ROOF TOP PACKAGE UNIT SCHEDULE <br />UNIT NO. <br />(MARK) <br />TOTAL <br />SUPPLY <br />(CFM) <br />OUTSIDE <br />AIR <br />(CFM) <br />EXT./TOT. <br />S.P. <br />(IN. W.G.) <br />TOTAL <br />CAPACITY <br />(MBH) <br />SENSIBLE <br />CAPACITY <br />(MBH) <br />HEATING <br />CAPACITY <br />(MBH) <br />ELEC. HEAT <br />(KW/STEPS) <br />E.A.T.(°F) <br />L.A.T.(°F) <br />INDOOR FAN <br />MCA/MFS <br />ELECTRICAL <br />DATA <br />(V/PH/HZ) <br />EER <br />DESIGN <br />MANUF. <br />MODEL <br />NOTES <br />D.B./W.B. <br />D.B,/W.B. <br />DRIVE <br />HP <br />RPM <br />RTU-1 <br />4,500 <br />1,200 <br />0.35/- <br />1 51 .0 <br />87.1 <br />92.2 <br />27.0/2 <br />80.8/70.0 <br />58.0/57.2 <br />BELT <br />3.0 <br />778 <br />108/1 1 0 <br />208/3/60 <br />9.8 <br />TRANE <br />TCD 1 51 D3 <br />1 ,2,4 <br />RTU-2 <br />2,400 <br />360 <br />0.40/- <br />73.8 <br />39.2 <br />46.1 <br />13.5/1 <br />78.1 /66.5 <br />58.0/56.6 <br />BELT <br />1.0 <br />909 <br />53.1 /60 <br />208/3/60 <br />1 1 .2 <br />TRANE <br />TSC072E3 <br />1 ,2,4 <br />RTU-3 <br />2,900 <br />820 <br />0.55/- <br />93.2 <br />52.1 <br />46.1 <br />13.5/1 <br />81 .7/70.8 <br />58.0/57.1 <br />BELT <br />2.0 <br />856 <br />54.8/60 <br />208/3/60 <br />1 1 .2 <br />TRANE <br />TSC092E3 <br />1 ,2,3,4 <br />NOTES: <br />1. PROVIDE 7 DAY PROGRAMMABLE THERMOSTATS LOCATION <br />SHOWN ON PLAN. <br />2. PROVIDE 100% OUTSIDE AIR ECONOMIZER. <br />3. PROVIDE BAROMETRIC RELEIF DAMPER HOOD. <br />4. PROVIDE WITH MANUFACTURER'S ROOF CURB. <br />AIR BALANCE SCHEDULE <br />UNIT NO, <br />(MARK) <br />SUPPLY <br />CFM <br />RETURN <br />CFM <br />❑UTSIDE <br />CFM <br />EXH, <br />CFM <br />TRANSFER <br />CFM <br />RELIEF <br />CFM <br />EXFIL, <br />CFM <br />RTU-1 <br />4,500 <br />3,300 <br />1,200 <br />0 <br />1,000 <br />0 <br />200 <br />RTU-2 <br />2,400 <br />2,040 <br />360 <br />0 <br />300 <br />0 <br />60 <br />RTU-3 <br />2,900 <br />2,400 <br />820 <br />0 <br />500 <br />320 <br />0 <br />EF-1 <br />0 <br />0 <br />0 <br />2,100 <br />0 <br />0 <br />0 <br />EF-2 <br />0 <br />0 <br />0 <br />1,000 <br />0 <br />0 <br />0 <br />EF-3 <br />0 <br />0 <br />0 <br />300 <br />0 <br />0 <br />0 <br />SF-1 <br />0 <br />0 <br />1,600 <br />0 <br />0 <br />0 <br />0 <br />VENTILATION RATE TABLE <br />BASIS: ASHRAE STANDARD 62.1 -2004 <br />RTU-1 <br />DINNING ROOM: 1,804 SQ. FT. X 0.18 CFM/SQ. FT. = 324.7 CFM <br />116 