Laserfiche WebLink
4 <br />3 <br />2 <br />J <br />Q <br />GENERAL NOTES <br />1. ALL WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ALL CODES HAVING JURISDICTION. <br />2. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE BUILDING MANAGEMENT'S RULES AND <br />REGULATIONS. <br />3. MODIFICATIONS TO THE BASE BUILDING STRUCTURE, CORE AREAS, AND UTILITY SYSTEMS ARE NOT IN THIS <br />CONTRACT, EXCEPT AS NOTED ON THESE DRAWINGS OR AS REQUIRED TO COMPLETE THE WORK INDICATED ON <br />THESE DRAWINGS. <br />4. THE G C. SHALL MAKE ALL ARRANGEMENTS AND PAY FOR ALL FEES AND PERMITS REQUIRED, AS WELL AS ANY <br />ADDITIONALCHARGES FOR HAULING, RIGGING, AND TRANSPORTATION CHARGES. <br />5. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT BETWEEN T-MOBILE AND G.0 (HEREINAFTER REFERRED <br />TO AS THE AGREEMENT) WITH CONDITIONS OF THE CONTRACT (GENERAL, SUPPLEMENTARY, AND OTHER CONDITIONS), <br />DRAWINGS, SPECIFICATIONS, ADDENDA ISSUED PRIOR TO THE EXECUTION OF THE AGREEMENT, OTHER DOCUMENTS <br />LISTED IN THE AGREEMENT, AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE AGREEMENT <br />6. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION <br />AND COMPLETION OF THE WORK BY THE CONTRACTORS. PERFORMANCE BY THE G.C. SHALL BE REQUIRED ONLY TO <br />EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING <br />NECESSARY TO PRODUCE THE INTENDED RESULTS, <br />7. THE CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND (1 <br />BETWEEN THE ARCHITECT AND G.C., (2) BETWEEN T-MOBILE AND A SUBCONTRACTOR OR SUB -SUBCONTRACTOR, OR <br />(3) BETWEEN ANY PERSONS OR ENTITIES OTHER THAN T-MOBILE AND G.C. <br />8. EXECUTION OF THE CONTRACT BY G.C. IS A REPRESENTATION THAT THE G.C. HAS VISITED THE SITE AND HAS <br />BECOME FAMILIAR WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE <br />CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING WORK AND SHALL NOTIFY ARCHITECT <br />AND/OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS THE CONTRACTOR FROM ACCOMPLISHING THE <br />INTENT OF DRAWINGS. <br />9. THE TERM "WORK" MEANS THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS, WHETHER <br />COMPLETED OR PARTIALLY COMPLETED, INCLUDES ALL LABOR, MATERIALS, EQUIPMENT, AND SERVICES PROVIDED <br />(OR TO BE PROVIDED) BY THE G.C. TO FULFILL THE G.0 'S OBLIGATIONS. THE WORK MAY CONSTITUTE <br />THE WHOLE OR PART OF THE PROJECT. <br />10. G.C. SHALL NOT CUT OR DISTURB EXISTING STRUCTURAL SYSTEM. THE G.C. SHALL X-RAY/PACHOMETER SLAB TO <br />DETERMINE IF POST TENSIONED SLAB OR IF DESIGN IS IN CONFLICT WITH EXISTING STRUCTURAL SYSTEMS WHEN THE <br />FOLLOWING OCCURS: <br />10.1. TENANT SPACE IS LOCATED ON SECOND FLOOR OR ABOVE <br />10.2. LOWER LEVEL EXTENDS BELOW THE TENANT SPACE <br />10.3. ABSENCE OF STRUCTURAL DRAWINGS FROM ARCHITECTS AND/OR LANDLORD <br />10.4. ABSENCE OF STRUCTURAL DRAWINGS INCLUDED WITH CONTRACT DOCUMENTS <br />11 _ G C- SHALL ONLY INCLUDE AN ALLOWANCE IN HIS BID FOR THE X-RAY/PACHOMETER WHEN ANY OR ALL OF THE ABOVE <br />OCCUR,TYP. <br />12. PROVIDE CONTROL KEY AND MASTER KEY AS REQUIRED BY CONTRACT. PERFORM ALL REQUIRED CLEANINGS AS PER <br />CONTRACT INCLUDING, BUT NOT LIMITED TO, ALL STOREFRONT WINDOWS, MULLIONS, CEILINGS, SUPPLY/RETURN AIR <br />GRILLS, FLOORING AND FLOOR WAX, TOILET ROOMS, TOILET ROOM CAULKING, AND WALK -OFF MAT REMOVE ALL <br />TRASH AND DEBRIS FROM THE SITE. <br />13. ALL REFERENCES HEREAFTER TO CONSTRUCTION PM OR ARCHITECT REFER TO THE CONTACT LISTED <br />IN PROJECT TEAM. <br />14. PROVIDE OCCUPANCY SIGNS CONFORMING TO APPLICABLE BUILDING CODE REQUIREMENTS. <br />15. PROVIDE ADDITIONAL EXIT SIGNS AND FIRE EXTINGUISHERS IN TYPE, NUMBER, AND LOCATION AS DIRECTED BY THE <br />FIRE DEPARTMENT FIELD INSPECTOR. <br />ABBREVIATIONS <br />ACP. <br />ACOUSTICAL CEILING <br />J.H.A <br />JURISDICTION HAVING AUTHORITY <br />ADJ. <br />ADJACENT <br />LAM. <br />LAMINATE <br />AL -ALUM <br />ALUMINUM <br />LAV. <br />LAVATORY <br />ALT- <br />ALTERNATE <br />ILL. <br />LANDLORD <br />A.P. <br />ACCESS PANEL <br />LT, <br />LIGHT <br />APPX <br />APPROXIMATE <br />L V.T <br />LUXURY VINYL TILE <br />ARCH, <br />ARCHITECTURAL <br />MAX. <br />MAXIMUM <br />BD, <br />BOARD <br />MECH. <br />MECHANICAL <br />BLDG. <br />BUILDING <br />MTL. <br />METAL <br />BILK. <br />BLOCK <br />MGR. <br />MANAGER <br />BLKG. <br />BLOCKING <br />MFR. <br />MANUFACTURER <br />BM. <br />BEAM <br />MIN. <br />MINIMUM <br />BOT, <br />BOTTOM <br />MIR. <br />MIRROR <br />CAB, <br />CABINET <br />MISC, <br />MISCELLANEOUS <br />CEM. <br />CEMENT <br />MTD. <br />MOUNTED <br />CKT. <br />CIRCUIT <br />MTG. <br />MOUNTING <br />CLG. <br />CEILING <br />N.I.C. <br />NOT IN CONTRACT <br />CLR. <br />CLEAR <br />NOM. <br />NOMINAL <br />CMU. <br />CONCRETE MASONRY UNIT <br />N.T.S. <br />NOT TO SCALE <br />COL, <br />COLUMN <br />O.C. <br />ON CENTER <br />CONC. <br />CONCRETE <br />O.D. <br />OUTSIDE DIAMETER <br />CONST. <br />CONSTRUCTION <br />OPP <br />OPPOSITE <br />CONT. <br />CONTINUOUS <br />PLYWD, <br />PLYWOOD <br />CPT. <br />CARPET <br />PNL. <br />PANEL <br />CTR. <br />CENTER <br />PROP. <br />PROPERTY <br />DET. <br />DETAIL <br />P.T. <br />PRESSURE TREATED <br />DIA. <br />DIAMETER <br />PWR, <br />POWER <br />DIFF. <br />DIFFUSER <br />CITY- <br />QUANTITY <br />DIM. <br />DIMENSION <br />R. <br />RADIUS <br />DWG(S). <br />DRAWING, DRAWINGS <br />REQ. <br />REQUIRED <br />EA. <br />EACH <br />R.O. <br />ROUGH OPENING <br />E.I.F.S. <br />EXTERIOR INSULATION FINISH SYSTEM <br />S.C. <br />SOLID CORE <br />ELEC, <br />ELECTRIC, ELECTRICAL <br />SCHED. <br />SCHEDULE <br />EM <br />EMERGENCY <br />SECT. <br />SECTION <br />EQ <br />EQUAL <br />SQ.FT. <br />SQUARE FEET <br />EQUIP. <br />EQUIPMENT <br />SIM. <br />SIMILAR <br />EWC. <br />ELECTRIC