My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6834 Gall Blvd A
Zephyrhills
>
Building Department
>
Building Plans
>
6834 Gall Blvd A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 3:19:55 PM
Creation date
2/18/2025 3:31:02 PM
Metadata
Fields
Template:
Building Plans
Street #
6834
Location
Gall Blvd A
Contractor
Jovanovic & Lyons, LLC
Building Plans - Permit #
6855
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I II 11 l fill¢! IM!1I 1 !11 1 1 1 1- "11!' 1!"' 111 I11 I I N 1 I.1 I.. I <br />MIN 6" EXTENSION <br />ATTACHED TO DIFFUSER OR <br />SQUARE TO ROUND <br />SQUARE TO - <br />ROUND ADAPTER <br />(WHEN APPLICABLE) <br />PROVIDE PLASTER <br />FRAME FOR MOUNTING <br />IN HARD CEILINGS <br />(WHEN APPLICABLE) 7,v, <br />ZGYP. BOARD <br />CEILING <br />ROOF TOP PACKAGE UNIT SCHEDULE <br />UNIT NO. <br />(MARK) <br />TOTAL <br />SUPPLY <br />(CFM) <br />OUTSIDE <br />AIR <br />(CFM) <br />EXT./TOT. <br />S•P• <br />(IN. W.G.) <br />TOTAL <br />CAPACITY <br />(MBH) <br />HEATING <br />CAPACITY <br />(MBH) <br />ELEC. HEAT <br />(KW) <br />E.A.T.(°F) <br />L.A.T.(`F) <br />INDOOR FAN <br />MCA/MFS <br />ELECTRICAL <br />DATA <br />(V/PH/HZ) <br />EER <br />DESIGN <br />MANUF. <br />MODEL <br />NOTES <br />D.B./W.B. <br />D.B./W,B, <br />DRIVE <br />HP <br />RPM <br />RTU-1 <br />1,760 <br />260 <br />0.4/ 1 .0 <br />50.1 <br />1 59.4 <br />1 17.4 <br />78.8/64.7 <br />58.0/55.0 <br />1 BELT <br />1.0 <br />1,750 <br />58.6/60 1208/3/60 <br />1 11.01 <br />TRANE <br />ITSCO48E3 <br />1 1,2 <br />NOTES: <br />1. PROVIDE 7 DAY PROGRAMMABLE THERMOSTATS LOCATION SHOWN ON PLAN. <br />2. PROVIDE REMOTE TEMPATURE SENSOR LOCATION SHOWN ON PLAN. <br />EXHAUST FAN SCHEDULE <br />MARK <br />MFR. <br />MODEL <br />AREA SERVED <br />AIR FLOW <br />(CFM) <br />ST. PR. <br />(IN H20) <br />DRIVE <br />FAN SPEED <br />(RPM) <br />MOTOR <br />VOLTS/ <br />PHASE/HZ <br />NOTES <br />HP <br />RPM <br />EF-1 <br />GREENHECK <br />SP-B110 <br />TOILET <br />1 124 <br />1 .05 <br />1 DIRECTI <br />950 <br />115/1401 <br />50 <br />1 115/1/601 <br />1,2 <br />NOTES: <br />1 . INTERLOCK FAN WITH RTU-1 . <br />2. PROVIDE WITH UNIT MOUNTED DISCONNECT AND GRAVITY BACKDRAFT DAMPER. <br />i CONNECT INNER DUCT <br />WITH PANDUIT DRAWBAND <br />AND SEAL WITH <br />TAPE/MASTIC OUTERDUCT <br />AT NECK CONNECTION <br />PROVIDE THERMAL <br />INSULATION BLANKET IF <br />1177 INSTALLED IN <br />UNCONDITIONED SPACE <br />LOUVERED FACE <br />CEILING DIFFUSER <br />SUSPENDED LAY -IN <br />CEILING SYSTEM <br />DIFFUSER CONNECTION DETAIL <br />NOT TO SCALE <br />2 1 /2" EXTERIOR <br />INSULATION <br />�-- MAIN DUCT-SUPPLY/RETURN/EXHAUST �-- <br />- _ VOLUME DAMPER, <br />SEAL WITH TAPE AT I - - - TAG WITH INDICATOR <br />SEAM TAPE <br />FLEXIBLE DUCT: CONNECT <br />INNER DUCT WITH NYLON <br />DRAWBAND AND SEAL NECK <br />CONNECTION WITH TAPE <br />RIGID PIPE: CONNECT WITH <br />SCREWS AND SEAL NECK <br />CONNECTION WITH TAPE <br />1 <br />LOCKING <br />QUADRANT TO <br />BE EXPOSED <br />BELL MOUTH COLLAR <br />BRANCH DUCT TAKE -OFF DETAIL <br />CAULK <br />WATER <br />DUCT <br />C LA <br />EXTERIOR <br />NOT TO SCALE <br />AIR DISTRIBUTION DEVICE SCHEDULE <br />MARK <br />SERVICE <br />DESCRIPTION <br />MATERIAL <br />MANUF. <br />MODEL <br />NOTES <br />S-1 <br />SUPPLY <br />SQUARE CONE DIFFUSER <br />ALUMINUM <br />PRICE <br />SCD <br />1,2,3 <br />S-2 <br />SUPPLY <br />LOUVERED FACE GRILLE <br />JALUMINUM <br />PRICE <br />620 <br />1,2,3 <br />R-1 <br />RETURN <br />FILTER FRAME <br />ALUMINUM <br />PRICE <br />630FF <br />1,2,3 <br />NOTES: <br />1. PROVIDE OPPOSED BLADE VOLUME DAMPER. <br />2. STANDARD BAKED -ON WHITE ENAMEL FINISH. <br />3. PROVIDE 24X24 CEILING MODULE AS REQUIRED <br />L CAP WITH <br />_T-IN DAMPER <br />EXHAUST WALL CAP DETAIL <br />NOT TO SCALE <br />ri( rlly <br />. S sTR'gA <br />MAXIMUM SAG OF - <br />1 /2" PER FOOT OF <br />SUPPORT SPACING <br />NOTE: HANG ALL DUCT PER 2005 <br />SMACNA HVAC DUCT CONSTRUCTION <br />STANDARDS METAL AND FLEXIBLE <br />5/16" SCRE <br />(TYP.) <br />NF�T/D <br />N <br />FLEXIBLE DUCT HANGING DETAIL <br />NOT TO SCALE <br />STRAP & BEND 24" DIA <br />MAX. <br />NOTE: HANG ALL DUCT PER 2005 <br />SMACNA HVAC DUCT CONSTRUCTION <br />STANDARDS METAL AND FLEXIBLE <br />(�4 DUCT HANGING DETAIL <br />M-2 NOT TO SCALE <br />OAD RATED <br />ASTENERS <br />DESIGN CONDITIONS <br />SUMMER <br />WINTER <br />DB(`F) <br />WB(`F) <br />DB('F) <br />OUTDOOR <br />93.0 <br />77.0 <br />40.0 <br />INDOOR <br />75.0 <br />62.5 <br />68.0 <br />VENTILATION RATE TABLE <br />BASIS: ASHRAE STANDARD 62.1 -2007. <br />RTU -1 <br />SALES: 383 SQ. FT. X 0.12 CFM/SQ. FT. = 45.9 CFM <br />3 PEOPLE X 7.5 CFM/PERSON = 22.5 CFM <br />PHARMACY: 754 SO. FT. X 0.18 CFM/SQ. FT. = 135.7 CFM <br />5 PEOPLE X 5 CFM/PERSON = 25.0 CFM <br />EQUIPMENT: 11 SQ. FT. X 0.06 CFM/SQ. FT. = 0.6 CFM <br />TOTAL OUTSIDE AIR REQUIRED: 229.7 CFM <br />VENTED CAP RTU-# <br />CLEAN <br />OUT A DRAIN LINE SHALL BE <br />PVC PIPE ROUTE - AT LEAST THE SAME <br />TO NEAREST B SIZE AS THE NIPPLE <br />CONDENSATE RISER - ON THE UNIT DRAIN <br />DESIGNER'S NOTE: <br />AHU TYPE <br />A <br />B <br />DRAW THRU <br />2" + X <br />X + 1 " <br />BLOW THRU <br />2" MIN. <br />I 2X <br />WHERE X = STATIC PRESSURE IN DRAIN PAN <br />UNIT DRAIN TRAP DETAIL <br />NOT TO SCALE <br />I I A "I ;ER SUPPORTS <br />2 GUAGE <br />G RAL <br />KDRAFT DAMPER <br />)ISCONNECT <br />SWITCH <br />�-LIL_ING <br />TYPICAL CEILING EXHAUST FAN DETAIL <br />NOT TO SCALE <br />GENERAL <br />NOTES: <br />1. INSTALLATION SHALL COMPLY <br />WITH ALL LOCAL, <br />STATE AND FLORIDA <br />ENERGY <br />CODES. <br />2. SYSTEM <br />LAYOUT IS GENERAL <br />IN NATURE AND <br />MAY NOT REFLECT <br />ACTUAL <br />ROUTING OR OFFSETS REQUIRED TO <br />FIT IN SPACES. MAKE <br />MINOR <br />ADJUSTMENTS WITH <br />NO ADDITIONAL COSTS TO THE OWNER. <br />3. PROVIDE <br />INDEPENDENT TEST <br />AND BALANCE OF <br />SYSTEMS UPON <br />COMPLETION OF WORK. <br />AIR DISTRIBUTION NOTES: <br />1 • DUCT SIZES ARE CLEAR INSIDE DIMENSIONS AND SHALL BE 1-1/2" <br />DUCTBOARD; INSTALLED AND INSULATED PER "SMACNA" STANDARDS AND <br />ALL LOCAL AND STATE CODES. <br />2. ROUND RUNOUTS TO