI❑N MANUFACTURERS INSTRUCTI❑NS IN ACCORDANCE WITH THE <br />FLASHING MANUFACTURERS INSTRUCTIONS, WHERE FLASHING INSTRUCTI❑NS OR DETAILS ARE NOT <br />PR❑VIDED PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR ❑PENINGS <br />PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER FOR SUBSEQUENT DRAINAGE <br />❑PENINGS USING PAN FLASHING SHALL BE INC❑RPORATE FLASHING OR PR❑TECTION AT THE HEAD AND SIDES <br />MORE OF THE FOLL❑WING. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PR❑FESSI❑NAL <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS <br />1.4 IN ACCORDANCE WITH FMA/AMMA 100 FMA/AAMA 200 FMA/WDMA 250 FMA/AMMA/WDMA 300 <br />OR FMA/AAMA/WDMA 400 <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY C❑NSTRUCTI❑N WITH FRAME OR STUCCO WALLS WITH <br />PR❑JECTING LIPS ON BOTH SIDES UNDER STUCCO C❑PINGS <br />3. UNDER AND AT THE ENDS OF MASONRY WOOD OR METAL C❑PINGS AND SILLS <br />4. CONTINU❑USLY ABOVE ALL PROJECTING WOOD TRIM <br />5, WHERE EXTERI❑R PORCHES, DECKS AND STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME C❑NSTRUCTION <br />6. AT WALL AND ROOF INTERSECTIONS <br />7. AT BUILT-IN GUTTERS <br />.,,,,-1— , — . - -T T"-•'ISTING WALLS <br />IGINAL WALL <br />THIRD CURSE) <br />EXISTING I TKITE-I <br />EXTERIOR WINDO W FILL IN <br />FLf <br />50 <br />► a1i <br />_uLI. I\ <br />ROOF VENTS <br />(OFF RIDGE) DETAIL <br />-';IS I iNG LINTEL <br />STANDARD <br />VALLEY FLASHING <br />ROOF UNDERLAYMENT <br />UNDERLAPMENT TO LAP OVER <br />VALLEY METAL A MINIMUM OF 2' <br />:UT TOP CORNER OF UNDERLAYMENT TO <br />NSURE PROPER DIVERSION OF WATER INT❑ <br />FHE METAL VALLEY <br />VALLEY FLASHING (EXTEND ENTIRE <br />WIDTH OF VALLEY METAL BEYOND <br />ROOF EDGE <br />VALLEY UNDERLA YMENT do <br />FLASHING DETAIL <br />HIP & RIDGE CUT <br />FROM METRIC <br />THREE TAB SHINGLES <br />PREVAILING 5I ---\ <br />WIND DIRECTION <br />`-5 5/8" FAST <br />DIS ANCJ <br />STANDARD <br />MANSARD OR <br />NORMAL WIND AREAS HIGH WIND AREAS <br />0 0 <br />5" EXPOSURE <br />NEW ADDITI❑N WALLS TIED TO EXISTING WALLS <br />WITH #5 REBAR IMBEDDED 8' INT❑ ❑RIGINAL WALL <br />AND 12' INT❑ NEW BLOCK WALL (EVERY THIRD COURSE) <br />EXTERIOR DOOR FILL IN <br />I hereloy certif y that I have reviewed this plan and found it to loe in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W. Smith, P.E. #53608 <br />���`Q•.:NGENSe •• ��i <br />SHINGLE NAILING NOTES: <br />ALL NAILS MUST PENETRATE AT LEAST 3/4" INTO <br />THE WOOD ROOF DECK. <br />NAIL SHINGLES WITH 11 OR 12 GAUGE GALVANIZED NAILS <br />WITH 3/8" DIAMETER HEADS - 6 REQUIRED (AS SHOWN <br />IN "HIGH WIND AREAS") <br />ROOF —TO —WALL FLASHING NOTES: <br />4" X 5" ANGLE FLASHING - 26 GAUGE GALVANIZED METAL, <br />RUBBER VALLEY FLASHING OR 12" WIDE - 26 GAUGE <br />GALVANIZED METAL WITH SHINGLES OVER THE TOP. <br />MATERIAL SPECIFICATIONS: <br />UNDERLAYMENT SHALL CONFORM TO ASTM D226, TYPE I <br />OR ASTM 4869, TYPE I. <br />ENING FLASHING FOR ASPHALT SHINGLES SHALL COMPLY WITH <br />FBC R905.2.8 <br />ASPHALT SHINGLES SHALL COMPLY TO ASTM D225 OR <br />ASTM D3462. <br />VALLEY LINER <br />• <br />UNDERLAYMENT <br />ROOF SHINGLE 8c FLASHING INSTALLATION SPEC'S <br />NOT TO SCALE <br />REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS <br />(RE: FBRC R308,4) <br />IR308,3 HUMAN PS DESI NE D I❑N DSSIINDIVIDUAL <br />T I N R30$L4 GSHAALLD AREAS <br />AS ASTHI EC TEST REQUIREMENTS❑ OF INHAZARDOUS <br />A16D❑CFR,LPART101201 CRITERIA THOSE <br />CATEG❑RY I ❑R CATEGORY II AS INDICATED IN TABLE R308.3,1 <br />EXCEEPITIIOENSSi ED E IN N TH FIRE ESIgT <br />2, L ❑UVEREDWWIND❑WS AND AL�USIES SHL D❑��PANYD WTTHE SECTION R3pg zNT LOCATIONS SALL COMPANY WITH ANSI Z97,1-14 <br />R308.4 HAZARDOUS LOCATIONS, <br />THE ❑NSIDERED gpE I HqZ <br />THE 1F[&L&p NGIN HSWINGING