WATER COOLER <br />SPEC <br />SPECIFICATION <br />EXH. <br />EXHAUST <br />SQ. <br />SQUARE <br />EXIST <br />EXISTING <br />STD. <br />STANDARD <br />EXTIR <br />EXTINGUISHER <br />STL. <br />STEEL <br />FIN <br />FINISH <br />STRUCT. <br />STRUCTURAL <br />FIXT. <br />FIXTURE <br />SYM. <br />SYMMETRICAL <br />FLR. <br />FLOOR <br />TEL. <br />TELEPHONE <br />F.R. <br />FIRE RATED/RETARDANT <br />TELCO. <br />TELE-COMMUNICATIONS <br />F.R.P. <br />FIBERGLASS REINFORCED POLYESTER PANEL <br />TMO. <br />T-MOBILE <br />F R T. <br />FIRE RETARDANT TREATED <br />TMP. <br />TYPICAL <br />GA, <br />GAUGE <br />U.O.N. <br />UNLESS OTHERWISE NOTED <br />GALV. <br />GALVANIZED <br />VCT. <br />VINYL COMPOSITION <br />GND,GRND <br />GROUND <br />W/ <br />WITH <br />GYP. <br />GYPSUM <br />WD. <br />WOOD <br />HDW. <br />HARDWARE <br />W/O <br />WITHOUT <br />H.M. <br />HOLLOW METAL <br />WP. <br />WATERPROOF <br />HR. <br />HOUR <br />W R <br />WATER RESISTANT <br />HT <br />HEIGHT <br />Wr <br />WEIGHT <br />H.V.A.0 <br />HEATING, VENTILATING, AIR CONDITIONING <br />SHEET SYMBOLS <br />SECTION INTERIOR ELEVATION INDICATOR <br />ELEVATION NUMBER X1 X1 <br />X# X### X X### <br />X### <br />SHEET NUMBER SHEET NUMBER <br />X3 <br />DETAIL <br />X# <br />X### <br />SHEET NUMBER <br />DETAIL NUMBER <br />X# <br />X### l <br />DRAWING TITLE <br />KEYED NOTES <br />ELEVATION NUMBER �X1 X1 <br />X X### X2<X### X4 <br />X3 <br />EXTERIOR ELEVATION INDICATOR <br />ELEVATION NUMBER <br />X# <br />X### <br />SHEET NUMBER <br />AREA REVISED <br />ti TITLE REVISION NUMBER <br />X# 1" = 1" (FULL) <br />DRAWING NUMBER <br />DRAWING SCALE <br />RESPONSIBILITY SCHEDULE <br />GENERAL <br />OBTAIN ALL APPLICABLE PERMITS AND CERTIFICATE OF OCCUPANCY <br />TM GC <br />TM GC <br />UTILITY FEES IF NEW CONSTRUCTION <br />N/A <br />N/A <br />UTILITY SERVICES AND METERS <br />EXISTING <br />EXISTING <br />ALL HAZARDOUS MATERIALS REPORTS IF REQUIRED <br />LANDLORD <br />LANDLORD <br />CORE SHELL AND SITE WORK <br />EXTERIOR SIGNAGE BLOCKING <br />N/A <br />N/A <br />DEMOLITION — SITE/BUILDING <br />N/A <br />N/A <br />STRUCTURE AND ROOF <br />EXISTING <br />EXISTING <br />ROOF PENETRATIONS & REPAIRS <br />TM GC <br />TM GC <br />EXTERIOR WALLS/REPAIRS <br />LANDLORD <br />LANDLORD <br />EXIT DOOR NEW OR REPAIR AS NOTED PER PLANS <br />TM GC <br />TM GC <br />TRIDENT EXIT DOOR LOCK GC to purchase direct from T-Mobile Vendor -Cushman &Wakefield <br />TM GC <br />TM DIRECT <br />TELEPHONE SERVICE ESTABLISHED BETWEEN THE STREET & DEMARC <br />EXISTING <br />EXISTING <br />PLUMBING MAIN SERVICE <br />EXISTING <br />EXISTING <br />SPRINKLER MAINS - if applicable <br />EXISTING <br />EXISTING <br />FIRE ALARM PANEL - if applicable <br />EXISTING <br />EXISTING <br />CONCRETE SLAB <br />EXISTING <br />EXISTING <br />EXTERIOR STOREFRONT SYSTEM AND GLAZING - if applicable <br />TM GC <br />TM GC <br />WINDOW SECURITY FILM - if applicable <br />TM DIRECT <br />TM DIRECT <br />DEMISING WALL STUDS <br />EXISTING <br />EXISTING <br />DEMISING WALL SECURITY MESH <br />TM GC <br />TM GC <br />DEMISING WALL / GYP/ INSULATION/FIRE CAULKING <br />EXISTING <br />EXISTING <br />DEMISING WALL / PATCH & REPAIR AS REQUIRED <br />TM GC <br />TM GC <br />SITE ACCESSIBILITY & SIDEWALKS <br />LANDLORD <br />LANDLORD <br />PARKING LOT PAVING AND STRIPING <br />LANDLORD <br />LANDLORD <br />INTERIOR MALLS <br />BARRICADES - if applicable <br />TM GC <br />TM GC <br />BARRICADE GRAPHICS - if applicable <br />TM DIRECT <br />TM DIRECT <br />MALL TILE AROUND STOREFRONT - if applicable <br />TM GC <br />TM GC <br />NEUTRAL PIERS NEW or REPAIR EXISTING PER PLAN - if applicable <br />ITM GC <br />TM GC <br />REVEALS - if applicable <br />TM GC <br />TM GC <br />MALL STOREFRONT SYSTEMS INCLUDES GLAZING & FINISHES - if applicable <br />TM GC <br />TM GC <br />INTERIOR TENANT BUILD -OUT <br />DEMOLITION — INTERIOR <br />TM GC <br />TM GC <br />WALL PARTITION SALES AREA TO BOH WITH DOOR & HDW <br />TM GC <br />TM GC <br />TRILOGY LOCK ON BOH PARTITION (GC to purchase direct from T-Mobile Vendor - Cushman & <br />Wakefield) <br />TM GC <br />TM DIRECT <br />INVENTORY ROOM WALLS/CEILINGS INCLUDES: MESH CEMENT BOARD AND DOOR/HDW <br />TM GC <br />TM GC <br />POLICE LOCK AND LEVER SET ON INVENTORY ROOM DOOR (GC to purchase direct from T- <br />Mobile Vendor - Cushman & Wakefield) <br />TM GC <br />TM DIRECT <br />TRAINING ROOM OFFICE CONFERENCE ROOM -if applicable <br />TM GC <br />TM GC <br />ALL ADDITIONAL WALL PARTITIONS <br />TM GC <br />TM GC <br />MISC. WOOD BLOCKING FURRING ETC. <br />TM GC <br />TM GC <br />GYPSUM BOARD CURTAINS WALLS CEILINGS SOFFITS ACCESS PANELS <br />TM GC <br />TM GC <br />ACOUSTICAL CEILING TILE & GRID <br />TM GC <br />TM GC <br />ELECTRICAL TRANSFORMERS IF REQUIRED <br />TM GC <br />TM GC <br />ELECTRICAL SYSTEM - MAIN PANEL <br />TM GC <br />TM GC <br />ELECTRICAL SYSTEM - SUB PANELS <br />TM GC <br />TM GC <br />LIGHTING SYSTEM - SALES AREA <br />TM DIRECT <br />TM GC <br />LIGHTING SYSTEM - BACK OF HOUSE <br />TM DIRECT <br />TM GC <br />ELECTRICAL WIRING. OUTLETS <br />TM GC <br />TM GC <br />ELECTRICAL CONNECTIONS TO T-MOBILE SUPPLIED FIXTURES <br />TM GC <br />TM GC <br />LIGHTING INVERTER LCP TVSS SWITCHES SENSORS DIMMERS <br />TM DIRECT <br />TM GC <br />ENERGY MANAGEMENT SYSTEM AND SENSORS IF REQUIRED <br />TM GC <br />TM GC <br />LOW VOLTAGE CONDUIT <br />TM GC <br />TM GC <br />LOW VOLTAGE WIRING <br />TM DIRECT <br />TM DIRECT <br />TELCO BACKER BOARD <br />TM GC <br />TM GC <br />SECURITY SHUTTER - if applicable <br />TM DIRECT <br />TM DIRECT <br />SECURITY SHUTTER BLOCKING - if applicable <br />TM GC <br />TM GC <br />HVAC SYSTEM - DISTRIBUTION CONDENSATE PAN/DRAINS T-STATS ECONOMISERS <br />TM GC <br />TM