PEOPLE X 7.5 CFM/PERSON = 870 CFM <br />TOTAL OUTSIDE AIR REQUIRED: 1,194.7 CFM <br />RTU-2 <br />DINNING ROOM: 560 SO. FT. X 0.18 CFM/SQ. FT. = 100.8 CFM <br />35 PEOPLE X 7.5 CFM/PERSON = 260 CFM <br />TOTAL OUTSIDE AIR REQUIRED: 360.8 CFM <br />RTU-3 <br />KITCHEN: 39 PEOPLE X 20 CFM/PERSON = 780 CFM <br />DINNING ROOM: 95 SO. FT. X 0.18 CFM/SQ. FT. = 17.1 CFM <br />3 PEOPLE X 7.5 CFM/PERSON = 22.5 CFM <br />TOTAL OUTSIDE AIR REQUIRED: 819.6 CFM <br />EXHAUST FAN SCHEDULE <br />UNIT NO. <br />(MARK) <br />CFM <br />EXT. S.P. <br />(IN H20) <br />MOTOR <br />RPM <br />MAX. <br />SONES <br />DRIVE <br />TYPE <br />DESIGN <br />MANUF. <br />MODEL <br />NOTES <br />V/PH/HZ <br />HP <br />EF-3 <br />1 3001 <br />0.25 <br />1 1 5/1 /60 <br />1 /1 2 <br />1,550 <br />7.2 <br />DIRECT <br />INLINE <br />GREENHECK <br />SQ-80-D <br />1,2 <br />1. PROVIDE WITH UNIT MOUNTED DISCONNECT AND GRAVITY BACKDRAFT DAMPER. <br />2. INTERLOCK FAN WITH RTU-1 . <br />AIR DISTRIBUTION DEVICE SCHEDULE <br />MARK <br />SERVICE <br />DESCRIPTION <br />MATERIAL <br />MANUF. <br />MODEL <br />NOTES <br />S-1 <br />SUPPLY <br />SQUARE CONE DIFFUSERS <br />ALUMINUM <br />EH PRICE <br />SCD <br />1 ,2,3 <br />R-1 <br />RETURN <br />LOUVERED FACE RETURN <br />ALUMINUM <br />EH PRICE <br />630 <br />1 ,2,3 <br />E-1 <br />EXHAUSTI <br />LOUVERED FACE EXHAUST <br />ALUMINUM <br />EH PRICE <br />630 <br />1 ,2,3 <br />1, PROVIDE OPPOSED BLADE VOLUME DAMPER. <br />2. STANDARD BAKED -ON WHITE ENAMEL FINISH. <br />3. PROVIDE 24X24 CEILING MODULE AS REQUIRED <br />1 <br />1 <br />1 <br />1 <br />1 <br />I <br />1 <br />1 <br />1 <br />DESIGN CONDITIONS <br />SUMMER <br />WINTER <br />DB('F) <br />WB(`F) <br />DB('F) <br />OUTDOOR <br />91.4 <br />77.5 <br />36.6 <br />INDOOR <br />75.0 <br />62.6 <br />68.0 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 1 <br />1 <br />i <br />1 <br />1 <br />1 <br />1 <br />KITCHEN HOOD SCHEDULE <br />EXHAUST <br />SUPPLY <br />DESCRIPTION <br />MARK <br />VOLUME <br />(CFM) <br />SP <br />(IN WC) <br />DUCT COLLAR <br />VELOCITY (FT/M) <br />FILTER FACE <br />VELOCITY (FT/M) <br />VOLUME <br />(CFM) <br />SP <br />(IN WC) <br />DUCT COLLAR <br />VELOCITY (FT/M) <br />LENGTH <br />WIDTH <br />H-1 <br />2,100 <br />0.50 <br />1,700 <br />175 <br />1,600 <br />0.1 <br />750 <br />10'-0" <br />7'-0" <br />FAN SCHEDULE <br />UNIT NO. <br />(MARK) <br />CFM <br />S.P. <br />(IN H20) <br />SF-1 <br />1,600 <br />0.40 <br />EF-1 <br />2,100 <br />1 0.90 <br />EF-2 <br />11,000 <br />1 0.40 <br />1 <br />i <br />NOTE: KITCHEN HOOD SCHEDULE IS PROVIDED <br />FOR REFERENCE ONLY. KITCHEN HOODS WILL 1 <br />BE PROVIDED BY THE OWNER. REFER TO HOOD 1 <br />MANUFACTURER'S DRAWINGS FOR COORDINATION. 