Laserfiche WebLink
1 2 3 4 5 6 <br />STRUCTURAL DECK STRUCTURAL DECK STRUCTURAL DECK STRUCTURAL DECK <br />TOP TRACK TOP TRACK STRUCTURAL DECK <br />SOUND ATTENUATION <br />SAB RETAINER STRAP @ SIM BATTS (SAB) PER SOUND ATTENUATION <br />24"O.C. 1"x20 GA. SAB RETAINER STRAP @ SCHEDULE. BAITS (SAB) PER <br />CONT. SHEET METAL 24" O.C. 1 "X20 GA. SCHEDULE <br />CONT. SHEET METAL CEILING LINE CEILING LINE CEILING LINE <br />CEILING LINE CEILING LINE — — — — — — — — — — — — — <br />SOUND ATTENUATION SOUND ATTENUATION 5/8"GW13 BOTH SIDES METAL STUDS, SIZE PER SCHEDULE — — — <br />BATTS (SAB) PER BATTS (SAB) PER <br />SCHEDULE. SCHEDULE. METAL STUDS, SIZE <br />E PER SCHEDULE 5/8"GWB <br />5/8" ACOUSTICALLY ENHANCED E <br />y 5/8" GWB BOTH SIDES 5/8" GWB BOTH SIDES GWB BOTH SIDES <br />(ONE SIDE CONTINUOUS FACE OF COLUMN OR <br />TO STRUCTURE) WALL (NEW OR EXIST) chapuis design group <br />METAL STUDS, SIZES PER METAL STUDS, SIZE p <br />SCHEDULE METAL STUDS, SIZES architecture a <br />PER SCHEDULE PER SCHEDULE <br />b ACOUSTICAL SEALANT <br />ACOUSTICAL SEALANT ACOUSTICAL SEALANT BOTH SIDES ACOUSTICAL SEALANT BOTH SIDES 510 VONDERBURG DR. SUITE 216 <br />BOTH SIDES BRATeD8 3-667-2FL 840 <br />11 <br />BOTH SIDES <br />l.FLOOR LINE FLOOR LINE FLOOR LINE FLOOR LINE FLOOR LINE CGDPA - FL # AA-26003049 <br />IL <br />STUD <br />FIRE -RESISTANCE <br />SOUND ATTENUATION <br />STUD <br />FIRE -RESISTANCE <br />SOUND ATTENUATION <br />STUD <br />FIRE -RESISTANCE <br />SOUND ATTENUATION <br />STUD <br />FIRE -RESISTANCE <br />SOUND ATTENUATION <br />STUD <br />FIRE -RESISTANCE <br />SOUND ATTENUATION <br />MARK <br />SIZE <br />FIRE RATING <br />TEST <br />SAB <br />STC <br />TEST <br />MARK <br />SIZE <br />FIRE RATING <br />TEST <br />SAB STC TEST <br />MARK <br />SIZE <br />FIRE RATING <br />TEST <br />SAB STC TEST <br />MARK <br />SIZE <br />FIRE RATING <br />TEST <br />SAB <br />STC <br />TEST <br />MARK <br />SIZE <br />FIRE RATING <br />TEST <br />SAB <br />STC <br />TEST <br />A <br />3 5/8" <br />31 /2" <br />57 <br />RAL TL06-334 <br />U <br />3 5/8" <br />31 /2" <br />55 <br />TL-06-336 <br />R2 <br />21 /2" <br />- <br />- <br />U6 <br />6" <br />- <br />31/2" <br />55 <br />TL-06-336 <br />• <br />NON -FIRE <br />RATED WALL <br />NON -FIRE <br />A <br />RATED WALL, <br />SMOKE TIGHT <br />B <br />1-HOUR WALL <br />n <br />HIGH <br />STC <br />NON -FIRE <br />RATED WALL <br />STUD <br />FURRING <br />®� <br />�0 <br />sex <br />NTS <br />NTS <br />NTS <br />NTS <br />NTS <br />' SPRAY -APPLIED <br />• • - • •4 . '.