Laserfiche WebLink
I I 1 I 1 I 1, !1 I ---1 I 1 1" V I 'I I 1 11 - 11 1 1 1 <br />MINIMUM INTERIOR FINISH CLASSIFICATION <br />INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE <br />THEIR FLAME SPREAD AND SMOKE -DEVELOPED INDEXES PER FBC TABLE 803.5 <br />WITH ASTM E 84. SUCH INTERIOR FINISH MATERIALS SHALL BE GROUPED IN CLASSES IN <br />INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY, <br />ACCORDANCE WITH <br />OCCUPANCY CLASSIFICATION <br />EXIT ENCLOSURES <br />CORRIDORS <br />ROOMS <br />CLASS A <br />CLASS B <br />CLASS C <br />FLAME <br />SMOKE <br />FLAME <br />SMOKE <br />FLAME <br />SMOKE <br />MERCANTILE (GROUP M) (SPRINKLERED) <br />B <br />C <br />C <br />0-25 <br />0-450 <br />25-75 <br />0-450 <br />76-200 <br />0-450 <br />ROOM FINISH SCHEDULE <br />RM # <br />ROOM TYPES <br />FLOOR <br />BASE <br />WALLS <br />CEILINGS <br />REMARKS <br />MATL, <br />COMMENT <br />MATL, <br />HGT, <br />100 <br />SALES <br />VCT <br />VINYL <br />PAINT <br />LATEX ENAMEL <br />2X4 ACT <br />9'-0' A.F.F. <br />101 <br />PHARMACY <br />VCT <br />VINYL <br />PAINT <br />LATEX ENAMEL <br />2X4 ACT <br />9'-0' A.F.F. <br />102 <br />TOILET ROOM <br />VCT <br />VINYL <br />PAINT <br />SCRUBBABLE LATEX <br />2X4 ACT <br />9'-0' A.F.F. <br />6' MIN, VINYL BASE <br />103 <br />SECURE DRUG ROOM <br />VCT <br />VINYL <br />PAINT <br />LATEX ENAMEL <br />2X4 ACT <br />9'-0' A.F.F. <br />104 <br />DATA <br />VCT <br />VINYL <br />PAINT <br />LATEX ENAMEL <br />2X4 ACT <br />9'-0' A.F.F. <br />UNDERSIDE OF ROOF DECK <br />1/4' CONT, SEALANT <br />R-7.8 RIGID INSUL. <br />EXIST, STANDARD 8' C.M.U. <br />CONSTRUCTION <br />5/8' GYPSUM WALL <br />BOARD (M.R. BOARD ON <br />TOILET ROOM SIDE) ON <br />3./4' METAL FURRING <br />INTERIOR FINISHES - SEE <br />SCHEDULE <br />SUSPENDED AC❑UTICAL <br />CEILING <br />EXIST, CEMENT PLASTER <br />1/4' CUNT, SEALANT <br />1 EXTERIOR WALL TYPE "A" <br />—3 1 SCALEt 3'-1'—O' <br />UNDERSIDE OF ROOF OR <br />FLOOR DECK <br />1/4' CONT, SEALANT <br />METAL RUNNER <br />SUSPENDED ACOUTICAL <br />CEILING <br />FINISHES - SEE <br />SCHEDULE <br />5/8' TYPE 'X' GYPSUM <br />WALL BOARD ON BOTH <br />SIDES (M,R. BOARD ON <br />TOILET ROOM SIDE)(COPE <br />TOP TO DECK PROFILE) <br />3-5/8' METAL STUDS @ <br />24' O.C. MAX. <br />3-1/2' SOUND <br />ATTENUATION INSULATION <br />METAL RUNNER <br />1/4' CONT. SEALANT <br />ONE HOUR PARTITION TYPE "B" <br />SCALES 3'-1'-0' <br />UNDERSIDE OF ROOF DECK <br />METAL RUNNER <br />3-5/8' METAL STUDS @ <br />24' O,C. MAX, <br />FINISHES - SEE <br />SCHEDULE <br />SUSPENDED ACOUSTICAL <br />CEILING <br />5/8' GYPSUM WALL <br />BOARD ON BOTH SIDES <br />METAL RUNNER <br />1/4' CONT,SEALANT <br />INTERIOR PARTITION TYPE T' <br />SCALD 3'-1'—O' <br />UNDERSIDE OF FLOOR <br />DECK <br />METAL RUNNER <br />6' METAL STUDS @ 24' <br />O.C, MAX. <br />FINISHES - SEE <br />SCHEDULE <br />SUSPENDED ACOUSTICAL <br />CEILING <br />5/8' GYPSUM WALL <br />BOARD ON BOTH SIDES <br />(M,R, BOARD ON TOILET <br />ROOM SIDE> (COPE TOP <br />TO DECK PROFILE) <br />5-1/2' SOUND <br />ATTENUATION INSULATION <br />METAL RUNNER <br />1/4' CONT, SEALANT <br />4 INTERIOR PARTITION TYPE "D" <br />A-3 I SCALEs 7-1'-0' <br />'UDS @ <br />_L <br />SIDES <br />INT <br />UNDERSIDE OF ROOF OR <br />FLOOR DECK <br />1/4' CONT, SEALANT <br />METAL RUNNER <br />SUSPENDED ACOUTICAL <br />CEILING <br />FINISHES - SEE <br />SCHEDULE <br />5/8' GYPSUM WALL <br />BOARD ON BOTH SIDES <br />(M.R. BOARD ON TOILET <br />ROOM SIDE) (COPE TOP <br />TO DECK PROFILE) <br />3-5/8' METAL STUDS @ <br />24' O,C. MAX, <br />3-1/2' SOUND <br />ATTENUATION INSULATION <br />METAL RUNNER <br />1/4' CONT. SEALANT <br />6 INTERIOR PARTITION TYPE "F" <br />—3 J SCALD 3'-1',-O' <br />MAXIMUM ALLOWABLE HEIGHT <br />OF INTERIOR NON —BEARING <br />METAL STUD WALLS <br />BASED ON DIETRICH STEEL STUDS <br />CRITERIA, LATERAL LOAD = 5 PSF <br />MAXIMUM ALLOWABLE DEFLECTION = L/240 <br />1 LAYER (MIN,) GYPSUM BD. EACH FACE <br />FULL HEIGHT <br />STUD <br />MAXIMUM HEIGHT PER STUD SPACING <br />SIZE <br />STYLE <br />GAUGE <br />12' <br />16' <br />24' <br />2 1/2 <br />STN <br />25 <br />11'-11, <br />11'-3' <br />10'-7' <br />2 1/2 <br />STE <br />20 DW <br />13'-2' <br />12'-1' <br />10'-9' <br />2 1/2 <br />STX <br />20 STR <br />13'-11' <br />121-10, <br />11'-7' <br />3 5/8 <br />STN <br />25 <br />15'-4' <br />14'-4' <br />13'-5' <br />3 5/8 <br />STE <br />20 DW <br />17'-1' <br />15'-8' <br />14'-0' <br />3 5/8 <br />STX <br />20 STR <br />17'-10' <br />16'-5' <br />14'-9' <br />4 <br />STN <br />25 <br />16'-5' <br />15'-4' <br />14'-2' <br />4 <br />STE <br />20 DW <br />19'-0' <br />17'-6' <br />15'-7' <br />4 <br />STX <br />20 STR <br />19'-11' <br />18'-4' <br />16'-5' <br />6 <br />STN <br />25 <br />22'-1' <br />19'-9' <br />16'-9' <br />6 <br />STE <br />20 DW <br />25'-G' <br />23'-2' <br />20'-3' <br />6 <br />STX <br />20 STR <br />26'-9' <br />24'-6' <br />21'-7' <br />20 DW GAUGE = 30 MILS, 20 STR GAUGE = 33 MILS <br />GENERAL NOTES, <br />11 DIMENSIONS ARE FROM FACE OF WALL UNLESS OTHERWISE NOTED. <br />2. FOR PLUMBING FIXTURE SPECIFICATIONS AND NOTES, SEE PLUMBING <br />DRAWINGS, <br />3, LAVATORIES AND SINKS SHALL BE INSTALLED A MINIMUM OF 4' <br />FROM FINISHED SIDE WALLS. FAUCETS SHALL BE INSTALLED WITH <br />A MINIMUM OF 5' FROM THE OUTLET TO THE FLOOD RIM OF SINKS. <br />4. WATER CLOSETS SHALL BE INSTALLED IS' FROM FINISHED SIDE <br />WALLS TO CENTERLINE OF FIXTURE. <br />5. BASIS OF DESIGN FOR ACCESSORIES IS BOBRICK WASHROOM <br />EQUIPMENT, INC. <br />6. MIRRORS TO BE 1/4' QUALITY q2 CLEAR FLOAT GLASS WITH FULL <br />SILVER, COPPER AND ORGANIC COATINGS. PROVIDE UNIFORMLY <br />GROUND AND POLISHED EDGES, <br />7. BASIS OF DESIGN FOR SIGNAGE IS HEINRICH WILKE GMBH (HEWI), <br />ACCESSORY NOTES, <br />1. GRAB BARS SHALL BE PROVIDED PER FEDERAL ADA REQUIREMENTS <br />AND THE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. <br />GRAB