1 <br />1 <br />1 <br />HVAC LEGEND: <br />GENERAL NOTES: <br />SUPPLY, RETURN, AND EXHAUST DUCT <br />1. INSTALLATION SHALL COMPLY WITH ALL LOCAL, STATE AND FLORIDA ENERGY CODES. <br />2. CONTRACTOR SHALL INSTALL ALL EQUIPMENT, PIPING AND DUCTWORK SUCH THAT <br />FLEXIBLE SUPPLY AND RETURN DUCT <br />MANUFACTURERS' RECOMMENDED CLEARANCES ARE MET FOR ALL ACCESS PANELS, COILS, MOTORS, <br />FANS, BELTS, FILTERS, AND AIR INTAKES. <br />SUPPLY GRILLE <br />3. PROVIDE ACCESS PANELS IN ALL NON -ACCESSIBLE CONSTRUCTIONS (INCLUDING CEILING, WALLS, <br />RETURN AND EXHAUST GRILLE <br />ETC.) SIZED AND LOCATED AS REQUIRED TO PROVIDE PROPER SERVICE ACCESS IN ACCORDANCE <br />WITH THE MANUFACTURERS RECOMMENDATION FOR ALL HVAC EQUIPMENT INCLUDING DAMPERS. <br />COLLAR TAKE -OFF WITH DAMPER <br />AIR DISTRIBUTION NOTES: <br />OPPOSED BLADE VOLUME DAMPER <br />1. DUCTWORK SHALL BE FABRICATED, INSTALLED AND INSULATED PER "SMACNA" STANDARDS <br />AND ALL LOCAL AND STATE CODES. <br />UNDERCUT DOOR 3/40 <br />2. DUCT SIZES ARE INSULATED SHEET METAL SIZES AND ARE "CLEAR" INSIDE DIMENSIONS. ALL DUCT <br />3/4" <br />SHALL BE EXTERNALLY INSULATED WITH 2.2" THICK KNAUF DUCTWRAP WITH R=6.0 VALUE. <br />TT <br />THERMOSTAT <br />3. ROUND RUNOUTS TO GRILLES (AND BACKS OF GRILLES) TO BE WRAPPED WITH 2.2" THICK KNAUF <br />DUCTWRAP WITH R=6.0 AND FSK JACKET (OR EQUAL). <br />SD <br />SMOKE DETECTOR <br />4. FLEXIBLE DUCTWORK TO BE ATCO RUBBER PRODUCTS (OR EQUAL) INSULATED FLEX DUCT WITH <br />R=6.0 VALUE. <br />X-1 <br />DIFFUSER TAG X = S-SUPPLY <br />CFM <br />X = R-RETURN <br />5. CONTRACTOR SHALL VERIFY CLEARANCE SPACE AVAILABLE, OFFSETS REQUIRED, STRUCTURAL <br />INK <br />NK = NECK SIZE X = E-EXHAUST <br />OPENINGS, AND WORK BY OTHER TRADES PRIOR TO FABRICATION OF DUCTWORK. COORDINATE <br />WITH ROOF TRUSSES/STRUCTURE. PRESSURE TEST ALL DUCTWORK FOR LEAKS. RETURN DUCT <br />X-# <br />EQUIPMENT TAG <br />SHALL BE TESTED UNDER NEGATIVE PRESSURE. <br />X = EF - EXHAUST FAN <br />X = H - KITCHEN HOOD <br />EQUIPMENT NOTES: <br />X = SF - SUPPLY FAN <br />X = RTU - PACKAGE UNIT <br />1. PROVIDE FULL SIZE