ll _ I _ _ I I <br />GENERAL INSPECTION REQUIREMENTS <br />REQUIRED INSPECTION <br />FREQUENCY OF <br />IBC SECTION & <br />INSPECTOR <br />VERIFICATION, OR TEST <br />INSPECTION <br />TYPE AND/OR FREQUENCY OF TESTING <br />REFERENCE <br />QUALIFICATIONS <br />CRITERIA <br />REQUIRED INSPECTIONS <br />A. FOOTING AND FOUNDATION <br />PERIODIC <br />INSPECTION OF PREPARED SUBGRADE, PLACED REINFORCING STEEL, <br />FBC 109.3.1 <br />CITY BUILDING <br />ANY REQUIRED FORMS, AND MATERIALS FOR CONCRETE FOR ON -SITE <br />OFFICIAL <br />MIXING <br />B. CONCRETE SLAB & UNDER -FLOOR <br />PERIODIC <br />INSPECTION OF IN -SLAB AND UNDER -FLOOR REINFORCING STEEL AFTER <br />FBC 109.3.2 <br />CITY BUILDING <br />BUILDING SERVICE EQUIPMENT, CONDUIT, PIPING ACCESSORIES AND <br />OFFICIAL <br />OTHER ANCILLARY EQUIPMENT ITEMS ARE IN PLACE. <br />C. LOWEST FLOOR ELEVATION <br />PERIODIC <br />VERIFY BUILDING NOT IN A FLOOD HAZARD AREA <br />FBC 109.3.3 <br />CITY BUILDING <br />OFFICIAL <br />D. OTHER INSPECTIONS <br />AS NOTED <br />AS NOTED <br />FBC 109.3.8 <br />AS NOTED <br />IBC SECTION & <br />REQUIRED INSPECTION <br />FREQUENCY OF <br />REFERENCE <br />INSPECTOR <br />VERIFICATION, OR TEST <br />INSPECTION <br />TYPE AND/OR FREQUENCY OF TESTING <br />CRITERIA <br />QUALIFICATIONS <br />CONCRETE CONSTRUCTION <br />A. REINFORCING STEEL <br />PERIODIC <br />PROVIDE PERIODIC INSPECTION OF REINFORCING SIZES, SPACING, <br />FBC 1704.4 <br />*QUALIFICATIONS <br />GRADE OF REBAR; AND PLACEMENT AT THE FOLLOWING FREQUENCY: <br />ACI 318: CH. 3.5, <br />BASED ON ASTM <br />COLUMNS: 10% <br />7.1-7.7; <br />E329 <br />BEAMS: 30% <br />CONCRETE AND <br />JOIST: 10% <br />REINFORCING <br />OTHER MEMBERS: RANDOMLY @ 20% <br />GENERAL NOTES. <br />B. REINFORCING STEEL WELDING <br />PERIODIC <br />1. VERIFICATION OF WELD ABILITY OF REINFORCING STEEL OTHER THAN <br />AWS D1.4 ACI 318: <br />CWI/ASSOCIATE/ <br />A706. <br />3 5 2 <br />TECHNICIAN <br />TRAINED IN FIELD <br />CONTINUOUS <br />2. REINFORCING STEEL -RESISTING FLEXURAL AND AXIAL FORCES IN <br />OF WORK AND HAS <br />INTERMEDIATE AND SPECIAL MOMENT FRAMES, AND BOUNDARY <br />AT LEAST ONE YEAR <br />ELEMENTS OF SPECIAL REINFORCED CONCRETE SHEAR WALLS AND <br />OF EXPERIENCE. <br />SHEAR REINFORCEMENT. <br />CONTINUOUS <br />3. SHEAR REINFORCEMENT. <br />PERIODIC <br />4. OTHER REINFORCING STEEL. <br />TECHNICIAN <br />C. BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO <br />CONTINUOUS <br />VERIFY LOCATION, SIZE AND SPACING OF ANCHORS. <br />IBC 1704.4 <br />TRAINED IN FIELD <br />& DURING PLACEMENT OF CONCRETE WHERE <br />OF WORK AND HAS <br />ALLOWABLE LOADS HAVE BEEN INCREASED. <br />AT LEAST ONE <br />YEAR EXP. <br />D. VERIFY USE OF CONCRETE MIX DESIGN <br />PERIODIC <br />EACH CONCRETE POUR. <br />ACI 318-CH. 4, <br />*QUALIFICATIONS <br />5.2-5.4 <br />BASED ON ASTM <br />C1077 <br />E. SAMPLING OF FRESH CONCRETE. <br />CONTINUOUS <br />1. ALL CONCRETE TESTING IS TO BE MADE AFTER WATER, IF ANY, IS <br />ACI 318-CH. 