GC <br />HVAC SYSTEM - UNIT/CURBS/DROPS <br />TM GC <br />TM GC <br />FIRE ALARM DEVICES/CONNECTION TO PANEL - if applicable <br />TM GC <br />TM GC <br />PLUMBING BRANCH LINES NEW AND\OR MODIFICATIONS <br />TM GC <br />TM GC <br />SPRINKLER BRANCH LINES AND HEADS - if applicable <br />TM GC <br />TM GC <br />HOT WATER HEATER <br />TM GC <br />TM GC <br />FLOOR PREPARATION & TRANSITIONS <br />TM GC <br />TM GC <br />FLOORING/WALK OFF MATS SALES FLOOR <br />TM DIRECT <br />TM GC <br />FLOORING BACK OF HOUSE <br />TM GC <br />TM GC <br />PAINTING <br />TM GC <br />TM GC <br />FIRE EXTINGUISHERS <br />TM GC <br />ITM GC <br />INTERIOR SIGNAGE AS REQ'D PER CODE <br />TM GC <br />TM GC <br />BACK OF HOU E ITEMS <br />KITCHENETTE CASEWORK & WALL SHELVING <br />TM GC <br />TM GC <br />KITCHENETTE SINK AND FAUCET <br />TM GC <br />TM GC <br />MOP/UTILITY SINK <br />TM GC <br />TM GC <br />SHELVING: INVENTORY ROOM WIRE SHELVES WALL MOUNTED ABOVE DESK <br />TM GC <br />TM GC <br />PEG BOARD <br />TM GC <br />TM GC <br />INSTA-KEY LOCK CORES, KEYS (GC to purchase direct from T-Mobile Vendor - Cushman & <br />Wakefield) <br />TM GC <br />TM DIRECT <br />TOILET ROOM -DRINKING FOUNTAINS <br />TOILETS URINALS LAVATORIES <br />TM GC <br />TM GC <br />HIGH LOW DRINKING FOUNTAINS <br />TM GC <br />TM GC <br />PLUMBING FIXTURES <br />TM GC <br />TM GC <br />WALL PARTITIONS & CEILINGS <br />TM GC <br />TM GC <br />FINISHES: SHEET VINYL WITH INTEGRATED BASE FRP PAINT <br />TM GC <br />TM GC <br />AUTOMATIC HAND DRYER & FAN/LIGHT COMBO <br />TM DIRECT <br />TM GC <br />COAT HOOK/GRAB BARS/MIRROR/TP DISPENSERS/LOCKING CABINET <br />ITM GC <br />ITM GC <br />WASTE RECEPTACLE TOILET SEAT COVER DISP OFFICE DEPOT <br />TM DIRECT <br />TM GC <br />OWNER SUPPLIED <br />SIGNAGE: BUILDING MOUNUMENT PYLON WINDOW GRAPHICS ETC. <br />TM DIRECT <br />TM DIRECT <br />LOSS PREVENTION SYSTEM BURGLAR <br />TM DIRECT <br />TM DIRECT <br />SHOPPER TRAK & MUSIC SYSTEM <br />TM DIRECT <br />TM DIRECT <br />FIXTURES MERCHANDISING HARDWARE TABLES CHAIRS & STOOLS <br />TM DIRECT <br />TM DIRECT <br />HAND SET SECURITY-IN-VUE <br />TM DIRECT <br />TM DIRECT <br />STAPLES DESK CHAIRS TABLES FILE CABS WHITE BOARD APPLIANCES <br />TM DIRECT <br />TM GC <br />LOW VOLTAGE WIRING <br />TM DIRECT <br />TM DIRECT <br />NETWORK & COMPUTER INSTALLATION <br />TM DIRECT <br />TM DIRECT <br />M R OFFICErrRAINING ROOM FURNITURE & EQUIP T- if amplicable <br />ITM GC <br />ITM GO <br />CODE ANALYSIS <br />PROJECT DESCRIPTION <br />TENANTIMPROVEMENT <br />MOBILE PHONE & SERVICE SALES (RETAIL) <br />REFER TO EGRESS PLAN ON G101 <br />PROJECT LOCATION <br />GALL BLVD & MEDICAL CENTER AVE 2 <br />7248 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33541 <br />GOVERNING CODES <br />ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, ANY STATE AND LOCAL CODES HAVING <br />JURISDICTION AS WELL AS THE