INSULATED CONDENSATE DRAINS FROM ALL UNITS TO NEAREST OUTLET. <br />2. PROVIDE A TRAP ON ALL CONDENSATE DRAIN OUTLETS. SLOPE ALL CONDENSATE DRAIN PIPING <br />DETAIL NUMBER <br />1 /8" INCH PER FOOT. <br /># <br />3. CONTRACTOR SHALL INSTALL ALL EQUIPMENT, PIPING AND DUCTWORK SUCH THAT MANUFACTURERS' <br />RECOMMENDED CLEARANCES ARE MET FOR ALL ACCESS PANELS, COILS, MOTORS, FANS, BELTS, <br /># <br />FILTERS, AND AIR INTAKES. <br />SHEET NUMBER <br />WHERE SHOWN <br />4. ALL SMOKE DETECTION DEVICES SHALL BE INSTALLED PER LOCAL AND STATE CODES. <br />MECHANICAL PERMIT DOCUMENTS©2007 <br />AIRCO MECHANICAL, INCORPORATEDjl_� <br />DESIGN. <br />Certificate of Authorization No.: 27407 <br />BUILD. <br />N 0 <br />RC <br />THESE MECHANICAL DOCUMENTS, DESIGNS, NOTES, <br />DETAILS, CONCEPTS ARE THE <br />AIRCO <br />- <br />SOLUTION. <br />PROPERTY OFME <br />SOLE CHANICAL, INC. AND <br />M E C H A N I c A L_ - <br />SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR <br />OR HERFE MR°tPETCMC. <br />WRITTEN IOF`JASSON <br />6334 118TH AVENUE N. P: 727-547-9700 <br />CONSENTS. <br />M.M. <br />BY THE ENGINEER <br />RIGHTS ARE RESEREWITH <br />LARGO, FLORIDA 33773 F: 727-547-9754 <br />RECORD IN ACCORDANCEALL <br />U.S. COPIRIGHTOAND <br />PATUSEENT <br />VVM.AIRCO-MECHANICAL.COM <br />WILL BESPROSECUTEDITODTHEPRODUCTINULL EXTOENTND <br />OF <br />THE LAW. <br />N <br />'t <br />r <br />aj N <br />V <br />U <br />°° <br />C <br />0 co <br />CU coo <br />�w <br />a <br />� <br />U04 <br />JT <br />N <br />U <br />J <br />0 <br />00 <br />C <br />Lw <br />a <br />> <br />.. <br />o <br />2 <br />C; <br />co <br />C <br />s <br />N <br />0 <br />o�Q <br />_ <br />`C <br />a <br />J" <br />06LL <br />E <br />UL <br />a <br />0 <br />O <br />N <br />0 <br />0 <br />0 <br />0 <br />_ <br />c <br />Q <br />N <br />J <br />O� <br />O <br />J <br />o <br />_J <br />J <br />U <br />0 <br />M <br />0 <br />0 <br />0 <br />N <br />Q <br />N <br />It <br />M <br />CM <br />OLL <br />z <br />o <br />Q <br />N <br />mp <br />Q <br />0 <br />CO <br />0 <br />UJ <br />o <br />o <br />� <br />U <br />Z] <br />(� <br />00 <br />(� <br />J <br />U_ <br />J <br />W <br />N <br />Revisions: <br />W <br />J � <br />Z <br />Cl W <br />_ (D <br />W W <br />� J <br />Q Q <br />U_ <br />Z U) <br />Q W <br />=0 <br />W Z <br />2 <br />Project Number <br />163 <br />Date <br />11-16-07 <br />Sheet Number <br />M -4 <br />