II F'1 i I - - 1 1 ',11; 1 111, liffilil i i jy111l' I ll---- <br />FYI <br />SMOKE DETECTORS: <br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE <br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN <br />7TH EDITION, 2020 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017). <br />CARBON MONOXIDE DETECTORS: <br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01/08 AND HAVING A <br />FOSSIL—FUEL—BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL <br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION, <br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL <br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP. <br />ELECTRICAL: <br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER <br />2020 7TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART VIII — ELECTRICAL) <br />NEC 2017: 210.12 — ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS. <br />NEC 2017: 210.8 — INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS, <br />PORCH AND LANAI. <br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN. <br />NOTES: <br />UNLESS ❑THERWISE NOTED <br />1. <br />ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE: 12' AFF (GENERAL) <br />KITCHEN <br />44' AFF <br />BATHROOM <br />39' AFF <br />LAUNDRY ROOM <br />36' AFF <br />EXTERI❑R WATERPROOF <br />12' AFF <br />GARAGE GENERAL PURPOSE <br />42' AFF <br />RANGE <br />2' AFF <br />2, <br />ALL TRIM PLATES & DEVICES <br />TO BE GANGED, WHERE <br />P❑SSIBLE <br />3. <br />ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF, <br />4. <br />ELECTRICAL PLAN IS INTENDED FOR <br />BID PURPOSES ONLY. ALL <br />WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATI❑NAL ELECTRIC CODE, LATEST <br />EDITI❑N, BY LICENSED ELECTRICAL <br />CONTRACTOR WHO SHALL BE <br />RESP❑NSIBLE <br />FOR THE INSTALLATI❑N & SIZING OF <br />ALL ELECTRICAL, WIRING & <br />ACCESS❑RIES. <br />5. <br />GROUND WIRE FORM REBAR TO <br />ELECTRICAL PANEL PER <br />N.E.C. 2017 <br />SYMBOL DESCRIPTION <br />SWITCH <br />$3 3 WAY SWITCH <br />$4 4 WAY SWITCH <br />$R RHEOSTAT SWITCH <br />110 V RECEPTICLE(1/2 SWITCHED) <br />110 V RECEPTICLE <br />FI 110 V RECEPTICLE - GROUND FAULT <br />8AFI 110 V RECEPTICLE - ARC FAULT <br />8wP 110 V RECEPTICLE - WATERPROOF OUTLET <br />6 220 V RECEPTICLE <br />F81 DUPLEX OUTLET IN FLOOR <br />8 110 V QUAD <br />8wP 110 V QUAD WATERPROOF OUTLET <br />® RECESSED INCANDESCENT <br />{� LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />+ EXHAUST FAN/LIGHT C❑MBINATI❑N <br />FL❑URESCENT FIXTURE <br />Q� FLOOD LAMPS <br />VANTITY LIGHT <br />co PUSH BUTTON FOR GARAGE OPENER <br />SO]) SMOKE /FIRE DETECTOR/ALARM <br />C&M SMOKE/CARBON MON❑XIDE DETECTOR - COMBO <br />© CARBON M❑N❑XIDE DETECTOR <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />FAN W/L <br />a I DISC❑NNECT <br />MECHANICAL: <br />CONDENSATE <br />PIPING, TAIL <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />LINES SHALL <br />EXTENSIONS, <br />DISCHARGE AT LEAST <br />OR SPLASH BLOCKS. <br />12" AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND <br />2020 FMC, 7TH EDITION -EQUIPMENT DISCONNECT MUST BE WITHIN SIGHT OF THE EQUIPMENT, <br />BATHROOMS MUST BE VENTILATED MECHANICALLY AND EXHAUSTED TO BUILDING EXTERIOR. <br />AIR HANDLER FLOAT SWITCHES ARE REQUIRED TO SHUT DOWN THE UNIT OR OTHER APPROVED DEVICE TO ALERT THE HOME <br />OWNER THAT THE CONDENSATE DRAIN LINE IS NOT WORKING PROPERLY. <br />THERE MUST BE A NOTICE POSTED ON THE ELECTRICAL PANEL ALERTING THE HOME OWNER THAT THE AIR HANDLER IS <br />LOCATED IN THE ATTIC (WHEN APPLICABLE). <br />N OTE: <br />MECHANICAL CONTRACTOR TO DETERMINE UNIT SIZE PER ENERGY CALCULATIONS <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINISTRATI❑N CODE, <br />MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES, THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS, <br />D.W. SMITH,M. S.,P.E. #53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE—DADE CITY, FL❑RIDA 33525 <br />PHONEI ( CELL) 813-469-2289 E-MA I LI dwsf l pe@earth link, net <br />STUTZMAN ERIC <br />6810 WIRE ROAD <br />ZEPHYRHILLS, FLORIDA <br />ELECTRICAL <br />SHEET OF <br />SCALE <br />DO NOT SCALE <br />17 AUG 2021 <br />6OF6 <br />JOB NO, <br />RICK COLLHARDT - DRAFTSMAN DES I GN/DRAWN CHECKED 2021-0921 <br />PHIINFI (CFI I) A 13-781-3651 F-MA TI I rnn l l hnrdtPtmmnnbnv. rr, rnm R. G 0 LLHA R DT D. W. S. P E <br />
The URL can be used to link to this page
Your browser does not support the video tag.