Laserfiche WebLink
4 I 3 <br />--- I _.I--L-'- -—L---__ L---__--_---- -- .I -- --_ - — 1-1--A- <br />2 <br />1 <br />l T I , I 1 , . u <br />ml <br />, , <br />., , <br />, <br />CIF E E D <br />DOOR <br />FRAME <br />DETAILS <br />DOOR # <br />DESCRIPTION <br />1 <br />FIRE RATING <br />HARDWARE <br />FURNISHED BY <br />INSTALLED BY <br />NOTES <br />SIZE <br />TYPE <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />SILL <br />JAMB <br />HEAD <br />1 <br />(E) EXTERIOR ENTRY <br />T-0" X T-0" X 1 3/4" V.I.F. <br />B <br />ALUMINUM / GLASS <br />MFR <br />ALUMINUM <br />FMR <br />A1/A561 <br />_ <br />_ <br />Al, A2, A3, A4,A5, Cl, G3, <br />(E) <br />(E) <br />1, 2, 3, 4, 5, 6, 29, 30, 31 <br />2 <br />(E) EXTERIOR ENTRY <br />T-0" X T-0" X 1 3/4" V.I.F. <br />B <br />ALUMINUM / GLASS <br />MFR <br />ALUMINUM <br />FMR <br />A1/A561 <br />_ <br />_ <br />- <br />Al, A2, A3, A4, A5, Cl, G3, <br />(E) <br />(E) <br />1, 2, 3, 4, 5, 6, 29, 30, 31 <br />L1 <br />3 <br />(E) REAR/SERVICE <br />T-0" X T-0" X 1 3/4" V.I.F. <br />A <br />INSULATED METAL <br />P105 / MFR <br />HOLLOW METAL <br />P105 / MFR <br />- <br />- <br />- <br />- <br />A6, C2, El, H1 <br />(E) <br />(E) <br />5, 6, 7, 8, 8, 10, 31 <br />HOLLOW METAL <br />4 <br />BACK OF HOUSE <br />T-0" X T-0" X 1 3/4" <br />A <br />HOLLOW METAL <br />P105 <br />KNOCK DOWN <br />P105 <br />62/A561 <br />A1/A511 <br />B1/A511 <br />- <br />A8, A9, C3, E3, G1, H1 <br />G.C. <br />G.C. <br />7, 21, 32 <br />5 <br />INVENTORY ROOM <br />T-0" X T-0" X 1 3/4" <br />A <br />HOLLOW METAL 16 GAUGE <br />MFR <br />HOLLOW <br />KNOCK DOWN <br />MFR <br />- <br />A2/A511 <br />B2/A511 <br />- <br />A8, A9, C3, E2, G 1, H 1, H2, <br />G.C. <br />G.C. <br />10, 15, 16, 17, 18, 19 <br />L5 <br />6 <br />TOILET ROOM <br />T-0" X T-0" X 1 3/4" <br />A <br />HOLLOW METAL <br />P105IP106 <br />HOLLOW METAL <br />KNOCK DOWN <br />P105/P106 <br />- <br />A1/A511 <br />B1/A511 <br />- <br />A8, A9, C3, G2, H1, L6 <br />G.C. <br />G.C. <br />7, 20, 32 <br />7 <br />SECURITY SHUTTERS <br />V.I.F. <br />D <br />CLEAR ANODIZED <br />- <br />- <br />- <br />- <br />- <br />- <br />L2, L3 <br />G.C. <br />G.C. <br />11, 12, 13 <br />u <br />, <br />., <br />D !