REQUIREMENTS OF THE FOLLOWING: <br />BUILDING <br />2020 <br />FLORIDA BUILDING CODE 7TH. EDITION <br />MECHANICAL <br />2020 <br />FLORIDA MECHANICAL CODE 7TH. EDITION <br />PLUMBING <br />2020 <br />FLORIDA PLUMBING CODE 7TH. EDITION <br />ELECTRICAL <br />2020 <br />NATIONAL ELECTRIC CODE <br />ENERGY <br />2020 <br />FLORIDA ENERGY CONSERVATION CODE 7TH. <br />EDITION <br />ACCESSIBILITY <br />2020 <br />FLORIDA ACCESSIBILITY CODE 7TH. EDITION <br />FUEL GAS <br />20201 <br />FLORIDA FUEL GAS CODE 7TH. EDITION <br />FIRE <br />20201 <br />FLORIDA FIRE CODE 7TH. EDITION <br />PROJECT INFORMATION <br />CONSTRUCTION TYPE <br />II-B <br />FULLY SPRINKLERED <br />NO <br />OCCUPANCY GROUP <br />M - MERCANTILE <br />GROSS LEASED PREMISES <br />2,396 SQ. FT <br />OCCUPANTLOAD <br />ROOM NAME <br />SQ. FT. <br />LOAD FACTOR <br />OCCUPANT LOAD <br />SALES AREA <br />1528 <br />T <br />60 <br />26 <br />BACK OF HOUSE <br />868 <br />T <br />300 <br />3 <br />OFFICE <br />0 <br />- <br />100 <br />0 <br />TRAINING ROOM <br />0 <br />+ <br />100 <br />0 <br />TOTAL NUMBER OF OCCUPANTS <br />29 <br />EXIT REQUIREMENTS <br />TWO EXITS REQUIRED WHEN OCCUPANT LOAD IS GREATER THAN 49 OR COMMON PATH OF TRAVEL EXCEEDS <br />75FT <br />REQUIRED <br />PROVIDED <br />TOTAL NUMBER OF EXITS <br />2 <br />2 <br />FOR EXIT PATH OF TRAVEL SEE EGRESS PLAN ON SHEET G101 <br />PLUMBING FIXTURE REQUIREMENTS <br />MIN. # OF FIXTURES <br />29 <br />T 2 = <br />15 M <br />15 W <br />FIXTURE <br />LOAD FACTOR <br />REQUIRED <br />PROVIDED <br />WATER CLOSET <br />15/500 M <br />15/500 W <br />1 <br />1 <br />LAVATORY <br />15/750 M <br />15/750 W <br />1 <br />1 <br />SEPARATE FACILITIES <br />- <br />- <br />NO <br />NO <br />DRINKING FOUNTAIN <br />29/1000 <br />1 <br />1 <br />SERVICE SINK <br />- <br />- <br />1 <br />1 <br />SEPARATE FACILITIES SHALL NOT BE REQUIRED IN MERCANTILE OCCUPANCIES IN WHICH THE MAXIMUM <br />OCCUPANT LOAD IS 100 OR LESS <br />EXIT ILLUMINATION <br />EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED AS SHOWN ON SHEET E111. <br />MUNICIPAL REVIEW <br />CITY OF ZEPHYRHILLS <br />BUILDING DEPARTMENT <br />5335 8TH. STREET <br />ZEPHYRHILLS, FL 33542 <br />(813) 780-0020 <br />WORK BY OTHERS UNDER SEPARATE PERMIT <br />ALL REQUIRED PERMITS AND APPROVALS MUST BE OBTAINED FROM THE FIRE DEPARTMENT BEFORE SPACE IS <br />OCCUPIED. <br />DRAWING INDEX <br />ARCHITECTURAL <br />0000 <br />COVER SHEET <br />G001 <br />ARCHITECTURAL DATA SHEET <br />G002 <br />ACCESSIBILITY DETAILS <br />G101 <br />KEY PLAN, VICINITY MAP, AND EGRESS PLAN <br />G111 <br />SITE PLAN (FOR REFERENCE ONLY) <br />A101 <br />EXISTING CONDITIONS AND DEMOLITION PLAN <br />A102 <br />SAW CUTTING DEMOLITION PLAN <br />A111 <br />CONSTRUCTION FLOOR PLAN <br />A121 <br />FINISH FLOOR PLAN <br />A131 <br />REFLECTED CEILING PLAN <br />A141 <br />FIXTURE FLOOR PLAN <br />A201 <br />SALES FLOOR INTERIOR ELEVATIONS <br />A202 <br />BACK OF HOUSE INTERIOR ELEVATIONS <br />A401 <br />ENLARGED TOILET ROOM <br />A501 <br />PARTITION DETAILS <br />A511 <br />DOOR DETAILS <br />A521 <br />FIXTURE BLOCKING DETAILS <br />A531 <br />KITCHENETTE, MOP SINK AND MANAGERS DESK DETAILS <br />A541 <br />CEILING DETAILS <br />A561 <br />FLOORING AND BASE DETAILS <br />A601 <br />FINISH SCHEDULE <br />A611 <br />DOOR SCHEDULE <br />A621 <br />FIXTURE, FURNITURE, EQUIPMENT AND GRAPHIC SCHEDULES <br />A701 - A706 <br />SPECIFICATIONS <br />MECHANICAL <br />M101 <br />MECHANICAL FLOOR PLAN <br />ELECTRICAL <br />E101 <br />POWER FLOOR PLAN <br />E111 <br />LIGHTING FLOOR PLAN <br />E112 <br />LUMINAIRE SCHEDULES <br />E113 <br />LIGHTING CONTROLS <br />E114 <br />ENTOUCH LIGHTING CONTROLS <br />E115 <br />ENTOUCH LIGHTING CONTROLS <br />E301 <br />ELECTRICAL PANELS <br />E502 <br />FIXTURE FEED WIRING DETAILS <br />E601 <br />LIGHTING ENERGY CALCULATIONS <br />E602 <br />LIGHTING ENERGY CALCULATIONS <br />E701 <br />ELECTRICAL SPECIFICATIONS <br />PLUMBING <br />P101 <br />PLUMBING FLOOR PLAN <br />P501 <br />PLUMBING DETAILS <br />CLIENT <br />T-MOBILE <br />12920 SE 38TH <br />STREET <br />BELLEVUE, WA 98006 <br />www.t-mobile.com <br />CONSTRUCTION <br />CONSTRUCTION PM <br />KIM YANEZ <br />484-639-3309 <br />kim.yanez2@t-mobile.com <br />PROJECT TEAM <br />ARCHITECTURE <br />FUZION ARCHITECTURAL DESIGN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />WILLIAM PALUCH <br />(808) 797-4068 <br />william@fuzionve.com <br />www.fuzionve.com <br />ELECTRICAL <br />ERIC M. AIELLI, PE <br />435 SCHENCK AVE <br />OAKWOOD, OH 45409 <br />(937) 486-4233 <br />eric@phase3eng.com <br />LANDLORD <br />COLIN MOHAMED <br />212-709-8120 <br />colin.mohamed@cpa.com <br />MECHANICAL & PLUMBING <br />DENNIS J. LEWIS, PE <br />2010 KITTY HAWK DRVIE <br />XENIA, OH 45385 <br />(937) 219-9498 <br />T Mobile <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE: <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORM UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION <br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT IN CESSATION OF CONSTRUCTION. BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT. <br />ruzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />VWWV.FUZIONVE.COM <br />VENDOR PROJECT NO: 21.11.212680 <br />0 FC <br />LOUIS <br />oo <br />RFD A� <br />02/10/2022 <br />CONSULTING ENGINEER. <br />N <br />W <br />LU <br />IRT <br />r LO <br />W > M <br />C� J J <br />J = LL- <br />Q <br />V m J <br />J <br />o JUj <br />- <br />2 <br />V = <br />00 <br />0. <br />� N W <br />mti N <br />J <br />J <br />,Q <br />V <br />## DESCRIPTION DATE <br />DATE: February 5, 2022 <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />ARCHITECTURAL <br />DATA SHEET <br />4 <br />3 <br />2 <br />f <br />SHEET NUMBER: <br />G001 <br />