5.6 <br />*QUALIFICATIONS <br />EACH <br />ADDED AT SITE. <br />BASED ON ASTM <br />CONCRETE <br />2. PROVIDE A SET OF (4) FOUR CYLINDERS TO BE TAKEN FOR EVERY 100 <br />C1077 <br />POUR; <br />CUBIC YARDS FOR TILT WALL AND 150 YARDS FOR ALL OTHER CONCRETE, <br />OR FRACTION THEREOF, BY TESTING LAB. <br />3. MONITOR SLUMP AND AIR CONTENT OF CONCRETE AND NOTIFY <br />DELIVERY DRIVER IF SLUMP DEVIATES MORE THAN PLUS OR MINUS 1 INCH <br />FROM RECOMMENDED VALUE. CONTACT SUPPLIER FOR FURTHER <br />DIRECTIONS. <br />F. PLACEMENT OF CONCRETE & SHOTCRETE. <br />CONTINUOUS <br />INSPECTION FOR PROPER APPLICATION TECHNIQUES. <br />ACI 318-CH. 5.9, <br />*QUALIFICATIONS <br />5.10 <br />BASED ON ASTM <br />C1077 <br />G. MAINTENANCE OF SPECIFIED CURING <br />PERIODIC <br />EACH CONCRETE POUR. <br />ACI 318-CH. 5.11, <br />*QUALIFICATIONS <br />TEMPERATURE & TECHNIQUES. <br />5.13 <br />BASED ON ASTM <br />C1077 <br />H. REMOVAL OF SHORES AND FORMS FROM <br />PERIODIC <br />VERIFY IN -SITU CONCRETE STRENGTH PRIOR TO REMOVAL. <br />ACI 318-CH, 6.2 <br />*QUALIFICATIONS <br />BEAMS AND WALLS. <br />BASED ON ASTM <br />E329 <br />NOTES: <br />1. THESE INSPECTIONS DO NOT RELIEVE THE ENGINEER FROM STRUCTURAL OBSERVATIONS AS MAY BE REQUIRED BY IBC 2009, SECTION 1709, AND/OR CONTRACTUAL <br />REQUIREMENTS OF ARCHITECT/CLIENT. <br />2. DEFINITIONS (IBC SECTION 1702): <br />A. PERIODIC INSPECTIONS - THE PART-TIME OR INTERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR <br />WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT THE COMPLETION OF THE WORK. <br />B. CONTINUOUS INSPECTIONS - THE FULL TIME OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT <br />IN THE AREA WHERE THE WORK IS BEING PERFORMED. <br />3. ABBREVIATIONS: <br />A. ADSC - THE INTERNATIONAL ASSOCIATION OF FOUNDATION DRILLING <br />B. ASNT - AMERICAN SOCIETY FOR NONDESTRUCTIVE TESTING <br />C. ASTM - AMERICAN SOCIETY FOR TESTING MATERIALS <br />D. AWS -AMERICAN WELDING SOCIETY <br />E. CWI - CERTIFIED WELDING INSPECTOR <br />F. CRSI - CONCRETE REINFORCING STEEL INSTITUTE <br />G. PCI - PRECAST/PRESTRESSED CONCRETE INSTITUTE <br />H. PTI - POST -TENSIONING INSTITUTE <br />I. N/A -NOT APPLICABLE <br />4. TESTING AND INSPECTION DIRECTED BY ASTM E329 GUIDELINES. <br />5. INSPECTION REPORTS SHOULD BE PREPARED ACCORDING TO IBC, SECTION 1704.1.2, WHICH STATES: <br />A. SPECIAL INSPECTORS SHALL KEEP RECORDS OF INSPECTIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, <br />AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. REPORTS SHALL INDICATE THAT WORK INSPECTED WAS DONE IN CONFORMANCE <br />TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF <br />THE DISCREPANCIES ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL AND TO THE REGISTERED <br />DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE PRIOR TO THE COMPLETION OF THAT PHASE OF THE WORK. A FINAL REPORT DOCUMENTING REQUIRED <br />SPECIAL INSPECTIONS AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS SHALL BE SUBMITTED AT A POINT IN TIME AGREED UPON BY THE <br />PERMIT APPLICANT AND THE BUILDING OFFICIAL PRIOR TO THE START OF WORK. <br />6. CONTRACTOR RESPONSIBILITIES ARE LISTED IN IBC, SECTION 1706, WHICH STATES: <br />A. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND- OR SEISMIC -FORCE -RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM OR A <br />WIND- OR SEISMIC -RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO <br />THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF <br />RESPONSIBILITY SHALL CONTAIN THE FOLLOWING: <br />• ACKNOWLEDGMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS; <br />• ACKNOWLEDGMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING <br />OFFICIAL; <br />• PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE <br />DISTRIBUTION OF THE REPORTS; AND <br />• IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION. <br />7. GENERAL REQUIREMENTS FOR INSPECTIONS ARE LISTED <br />A. IN IBC, SECTION 109.1, WHICH STATES: <br />• CONSTRUCTION OR WORK FOR WHICH A PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR <br />WORK SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES UNTIL APPROVED. <br />• IT SHALL BE THE DUTY OF THE PERMIT APPLICANT TO CAUSE THE WORK TO REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER THE <br />BUILDING OFFICIAL NOR THE JURISDICTION SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO <br />ALLOW INSPECTION. <br />B. IN IBC, SECTION 109.4, WHICH STATES: <br />• THE BUILDING OFFICIAL IS AUTHORIZED TO ACCEPT REPORTS OF APPROVED INSPECTION AGENCIES, PROVIDED SUCH AGENCIES SATISFY THE <br />REQUIREMENTS AS TO QUALIFICATIONS AND RELIABILITY. <br />C. IN IBC, SECTION 109.5, WHICH STATES: <br />• IT SHALL BE THE DUTY OF THE HOLDER OF THE BUILDING PERMIT OR THEIR DULY AUTHORIZED AGENT TO NOTIFY THE BUILDING OFFICIAL WHEN WORK IS <br />READY FOR INSPECTION. <br />• IT SHALL BE THE DUTY OF THE PERMIT HOLDER TO PROVIDE ACCESS TO AND MEANS FOR INSPECTIONS OF SUCH WORK THAT ARE REQUIRED BY THIS CODE. <br />D. IN IBC, SECTION 109.6, WHICH STATES: <br />• WORK SHALL NOT BE DONE BEYOND THE POINT INDICATED IN EACH SUCCESSIVE INSPECTION WITHOUT FIRST OBTAINING THE APPROVAL OF THE BUILDING <br />OFFICIAL. <br />IBC SECTION & <br />REQUIRED INSPECTION <br />FREQUENCY OF <br />REFERENCE <br />INSPECTOR <br />VERIFICATION, OR TEST <br />INSPECTION <br />TYPE AND/OR FREQUENCY OF TESTING <br />CRITERIA <br />QUALIFICATIONS <br />STEEL CONSTRUCTION <br />IBC 1704.3 <br />A. MATERIAL VERIFICATION <br />PERIODIC <br />1. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS <br />STRUCTURAL <br />CWI/ASSOCIATE/ <br />OF HIGH -STRENGTH BOLTS. <br />SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. <br />STEEL GENERAL <br />TECHNICAL, <br />NUTS AND WASHERS: <br />NOTES <br />RADIATE, AWS <br />OR CRSI <br />PERIODIC <br />2. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. <br />APPLICABLE <br />ASTM MATERIAL <br />SPECIFICATIONS: <br />AISC 335, <br />SECTION A3.4; <br />AISC LRFD, <br />SECTION A3.3 <br />B. HIGH STRENGTH BOLTING: <br />PERIODIC <br />1. BEARING -TYPE CONNECTIONS. <br />FBC 1704.3.3; <br />CWI/ASSOCIATE/ <br />STRUCTURAL <br />TECHNICAL, <br />STEEL GENERAL <br />RADIATE AWS <br />NOTES <br />OR CRSI <br />PERIODIC/ <br />2. SLIP -CRITICAL CONNECTIONS, <br />AISC LRFD <br />CONTINUOUS <br />SECTION M2.5 <br />C. MATERIAL VERIFICATION <br />PERIODIC <br />0 <br />1. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS <br />FBC 1708.4• <br />CWI/ASSOCIATE/ <br />OF STRUCTURAL STEEL: <br />SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. <br />STRUCTURAL <br />TECHNICAL, <br />STEEL, GENERAL <br />RADIATE, AWS <br />NOTES <br />OR CRSI <br />PERIODIC <br />2. MANUFACTURER'S CERTIFIED MILL TEST REPORTS. <br />ASTM A6 OR <br />ASTM A 568 <br />D. MATERIAL VERIFICATION <br />PERIODIC <br />1. IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION IN THE <br />STRUCTURAL <br />CWI/ASSOCIATE/ <br />OF WELD FILLER MATERIALS: <br />APPROVED CONSTRUCTION DOCUMENTS. <br />STEEL, GENERAL <br />TECHNICAL, <br />NOTES <br />RADIATE, AWS <br />OR CRSI <br />PERIODIC <br />2. MANUFACTURER'S CERTIFIED OF COMPLIANCE REQUIRED. <br />AISC, ASD. <br />SECTION A3.6; <br />AISC LRFD <br />SECTION A3.5 <br />E. WELDING OF STRUCTURAL <br />CONTINUOUS <br />1. COMPLETE & PARTIAL PENETRATION GROOVE WELDS. <br />FBC 1704.3.1; <br />CWI AND ASNT <br />STEEL: <br />STRUCTURAL <br />STEEL, GENERAL <br />NOTES <br />CONTINUOUS <br />2. MULTIPASS FILLET WELDS. <br />AWS D1.1 <br />CWI AND ASNT <br />OR LICENSED <br />CONTINUOUS <br />3. SINGLE -PASS FILLET WELDS > %6" <br />ENGINEER <br />PERIODIC <br />4. SINGLE -PASS FILLET WELDS <%6" <br />PERIODIC <br />5. FLOOR AND ROOF DECK WELDS. <br />AWS D1.3 <br />F. WELDING OF REINFORCING <br />PERIODIC <br />1. VERIFICATION OF WELD ABILITY OF REINFORCING STEEL OTHER THAN <br />CWI/ASSOCIATE/ <br />STEEL: <br />A706. <br />TECHNICIAN <br />TRAINED IN FIELD <br />CONTINUOUS <br />2. REINFORCING STEEL -RESISTING FLEXURAL AND AXIAL FORCES IN <br />OF WORK AND <br />INTERMEDIATE AND SPECIAL MOMENT FRAMES, AND BOUNDARY <br />HAS AT LEAST <br />ELEMENTS OF SPECIAL REINFORCED CONCRETE SHEAR WALLS AND <br />ONE YEAR OF <br />SHEAR REINFORCEMENT. <br />EXPERIENCE. <br />CONTINUOUS <br />3. SHEAR REINFORCEMENT. <br />PERIODIC <br />4. OTHER REINFORCING STEEL. <br />G. STEEL FRAME JOINT <br />PERIODIC <br />1. DETAILS SUCH AS BRACING & STIFFENING <br />FBC 1704.3.2 <br />PROJECT OF <br />DETAILS; COMPLIANCE WITH <br />STRUCTURAL <br />COMPLEX <br />APPROVED CONSTRUCTION <br />DRAWINGS <br />DETAILS: <br />DOCUMENTS: <br />-ASSOCIATE CWI <br />PERIODIC <br />2. MEMBER LOCATIONS. <br />PROJECTS OF <br />RELATIVELY <br />PERIODIC <br />3. APPLICATION OF JOINT DETAILS AT EACH CONNECTION. <br />SIMPLE DETAILS: <br />-TECHNICIAN <br />TRAINED IN FIELD <br />OF WORK AND <br />HAS AT LEAST <br />ONE YEAR OF <br />EXPERIENCE. <br />IBC SECTION & <br />REQUIRED INSPECTION <br />FREQUENCY OF <br />REFERENCE <br />INSPECTOR <br />VERIFICATION, OR TEST <br />INSPECTION <br />TYPE AND/OR FREQUENCY OF TESTING <br />CRITERIA <br />QUALIFICATIONS <br />MASONRY <br />ENGINEERED MASONRY IN NON -ESSENTIAL FACILITIES AND EMPIRICALLY <br />FBC 1704.5.1, <br />QUALIFICATIONS <br />LEVEL 1 INSPECTION <br />DESIGNED MASONRY IN ESSENTIAL FACILITIES. (OCCUPANCY CATEGORY I, <br />11, OR III) <br />FBC 1704.5.2 <br />BASED ON ASTM <br />C1093 <br />A. AS MASONRY CONSTRUCTION BEGINS, THE <br />PERIODIC <br />1. PROPORTIONS OF SITE -PREPARED MORTAR. <br />FOLLOWING SHALL BE VERIFIED TO ENSURE <br />PERIODIC <br />2. CONSTRUCTION OF MORTAR JOINTS. <br />COMPLIANCE: <br />PERIODIC <br />3. LOCATION OF REINFORCEMENT AND CONNECTORS. <br />PERIODIC <br />4. PRESTRESSING TECHNIQUE <br />PERIODIC <br />5. GRADE AND SIZE OF PRESTRESSING TENDONS AND ANCHORAGES. <br />B. THE INSPECTION PROGRAM SHALL VERIFY: <br />PERIODIC <br />1. SIZE AND LOCATION OF STRUCTURAL ELEMENTS. <br />PERIODIC <br />2. TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF <br />ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES, OR <br />OTHER CONSTRUCTION. <br />PERIODIC <br />3. SPECIFIED SIZE, GRADE AND TYPE OF REINFORCEMENT. <br />CONTINUOUS <br />4. WELDING OF REINFORCING BARS. <br />PERIODIC <br />5. PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURE <br />BELOW 40 DEGREES F) OR HOT WEATHER (TEMPERATURE ABOVE 90 <br />DEGREES F). <br />PERIODIC <br />6. APPLICATION AND MEASUREMENT OF PRESTRESSING FORCE. <br />C. PRIOR TO GROUTING, THE FOLLOWING SHALL BE <br />PERIODIC <br />1. GROUT SPACE IS CLEAN. <br />VERIFIED TO ENSURE COMPLIANCE: <br />PERIODIC <br />2. PLACEMENT OF REINFORCEMENT AND CONNECTORS AND <br />PRESTRESSING TENDONS AND ANCHORAGES. <br />PERIODIC <br />3. PROPORTIONS OF SITE -PREPARED GROUT AND PRESTRESSING <br />GROUT FOR BONDED TENDONS. <br />PERIODIC <br />4. CONSTRUCTION OF MORTAR JOINTS. <br />D. GROUT PLACEMENT <br />CONTINUOUS <br />1. VERIFY COMPLIANCE WITH CODE AND CONSTRUCTION <br />DOCUMENTS PROVISIONS. <br />CONTINUOUS <br />2. GROUTING OF PRESTRESSING BONDED TENDONS. <br />E. PREPARATION OF ANY REQUIRED GROUT <br />CONTINUOUS <br />QUALIFICATIONS <br />SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS <br />BASE ON C1093 <br />SHALL BE OBSERVED. <br />F. COMPLIANCE WITH REQUIRED INSPECTION <br />PERIODIC <br />PROVISION OF THE CONSTRUCTION DOCUMENTS <br />AND THE APPROVED SUBMITTALS SHALL BE <br />VERIFIED. <br />SPECIAL CONDITIONS, REQUIREMENTS AND NOTES TO OWNER, <br />CONCRETE: <br />STRUCTURAL STEEL: <br />DEVELOPER AND CONTRACTOR: <br />1. MINIMUM 28 DAY STRENGTH ft) SHALL BE AS FOLLOWS: <br />1. STRUCTURAL STEEL MEMBERS SHALL CONFORM WITH THE FOLLOWING STANDARDS AND <br />FOUNDATIONS 4000 PSI, W/C = 0.50 BY WEIGHT (AIR -ENTRAINED) <br />MATERIAL PROPERTIES UNLESS NOTED OTHERWISE: <br />CONTRACTOR, BUILDER AND SUBCONTRACTORS INVOLVED IN ANY FORM OF CONSTRUCTION USING THESE <br />INT. SLABS ON GROUND 4000 PSI, W/C = 0.5 BY WEIGHT <br />DOCUMENTS SHALL BE INFORMED OF THE