GENERAL NOTES & SPECIFICATIONS <br />EXIST, 1-HOUR SEPARATI❑N <br />(U.L. DESIGN U-465) <br />BETWEEN MERCANTILE <br />GROUP M OCCUPANCY & <br />ASSEMBLY GROUP A-2 <br />OCCUPANCY, AS REQUIRED <br />BY F,B.C, TABLE 508.3.3 — <br />EXIST. <br />VACANT <br />TENANT <br />SPACE <br />- <br />ij /� I <br />SECURE L_ __ _J L_ DATA I <br />— r 104 <br />DRUG -� <br />� TOILET ROOM <br />102 103 <br />00 <br />o J 1 <br />I il. <br />PHARMACY <br />r <br />i- � <br />I� u I <br />OFFICE <br />I., <br />,I I --- ----- -- -- ----- <br />1 <br />�f <br />I! � <br />I � <br />_CN-- --J- �-- - - --- - ---}. <br />---� W <br />II z <br />f Q <br />� II A ' <br />W I�I > <br />SALES <br />100 <br />.j <br />i <br />I <br />I 27 <br />5.4'(H) <br />_1 66' <br />I I <br />LIFE SAFETY FLOOR PLAN <br />SCALES 1/4' = F-0' <br />aD <br />20 <br />1 <br />20 <br />4'(H) <br />33' <br />FIRE BARRIER IDENTIFICATION (NFPA 101 SECTION 8.3.2.4) <br />1, EACH NEW FIREWALL, FIRE BARRIER OR ANY OTHER NEW WALL REQUIRED TO HAVE <br />PROTECTED OPENINGS SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING <br />ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES WITH THE WORDING, <br />'FIRE AND SMOKE BARRIER-PR❑TECT ALL OPENINGS.' <br />2, SUCH SIGNS OR STENCILING SHALL BE IN 4 INCH HIGH LETTERS, 1/2 INCH STROKE <br />AND NOT MORE THAN 15 FEET ON -CENTER, <br />FIRE BARRIER PENETRATIONS (NFPA 101 SECTION 8.3.5.1) <br />1. PENETRATIONS FOR CABLES, CABLE TRAYS, CONDUITS,, PIPES, TUBES, COMBUSTION <br />VENTS AND EXHAUST VENTS, WIRES, AND SIMILAR ITEMS TO ACCOMMODATE <br />ELECTRICAL, MECHANICAL, PLUMBING, AND C❑MMUNICATIONS SYSTEM THAT PASS <br />THROUGH A MEMBRANE OF A WALL, FLOOR, OR FLOOR / CEILING ASSEMBLY <br />CONSTRUCTED AS A FIRE BARRIER SHALL BE PROTECTED BY A FIRESTOP SYSTEM OR <br />DEVICE TESTED IN ACCORDANCE WITH ASTM E814 OR UL1479, <br />2. WHERE DEVICES ARE INDICATED IN A FIRE OR FIRE/SMOKE BARRIERS ON THE <br />DRAWINGS, THE MAXIMUM ALLOWABLE AREA OF INDIVIDUAL U.L. LISTED BACKBOXES <br />PERMITTED IN THE WALL IS 16 SQ. IN, WITH A MAXIMUM AGGREGATE OF 100 SQ, IN, <br />PER 100 SQ. FEET OF WALL AREA, <br />3. BACKBOXES ON OPPOSITE FACES OF SUCH BARRIERS SHALL BE OFFSET A MINIMUM <br />HORIZONTAL DISTANCE OF 24 INCHES. <br />4, WHEN PENETRATI❑NS EXCEED THE ALLOWABLE AREAS, THE DEVICES SHALL BE SET IN <br />A FURRED SPACE IN FRONT OF THE SMOKE OR FIRE/SMOKE BARRIER OR PROVIDED <br />WITH A FIVE -SIDED ENCLOSURE CONSTRUCTED OF LAYERS OF 5/8' THICK TYPE 'X' <br />GYPSUM WALLBOARD EQUAL IN NUMBER TO THAT REQUIRED FOR THE RATING OF THE <br />BARRIER, INSTALLED WITH APPROVED FASTENERS SCREWED TO STUDS AND HEADERS. <br />5. WHERE FIRE RATED ASSEMBLIES OCCUR IN PROXIMITY TO STEEL BEAMS OR JOISTS <br />WITH INADEQUATE DIMENSION TO INSTALL SCREWS, CONTRACTOR SHALL PROVIDE STUD <br />FRAMING AROUND THE BEAM OR JOIST IN ACCORDANCE WITH U.L, DESIGN N-501 WITH <br />LAYERS OF GYPSUM WALLBOARD EQUAL TO THAT REQUIRED BY THE RATING OF THE <br />BARRIER. <br />EXIT DOOR TACTILE SIGNAGE (LSC 101 CH 7.10.1.3) <br />1. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING AN EXIT SIGN. <br />2. TACTILE SIGNAGE SHALL READ AS FOLLOWS, EXIT, <br />3. TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1 AMERICAN NATIONAL STANDARD <br />FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES. <br />4. THESE REQUIREMENTS SHALL NOT APPLY TO EXISTING BUILDINGS, PR❑VIDED THAT THE <br />OCCUPANCY CLASSIFICATION DOES NOT CHANGE. <br />NOTICE FOR STRUCTURES WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION (FAC 69A-60.0081) <br />1. ANY COMMERCIAL, INDUSTRIAL, OR MULTIUNIT RESIDENTIAL STRUCTURE OF THREE <br />UNITS OR MORE, WHICH USES HORIZONTAL OR VERTICAL LIGHT -FRAME TRUSS -TYPE <br />CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH AN APPROVED SYMBOL. <br />TOWNHOUSES ARE NOT MULTIUNIT RESIDENTIAL STRUCTURES AND THEREFORE NOT <br />SUBJECT TO THIS RULE. EACH APPROVED SYMBOL SHALL INCLUDE WITHIN THE CENTER <br />CIRCLE ONE OF THE FOLLOWING DESIGNATIONS, <br />A. STRUCTURES WITH LIGHT -FRAME TRUSS ROOFS SHALL BE MARKED WITH THE <br />LETTER `R". <br />B. STRUCTURES WITH LIGHT -FRAME TRUSS FLOOR SYSTEMS SHALL BE MARKED WITH <br />THE LETTER `F". <br />C. STRUCTURES WITH LIGHT -FRAME TRUSS FLOOR AND ROOF SYSTEMS SHALL BE <br />MARKED WITH THE LETTERS `RF." <br />2, THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO THE LEFT OF THE <br />MAIN ENTRY DOOR AND, <br />A, BE PERMANENTLY ATTACHED TO THE FACE OF THE STRUCTURE ON A CONTRASTING <br />BACKGROUND, OR <br />B. BE MOUNTED ON A CONTRASTING BASE MATERIAL WHICH IS THEN PERMANENTLY <br />ATTACHED TO THE FACE OF THE STRUCTURE. <br />3. THE DISTANCE ABOVE THE GRADE, WALKING SURFACE OR THE FINISHED FLOOR TO THE <br />BOTTOM OF THE SYMBOL SHALL BE NOT LESS THAN 4 FEET (48 IN.), <br />4, THE DISTANCE ABOVE THE GRADE, WALKING SURFACE OR THE FINISHED FLOOR TO THE <br />TOP OF THE SYMBOL SHALL BE NOT MORE THAN 6 FEET (72 IN.). <br />5, IN SINGLE TENANT STRUCTURES WITH MULTIPLE MAIN ENTRY DOORS, SUCH AS BIG BOX <br />RETAIL STORES, DEPARTMENT STORES AND GROCERY STORES, THE AUTHORITY HAVING <br />JURISDICTION IS AUTHORIZED TO REQUIRE THAT OTHER MAIN ENTRY DOORS OF THE <br />STRUCTURE BE MARKED WITH AN APPROVED SYMBOL. <br />6. IN MULTIPLE TENANT STRUCTURES AND COVERED MALL STRUCTURES WITH MULTIPLE <br />MAIN ENTRY DOORS, THE AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO REQUIRE <br />THAT OTHER MAIN ENTRY DOORS OF THE STRUCTURE BE MARKED WITH AN APPROVED <br />SYMBOL, <br />7. IN MULTIPLE TENANT STRUCTURES AND COVERED MALLS WITH MULTIPLE MAIN ENTRY <br />DOORS, THE AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO REQUIRE THAT <br />OTHER MAIN ENTRY DOORS BE MARKED WITH AN APPROVED SYMBOL, IN SUCH <br />STRUCTURES, APPROVED SYMBOLS SHALL BE MARKED ON ONE SIDE OF THE STRUCTURE <br />ONLY AND SPACED NOT CLOSER THAN 100 FEET OR AT EACH END OF THE STRUCTURE <br />WHEN SUCH STRUCTURE IS LESS THAN 100 FEET IN LENGTH, <br />LIFE SAFETY CALCULATIONS <br />EXIT REQ'D. OCCUP, PROVIDED PROVIDED <br />OCCUPANCY AREA SO, FT./ OCCUPANT EXIT WIDTH/ LOAD EXIT CLEAR EXIT EXIT <br />CLASSIF. (SO. FT.) OCCUPANT LOAD COMPONENT PERSON WIDTH (IN,) WIDTH (IN,) CAPACITY <br />(IN.) <br />MERCANTILE 1,403 47 PPL <br />GROUP M GROSS 30 S.F. PER FBC HORIZ, 0.20 9.4 99 495 PPL <br />1004.1.2 <br />EXIT CAPACITY <br />128 = OCCUPANT LOAD <br />25,6'(H) = REQUIRED EGRESS WIDTH (V = VERTICAL, H = HORIZ❑NTAL) <br />33' = PROVIDED WIDTH <br />LIFE SAFETY LEGEND <br />4 <br />PRIMARY EXIT <br /><J <br />SECONDARY EXIT <br />© <br />PULL STATION <br />O <br />SMOKE DETECTOR <br />O <br />HEAT DETECTOR <br />HORN WITH STROBE <br />OJ STROBE ONLY <br />® <br />ILLUMINATED EXIT SIGN, SINGLE FACE, <br />�. <br />W/ DIRECTION ARROW <br />COMBO EXIT/EMERGENCY LIGHT <br />FACP <br />FIRE ALARM CONTROL PANEL <br />PROVIDE DEDICATED PHONE LINE <br />FAA <br />FIRE ALARM ANNUNCIATOR <br />EMERGENCY LIGHT <br />FIRE EXTINGUISHER IN CABINET <br />FIRE HOSE STATION <br />c <br />E <br />r- <br />LM <br />in <br />$ <br />N <br />N <br />0 <br />co <br />x <br />o� <br />ca <br />c <br />c <br />0 <br />0 <br />U <br />04- <br />C0 <br />'U <br />W <br />oa <br />�o <br />JCl) <br />M <br />J <br />W <br />0 a <br />4 <br />w <br />r � a <br />V <br />M <br />O o <br />a <br />z <br />o <br />d <br />>> <br />c <br />N <br />(0 <br />J <br />J <br />O <br />(15 <br />0 <br />O <br />r- <br />LL <br />J <br />U <br />c <br />c <br />M <br />'o <br />a <br />0 <br />- -- <br />N <br />Q <br />v- <br />N <br />0 <br />H <br />LL <br />U <br /><C <br />(n <br />Q <br />Q <br />OL <br />Ir <br />0 <br />Q <br />Qo <br />>LL <br />U <br />3: <br />w <br />O <br />0- <br />_J <br />�� <br />U) <br />o <br />pim= <br />W <br />J <br />X <br />O <br />0 <br />Q <br />a <br />U <br />c <br />N <br />(a <br />Revisions: <br />05-25-10 OWNER <br />REQUESTED <br />CHANGES <br />Z <br />Q <br />J <br />Q. <br />W <br />LL <br />Q <br />W <br />W <br />LL <br />J <br />Project Number <br />10032 <br />Date <br />04-06-10 <br />Sheet Number <br />LS-1 <br />