` ..... - s •_ ' ••.: ;. „ ' ° • : " ° " '' ::.. - - . , .-. . � - ' � • ... ;: -•; ( •. ; . ;,_ • : -• ..; e - :•.. FIRE -RESISTIVE •,w, a a <br />d d " . • . • ' MATERIAL <br />(BERM) <br />a,:° ••'A ,e, (� _ �,. �', I I I I EXISTING METAL <br />REMOVE EXISTING STUDS IN EXISTING PROJECT FOR <br />°�° GWB SOUND AND _ ;z . I I I I ! I I I I METAL STUDS ABOVE SMOKE TIGHT <br />D o CUT ONE LAYER GWB TO o SMOKE CLOSURE <br />c I I I I J L— J L_ HEADER. NOTED THIS IS NOT A <br />FOLLOW PROFILE OF DECKING. STRIP SECURE TO o I i I I NOTE: THIS IS TO A D V E N T H EA LT H- <br />BECOME A 1-HOUR FIRE RATED WALL <br />o 2"x20 GA FIRE RATED WALL P H Y R <br />SEAL CONTINUOUSLY WITH o STRUCTURE AND SEAL -1 'o o I I I M — — — — Tj I I I c7 ,«: ';. , ` ; ° Z E H i L LS <br />WITH ACOUSTICAL STRAPS @ 16" z�: - tl NEW GYPSUM TO BE <br />ACOUSTICAL SEALANT. 20 GA Z-BARS <br />ACOUSTICAL SEALANT SEALANT O.C. TO `' <br />ACOUSTICAL SEALANT a "t '-I'I <br />BOTH SIDES ACCOMMODATE I I I I ( a _ [' 4;r INSTALLED OVER EXISTING <br />SLOTTED TOP _ FILL FLUTE VOID W/ ', ( SFRM i, ; •, �• _ JAMB STUD <br />REMOVE EXISTING HEADER ; <br />TRACK SAB SLOTTED TOP ACOUSTICAL I I I (� I I I r z METAL STUD TRACK <br />I I I I TRACK I SEALANT (BOTH w �' ,r TAPE AND MUD NEW <br />STUD I I I I !. � LI I REMOVE EXISTING JAMB GYPSUM INTEGRAL WITH <br />STUD SIDES) I ¢ ;��•� :y <br />i I I I (I I STUDS "' '_y'_: `'' %'•: EXISTING GYPSUM FOR A <br />— SAB I SMOKE TIGHT ASSEMBLY, <br />SAB I I I i I t '• TYP. ALL EDGES P C U REFRESH <br />GWB GWB I I I I I( I NEW INTERIOR 3 518" <br />22GAGE, METAL <br />:..:;' ;.: _ STUDS, MAX. 16" O.C. <br />CONCRETE SLAB METAL DECK METAL DECK STEEL BEAM I • . --;�:�`�, ,:.. - •, . <br />(PERPENDICULAR TO FLUTES) (PARALLEL TO FLUTES) I I I I I <br />` .•� �- ^ :�"'F 5/8" GYPSUM, BOTH <br />1 1 I I 111 III .t• ` • '`' -" Y, ,4 <br />SIDES OF ASSEMBLY <br />DETAIL B1 -"SMOKE PARTITIONS AND SOUND -CONTROL WALLS"- ADDITIONAL NOTES: <br />1. UPGRADE TO DETAIL"Al" WHERE WALL IS DESIGNATED WITH A FIRE -RESISTANCE RATING. <br />SEAL GYPSUM TO FLOOR, <br />2. FILL VOIDS WITH SOUND ATTENUATION BATTS (SAB). <br />TYP. BOTH SIDES TO INHIBIT <br />3. SOUND WALLS AND SMOKE PARTITIONS REQUIRE THAT AT LEAST ONE LAYER OF GWB BE CUT TO FOLLOW UNDULATING SURFACES OF SUPERSTRUCTURES I : ;"; :,, =; j.