<br />EXTERIOR
<br />69' 11" LEASE LINE V.I.F.
<br />e
<br />j ADJACENT TENANT
<br />EXISTING CONDITIONS AND DEMOLITION PLAN
<br />1 /4" = 1'-0"
<br />1 E ED OTES
<br />O
<br />NOTES
<br />1
<br />EXISTING STOREFRONT SYSTEM, GLAZING, AND DOOR(S) TO REMAIN.
<br />2
<br />EXISTING DEMISING WALL TO REMAIN. PATCH AND REPAIR AS REQUIRED.
<br />3
<br />EXISTING STRUCTURAL COLUMN TO REMAIN. REMOVE ALL EXISTING FINISHES AND PREPARE FOR NEW FINISH AS INDICATED IN THESE PLANS.
<br />4
<br />EXISTING FLOOR FINISHES TO BE REMOVED DOWN TO SLAB. PREPARE EXISTING CONCRETE FLOOR SURFACE FOR INSTALLATION OF NEW FLOORING MATERIALS AS INDICATED
<br />IN THESE PLANS. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. (TYPICAL THROUGHOUT LEASED SPACE)
<br />5
<br />EXISTING SERVICE DOOR TO REMAIN. SEE DOOR SCHEDULE FOR NEW HARDWARE.
<br />6
<br />EXISTING RETAIL DISPLAY FIXTURES, FURNITURE, SIGNAGE, AND ASSOCIATED EQUIPMENT TO BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE NOTED. ANY T-MOBILE
<br />EQUPMENT DESIGNATED TO BE RETAINED FOR FUTURE USE IS TO BE DECOMMISHIONED BY OWNERS VENDOR AND STORED IN BACK OF HOUSE.
<br />LEASE LINE
<br />$
<br />EXISTING ELECTRICAL PANEL(S) TO REMAIN. SEE ELECTRICAL DRAWINGS.
<br />9
<br />EXISTING THRESHOLD TO REMAIN. REPLACE IF IT EXCEEDS 1/2" IN HEIGHT.
<br />10
<br />EXISTING INTERIOR WALL PARTITION TO BE REMOVED IN ITS ENTIRETY.
<br />11
<br />NOT USED
<br />12
<br />EXISTING INTERIOR DOOR TO BE REMOVED IN ITS ENTIRETY.
<br />13
<br />EXISTING TOILET ROOM TO BE REMOVED IN ITS ENTIRETY INCLUDING ALL WALLS, DOOR, CEILING AND PLUMBING FIXTURES. EXTEND SUPPLY AND WASTE LINES AS REQ'D TO
<br />NEW PLUMBING FIXTURES AS INDICATED IN THESE PLANS. PREPARE FOR CONSTRUCTION OF NEW TOILET ROOM. SEE A111 AND A401 FOR ENLARGED TOILET ROOM PLAN.
<br />EXISTING CEILING SYSTEM TO BE REMOVED IN ITS ENTIRETY. PREPARE FOR INSTALLATION OF NEW CEILING SYSTEM AS SHOWN ON SHEET A131. PAINT ANY EXISTING GYP
<br />SOFFIT AS NOTED ON SHEET A131. EXISTING LIGHTING, EMERGENCY LIGHTING, AND EXIT SIGNS TO BE REMOVED IN THEIR ENTIRETY. PREPARE FOR INSTALLATION OF NEW
<br />LIGHTING, EM LIGHTING, AND EXIT SIGNS AS SHOWN ON SHEET A131. EXISTING DIFUSERS TO BE REMOVED AND REPLACED WITH NEW BLACK DIFUSERS IN THE SALES AREA AND
<br />14
<br />HALLWAY/VESTIBULE. EXISTING DIFUSERS TO REMAIN AND BE RELOCATED AS REQ'D DUE TO NEW CONSTRUCTION IN ALL BACK OF HOUSE AREAS. PERFORM PRE -DEMO AND
<br />FINAL BALANCING TEST AND ADJUST ALL SYSTEM BALANCING DAMPERS AND/OR SUPPLY AIR FAN TO PROVIDE THE ORIGINAL AIR QUANTITIES AT EACH AIR DEVICE. SEE
<br />MECHANICAL DRAWINGS FOR MORE INFORMATION. IF AUXILLARY EQUIPMENT (TYCO, FIRE ALARM, SPRINKLERS, SHOPPER TRAK, ETC.) NEED TO BE REMOVED OR RELOCATED,
<br />COORDINATE WITH T-MOBILE'S VENDOR AND/OR APPROVED FIRE SPRINKLER SUB -CONTRACTOR. T-MOBILES VENDOR TO RELOCATE SECURITY CAMERAS AS NEEDED PER NEW
<br />FIXTURE LAYOUT. (TYPICAL THROUGHOUT LEASED SPACE)
<br />15
<br />1EXISTING FLOOR MOUNTED EQUIPMENT RACK TO REMAIN.
