Laserfiche WebLink
III <br />4 <br />3 <br />1wit laLA... — I 1 11 <br />-! _._—_�i l _=. <br />_!�1'.II I.. III,_. I, I I I II 1 II 1 1 1 1 II <br />2 <br />I I I I I <br />I II 11 II I' I <br />1 <br />U <br />co <br />PROVIDE AND INSTALL AMICO ASM .5-13F SECURITY — <br />MESH TO 12'-0" AFF ON TENANT SIDE OF DEMISING <br />WALL PRIOR TO WALL FURRING. SEE A501 FOR <br />PARTITION TYPE, CONSTRUCTION OF PARTITION, STUD <br />SIZING, AND INSULATION REQUIREMENTS. <br />EXTERIOR <br />O <br />EXISTING <br />EQUIPMENT RACK <br />16' 2" <br />INVENTORY <br />A2 <br />A511 <br />7 �C <br />C4 <br />A501 <br />BACK OF HOUSE <br />EXISTING <br />ELECTRICAL <br />PANELS 2' 0"L L13' 10" <br />Al <br />O B 1 3 X A511 TYP <br />(E) <br />o 0 <br />EN N <br />B 1113 X B 1 3 A B 1113 IX <br />WALL MOUNTED I TOILET ROOM I VESTIBULE <br />FIRE EXTINGUISHER <br />I I BI 113 JA <br />0 <br />l ooe l <br />B 4 3 X B 4 3 X <br />C2 A4 <br />A401 G002 <br />9101. 8' 0" 5' 0" <br />CONSTRUCTION FLOOR PLAN <br />v T / 1 /4" = 1'-0" <br />ADJACENT TENANT <br />PROVIDE AND INSTALL AMICO ASM .5-13F SECURITY MESH TO 12'-0" AFF ON TENANT <br />SIDE OF DEMISING WALL PRIOR TO WALL FURRING. SEE A501 FOR PARTITION TYPE, <br />CONSTRUCTION OF PARTITION, STUD SIZING, AND INSULATION REQUIREMENTS. <br />%mo_ - J �� r <br />B2 A2 <br />A521 A521 <br />I�o PROVIDE BLOCKING ON OUTSIDE OF PARTITION <br />WALL FOR NEW PRODUCT BAY FIXTURES. SEE <br />A141 FOR EXACT LOCATION OF FIXTURES. <br />62 <br />A521 <br />I <br />I B 1 1 X <br />(ALL 4 SIDES) <br />I_ EXISTING <br />COLUMN <br />I <br />I <br />I <br />(V <br />fV <br />0o 0 <br />m bD A2 <br />A521 <br />CV <br />PROVIDE AND INSTALL AMICO ASM .5-13F SECURITY MESH TO 12'-0" AFF ON TENANT <br />SIDE OF DEMISING WALL PRIOR TO WALL FURRING. SEE A501 FOR PARTITION TYPE, <br />CONSTRUCTION OF PARTITION, STUD SIZING, AND INSULATION REQUIREMENTS. <br />ADJACENT TENANT <br />SALES AREA <br />- PROVIDE BLOCKING IN WALL FURRING FOR NEW <br />FAST LANE FIXTURES. SEE A141 FOR EXACT <br />LOCATION OF FIXTURES. <br />----r W"- <br />45' 1" <br />EXISTING DOOR. <br />PATCH AND REPAIR TO <br />"AS -NEW' CONDITION <br />AS NECESSARY <br />NEW DOOR AS <br />SCHEDULED <br />LINETYPE INDICATES <br />ACCESSIBLE CLEARANCE <br />I <br />I <br />I <br />I <br />A2 I I <br />A521 i I <br />OI <br />(E) <br />I I <br />I <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OI <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />WALL MOUNTED (- <br />FIRE EXTINGUISHER <br />r- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I i <br />I I <br />OI <br />(E) <br />I I <br />DOOR NUMBER. SEE <br />D# SHEET A511 FOR <br />DETAILS AND SHEET A611 <br />FOR DOOR SCHEDULE. <br />u <br />u <br />lj <br />EXISTING STOREFRONT <br />SYSTEM AND GLAZING <br />�--- EXISTING SINGLE <br />ENTRY DOOR <br />EXTERIOR <br />EXISTING SINGLE <br />ENTRY DOOR <br />EXISTING STOREFRONT <br />SYSTEM AND GLAZING <br />NOT <br />J <br />1. G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY <br />DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. <br />2. FOR ALL PARTITION CONNECTION DETAILS (TOP AND BOTTOM) SEE SHEET A501 <br />3. ALL ANGLED WALLS ARE 45', 90°, OR 135' U.O.N. <br />4. MAINTAIN FIRE RESISTANCE RATING FOR ALL TENANT DEMISING WALLS. <br />5. PROVIDE WATER RESISTANT GYPSUM BOARD AT ALL WET LOCATIONS (UTILITY SINK, <br />KITCHENETTE, DRINKING FOUNTAIN, TOILET ROOM, ETC.) <br />6. G.C. TO COORDINATE LOCATION OF ELECTRICAL FLOOR BOXES WITH ELECTRICAL <br />DRAWINGS AND FIXTURE PLAN. <br />7. WHERE EXISTING INSULATION IS REMOVED OR MISSING, PATCH AND REPLACE INSULATION <br />TO MATCH EXISTING CONDITIONS AND MAINTAIN REQUIRED R-VALUES. <br />8. ALL DOORS TO BE LOCATED 4" FROM PERPENDICULAR WALL UNLESS OTHERWISE NOTED. <br />ALL DOORS DIMENSIONED TO ROUGH OPENING OF DOOR. <br />9. ALL DIMENSIONS ARE FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD <br />UNLESS OTHERWISE NOTED. <br />10. SLAB PENETRATIONS SHALL BE MADE WITH PROPER LOCATION AND X-RAY IDENTIFICATION <br />OF EXISTING REBAR AND/OR POST TENSION CABLES. <br />Mobl*lev <br />12920 SE 38th STREET <br />BELLEVUE, WA 98006 <br />www.T-Mobile.com <br />COPYRIGHT NOTICE: <br />THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO <br />COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF <br />THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED JANUARY 2003. THE PROTECTION <br />INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND <br />COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH <br />PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS <br />MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND/OR <br />MONETARY LIABILITY. <br />ARCHITECT <br />rmUzioN <br />9096 EAST BAHIA DRIVE <br />SUITE 103 <br />SCOTTSDALE, AZ 85260 <br />DESIGN@FUZIONVE.COM <br />VWWV.FUZIONVE.COM <br />VENDOR PROJECT NO: 21.11.212660 <br />,i ' OF F4O <br />W.MLOur,q •','� <br />STFRFD <br />02/10/2022 <br />CONSULTING ENGINEER <br />N <br />W <br />Q <br />0 r <br />W > M <br />0 JJ <br />J = LL <br />C.)Im J <br />- m � <br />G _ <br />W J = <br />00 <br />ova. <br />JtiN <br />to <br />J <br />Q <br />0. IDE$CMPTIPN <br />DATE: February 5, 2022 <br />SCALE: AS NOTED <br />DRAWN BY: LEO V. <br />SAP NUMBER: <br />4SIR <br />CORPORATE TENANT REBUILD <br />LDC <br />SHEET TITLE: <br />CONSTRUCTION FLOOR PLAN <br />SHEET NUMBER: <br />4 I 3 I 2 I 1 <br />