� ;� L t�El� <br />, <br />s <br />i <br />ACCESSORIES <br />CLOSERS <br />SPECIALTY HARDWARE <br />GASKETS <br />HINGES <br />LOCKSET <br />Al <br />PUSH/PULL BARS - ROCKWOOD BF 15847-1 <br />A9 <br />IVES 10 X 34 8400 KICK PLATE <br />Cl <br />LCN 6030 <br />E1 <br />SECURITECH TRIDENT, TEL-210S <br />G1 <br />IVES FS436 DOORSTOP <br />H1 <br />MCKINNEY TA2714 NRP 4.5 X 4.5 HINGE <br />L1 <br />INSTA-KEY MORTISE HOUSING WITH I/C CORE 7-PIN <br />A2 <br />INTERMEDIATE PIVOT - RIXSON #M19 - OFFSET <br />A10 <br />IVES #20 SILENCERS <br />C2 <br />LCN 5010 <br />E2 <br />SECURITECH 4850-MP POLICE LOCK, 4851-TT-BG-37 <br />G2 <br />IVES WS406 CCV DOORSTOP <br />H2 <br />HAGER 253** 4 1/2" WIDE PIVOT HINGE <br />L2 <br />QMI CYLINDER SILVER SHUTTER CURTAIN - LOCK OUTSIDE, INSTA KEY <br />CYLINDER -LOCK <br />A3 <br />TOP PIVOT - RIXSON #180 - OFFSET <br />All <br />TOP PIVOT - RIXSON 340 <br />C3 <br />LCN 4000 SERIES <br />E3 <br />TRILOGY KEYPAD ACCESS CONTROL LOCK <br />G3 <br />DOOR SWEEP <br />H3 <br />HAGER BB1191 NRP HINGE <br />L3 <br />QMI CYLINDER SILVER SHUTTER CURTAIN - LOCK INSIDE -OUTSIDE, <br />DL27001C/26D <br />INSTA KEY CYLINDER -LOCK <br />A4 <br />BOTTOM PIVOT - RIXSON #147 - OFFSET <br />Al2 <br />CENTER HUNG PIVOT SET - RIXSON 370 <br />C4 <br />E4 <br />DETEX ALARM CRASH BAR, V40xEB, EXIT ONLY <br />G4 <br />H4 <br />BOTTOM PIVOT - RIXSON #147 - OFFSET <br />L4 <br />ARROW MLX01 SERIES PASSAGE LEVERSET <br />GLASS STOREFRONT DOORS <br />A5 <br />NATIONAL GUARD US32D, US28, US15 FINISH <br />A13 <br />IVES U696 PEEP HOLE <br />C5 <br />E5 <br />DETEX EAX-500, AUDIBLE ALARM USED IF CRASH <br />G5 <br />H5 <br />L5 <br />ARROW MLX82-SB26D306R21C I/C STOREROOM LEVERSET <br />THRESHOLD <br />BAR IS NOT AN OPTION. <br />GIRL BRUSHED STAINLESS 48" EXTRA LENGTH <br />RR ACCESS NTR L: TRILOGY - DL27001 /26D, & <br />A6 <br />NATIONAL GUARD MILL FINISH THRESHOLD <br />A14 <br />LADDER STYLE BACK-TO-BACK PULL <br />C6 <br />E6 <br />SCHLAGE DOORBOLT OCCUPENCY INDICATOR B571- <br />G6 <br />H6 <br />L6 <br />ARROW MLX72 SERIES PRIVACY LEVERSET <br />626 <br />A7 <br />NATIONAL GUARD CRL8010ADJ THRESHOLD <br />C7 <br />E7 <br />G7 <br />H7 <br />L7 <br />ARROW MLX87-SB26D I/C CLASSROOM <br />A8 <br />IVES SR-64 SILENCERS <br />C8 <br />E8 <br />G8 <br />H8 <br />L8 <br />.................... .. . <br />N�NrN NNrNrWN N <br />w�wrBwr��wwrrwwrr���wirwpwNr�nrrrrr��r�r��rr�rNr���� wwwr�wNrw.�.a-� <br />Nrrw�rrimp. - rrrwrTitl�iill <br />rpr�rr�rwrw�irirrirNrwww�iww <br />wrBN rrBrrrrN.NNN.NNrwrNr <br />III NwNiir N�IwNwrww Nww r <br />wwrwrlrwwNN��nrwr r <br />wwrrwrrrNNrr rr <br />....NN. ■Nw wN■r w. rN.Nr <br />r: :ri�■■■I■Ii�IN�QBI � .