�:; ': - I' •,:;?. ��,`;;;:n :` PASSAGE OF SMOKE <br />INCLUDING BUT NOT LIMITED TO FLUTES METAL DECKING. JOINT GWB TO SUPERSTRUCTURE WITH A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. I I I I I ` ' `} METAL STUD TRACK 7050 Gall Blvd. <br />4. BUILDING CODE REQUIRES THAT "SMOKE PARTITIONS" BE SEALED TO STRUCTURE AS INDICATED TO SUCCESSFULLY "....LIMIT THE PASSAGE OF SMOKE....". - — — •',,• Zephyrh i I Is, FL 33541 <br />D1 HEAD -OF -WALL CONDITIONS - STUD WALLS - SMOKE PARTITIONS AND SOUND CONTROL WALLS D5 D�T�lFILL -EXISTING -RATED WALL -DEMO D6 DOOR INFILL - UNRATED WALL <br />3" = 1'-0" 1/21/2" =1'-0" <br />CONT TREATED WOOD <br />BLOCKING: 2x6 FOR CLOSE OPEN <br />p5 CASEWORK, PER DETAIL HVAC WITH 6 MIL. STRUCTURAL DECK <br />FOR EQUIPMENT POLY AND SEAL I I I I I EXISTING METAL <br />Q,� O WITH DUCT TAPE I I I I I( " I I I GYPSUM ASSEMBLY. <br />STUDS IN EXISTING <br />.100 AdventHealth <br />_ NOTE: THIS IS TO C <br />L—___--_— CEILING LINE I I I I I' I I I I I BECOME A l-HOUR <br />10-24 x 1 1/2" WOOD SHIM TO MATCH LEAD THICKNESS <br />FIRE RATED WALL <br />SCREWS (6 PER PIECE Z <br />OF BLOCKING) <br />CONNECTOR PLATE (OVERLAP TYPE 1 BACKING PLATE TREATED WOOD I I a �j:'�•_,;=�: '•'•!"'� <br />BLOCKING - CUT 3 5/8 NON -LOAD TAPE AND MUD NEW <br />AT CONTINUOUS BACKING SHALL BE USED FOR ANCHORAGE OF METAL STUDS AT BEARING WALL I' a, ::,Y-`,: GYPSUM INTEGRAL WITH AHCA CLIENT CODE I FILE NUMBER: NIA <br />RUNS) THE FOLLOWING: 16 OC MAX TO FIT METAL STUD FRAMING SYSTEM <br />CAI ' : {=•, ~ • ' j I I I EXISTING GYPSUM FORA 1- <br />x HOUR FIRE RATED <br />k GAS CYLINDER BRACKETSASSEMBLY, TYP. <br />METAL STUD FRAMING AND �NKg 5/8" GWB, TYPE'X', BOTH SIDES i I I I LLI p. )' y ? I •, I I EDGES SIM U465 <br />SPACING PER PARTITION <br />k TYPE • uRINALs ISOMETRIC VIEW PLAN VIEW <br />• DRESSING BENCH NEW INTERIOR 3 5/8", <br />_�t •�=`r• I <br />• GRAB BARS FILL WALL <br />• HANDRAILS ISOMETRIC &TYPICAL WALL BACKING TT INS LATH I I I I ;: _ I 22 GAGE, METAL <br />S' R19 3'�2" BAIT INSULATION ;r, i _ ='r "• STUDS, MAX. 16" O.C. <br />I I I :'`t,:'` ' `v'�'.' I FLOOR TO DECK. <br />• ADJUSTABLE WALL HUNG COUNTER C2 3/4" = 11-0" <br />., h UNINTERRUPTED <br />FIRE RATED HEAVY DUTY I I I I I " <br />FLEXIBLE WOOD BACKING PLATE <br />CONSTRUCTION OCCUPIED I I I I I � `' I�t �'" - � - F., I 5/8 GYPSUM, BOTH <br />SYSTEM SIDES OF ASSEMBLY <br />SIDE SIDE <br />SEAL GYPSUM TO FLOOR, <br />ULTIMATE LOADS ON BACKING r <br />CONTINUOUS SEALANT I I I I I - i' `' -' "•` I TYP. BOTH SIDES TO INHIBIT <br />STUD SPACING I _ '. �',_ <br />VERTICAL LATERAL I" _ -�,=';�'~; PASSAGE OF SMOKE <br />TYPE 1 BOTH SIDES METAL STUD TRACK <br />16" O.C. 800 LBS 500 LBS FLOOR LINE <br />24" O.C. 725 LBS 425 LBS DOOR I N F i L L -RATED WALL MARK DATE DESCRIPTION <br />SECTION ' USE DUCT TAPE TO SEAL ALL PIPE AND DUCT C6 