a I _l __ II! _ 1I ___. _ I _:l_ I I 1 L I I <br />GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2014 FLORIDA BUILDING CODE <br />5TH ADDITION AND THE 2014 FLORIDA BUILDING CODE - RESIDENTIAL 5TH ADDITION. <br />T.L. HANSON A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING <br />COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />FLOORS: GARAGE SLAB: <br />LIVE LOAD - 40 P.S.F. LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. DEAD LOAD - 10 P.S.F. <br />ROOF! <br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.B.F. <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED) <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31: PER 2014 FLORIDA <br />BUILDING CODE, RESIDENTIAL - SECTION R301.2.1.1. AND 2014 FLORIDA BUILDING CODE <br />SECTION 1609,1J. <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - 11 <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 4 EXPOSURE ADJUSTMENT <br />COEFFICIENT - 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT : +/- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602.5 <br />SOIL BEARING 4 COMPACTION: <br />COMPONENT 4 CLADDING WIND LOADS <br />ALL OTHER <br />BUILDING <br />ROOF OVERHANG <br />COMPONENT <br />ZONE <br />LOADS <br />LOADS <br />I <br />N/A <br />+32.3/-35.3 <br />2 <br />-65.1 <br />+32.3/-56.2 <br />3 <br />-110.6 <br />+32.3/-89.0 <br />4 <br />N/A <br />+35.3/-38.2 <br />5 <br />N/A <br />+35.3/-41.2 <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED 4 COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />T.L. HANSON: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />T.L. 14AN50N SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS 4 SLAB —ON —GRADE - <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL. <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR 06 REBAR 4 35" FOR 01 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER <br />FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />MASONRY WALLS: <br />CONCRETE MASONR'TUNl`b SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C- h:v <br />AND SHALL HAVE A MINIMUM F'M OF 1,500 P.S.I. <br />MORTAR SHALL CONFORM TO ASTM C-210 AND SHALL BE EITHER TYPE M OR S. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615, LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR "6 REBAR 4 35" FOR 01 REBAR. <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF 3/8", PLACED AT AN 8 TO Il INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH <br />OF 2,500 P.S.I. (WHEN TESTED PER ASTM C-1019). <br />PROVIDE CLEAN -OUT OPENINGS (12 50. IN.) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. <br />TIMBER MATERIALS: <br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />DRAFT5TOPPING- <br />IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN <br />FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING <br />SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY IS BROKEN UP INTO TWO OR <br />MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SQ. FT. <br />DRILL I" X 6" HOLE INTO EXISTING BOND BEAM <br />AND EPDXY *S REBAR FROM NEW BOND I! <br />INTO EXISTING BOND BEAM. <br />DRILL i"X6" HOLE INTO EXISTING WALLS S <br />AND EPDXY N5 REBAR FROM NEW BLOC( <br />INTO EXISTING BLOCK WALL. REBAR TO 1 <br />LONG WITH 6" INTO EXISTING WALL 6" IN I <br />BLOCK WALL <br />DRILL I" X 6" HOLE INTO EXISTING FOOTI? <br />AND EPDXY 05 REBAR FROM NEW FOOTINGS <br />INTO EXISTING FOOTINGS <br />NEW BLOCK WALL TO EXISTING WALL DETAIL <br />NOT TO SCALE <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING i COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE i DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS (PER FBC R318), <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />TRUSSES: <br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T. L. HANSON 4 ASSOCIATES IS <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT. <br />EXTERIOR WINDOWS 4 DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/152 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY, <br />ALL MULLIONS AND ADJACENT DOORAUINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1,5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW 4 DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED, <br />ELECTRICAL, PLUMBING 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411.003(2XU OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN 6 FEET OF SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT, <br />ALL ElFCTRICAL OUTLETS II I BEDROOMS SHALL BE WIR=D INTO AN ARC -FAULT INTERRUPTER <br />"AFI' CIRCUIT. <br />SAFETY GLAZING - <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 80. FT. <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR, <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. <br />ATTACH MINIMUM 3/4" P.T, BUCK <br />STRIP THAT IS THE MINIMUM WIDTH <br />OF DOOR FRAME USING .091XI 3/8" <br />T- NAILS MAXIMUM 10" OC. <br />CAULK DOOR FRAME <br />MANUFACTURES RECO <br />5' 10" <br />, 2" <br />24 SH 24 SH I <br />SECURING PREHUNG TO BUCK STRIPS <br />PER YOUR MANUFACTURES INSTRUCTIONS <br />TO MEET WIND LOADS AND COMPRESSIONS <br />RATINGS FOR YOUR JOB LOCATION. ALL <br />ANCHOR SCREWS MUST PENETRATE BLOCK <br />WALL A MINIMUM OF 1 1/4" AND THERE SHALL <br />BE A MAXIMUM 1/4" SPACE BETWEEN BUCK <br />AND DOOR JAMB <br />BLOCK DOOR ATTACHMENT DETAIL <br />NOT TO SCALE <br />ATTACH MINIMUM 3/4" P,T. BUCK STRIP <br />THAT IS THE MINIMUM WIDTH OF YOUR <br />WINDOW FRAME USING .OS-1 X 1 3/8" <br />T- NAILS MAXIMUM 10" OC <br />CAULKED WINDOW PEF <br />WINDOW MANUFACTURE <br />RECOMMENDATIONS T <br />LOAD AND COMPRES <br />FOR YOUR JOB LOCA <br />SECURING WINDOW TO BUCK STRIPS PER <br />YOUR MANUFACTURES INSTRUCTION TO MEET <br />WIND LOAD AND COMPRESSION RATINGS FOR <br />YOUR JOB LOCATION. ALL ANCHOR SCREWS <br />MUST PENETRATE BLOCK WALL A MINIMUM OF <br />1 114" AND THERE SHALL BE A MAXIMUM 1/4" <br />G AND WINDOW FRAME <br />BLOCK WINDOW ATTACHMENT DETAIL <br />NOT TO SCALE <br />18' 0" 1- 22' 10" <br />PROPOSED PARTIAL <br />II I II • <br />FOUNDATION FLAN 1/4 = 1 O <br />I <br />LINTELS ON THIS PROJECT ARE AS SPECIFIED ON THIS <br />CHART UNLESS NOTED ON FLOOR PLAN BY OPENING <br />LINTEL LOAD CHART l 1611 DEEP SECTION <br />CLEAR SPAN <br />CONCRETE U LINTEL <br />"POWER" STEEL <br />"POWER" STEEL <br />BOX LINTEL <br />4981 PLF ( UNFILLED ) <br />1010 PLF L-2 <br />9865 PLF <br />2' - 2" <br />3435 PLF ( UNFILLED ) <br />6626 PLF L-2 <br />6830 PLF <br />2' - 8" <br />7M PLF ( UNFILLED) <br />5296 PLF L-2 <br />554E PLF <br />3' - 2" <br />2332 PLF ( UNFILLED) <br />4508 PLF L-2 <br />4613 PLF <br />4'-0" <br />1835 PLF ( UNFILLED) <br />3535 PLF L-2 <br />3699 PLF <br />4' - 6" <br />1624 PLF ( UNFILLED) <br />3154 PLF L-2 <br />3288 PLF <br />5' - 2" <br />213S PLF « <br />2146 PLF L-2 « <br />2864 PLF » <br />6' - 2" <br />2211 PLF « <br />2299 PLF L-2 « <br />2400 PLF « <br />1' - O" <br />1981 PLF » <br />2025 PLF L-2 » <br />2114 PLF » <br />8' - O" <br />1123 PLF « <br />1168 PLF L-2 « <br />2213 PLF « <br />9' - 2" <br />1489 PLF « <br />1545 PLF L-2 « <br />1984 PLF « <br />10' - O" <br />1354 PLF « <br />1414 PLF L-2 « <br />ISIS PLF « <br />10' - 8" <br />1211 PLF « <br />1325 PLF L-2 » <br />1110 PLF » <br />IV- 2" <br />1200 PLF « <br />1230 PLF L-2 « <br />162S PLF « <br />12' - 0" <br />1109 PLF « <br />1118 PLF L-2 » <br />1515 PLF « <br />12' - 8" <br />1044 PLF « <br />1116 PLF L-2 « <br />1436 PLF « <br />13' - 4" <br />1398 PLF « P <br />1381 PLF L-2 « SL - 1 <br />1364 PLF » <br />14' - 0" <br />1321 PLF « P <br />1321 PLF L-2 « SL - I <br />1299 PLF •• <br />I&' - 0" <br />1152 PLF •• P <br />1048 PLF L-2 « SL - I <br />1131 PLF « <br />IW - O" <br />1016 PLF « P <br />828 PLF L-2 •• SL - 1 <br />960 PLF « <br />9T1 PLF » P <br />TTO PLF L-2 » SL - I <br />893 PLF » <br />20' - 0" <br />916 PLF » P <br />62S PLF L-2 •• SL - 1 <br />184 PLF « <br />22' - 8" <br />18S PLF » P <br />523 PLF L-2 » SL - 1 <br />606 PLF •• <br />« - DENOTES •5 REBAR X CONT. PLACED IN BOTTOM COURSE AND <br />I6" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE. <br />« P - DENOTES PRE STRESSED U LINTEL WITH 05 REBAR X CONT. <br />PLACED IN BOTTOM COURSE 4 16" DEEP BEAM POURED SOLID <br />WITH 2500 1*81 CONCRETE <br />8" X 8" X 16" KNOCK OUT BLOCK <br />TOP COARSE WITH 1 05 HORIZONTAL <br />all REBAR TIED TO ALL VERTICAL RODS <br />I� J <br />✓/f/� 8" X 8" X 16" KNOCK OUT BLOCK <br />• OVER POWER STEEL LINTELS, WITH <br />I EACH 45 REBAR IN THIS COARSE <br />WHEN SPAN OF LINTEL 18 OVER 124" <br />POWER STEEL LINTEL DETAIL <br />8" X 8" X 16" KNOCK OUT BLOCK <br />TOP COARSE WITH 1 05 HORIZONTAL <br />BII REBAR TIED TO ALL VERTICAL RODS <br />`O• 8" PRECAST LINTEL BLOCK <br />OVER ALL OPENINGS. I EACH <br />0. "5 REBAR IN THIS COARSE WHEN <br />SPAN OF LINTEL OVER 5'2" <br />STANDARD PRECAST DETAIL <br />T.L.;HANSON P.E. LICENIAl'ii 38654 <br />BOX 1128, DADE CIjY*Ft-33526 <br />099K (DPI <br />ZZ <br />I HERBY CNrj.TI THAT THESE PV• qq ND SPECIFICATIONS <br />WERE PREP, fs, ji1 Y DIRECT SUPERVISION <br />ARE IN COMPL-4 TN' ,� I6, SECTION 1609 OF THE <br />FLORIDA BUILD[[ E12 ij�`+ 1 ADDITION AND ASCE 1-10 <br />FOR 139 MPH WIND �! >k?I8'K CATEGORY II AND THE ENTIRE <br />2014 BUILDING CODE RESIDENTIAL 5TH ADDITION <br />U <br />04 <br />U) <br />Z UZr <br />z <br />W <br />co <br />"' <br />Q O <br />Q 10-.4 <br />N <br />ul �_ <br />�co <br />L9 <br />>M <br />z <br />M <br />G7 m <br />U <br />Z <br />< <br />UJI <br />0 <br />O <br />W <br />A 0(Lm <br />� O <br />N <br />U <br />} � <br />ry <br />Zm <br />N <br />Q <br />O co <br />oU)O <br />W <br />N <br />CM <br />Q <br />m <br />tQ <br />N <br />Q Xm m <br />U ct) a <br />Z LU �o <br />cA <br />vi LU <br />z z <br />z <br />o� <br />l� <br />U Z z <br />Q <br />(� <br />0 <br />of <br />lW <br />F <br />O� <br />"" U uzj <br />s <br />N <br />- <br />N <br />Q <br />z <br />IJJ <br />3 <br />m <br />4 <br />Q <br />z <br />Q <br />Q <br />i% <br />O <br />U- JU <br />Z U <br />O Lu <br />i•.i <br />cl <br />A U.l <br />cl <br />VI <br />O <br />O <br />c�n <br />Y• <br />n� <br />M.. <br />ADDITION <br />LIVING 288 <br />FIG <br />2OF4 <br />