1 <br />M2.0 <br />►•'FAU lli <br />HVAC DETAIL <br />SCALE: NOT TO SCALE <br />l'� <br />1A X 1A ISM <br />MOMP <br />Ni uwi <br />.=. <br />b <br />WD <br />1 RTU DETAIL <br />M 2.0 / SCALE: NOT TO SCALE <br />or tr �Wll <br />DINATE DUCT ROUTING <br />JGH OPEN WEB JOISTS. <br />PROVIDE CHASE I1� <br />H.V.A.C. DUCT TO <br />ELECTRICAL ROOM. <br />FLOOR FRAMING <br />OFFICE AND <br />ROOFTOP OHEAT <br />PUMP <br />M P <br />UNIT <br />SCHEO LE <br />UNIT <br />DESCRPTTON <br />ST R <br />c NG CAPACITY <br />HEATING CAPACITY <br />POWER <br />TRANE MODEL <br />REMARKS <br />SUPPLY <br />OA MIN <br />TOTAL <br />SENSIBLE <br />KW <br />OUTPUT <br />MTR HP <br />VOLTAGE <br />MCA/MCOP <br />RTU-1 <br />PACKAGED ROOFTOP UNIT W/ HEAT PUMP <br />4000 CFM <br />550 CFM <br />0.5 IN <br />121.0 MBH <br />94.8 MBH <br />9.59 <br />108 MBH <br />2 HP <br />208-3-60 <br />50.4/60 <br />WSC120A3 <br />1, 2, 3, 4, 5 <br />RTU-2 <br />PACKAGED ROOFTOP UNIT W/ HEAT PUMP <br />4000 CFM <br />550 CFM <br />0.5 IN <br />121.0 MBH <br />94.8 MBH <br />9.59 <br />108 MBH <br />2 HP <br />208-3-60 <br />50.4/60 <br />WSC120A3 <br />1, 2, 3, 4, 5 <br />REMARKS: <br />1. PROVIDE UNIT WITH ROOF CURB, DISCONNECT, 115V GFI SERVICE OUTLET, AND LOW AMBIENT <br />COOLING <br />CONTROL. <br />2. RTU'S FAN SHALL BE SET TO RUN IN CONTINUOUS MODE. <br />3. COOLING/HEATING RATED AT 80/67 T AND AMBIENT 95 'F. <br />4. PROVIDE RTU UNIT WITH ELECTRONIC PROGRAMMABLE THERMOSTAT. <br />5. REFER TO SPECIFICATION FOR ADDITINAL INFORMATION. <br />EXHAUST FAN <br />SCHEDULE <br />ELECTRICAL <br />OPER <br />MARK <br />LOCATION <br />MFR <br />MODEL <br />CFM <br />S.P. <br />WT <br />REMARKS <br />H.P. <br />VOLT/PH/HZ <br />IN W.G. <br />LBS <br />EF-1 <br />WOMENS RESTROOM <br />LOREN COOK <br />GC-164 <br />100 <br />0.625 <br />145 WATTS <br />120 1 60 <br />15 <br />1,2,3,4 <br />EF-2 <br />MEN'S RESTROOM <br />LOREN COOK <br />GC-164 <br />100 <br />1 0.625 <br />1 145 WATTS <br />120 1 60 <br />15 <br />1,2,3,4 <br />REMARKS: <br />1. PROVIDE FACTORY INSTALLED DISCONNECT SWITCH AND BACKDRAFT DAMPER. <br />2. CONNECT THE EXHAUST FAN TO THE LIGHT SWITCH <br />3. PROVIDE GEMINI MODEL ROOF CAP. <br />4. FAN SHALL BE INTERLOCKED WITH LIGHT SWITCH <br />DIFFUSERS REGISTERS <br />GRILLES <br />& LOUVERS <br />UNIT <br />SIZE <br />THROW <br />MODEL <br />OUTLET <br />DAMPER <br />FINISH <br />FRAME <br />REMARKS <br />INCHES <br />(1) <br />CONNECTION <br />(4) <br />SA -A <br />12X12 <br />4 WAY <br />SMD 1 4A/B12/SR3 <br />10" <br />YES <br />WHITE <br />SM <br />1,2,3,4 <br />SA-B <br />10x10 <br />2 WAY <br />SMD/1 /4A/B1 2/SR3 <br />10" <br />YES <br />WHITE <br />SM <br />1,2,3,4 <br />REMARKS: <br />1. E.H. PRICE. <br />2. PROVIDE SQUARE TO ROUND NECK ADAPTER WITH DAMPER. EH PRICE MODEL SR3. <br />3. INDEPENDENTLY SUPPORT ALL DIFFUSERS, REGISTERS, AND GRILLES FROM STRUCTURE. <br />DO NOT REPLY ON CEILING TILE OR GRID. <br />4. TB=LAY-IN TEE BAR OR SM=CUT-IN SURFACE MOUNTED W/FLANGE AS REQUIRED. FIELD VERIFY. <br />GENERAL NOTES: <br />1. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL <br />POSSIBLE CONDITIONS. IT IS INTENDED THAT A COMPLETE HVAC SYSTEM BE PROVIDED WITH <br />ALL NECESSARY EQUIPMENT, APPURTENANCES AND CONTROLS COMPLETELY COORDINATED <br />WITH ALL DISCIPLINES. ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM <br />WITH THE REQUIREMENTS OF ALL STATE BUILDING CODES, THE NFPA 90A, 101 AND ALL <br />LOCAL AUTHORITIES AND THESE CONTRACT DOCUMENTS. THESE ITEMS SHALL BE FURNISHED <br />WITHOUT INCURRING ANY ADDITIONAL COST TO THE OWNER. THE WORD "PROVIDE" SHALL <br />MEAN FURNISH AND INSTALL. CAREFULLY REVIEW ALL CONTRACT DOCUMENTS AND THE <br />DESIGN OF OTHER TRADES BEFORE PREPARING SHOP DRAWINGS. <br />2. PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD <br />VERIFY ALL EXISTING CONDITIONS, DUCTWORK SIZES AND LOCATIONS, EQUIPMENT, ETC. SHOWN <br />ON THE DRAWINGS OR AFFECTING THIS WORK AND SHALL REPORT ANY DEVIATIONS TO THE <br />ARCHITECT. <br />3. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL <br />MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR <br />SUBMITTING SHOP DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES <br />SHOWN THEREIN. <br />4. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH <br />DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR <br />NON -FUSED) WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS AND <br />ELECTRICAL DRAWINGS. <br />5. ALL REQUIRED CONTROL WIRING NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE <br />INCLUDED AS PART OF THE MECHANICAL WORK. <br />6. UNLESS NOTED OTHERWISE, STARTERS, SMOKE DETECTORS, TRANSFORMERS, CONTROLS AND <br />CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED AND <br />INSTALLED BY THE MECHANICAL CONTRACTOR. <br />7. ALL FANS SUPPLYING MORE THAN 2000 CFM OF AIR TO ANY SPACE AND ALL RECIRCULATING <br />FAN SYSTEMS SERVING AREAS OF EGRESS SHALL BE INSTALLED WITH A SMOKE DETECTOR IN <br />THE SUPPLY DUCTWORK. THE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON <br />DETECTION OF SMOKE, AND SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL (IF BUILDING <br />IS SO EQUIPPED). IF THE BUILDING IS NOT PROVIDED WITH A FIRE ALARM SYSTEM, THE <br />SMOKE DETECTOR SHALL CAUSE A VISIBLE AND AUDIBLE ALARM SIGNAL IN A NORMALLY <br />OCCUPIED AREA. SMOKE DETECTOR TROUBLE CONDITIONS SHALL BE INDICATED VISUALLY OR <br />AUDIBLY IN A NORMALLY OCCUPIED AREA AND SHALL BE IDENTIFIED AS AIR DUCT DETECTOR <br />TROUBLE. IF A BUILDING FIRE ALARM SYSTEM IS INSTALLED, THE SMOKE DETECTOR SHALL BE <br />FURNISHED BY THE FIRE ALARM SYSTEM CONTRACTOR, MOUNTED IN THE DUCT BY THE <br />MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR. IF A BUILDING FIRE <br />ALARM SYSTEM IS NOT INSTALLED, THE SMOKE DETECTOR AND AUDIBLE/VISIBLE ALARM <br />SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. <br />8. INSTALL FIRE DAMPERS IN ALL RATED THROUGH WALLS, FLOOR AND CEILING PENETRATIONS. <br />REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OR RATED AREAS. PROVIDE <br />ACCESS DOORS IN DUCTWORK AT EACH FIRE DAMPER LOCATION. INSTALL SMOKE DAMPERS IN <br />ALL DUCT PENETRATIONS THROUGH SMOKE RATED WALLS. WHERE DUCTS PENETRATE WALLS <br />THAT CARRY BOTH FIRE AND SMOKE RATINGS, THE DAMPERS INSTALLED SHALL BE <br />COMBINATION FIRE AND SMOKE DAMPERS. ALL DAMPERS SHALL BE U.L. LABELED. <br />9. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S <br />RECOMMENDATIONS. <br />10. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE <br />YEAR AFTER CERTIFICATE OF OCCUPANCY. <br />11. EXHAUST DUCTWORK SHALL BE SHEET METAL AND SHALL NOT BE INSULATED UNLESS NOTED <br />OTHERWISE. <br />12. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST <br />ON CEILING TILES OR CEILING STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE <br />SHALL BE AS PER SMACNA STANDARDS. <br />13. FLEXIBLE DUCTWORK SHALL BE SIZED TO MATCH DEVICE NECK, PROVIDE ROUND GALVANIZED <br />STEEL DUCT RUNOUTS TO MAINTAIN MAXIMUM FLEXIBLE DUCT OF 5'-0" LONG. FLEXIBLE <br />DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE, AND SHALL BE ROUTED AND <br />SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. PROVIDE SQUARE <br />TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICE NECK WHEN REQUIRED. <br />14. ROUND AND FLEXIBLE DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH SPIN -IN <br />FITTINGS WITH AIR EXTRACTORS AND BALANCING DAMPERS. <br />15. PORTIONS OF DUCTWORK VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS <br />SHALL BE PAINTED FLAT BLACK. <br />16. DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. <br />CONTRACTOR SHALL ADJUST DUCT DIMENSIONS WHERE DUCT LINER IS USED M MAINTAIN <br />INSIDE CLEAR DIMENSIONS SHOWN ON DRAWINGS. <br />17. THE CONDENSATE SHALL DRAIN TO A SANITARY SEWER DRAIN TROUGH AN INDIRECT WASTE, <br />STORM SEWER DRAIN OR AN APPROVED FRENCH DRAIN. THE APPROVED <br />CORROSION -RESISTANT DISCHARGE PIPING SHALL NOT BE SMALLER THAN THE DRAIN PAN <br />CONNECTION ON THE APPROVED EQUIPMENT AND SHALL MAINTAIN A MINIMUM HORIZONTAL <br />SLOPE IN THE DIRECTION OF DISCHARGE OF NOT LESS THAN 1/8 UNIT VERTICAL IN 12 UNITS <br />HORIZONTAL (17.). <br />18. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND <br />BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. SUBMIT CERTIFIED <br />TEST AND BALANCE REPORT TO ARCHITECT FOR APPROVAL. <br />19. MANUAL OVER -RIDE CONTROL (EMERGENCY SHUT -DOWN) SWITCHES FOR ALL HVAC UNITS <br />SHALL BE LOCATED IN LOCKING COVER ADJACENT TO FIRE ALARM ANNUNCIATOR PANEL OR <br />OTHER LOCATION APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION. <br />20. ALL WORK SHALL BE COORDINATED AND PERFORMED WITH PRIOR APPROVAL FROM THE <br />OWNER TO SUIT HIS OPERATING CONDITIONS. <br />21. ANY WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE OF THE <br />HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING. <br />22. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, <br />DUCTWORK, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND <br />STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS <br />SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. <br />23. MOUNT THERMOSTATS 48" AFF UNLESS NOTED OTHERWISE. PROVIDE CLEAR LOCKING COVER <br />ASSEMBLIES FOR ALL THERMOSTATS. <br />24. LOCATIONS OF GRILLES, REGISTERS, & DIFFUSERS SHOWN ON THE DRAWINGS ARE <br />APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, SPRINKLER HEADS <br />ETC. <br />25. SLOPE ALL HORIZONTAL GAS FLUE PIPING MINIMUM 1/4" PER FOOT. <br />26. GAS FLUE PIPING SHALL BE TYPE "B" DOUBLE WALL FLUE, U.L. LISTED, EXCEPT FOR INDUCED <br />OR FORCED DRAFT EQUIPMENT, WHICH SHALL BE TYPE PS, METALBESTOS OR EQUAL. <br />27. TERMINATE ALL GAS FLUE PIPING THRU ROOF WITH TALL CONE FLASHING, STORM COLLAR, <br />AND WEATHER CAP. <br />28. PROVIDE ACCESS PANELS IN NON -ACCESSIBLE CEILINGS AND IN WALL STRUCTURE TO ALLOW <br />ADEQUATE ROOM FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF SYSTEM. <br />Greenberghrrow <br />1430 West Peachtree Street <br />Atlanta, GA 30309 <br />t: 404 6014000 f. 404 (601 3980 <br />COPYRIGHT NOTICE <br />This drawing is the property of the above <br />referenced Professional and is not to be used <br />for any purpose other than the specific <br />project and site named herein, and cannot <br />be reproduced in any manner without the <br />express written permission from the Professional <br />ISSUE/REVISION RECORD <br />DATE DESCRIPTION <br />12/5/07 ISSUED FOR PERMIT <br />T i%rv, c-oA 4- t6007== <br />PROFESSIONAL SEAL <br />PROFESSIONAL IN CHARGE <br />JUSTIN HARDY, P.E. 67084 <br />PROJECT MANAGER <br />STEVE ALLEN <br />QUALITY CONTROL <br />AMY HADLOW P.E. <br />DRAWN BY <br />STEVE ALLEN <br />PROJECT NAME <br />NAPA AUTO <br />PARTS <br />ZEPHYRHILLS <br />FLORIDA <br />6901 GALL BOULEVARD <br />41APA <br />r- <br />PROJECT NUMBER <br />20070208 <br />SHEET TITLE <br />MECHANICAL <br />DETAILS AND <br />SCHEDULES <br />SHEET NUMBER <br />M2mO <br />