<br />ADJACENT TENANT
<br />PI
<br />1. GENERAL CONTRACTOR AND/OR SUBCONTRACTORS
<br />SHALL REVIEW THE EXISTING FACILITY TO DETERMINE
<br />THE EXTENT OF DEMOLITION REQUIRED TO INSTALL THE
<br />NEW WORK. A WRITTEN OUTLINE OF ALL REQUIRED
<br />DEMOLITION SHALL BE SUBMITTED TO T-MOBILE
<br />DESCRIBING THE FOLLOWING (BUT NOT LIMITED TO):
<br />1.1 CONDITION OF EXISTING POWER PANELS AND
<br />TRANSFORMERS; FEASIBILITY FOR RELOCATION AND
<br />REFURBISHING, OR NEED FOR REPLACEMENT DUE TO
<br />AGE OR EXISTING CONDITION.
<br />1.2 CONDITION OF EXISTING GYPSUM BOARD ON EXISTING
<br />DEMISING WALLS AND RECOMMENDATION OR WHETHER
<br />TO REMOVE EXISTING OR REUSE TO BE DETERMINED IN
<br />FIELD,
<br />1.3 SUMMARIZE RECOMMENDATIONS FOR REUSE OF
<br />EXISTING MATERIALS, EQUIPMENT, AND ACCESSORIES.
<br />ONCE REFURBISHED TO A LIKE -NEW CONDITION,
<br />ITEMIZE THE CREDIT TO THE CONTRACT.
<br />1.4 TENANT G.C. SHALL NOTIFY THE ARCHITECT OF ANY UN -
<br />NOTED EXISTING CONDITION WHICH CONFLICTS WITH
<br />THE PROJECT REQUIREMENTS AND MAY REQUIRE
<br />MODIFICATION, RELOCATION, OR REMOVAL TO COMPLETE
<br />THE PROJECT WITHIN 24 HOURS SO THAT THE
<br />NECESSARY DRAWING REVISIONS MAY BE
<br />INCORPORATED INTO THE PROJECT REQUIREMENTS.
<br />1.5 IN ADDITION TO THE ABOVE, REFER TO GENERAL
<br />DEMOLITION NOTES INDICATED IN SPECIFICATION
<br />DIVISION 2- EXISTING CONDITIONS.
<br />1.6 CONDITION OF EXISTING MECHANICAL SYSTEM;
<br />FEASIBILITY OF REUSING, RELOCATION, OR
<br />REFURBISHING EXISTING EQUIPMENT AND
<br />DUCTWORK; AND RECOMMENDATION OF
<br />REPLACEMENT, IF NECESSARY, PRIOR TO BID.
<br />SEE MECHANICAL DRAWINGS FOR SCOPE OF
<br />MECHANICAL WORK.
<br />u
<br />t
<br />n
<br />R
<br />0
<br />w
<br />z
<br />J
<br />w
<br />U)
<br />a
<br />w
<br />(V
<br />('7
<br />G ►ii
<br />N
<br />1.
<br />CHECK MECHANICAL AND ELECTRICAL DRAWINGS PRIOR RO DEMOLITION
<br />14.
<br />FIRE SPRINKLER SYSTEM TO REMAIN - G.C. TO RE -WORK/ MODIFY SYSTEM AS
<br />WITH REGARD TO UTILIZING ANY EXISTING WIRING, LINES, COMPONENTS,
<br />REQUIRED FOR NEWCONSTRUCTION. VERIFY IN FIELD.
<br />ETC.
<br />15.
