! 1. A 1 11 I. H 1 1 1 1 11 L 11 - --- _ -1 R_ 1 1 1 !1 1 1- _ I I I ---I
<br />---- --- --
<br />301
<br />IRF
<br />VE
<br />PANEL
<br />A
<br />SQ.D TYPE,_Q❑__ NEMA,--- 1 _ MTD,__ SURF. SPACES,____42
<br />V❑LT�_1�Q/�Q$_ PH�__3 WIRES, BAR--__ YES
<br />AMPS__ 600_,_ MAIN_LUG____
<br />FEEDER WIRES,
<br />2 SETS 4 350 MCM THWN & 1 #1 THWN CU
<br />CIR
<br />4MP
<br />P
<br />LOAD
<br />VA
<br />WIRE
<br />I CIR
<br />MP
<br />PI
<br />LOAD
<br />VA
<br />I WIRE 2
<br />1
<br />20
<br />1
<br />LIGHTS
<br />.84
<br />3-#12, 1/2'C
<br />1 2
<br />20
<br />1
<br />EXIT/EMER, LIGHTS
<br />,3
<br />3-#12, 1/2-C
<br />3
<br />20
<br />1
<br />J-BOX FOR SIGN
<br />.18
<br />3-#12, 1/2'C
<br />4
<br />5
<br />20
<br />1
<br />RECEPT.
<br />,18
<br />3-#12, 1/2-C
<br />6
<br />7
<br />8
<br />9
<br />10
<br />11
<br />12
<br />13
<br />14
<br />15
<br />16
<br />17
<br />18
<br />19
<br />20
<br />21
<br />22
<br />23
<br />24
<br />25
<br />26
<br />27
<br />28
<br />29
<br />30
<br />31
<br />32
<br />33
<br />34
<br />35
<br />36
<br />37
<br />38
<br />39
<br />40
<br />41
<br />42
<br />TOTAL CONNECTED LOAD = 1,140/360 = 3,25 AMPS
<br />2
<br />HOUSE UNIT A
<br />HOUSE 0 0
<br />PANEL
<br />100/3 600/3 SERVICE
<br />DISCONNECT /C
<br />UNIT B SWITCH
<br />1,200 AMP
<br />4-43 THHN, 1#8 THHN 0120/240V
<br />EQ, GRD, IN 1' NIPPLE 1PH, 3W
<br />200/3
<br />UNIT C
<br />0
<br />1 ELECTRICAL PLAN
<br />E -1 SCALD 1/81 = 1'-0• a D
<br />HOUSE PANEL
<br />PANEL
<br />H
<br />SQ,D TYPE,_ Q❑__ NEMAI__ 1 _ MTD,__SURF,SPACES, .... 42
<br />VCLTT_j2Q4aQ$_ PH-__3 WIRES�___4GRN, BAR,___ YES
<br />AMPS,__100A,_ MAIN_LUG_--_
<br />FEEDER WIRES,
<br />4 #3 CU THWN & 1 #8 CU THWN
<br />CIR
<br />8IMP
<br />P
<br />LOAD
<br />VA
<br />WIRE
<br />CIR
<br />MP
<br />P
<br />LOAD
<br />VA
<br />WIRE
<br />1
<br />30
<br />2
<br />IRRIGATION PUMP
<br />1.5
<br />3-#10, 3/4'C
<br />2
<br />20
<br />1
<br />CANOPY LTS
<br />72
<br />3-#12, 1/2'C
<br />3
<br />4
<br />20
<br />1
<br />CANOPY LTS
<br />.96
<br />3-#12, 1/2'C
<br />5
<br />6
<br />7
<br />8
<br />9
<br />10
<br />1111
<br />12
<br />2 TOTAL CONNECTED LOAD = 3,180/360 = 9 AMPS
<br />PANEL
<br />B
<br />_SQ.D TYPEiQONEMAl__ 1 _ MTD,__ SURF, SPACES,____42
<br />V❑LT�_1�'Q['�Q$_ _3 WIRES__ 4GRN, BARI---- YES
<br />AMPS,__ 200MAIN_LUG____
<br />FEEDER WIRES,
<br />4 3/0 CU THWN & 1 #6 CU THWN
<br />CIR
<br />MP
<br />PI
<br />LOAD
<br />VA
<br />WIRE
<br />CIR
<br />4MP
<br />IP
<br />LOAD
<br />VA
<br />WIRE 2
<br />1
<br />120
<br />1
<br />LIGHTS
<br />42
<br />3-#12, 1/2'C
<br />2
<br />20
<br />1