BARS SHALL BE LOCATED 33' ABOVE FINISHED FLOOR, SHALL <br />HAVE AN OUTSIDE DIAMETER OF 1-1/2', AND SHALL PROVIDE 1 1/2' <br />OF CLEARANCE BETWEEN THE RAIL AND THE WALL, GRAB BARS <br />SHALL BE SO DESIGNED AN SUPPORTED AS TO WITHSTAND A LOAD <br />OF NOT LESS THAN 250 POUNDS APPLIED AT ANY POINT, DOWNWARD <br />OR HORIZONTALLY. GRAB BARS BEHIND TOILETS SHALL BE 56' <br />LONG. GRAB BARS AT SIDE WALLS SHALL BE 42' LONG, 12' FROM <br />THE BACK WALL, <br />2. MEN'S ROOM DOOR SHALL HAVE MALE SYMBOL AND HANDICAPPED <br />SYMBOL. WOMEN'S ROOM DOOR SHALL HAVE FEMALE SYMBOL AND <br />HANDICAPPED SYMBOL, UNISEX ROOM DOOR SHALL HAVE UNISEX <br />SYMBOL AND HANDICAPPED SYMBOL, <br />ACCESSORY SCHEDULE <br />ITEM <br />MODEL # <br />MOUNTING <br />(D <br />TISSUE DISPENSER <br />i B-2740 <br />SURFACE @ 21' A.F.F. @ CNTR, <br />SANITARY NAPKIN <br />O <br />DISPOSAL, SURFACE <br />B-254 <br />TOP @ 27' A,F.F. <br />MOUNTED (WOMEN ONLY) <br />3A <br />PAPER TOWEL DISPENSER <br />& WASTE RECEPTACLE, <br />B-3944 <br />RECESSED @ 40' A.F.F. @ OPN'G, <br />RECESSED MOUNTED <br />TOWEL DISPENSER <br />@PAPER <br />& WASTE RECEPTACLE, <br />B-3699 <br />SURFACE @ 40' A.F.F. @ OPN'G, <br />SURFACE MOUNTED <br />�4 <br />SOAP DISPENSER, <br />SURFACE MOUNTEDB-132 <br />SURFACE @ 40' A.F.F. @ VALVE <br />O5 <br />MIRROR & SHELF COMBO <br />B-292 1830 <br />BOTTOM OF REFLECTING SURFACE <br />@ 40' A.F.F. <br />O <br />DOUBLE HOOK <br />B-672 <br />SURFACE @ 40' A.F.F. @ CNTR. <br />7® <br />GRAB BARS - 36' LONG <br />B-5806 <br />SURFACE - SEE ACCESSORY NOTE #1. <br />7B <br />GRAB BARS - 42' LONG <br />B-5806 <br />SERIE <br />SURFACE - SEE ACCESSORY NOTE #I, <br />�8 <br />DOOR SIGNS <br />INSTALLED ON WALL ADJACENT TO <br />LATCH SIDE OF 000R. SURFACE, <br />CENTER @ 60' A.= .F. - SEE <br />ACCESSORY NOTE #2 <br />UNISEX <br />710.150ASK <br />#8 BLACK <br />MALE SYMBOL <br />710.150ASK <br />#8 BLACK <br />FEMALE SYMBOL <br />710.150,2SK <br />#8 BLACK <br />HANDICAPPED SYMBOL <br />710.150.3SK <br />#8 BLACK <br />6,-7' <br />-6' <br />3'-0' <br />I 40 1 � ■ mm"M ■ � I a � ■ MONO* ■ "M it Oar <br />VERIFY EXACT <br />CLEARANCES <br />REQUIRED IN <br />WALLS FOR <br />ACCESSORIES <br />I � <br />I 1 <br />i 6'-0" CLEAR <br />TOILET <br />1 I 02 <br />I I <br />ICI i A83 i 4 1 <br />i - -- -- — -- -- i- :_--, : — — <br />I 51 <br />3B f-- — <br />I I I <br />K-7""'N TOILET ROOM PLAIN <br />A — 3 SCALED i/8•-i'-0' <br />ALL PIPES UNDER LAVATORY <br />SHALL BE NSULATED, NO SHARP <br />EDGES OR ABRASIVE SURFACES <br />UNDER LAVATORY <br />g TOILET ROOM ELEVATION <br />01 <br />I <br />co <br />LO <br />Q CV <br />o }- w co <br />CM <br />z � 0 <br />O <br />E� <br />Q CL <br />J_ <br />Q W Mr <br />w CL _q - <br />Q 0(L <br />U cl) N <br />Revisions: <br />� <br />LLJ <br />Q <br />W W <br />C) <br />C/) 06 <br />V / W <br />FL <br />O Q <br />O <br />w <br />Project Number <br />10032 <br />Date <br />E: <br />04-06-10 <br />Sheet Number <br />A-3 <br />