1/2" =1'-0" <br />RATING INFORMATION PENETRATIONS OF PARTITION & POLY BARRIER. PROJECT NUMBER 042-22-236.01 <br />I� TYPE 2 BACKING PLATE FIRE RATING -1 HOUR ' SEAL ALL JOINTS WITH PLASTER TAPE SECURED BY <br />RAM -TACK, HIGH TACK SPRAY OR EQUIVALENT. ORIGINAL ISSUE AUGUST 26, 2022 - <br />II THREE #10 LOW PROFILE STC RATING - 45-49 <br />PAN HEAD SMS AT EACH SHALL BE USED FOR ANCHORAGE OF BASED ON UL-465 • FINISH OCCUPIED WALL SIDE WITH GLOSS PAINT. PROJECT MANAGER TEC <br />STUD, TYP. THE FOLLOWING: PROJECT DESIGNER TEC <br />x ° BASE CABINETS PARTITION TYPE - TEMPORARY 1 HOUR FIRE)PROJECT ARCHITECT THOMASE.CHAPUIS-AR97109 <br />II II I it k B5 B LANDSCAPE ARCHITECT WA <br />METAL STUD FRAMING AND FULL HEIGHT CABINETS 1 1 /2" =1'-0" CIVIL ENGINEER NIA <br />B II II II SPACING PER PARTITION <br />II II k I I� TYPE WALL MOUNTED CABINETS <br />II II k ( I • GUARDRAILS <br />II II II DOUBLE STUD FRAMING WHEN TOILET PARTITIONS <br />LOADING QccuRs ON BOTH STRUCTURAL ENGINEER NIA <br />II II (I SIDES AND EXCEED ALLOWABLE TOILET COUNTERTOPS <br />LOAD SHOWN BELOW MECHANICAL ENGINEER TIMOTHY P. PENNOCK - PE5451 <br />it II ELECTRICAL PANELS A ELECTRICAL ENGINEER CHARLES T. ALWNDER - PE76422 <br />16 GA. X 6" RUNNER TRACK • HEADWALLS <br />II II X 1.1/4" LEG NOTCHED AROUND A INTERIOR DESIGNER CDG <br />11 STUDS, EXTEND TO (1) STUD UPPER WALL -HUNG SYSTEM WALL STUDS <br />II ' BEYOND EQUIP. ATTACHMENT PT. FURNITURE I I EQUIPMENT PLANNER WA <br />SYSINETS <br />TEM FURNITURE "PANEL" THAT IS WALL STUDS <br />BACKING PLATE BOTH SIDES REQUIRED TO BE MOUNTED TO A O —O — b — O— O I I DRAWN BY SDL <br />W.O. WALL — — — <br />CABLE TRAY <br />ADDITIONAL <br />ALLOWABLE LOADS ON BACKING CABLES PIPE INSULATION STUDS INSTALLED <br />PIPE / CONDUIT HORIZONTALLY SEE <br />SYSTEM, <br />BACKING TO FORMA � I SEE VOL 3 OF THE <br />TYPE 2 VERTICAL LATERAL / — PIPE / CONDUIT — NON-METALLIC PENETRANT RECTANGULAR I PROJECT MAUNAL <br />6" X 16 GA. TRACK 220 LBS 200 LBS A A A b — d BOX — -a o <br />FOR ADDITIONAL <br />FIRESTOP SYSTEM, INFORMATION <br />I I I I SEE VOL 3 OF THE 11 11 q 1j <br />PROJECT MAUNAL TYPE 3 BACKING PLATE I I I FOR ADDITIONALtz <br />SHALL BE USED FOR ANCHORAGE OF <br />INFORMATION <br />/ TWO #8 LOW PROFILE PAN THE FOLLOWING: <br />/ HEAD SMS AT EACH STUD, — - — <br />I k TYP. • TOILET AND BATH ACCESSORIES d Z <br />N N ~ <br />TELEPHONES - LA A <br />CL <br />r A <br />METAL STUD FRAMING AND BULLETIN BOARDS <br />k I SPACING PER METAL STUD <br />PARTITIONTYPE • MIRRORS <br />x I SECTION A -A SECTION A -A SECTION A -A <br />8"-16" X 18 