��� <br />iPii�i wrww rrrr�rio <br />ririirirwo r�iiiiNrrwNr �Ia�ilri <br />wrwlrrwNwwrwNwwNNrrr <br />N011 Lim, <br />�,D <br />1. SIGNAGE BY G.C.; PROVIDE SIGNAGE ABOVE DOOR(S), SEE SHEET G002 <br />2. POSTAL ADDRESS NUMBERS PER LANDLORD REQUIREMENTS. <br />3. ADA PANIC HARDWARE TO BE INSTALLED ON INSIDE WHEN REQUIRED BY LOCAL JURISDICTION. <br />4. LOCKS SHALL BE KEY -OPERATED WITH INDICATOR TO BE READILY DISTINGUISHABLE AS LOCKED. <br />5. WEATHER STRIPPING AND SWEEPS TO BE INSTALLED AS REQUIRED. <br />6. EXISTING DOOR - VERIFY EXISTING HARDWARE MEETS REQUIREMENTS OF, OR IS EQUAL TO SPECIFIED <br />HARDWARE. REPLACE WITH SPECIFIED HARDWARE AS REQUIRED. <br />7. KICK PLATE TO BE PROVIDED ON PUSH SIDE. IF NOT, PROVIDE AND INSTALL NEW KICK PLATE ON PUSH <br />SIDE OF DOOR: IVES 8400 10"X2" LDW630. <br />8. VERIFY ALL EXISTING DOOR HARDWARE TO COMPLY WITH CURRENT CODE. <br />9. HARDWARE PURCHASED AND INSTALLED BY G.C., DOOR PREP BY G.C.. <br />10. PROVIDE NON REMOVABLE PINS (NRP), PIANO TYPE HINGE OR GEARED HINGE (ROTON) AS APPROVED <br />BY T-MOBILE ON IN -SWINGING DOOR. <br />11. ROLL DOWN SHUTTER SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR SPECIAL <br />KNOWLEDGE OR EFFORT WHILE THE SPACE IS OCCUPIED. <br />12. SHUTTER SHALL REMAIN SECURED IN THE FULL OPEN POSITION DURING THE PERIOD OF OCCUPANCY <br />BY THE GENERAL PUBLIC. <br />13. MAX SHUTTER SIZE: 160 SF OR 150" HIGH. <br />14. PROVIDE RISER AS REQUIRED FOR CARPET INSTALLATION. <br />15. PROVIDE LATCH GUARD USE "BG" GUARD PLATE. <br />16. PROVIDE 5 1/2" THROAT. <br />17. VERTICALLY STIFFED HOLLOW METAL DOOR RECOMMENDED FOR SECURITY AND EASE OF <br />INSTALLATION. <br />18. LOCK HARDWARE PURCHASED AND INSTALLED BY G.C. THROUGH APPROVED VENDOR, SECURITY <br />SOURCE. <br />19. MOUNT AT UPPER CORNER OF DOOR AND JAMB. <br />20. PROVIDE APPROPRIATE RESTROOM SIGNAGE, SEE SHEET G002 & A401. <br />21. LOCK HARDWARE PURCHASED AND INSTALLED BY SECURITY SOURCE (VENDOR), DOOR PREP BY G.C.. <br />22. ORDER 6" BOTTOM BAR WITH 60° BEVEL (ALTERNATE OPTION: 10" BOTTOM BAR), 7-PIN KEYED <br />CYLINDERS (CONSTRUCTION CORES) WITH THUMBTURNS ON INSIDE, AND PATCH HINGES WITH DOOR. <br />23. PROVIDE LOUVRE VENT IN DOOR U.O.N. SEE MECHANICAL SHEETS. <br />24. G.C. TO PAINT 4 INCH "NO STORAGE" ON DOOR . <br />25. PROVIDE IC-7PIN MORTISE HOUSING AND INSTAKEY CORE. <br />26. TAMPER -PROOF PEEP HOLE AS REQUIRED - WIDE ANGLE SET AT 60" A.F.F. UL LISTED FOR 90 MINUTE <br />FIRE DOOR. NO PEEP HOLES ON EXTERIOR DOORS. <br />27. SELF -LATCHING LOCK HARDWARE PURCHASED AND INSTALLED THROUGH SECURITY SOURCE <br />(VENDOR) BY G.C.. DOOR PREP BY G.C.. <br />28, SUPPLY COMPLETE EXIT DEVICE PART NUMBER BASED ON DOOR SIZE AS REQUIRED. 