<br />WHERE REQUIRED BY THE LOCAL JURISDICTION, G.C. SHALL PREPARE A
<br />2.
<br />PROVIDE TRASH CONTAINER AS REQUIRED AT LOCATION TO SUIT
<br />"RECYCLING PLAN" TO DIVERT DEBRIS FOR RECYCLING. G.C. SHALL KEEP
<br />LANDLORD. REMOVE DEBRIS DAILY AND HAUL FROM THE SITE AT TIME TO
<br />RECORDS OF DIVERTED MATERIAL AS REQUIRED. G.0 TO VERIFY
<br />SUIT LANDLORD.
<br />REQUIREMENTS WITH JURISDICTION AND TO MALL OPERATIONS/ LANDLORD
<br />3.
<br />NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCPRENANCIES OR
<br />WHERE APLLICABLE.
<br />UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS.
<br />16.
<br />REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS, AND DOOR FRAMES
<br />4.
<br />ALL REMOVED MATERIAL AND DEBRIS, NOT OTHERWISE DESIGNATED,
<br />SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. THAT
<br />BECOMES THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE IT
<br />IS ATTACHED TO PARTITIONS SCHEDULED FOR DEMOLITION.
<br />FROM THE SITE.
<br />17.
<br />REMOVE EXISTING HVAC CEILING DIFFUSERS AND RETURN GRILLES AS
<br />5.
<br />G.C. SHALL NOT DEMOLISH AND LOAD BEARING WALLS OR CONSTRUCTION
<br />SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION
<br />THAT WILL COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING
<br />AND NEW CONSTRUCTION. MODIFY EXISTING DUCTWORK AS REQUIRED BY
<br />SPACE. G.C. TO NOTIFY THE ARCHITECT IMMEDIATELY OF ANY STRUCTURAL
<br />NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF SUPPLY
<br />CONCERNS DURING CONSTRUCTION.
<br />AND RETURN DUCTS AT NEAREST SOURCE ABOVE CEILNG.
<br />6.
<br />EXISTING EQUIPMENT NOT BEING USED MUST BE COMPLETELY
<br />18.
<br />REMOVE ALL EXISTING PLUMBING FIXTURES, FITTINGS, AND PIPING AS
<br />REMOVED/DISPOSED OF PROPERLY. NOTHING CAN BE ABANDONED ABOVE
<br />SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION
<br />THE CEILING.
<br />AND NEW CONSTRUCTION, OR IF NOT REQUIRED, TERMINATE AND CAP OFF AT
<br />7.
<br />REMOVE EXISTING ACCOUSTICAL CEILING GRID AND TILES, LIGHT FIXTURES,
<br />WET STACK.
<br />AND GYPSUM WALL BOARD SOFFITS AS SCHEDULED FOR DEMOLITION AND
<br />19.
<br />REMOVAL/ RELOCATION OF ALL CEILING EQUIPMENT (TYCO, FIRE ALARM,
<br />AS REQUIRED BY PARTITION DEMOLTION AND NEW CONSTRUCTION WORK.
<br />SPRINKLER, SHOPPER TRAK, ETC.) MUST BE PERFORMED BY THE REQUIRED
<br />MAINTAIN EXISTING CEILING WIRE HANGERS FOR FUTURE USE.
<br />VENDORS. T-MOBILE'S VENDOR TO RELOCATE SECURITY CAMERAS AS NEEDED
<br />8.
<br />REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA
<br />PER NEW FIXTURE LAYOUT.
<br />JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION.
<br />20.
<br />G.C. TO CONFIRM FLOOR SLAB IS SMOOTH AND LEVEL AND NOTIFY
<br />MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT
<br />CONSTRUCTION PM OF ANY DISCREPANCIES.
<br />REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE
<br />21.
<br />MAINTAIN EXISTING EXITS, EMERGENCY LIGHTING, AND ILLUMINATION MEANS
<br />ABOVE CEILING.
<br />OF EGRESS DURING DEMOLITION AND CONSTRUCTION AS REQUIRED BY JHA
<br />9.
<br />REMOVE EXISTING FLOOR FINISHES SCHEDULED FOR REMOVAL AND AS
<br />AND ALL GOVERNING CODES.
<br />REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION. PREPARE
<br />22.