<br />EXIT/EMER, LIGHTS
<br />.3
<br />3-#12, 1/2'C
<br />3
<br />120
<br />1
<br />J-BOX FOR SIGN
<br />.18
<br />3-#12, 1/2'C
<br />4
<br />5
<br />20
<br />1
<br />RECEPT,
<br />.18
<br />3-#12, 1/2'C
<br />6
<br />7
<br />B
<br />9
<br />10
<br />11
<br />12
<br />13
<br />14
<br />15
<br />16
<br />17
<br />18
<br />19
<br />20
<br />21
<br />22
<br />23
<br />24
<br />25
<br />26
<br />27
<br />28
<br />29
<br />30
<br />31
<br />32
<br />33
<br />34
<br />35
<br />36
<br />37
<br />38
<br />39
<br />40
<br />41
<br />42
<br />TOTAL CONNECTED LOAD = 1,080/360 = 3 AMPS
<br />2
<br />LOAD CALCULATION
<br />PANEL H = 3,180
<br />A = 1,140
<br />B = 1,080
<br />C = 1,080
<br />6,480/240 = 27 AMPS
<br />LIGHT FIXTURE SCHEDULE
<br />MARK
<br />TYPE
<br />FINISH
<br />LENS
<br />VOLT
<br />LAMP
<br />MANUF,
<br />CATALOG
<br />REMARKS
<br />A
<br />8' FLUOR
<br />SURF, STRIP
<br />WHITE
<br />N/A
<br />120V
<br />75W (96')
<br />SLIMLINE
<br />LITHONIA
<br />C 2 96
<br />BSURF,
<br />MOUNTED
<br />ROUND FIXTURE
<br />WHITE
<br />N/A
<br />120V
<br />1-22W
<br />LITH❑NIA
<br />AS SELECTED
<br />C
<br />EXIT LIGHT
<br />WHITE
<br />STENCIL
<br />120V
<br />N/A
<br />LITH❑NIA
<br />LQM S W 3 R EL N
<br />2-8W
<br />D
<br />BATTERY PACK
<br />WHITE
<br />N/A
<br />120V
<br />TUNGSTEN
<br />LITH❑NIA
<br />ELU2
<br />HALOGEN
<br />PANEL
<br />C
<br />SQ.D _ TYPEt__QONEMA,___1 _ MTD,__ SURF, SPACES,____42
<br />VOLT,_122/EQ$_ PH�3 WIRES,__ 4GRN, BAR! ---- YES
<br />AMPS,__200_,_ RAIN LUG _
<br />FEEDER WIRESi
<br />4 3/0 CU THWN & 1 #6 CU THWN
<br />CIR
<br />NMP
<br />IP
<br />LOAD
<br />VA
<br />WIRE
<br />CIR
<br />4MP
<br />P
<br />LOAD
<br />VA
<br />WIRE Z2
<br />1
<br />20
<br />11
<br />LIGHTS
<br />.42
<br />3-#12, 1/2'C
<br />2
<br />20
<br />1
<br />EXIT/EMER, LIGHTS
<br />,3
<br />3-#121 1/21C
<br />3
<br />20
<br />1
<br />J-BOX FOR SIGN
<br />,18
<br />3-#12, 1/2'C
<br />4
<br />5
<br />20
<br />1
<br />RECEPT,
<br />,18
<br />3-#12, 1/2'C
<br />6
<br />7
<br />8
<br />9
<br />10
<br />11
<br />12
<br />13
<br />14
<br />15
<br />16
<br />17
<br />18
<br />19
<br />20
<br />21
<br />22
<br />23
<br />24
<br />25
<br />26
<br />27
<br />28
<br />29
<br />30
<br />31
<br />32
<br />33
<br />34
<br />35
<br />36
<br />37
<br />38
<br />39
<br />40
<br />41
<br />42
<br />TOTAL CONNECTED LOAD = 1,080/360 = 3 AMPS
<br />2
<br />200/3
<br />4 SETS 3' PVC W/ 4
<br />350 MCM EACH
<br />LIGHTNING
<br />ARRESTOR
<br />#3/0 GRD, ELECTRODE
<br />CONDUCTOR
<br />WTR DRIVEN
<br />GRD GRD
<br />ELECTRICAL RISER DIAGRAM
<br />SCALES N.T.S.