D❑❑RS EXCEPT CJALSUSIESRD❑US L❑CATIONS FOR THE PURPOSE OF GLAZINGi <br />2, GLAZING IN FIXED AND SLIDING PANELS ❑F SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR <br />ASEMBLIES <br />3. GLAZING IN STORM DOORS <br />4. GLAZING IN ALL UNFRAMED SWINGING DOORS <br />5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLP❑❑LS, SAUNAS, STEAM ROOMS, BATHROOMS, AND SHOWERS <br />GLAZING IN ANY PART OF A BUILDING WALL ENCLOSURE THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE <br />GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE <br />6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS <br />WITHIN 24-INCH ARC OF THE DOOR IN A CLOSED P❑SITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES <br />ABOVE THE FLOOR OR WALKING SURFACE <br />7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE L❑CATIONS DESCRIBED IN ITEMS 5 AND 6 <br />ABOVE, THAT MEETS ALL OF THE F❑LL❑WING C❑NDITI❑NS, <br />71 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. <br />7.2 BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR <br />7.3 TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR <br />7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES H❑RTIZ❑NTALLY OF THE GLAZING <br />8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE, INCLUDED ARE STRUCTUAL <br />BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. <br />9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR OR OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE <br />BOTTOM EGDE OF THE GLAZING IS LESS THANK 50 INCHES ABOVE A WALKING SURFACE AND WITHIN 60 INCHES <br />HORTIZ❑NALLY OF THE WATER'S EDGE, THIS SHALL BE APPLY TO SINGLE GLAZING AND ALL PANELS IN MULTIPLE GLAZING, <br />10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES H❑RTIZ❑NALLY OF A WALKING <br />SURFACE WHEN THE EXP❑SSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE <br />ADJACENT WALKING SURFACE, <br />11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES H❑RTIZ❑NALLY OF THE BOTTOM TREAD OF A STAIRWAY IN <br />ANY DIRECTI❑N WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE NOSE OF THE TREAD. <br />EXCEPTI❑N, THE F❑LLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS <br />1. ❑PENINGS IN DOORS THROUGH WHICH A 3-INCH SPHERE IS UNABLE TO PASS, <br />2. DECORATIVE GLASS IN ITEMS 1.6 OR 7, <br />3. GLAZING IN SECTION R308,4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE <br />DOOR AND THE GLAZING. <br />4. GLAZING IN SECTION R308.4.2. ITEM 3, IN WALLS PERPENDICULAR R❑ THE PLANE OF THE DOOR IN A CLOSED POSITI❑N OR <br />WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN <br />THESE APPLICATIONS SHALL COMPANY WITH SECTI❑N R308.4, ITEM 2. <br />5. GLAZING IN SECTION R308,43, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDES) OF THE GLAZSING 36 <br />INCHES ± 2 INCHES ABOVE THE FLOOR. THE BAR DHALL BE CAPABLE OF WITHSTANDING A HORIZ❑NTAL LOAD OF 50 POUNDS <br />PER LINEAR FOOT WITH❑UT C❑NTACTING THE GLASS AND BE A MINIMUM OF 1-112 INCHES <br />6. OUTBOARD PANES IN INSULATING GLASS UNITS AND ❑THE MULTIPLE GLAZED PANELS IN SECTION R308,4, ITEM 7, WHEN <br />THE BOTTOM EDGE OF THE GLASS IS 25 FEET OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER H❑RTIZ❑NAL <br />(WITHIN 45 DEGREES OF H❑RTIZ❑NTAL SURFACE ADJACENT TO THE GLASS EXTERIOR. <br />7. LOUVERED WIND❑WS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTI❑N R308,2 <br />8. MIRR❑RS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINU❑US BACKING SUPPORT, <br />9. SAFETY GLAZING IN SECTI❑N R308,4 IS NOT REQUIRED WHERE, <br />9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, <br />COMPLYING WITH THE PREVISI❑NS OF SECTI❑N 1014 OF THE FLORIDA BUILDING CODE, BUILDING AND <br />9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES FROM THE RAILING. <br />