36" DOOR = 36, <br />NARROW STILE = NS, DOUBLE DOOR = 94. FOR NARROW STILE, ADD NARROW STILE KIT #101879-1. <br />29. BOTTOM RAIL TO BE 10" MINIMUM. <br />30. PROVIDE ADDITIONAL INTERMEDIATE PIVOT FOR DOORS 8'-0" AND TALLER. <br />31. DO NOT PROVIDE HOLD OPEN DEVICE ON DOOR IF TACTILE SIGNAGE IS MOUNTED TO DOOR. <br />32. PAINT DOOR AND FRAME P101 ON SALES AREA SIDE ONLY <br />C E I `L T S� <br />A. HARDWARE FINISHES SHALL BE SATIN CHROME 626 UNLESS NOTED OTHERWISE. <br />B. ALL LOCKSETS AND LATCH SETS SHALL BE LEVER HANDLES <br />C. VERIFY ALL EXISTING DOOR HARDWARE TO COMPLY WITH CURRENT CODE. SHALL NOT REQUIRE <br />TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. VERIFY EXISTING DOOR <br />HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ARE INSTALLED BETWEEN 34" - <br />48" AFF, <br />D. G.C. TO PURCHASE AND INSTALL CORES PER HARDWARE SCHEDULE FROM T-MOBILE'S VENDOR AT <br />TIME OF STORE TURNOVER. <br />E. AT EXISTING DOORS TO REMAIN, VERIFY THAT EXISTING DOOR AND HARDWARE MEETS OR EXCEEDS <br />THE REQUIREMENTS OF THESE SPECIFICATIONS. REPLACE AS REQUIRED. <br />F. DOORS WITH CLOSERS SHALL COMPLY WITH THE FOLLOWING: <br />1. 5LBF MAXIMUM FORCE FOR OPENING DOOR <br />2. FROM AN OPEN POSITION OF 70°, DOOR SHALL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 <br />INCHES FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. <br />G. DOORS/FRAMES SHALL BE'TIMELY" (OR EQUAL) FACTORY FINISH TO MATCH P101. <br />H. LEVER SETS TO BE FALCON GRADE 1 WITH INTERCHANGEABLE CORES. T-SERIES OR APPROVED <br />EQUAL LEVER TO BE AVALON STYLE. <br />I. SECURITECH TRIDENT EXIT DEVICES SUPPLIED BY LP NETWORK INC., DBA SECURITY SOURCE (888) <br />836-2137 <br />J. EXIT DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE, WITHOUT THE USE OF A KEY OR <br />SPECIAL KNOWLEDGE OR EFFORT. THE UNLATCHING OF ANY EXIT DOOR SHALL NOT REQUIRE MORE <br />THAN ONE OPERATION. INSTALL ALL PANIC HARDWARE PER PLANS. <br />Mobi"le <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE: <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION <br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN, UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT: <br />rmUzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />WWW.FUZIONVE.COM <br />VENDOR PROJECT NO. 21.11.212680 <br />rv <br />LOUsg <br />�0 . <br />I ti, <br />I �• <br />sr'�REu AR��� <br />02/10/2022 <br />CONSULTING ENGINEER: <br />N <br />W <br />LLJ <br />Lo <br />Z � M <br />W <br />J = LL <br />V 0 J co <br />0 J J <br />� J � <br />a <br />pGo <br />d.a <br />> N W <br />mtiN <br />J <br />a <br />0 <br />DATE: February 5, 2022 <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />DOOR SCHEDULE <br />SHEET NUMBER: <br />A A� DOOR -TYPES <br />4 I 3 2 I 1 <br />