<br />SAW -CUTTING SHOWN ON PLANS IS AN INDICATION OF THE INTENDED WORK
<br />EXISTING FLOOR SURFACE PER MANUFACTURER FOR INSTALLATION OF
<br />FOR BIDDING AND COORDINATION PUPOSES ONLY. IT IS NOT INTENDED FOR BE
<br />NEW FLOORING MATERIAL INDICATED IN THESE PLANS. G.C. MAY NEED TO
<br />AS SPECIFICATION OR METHOD.
<br />PERFORM A MOISTURE TEST PRIOR TO ANY DEMOLITION OR NEW FLOORING
<br />23.
<br />WHEN EXISTING MECHANICAL SYSTEM IS TO REMAIN, G.C. TO CLEAN
<br />INSTALLATION. NEWLY REPLACED OR LIKE -NEW FINISHES MAY REMAIN AT
<br />DUCTWORK, DIFFUSERS, AND REPLACE HVAC AIR FILTERS AFTER
<br />THE DISCRETION OF THE CONSTRUCTION PM. G.C, TO VERIFY PRIOR TO
<br />CONSTRUCTION AND CLEANUP IS COMPLETE PRIOR TO TURNING PROJECT
<br />REMOVAL. PROTECT ALL NEW FLOOR FINISHES UNTIL FINAL CLEANING.
<br />OVER TO T-MOBILE.
<br />10.
<br />REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT
<br />24.
<br />DURING CONSTRUCTION, THE G.C. IS TO PROVIDE A PORTABLE FIRE
<br />DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES
<br />EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHING A 75 FOOR
<br />FOR FINISHES AS SCHEDULED OR REFINISH TO MATCH EXISTING.
<br />TRAVEL DISTANCE TO ALL PORTIONS OF THE SPACE.
<br />11.
<br />PROVIDE A SMOOTH, NEAT, AND CONTIUOUS APPEARANCE WHERE
<br />DEMOLITION WORK MEETS ADJACENT EXISTING WORK, REMOVED EXISTING
<br />FINISHES AS REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND
<br />TRANSITIONS BETWEEN EXISTING AND MATCHING NEW FINISHES.
<br />12.
<br />IN ACCORDANCE WITH LOCAL CODES, REPLACE ALL FIRE SUPPRESSION
<br />AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN
<br />INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM SYSTEMS. VERIFY IN
<br />FIELD.
<br />13.
<br />IN THE CASE THAT THE EXISTING CABLE LINE, PHONE LINE AND BLOCK, T-1
<br />LINE AND DATA CABLING PRESENT, G.C. SHALL SALVAGE AND REWORK TO
<br />FACILITATE NEW INSTALLATION.
<br />T Mobl*le@
<br />12920 SE 38th STREET
<br />BELLEVUE, WA 98006
<br />www.T-Mobile.com
<br />COPYRIGHT NOTICE
<br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO
<br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF
<br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003, THE PROTECTION
<br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND
<br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH
<br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS
<br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR
<br />MONETARY LIABILITY.
<br />ARCHITECT
<br />rmUzioN
<br />9096 EAST BAHIA DRIVE
<br />SUITE 103
<br />SCOTTSDALE, AZ 85260
<br />DESIGN@FUZIONVE.COM
<br />WWW.FUZIONVE.COM
<br />VENDOR PROJECT NO: 21.11.212680
<br />o
<br />'S' e
<br />Q 4
<br />FRED ARG�I►
<br />02/10/2022
<br />CONSULTING ENGINEER:
<br />N
<br />W
<br />a
<br />Apr
<br />W > M
<br />C� J J
<br />e.e.l = L=-
<br />a
<br />C.)m J
<br />� J
<br />� J �
<br />06 0
<br />own.
<br />.JtN�.N
<br />CO
<br />J
<br />_el
<br />a
<br />f jp0$q MPTIQIN
<br />DATE: February 5, 2022
<br />SCALE: AS NOTED
<br />DRAWN BY: LEO V.
<br />SAP NUMBER:
<br />4SIR
<br />CORPORATE TENANT REBUILD
<br />LDC
<br />SHEET TITLE:
<br />EXISTING CONDITIONS
<br />AND DEMO PLAN
<br />SHEET NUMBER:
<br />A101