Laserfiche WebLink
A/C <br />DISCONNECT <br />/ GFWVP <br />SUITE u5 VVIL; <br />ADD WP ADD <br />BLOCKING BLOCKING P <br />I � <br />DATA 0 <br />ADD <br />BLOCKING <br />I / I <br />I <br />I <br />sD GREAT <br />ROOM DATA <br />© ETV <br />ADD <br />° GFI GFI BLOCKING <br />O.S IPTAY----- M <br />WP BATH <br />° \ <br />3-BULB LL GFI GFI <br />L _ <br />GFI <br />i <br />L GFI ADD <br />( <br />° a BLOCKING <br />RANGE <br />220V ° GFI DINING <br />MICR WAVE UNDER SINK AREA <br />CL GFI SWITCH FOR <br />— DISPOSAL <br />\ GFI 20 AMP DED. <br />OUTLET GFI <br />KITCHEN <br />GFI <br />ADD L <br />BLOCKING REF. <br />GFI GFI � — — � <br />CL ADD <br />BEDROOM 2 Q BLOCKING <br />CaF J <br />-BULB <br />sD ALL BEDROOM 3 <br />/ \ BATH <br />0 <br />LNDY 0 HOV LL HA L <br />1 V GFI ©F_ <br />y ISCONNECT <br />LL _ J _ EXT STE PLUS <br />L NL BEDROOM <br />12 V � j i;'I I M I <br />\3 ADD <br />LLGFI — — BLOCKING <br />WH WH 42" A.F.F. 42" A.FIF. (SD) <br />O DISCONNECT <br />— EYLESS-_ <br />LIGHT FIX. EXT STELA <br />PLUS BATH <br />FOYER 3-BULB <br />VP <br />\3 3 M ® G <br />REF <br />2 CAR GARAGEa B FOR <br />GFI eV CHIMES ❑ I GFI �J _L— = <br />-WET <br />44" <br />ELECTRICAL ELECTRICAL Z PRE -WIRE FOR BAR A.F.F. <br />METER (V.I.F.) M PANEL ON GARAGE DOOR _ <br />[—­2X4WALL — — — — —OPENER — — — — — <br />fM <br />GFI \ i r> <br />ADD <br />_ WP/ GFI WP BLOCKING <br />IRRIGATION Or DATA <br />(TIMER o N EXT STE PLUS <br />\ ENTRY LIVING ROOM <br />I PVC <br />------ <br />= ICK _ -- <br />�TI <br />I <br />FIRST FLOOR ELECTRIC PLAN <br />SCALE: 1 /4"=V-0" <br />r <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />OR COPPER <br />OR <br />2-4/0 ALUMINUM 1504MP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. I BREAKER <br />1 /2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />�II�i iii <br />-1 I_f__III=1 <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL KEY <br />k� DUPLEX CONVENIENCE OUTLET <br />�� WEATHERPROOF DUPLEX OUTLET <br />Fl GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />t, FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />Owr VAPOR PROOF LIGHT FIXTURE <br />�vc LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />vll EXHAUST FAN/LIGHT COMBINATION <br />cN CHIMES (OPTIONAL) <br />0 PUSHBUTTON SWITCH (OPTIONAL) <br />O COMBINATION SMOKE / CO2 DETECTOR <br />so SMOKE DETECTOR <br />< TELEPHONE (OPTIONAL) <br />0 TELEVISION (OPTIONAL) <br />IV ELECTRIC METER <br />= ELECTRIC PANEL <br />DISCONNECT SWITCH <br />JUNCTION BOX <br />STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2020 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ............ 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES,, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O20 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES'IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2020 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />N <br />Q o <br />Q <br />0 <br />0 <br />0 <br />0 <br />N <br />0 <br />a <br />Oa <br />O <br />O <br />� <br />mj <br />CL <br />LL <br />U <br />w <br />M <br />to <br />`� <br />u <br />U) <br />0110 <br />LLMw <br />w <br />w <br />CL <br />_o <br />U) <br />W <br />G <br />z <br />Z <br />O <br />Q <br />� <br />Wz <br />o <br />aaaaa <br />COMMUNITY: <br />LINKS <br />@ CALUSA SPRINGS <br />PLAN # 6120 <br />RELEASED:12/10/20 <br />SHEET <br />E '� . <br />