GRILLES (AND BACKS OF GRILLES) TO BE WRAPPED <br />WITH 2.2" THICK KNAUF DUCTWRAP WITH FSK JACKET (OR EQUAL). <br />3. FLEXIBLE DUCTWORK TO BE ATCO RUBBER PRODUCTS (OR EQUAL) <br />INSULATED FLEX DUCT WITH R=6 VALUE. <br />4. PREPARE SHOP DRAWINGS VERIFING CLEARANCE SPACE AVAILABLE, <br />OFFSETS REQUIRED, STRUCTURAL OPENINGS, AND WORK BY OTHER <br />TRADES PRIOR TO FABRICATION OF DUCTWORK. COORDINATE WITH <br />ROOF TRUSSES/STRUCTURE. PRESSURE TEST ALL DUCTWORK FOR <br />LEAKS. RETURN DUCT SHALL BE TESTED UNDER NEGATIVE <br />PRESSURE. <br />EQUIPMENT NOTES: <br />1. PROVIDE FULL SIZE CONDENSATE DRAINS FROM ALL UNITS TO NEAREST <br />OUTLET. SLOPE ALL CONDENSATE DRAIN PIPING 1 /8" INCH PER FOOT. <br />2. INSTALL ALL EQUIPMENT, PIPING AND DUCTWORK SUCH THAT <br />MANUFACTURERS' RECOMMENDED CLEARANCES ARE MET FOR ALL ACCESS <br />PANELS, COILS, MOTORS, FANS, BELTS, FILTERS, AND AIR INTAKES. <br />3. PROVIDE REMOTE SENSOR, INTERLOCK WITH THERMOSTAT AND PROGRAM TO <br />ENERGIZE UNIT ON SENSOR DEMAND. <br />HVAC LEGEND <br />SUPPLY, RETURN DUCT <br />SUPPLY GRILLE <br />RETURN GRILLE <br />OPPOSED BLADE VOLUME DAMPER <br />Z�-- UNDERCUT DOOR 3/4" <br />3/4" <br />FS FIRESTAT <br />�T THERMOSTAT <br />REMOTE TEMPATURE SENSOR <br />X-1 DIFFUSER TAG <br />CFM X = S-SUPPLY <br />NK NK = NECK SIZE X = R-RETURN <br />X_# EQUIPMENT TAG <br />X = EF - EXHAUST FAN <br />X = RTU - ROOFTOP UNIT <br />::DETAIL NUMBER <br />SHEET NUMBER WHERE SHOWN <br />MECHANICAL PERMIT DOClM1ENTS02010 <br />AIRCO MECHANICAL. INCORPORATED DESIGN. <br />Certificate of Authorization No.: 27407 <br />ETAILS <br />THESE MECHANICAL DOCUMENTS, DESIGNS, NOTES, BUILD. <br />°NRCO <br />SOLE PROPERTY OF SPECIFICATIONS <br />ROD MECHANCAL. INC. AND M E C H A N I C A L_ SOLUTION. - <br />SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR <br />WRITTEN PROJECTS, IN OF AIM HEFFFEI-MRE"PE. THE C 14100 HONEYWELL ROAD P: 727-547-9700 <br />ALL <br />IN ACCORDANCE WITH U.S. COPYRIGHT°AND LARGO, FLORIDA 33771 F: 727-547-9754 <br />PATENT LAWS. USE WILL BE PROSECUTEDIZED TO THE�FU°LLDUCTIOEXTENTa° WWW.AIRCO-MECHANICAL.COM <br />THE LAW. <br />U� <br />� <br />O <br />c <br />° <br />x <br />J LL <br />�__ <br />.g <br />a <br />m <br />N <br />W <br />N <br />C <br />C <br />a <br />s <br />�a <br />0 <br />JM <br />J <br />0 <br />U a <br />■ fn <br />Ooco <br />Z <br />Q <br />C <br />Q <br />CD <br />CD <br />a' <br />`J <br />d <br />J <br />pR <br />C <br />Oto <br />G <br />J <br />o <br />M1 <br />J <br />1-U_ <br />oa <br />.2 <br />'o <br />a <br />M <br />0 <br />O <br />0 <br />N <br />LO <br />O <br />N <br />er <br />� M <br />w <br />QN� <br />O <br />p <br />�O <br />O <br />Q <br />> -UJ <br />w <br />J C <br />Z) J <br />LLJ <br />_ <br />m J <br />Q <br />^^ <br />1� <br />J <br />O�w <br />co N <br />co <br />co <br />Revisions: <br />f^,w <br />w / <br />W <br />4 <br />UZ< <br />�- <br />Q W W <br />=JD <br />W0Z <br />� = Q <br />CU <br />U) <br />Project Number <br />234 <br />Date <br />03-25-10 <br />Sheet Number <br />M-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.