GA. MIN. HIGH • EXAM LIGHTS NOTE: NOTE: NOTE: <br />METAL DIRECTORIES 1. FOR FIRE RATING OF 1,2,3 & 4 HOURS 1. FOR FIRE RATING OF 1 & 2 HOURS 1. FOR FIRE RATING OF 1 & 2 HOURS GENERAL PARTITION <br />PLATE, EXTEND TO (1) STUD <br />BEYOND EQUIPMENT • CHART RACKS 2. REFER TO FULL SYSTEM DESCRIPTION W-L-1001 2. REFER TO FULL SYSTEM DESCRIPTION W-L-1147 2. REFER TO FULL SYSTEM DESCRIPTION W-L-5001 <br />�i ATTACHMENT POINT • LIQUID CHALK BOARDS <br />PARTIAL SYSTEM DESCRIPTION: PARTIAL SYSTEM DESCRIPTION: PARTIAL SYSTEM DESCRIPTION: TYPES DETAILS AND <br />"' • LITERATURE RACKS A. STEEL PIPE: NOM. 24" DIA. OR SMALLER SCHED 10 OR A.STEEL PIPE: NOM. 12" DIA. OR SMALLER SCHED 10 OR A.STEEL PIPE: NOM. 12" DIA. OR SMALLER SCHED 10 OR 7 <br />w BACKING PLATE BOTH SIDES MAGAZINE R'� HEAVIER HEAVIER HEAVIER NOTES <br />A W.O. • SIGNAGE B.IRON PIPE: 24" DIA OR SMALLER SERVICE WEIGHT OR B.1RON PIPE: 12" DIA OR SMALLER SERVICE WEIGHT OR B.COPPER TUBING: NOM. 6" DIAM OR SMALLER TYPE L OR A <br />t • SUPPORT FOR MEMBRANE HEAVIER CAST IRON PIPE, NOM. 12 " DIA OR HEAVIER CAST IRON PIPE, NOM. 12 " DIA OR HEAVIER COPPER TUBING <br />SHOWER SMALLER CLASS 50 OR HEAVIER DUCTIILE IRON SMALLER CLASS 50 OR HEAVIER DUCTIILE IRON C. COPPER PIPE: NOM. 6" DIA OR SMALLER REGULAR OR <br />t PAN LINER PRESSURE PIPE PRESSURE PIPE HEAVIER COPPER PIPE <br />C.CONDUIT: NOM. 6" DIA. OR SMALLER STEEL CONDUIT C.CONDUIT: NOM. 4" DIA. OR SMALLER STEEL CONDUIT A <br />ALLOWABLE LOADS ON BACKING OR NOM. 4" DIAM OR SMALLER STEEL ELECTRICAL OR NOM. 4" DIAM OR SMALLER STEEL ELECTRICAL UL SYSTEM NO. W-L-0020 OR SIMILAR <br />N METAL TUBING METAL TUBING <br />N BACKING D.COPPER TUBING: NOM. 6" DIAM OR SMALLER TYPE L OR D.COPPER TUBING: NOM. 4" DIAM OR SMALLER TYPE L OR FOR DAMAGE IN FIRE RATED ASSEMBLIES. <br />TYPE 3 VERTICAL LATERAL HEAVIER COPPER TUBING HEAVIER COPPER TUBING SCALE As indicated <br />49 PREVIOUS BLOW OUT PATCH DETAIL IS NO <br />8"-16" X 18 GA. PLATE 15 LBS 5 LBS E. COPPER PIPE: NOM. 6" DIA OR SMALLER REGULAR OR E. COPPER PIPE: NOM. 4" DIA OR SMALLER REGULAR OR UL SYSTEM NO. W-L 8073 OR SIMILAR LONGER AN ACCEPTABLE SOLUTION TO <br />HEAVIER COPPER PIPE HEAVIER COPPER PIPE REPAIRING HOLES/DAMAGE IN FIRE RATED <br />F. OTHERS* AS DESCRIBED IN FULL SYSTEM DESCRIPTION FOR MULTIPLE PIPE PENETRATION ASSEMBLIES <br />M BACKING PLATER SYSTEM W-L-1001 SYSTEM W-L-1147 SYSTEM W-L-5001 SYSTEM W-L-8073 SYSTEM W-L-0020 G=010Al <br />3 � 3" =1'-0" <br />A2 11/2" = V-0" A3 11/2" = V-0" A4 1 1/2" = V-0" A5 1" = V-0" A6 1,� = 1'-0" <br />v 59 1 2 3 4 5 6 <br />Project Status <br />