<br />GENERAL ELECTRICAL NOTES
<br />1, ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REVISION OF
<br />THE N,E,C. AND LOCAL GOVERNING CODES,
<br />2, ALL MATERIALS WHERE APPLICABLE SHALL BE U,L, LABELED,
<br />3, CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP
<br />FOR (1) YEAR,
<br />4, CONTRACTOR SHALL VERIFY LOCATION AND ELECTRICAL REQUIREMENTS OF
<br />ALL EQUIPMENT FURNISHED BY OTHER TRADES PRI❑R TO INSTALLING
<br />WIRE AND CONDUIT,
<br />5. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, #121 S❑LID
<br />WITH SINGLE BRAID, #10 AND LARGER, STRANDED, WITH AT LEAST DOUBLE
<br />BRAIDi TYPE RHW, THHN, OR THHW FOR FEEDERS AND BRANCH CIRCUITS
<br />#12 AWG MINIMUM SIZE, ALL INSULATION TO BE TW OR THW,
<br />6, CONTRACTOR TO VERIFY ELECTRICAL REQUIRMENTS OF ALL EQUIPMENT
<br />BEFORE INSTALLING ANY R❑UGH-IN,
<br />LIGHTING PLAN LEGEND
<br />SYM,
<br />DESCRIPTION
<br />REMARKS
<br />8' FLUORESCENT LIGHT
<br />SEE FIXTURE SCHEDULE
<br />I---i
<br />F--i
<br />4' FLUORESCENT LIGHT
<br />SEE FIXTURE SCHEDULE
<br />CEILING MOUNTED FIXTURE
<br />SEE FIXTURE SCHEDULE
<br />WALL MOUNTED LIGHT
<br />SEE FIXTURE SCHEDULE
<br />EMERGENCY BATTERY UNIT WITH TWO
<br />ADJ HEADS
<br />SEE FIXTURE SCHEDULE
<br />®
<br />EXIT LIGHT
<br />SEE FIXTURE SCHEDULE
<br />SWITCH, SINGLE POLE
<br />L 48' AFF OR AS NOTED
<br />0
<br />PANELBOARD
<br />TOP 72' AFF
<br />IQ
<br />DUPLEX RECEPTACLE,125V,20A
<br />18' AFF
<br />W.P.
<br />INDICATES WEATHER PROOF
<br />GFI
<br />INDICATES GROUND FAULT INTERRUPTER
<br />Q
<br />JUNCTION BOX
<br />QJ
<br />DISCONNECT SWITCH
<br />AS NOTED
<br />U�
<br />8
<br />8
<br />�
<br />a
<br />c
<br />J
<br />M
<br />M
<br />M
<br />LL
<br />a
<br />>
<br />o
<br />VJ
<br />r
<br />L
<br />OQ
<br />N
<br />a
<br />J
<br />LL
<br />0
<br />U�
<br />N
<br />OILD
<br />C
<br />g
<br />co
<br />>
<br />U
<br />O
<br />Q
<br />U
<br />J
<br />G
<br />LL
<br />O
<br />JC
<br />O
<br />JJ
<br />LJL
<br />06
<br />g
<br />0
<br />n
<br />0
<br />N
<br />O
<br />J
<br />J
<br />ICT
<br />LO
<br />M
<br />Z
<br />LLJ
<br />U
<br />J
<br />>
<br />a_ji
<br />zpcn
<br />z
<br />a.In
<br />0 m
<br />J
<br />L)
<br />a.
<br />Q
<br />LU
<br />Z
<br />W
<br />N
<br />�N
<br />Revisions:
<br />8/28/07 - OWNER
<br />2 REQUESTED
<br />CHANGES
<br />9/24/07 - OWNER
<br />3 REQUESTED
<br />CHANGES
<br />(n
<br />W
<br />(I)
<br />J
<br />Q
<br />o
<br />Q
<br />Z
<br />W
<br />Zaky
<br />JQ°,
<br />q
<br />V
<br />�o{'
<br />m
<br />W
<br />< N
<br />1,
<br />U
<br />rn
<br />W
<br />Q
<br />W
<br />Project Number
<br />06082a
<br />Date
<br />03-19-07
<br />Sheet Number
<br />E-1
<br />
|