FOLLOWING RESPONSIBILITIES, PERFORMANCE CRITERIA, LIMITATIONS AND <br />OTHER EXPOSED CONCRETE 3000 PSI, W/C = 0.50 BY WEIGHT (AIR -ENTRAINED) <br />SHAPE <br />STANDARD <br />a <br />RISKS ASSOCIATED WITH CONSTRUCTION. IF THE OWNER, DEVELOPER OR CONTRACTOR IS NOT ABLE TO ACCEPT THE <br />RESPONSIBILITIES OR PERFORMANCE CRITERIA AND LIMITATIONS, NOTIFY OUR OFFICE PRIOR TO START OF <br />2. CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE ENGINEER. <br />ROLLED WIDE FLANGE SECTIONS: <br />ASTM A992 <br />50 KSI <br />CONSTRUCTION. IT SHALL BE EXPRESSLY UNDERSTOOD THAT THE ENGINEER IS NOT RESPONSIBLE OR LIABLE FOR <br />THE LACK OF PERFORMANCE OF MATERIALS, SYSTEMS OR DESIGNS NOT BEING LIMITED TO ITEMS OUTLINED BELOW. <br />3. ALL CONCRETE SHALL BE REGULAR WEIGHT OF 145 POUNDS PER CUBIC FOOT USING HARDROCK AGGREGATES. <br />OTHER STANDARD STEEL SHAPES <br />AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33, CONCRETE AGGREGATES. <br />AND ROLLED SECTIONS: <br />ASTM A36 <br />36 KSI <br />CONTRACTORS AND SUBCONTRACTORS SHALL THOROUGHLY REVIEW ALL CONDITIONS AND RESPONSIBILITIES <br />STATED IN THESE NOTES, PLANS, SECTIONS AND DETAILS, AND SHALL NOTIFY THE ENGINEER AND OWNER !N WRITING <br />4. MAXIMUM SLUMP FOR EXTERIOR SLABS SHALL BE 5 INCHES. MAXIMUM SLUMP FOR ALL OTHER CONCRETE SHALL <br />BARS AND PLATES: <br />ASTM A36 <br />36 KSI <br />PRIOR TO CONSTRUCTION OF ANY CONDITIONS OR RESPONSIBILITIES WHICH ARE NOT ACCEPTABLE OR NOT <br />BE 4 INCHES. WATER SHALL BE CLEAN AND POTABLE. IF ADDITIONAL FLOWABILITY IS REQUIRED FOR PLACEMENT OF <br />UNDERSTOOD. <br />ANY CONCRETE MIX, A WATER -REDUCING ADDITIVE CONFORMING TO ASTM C494, TYPE A, SHALL BE USED. NO <br />TUBES: <br />ASTM A500 <br />46 KSI <br />1. PLAIN CONCRETE, REINFORCED CONCRETE, AND PRECAST CONCRETE DEVELOPS CRACKS. THE CRACKS ARE DUE <br />PIPE: AS I M AbJ UK.b Jb K51 <br />TO INHERENT SHRINKAGE, CREEP AND RESTRAINING EFFECTS. CRACKS ARE NORMALLY COSMETIC AND THE SYSTEM <br />5. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150. TYPE II CEMENT WITH A MAXIMUM CHLORIDE ION, PERCENT <br />OR A500 GR.B 42 KSI <br />BY WEIGHT OF CEMENT, SHALL NOT EXCEED 0.15. <br />MAINTAINS SERVICEABILITY AND STRENGTH REQUIREMENTS. JOINTS MAY BE INDICATED TO CONTROL CRACKING, BUT <br />BOLTS AT STEEL CONNECTIONS: ASTM A325 OR A490 <br />ARE NOT MEANT TO ELIMINATE ALL CRACKING, AS THIS IS NOT PRACTICAL. THE CONTRACTOR SHALL USE ALL <br />6. NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT, UNLESS <br />STANDARD MEANS TO INSURE PROPER PROTECTION AND CURING OF ALL CEMENTITIOUS MATERIALS TO REDUCE <br />APPROVED BY THE ENGINEER OR AUTHORIZED TESTING AGENCY. <br />2. ALL BOLTS SHALL BE INSTALLED AS BEARING -TYPE CONNECTIONS WITH THREADS <br />CRACKING, SURFACE SPALLING OR EXTREME CRACKING MAY BE CAUSED BY POOR MATERIAL OR PLACEMENT. <br />EXCLUDED FROM SHEAR PLANE (TYPE "X" CONNECTION), UNLESS NOTED OTHERWISE. <br />CONTACT OUR OFFICE FOR POSSIBLE REPAIR REQUIREMENTS. <br />7. CONCRETE MIXING, PLACEMENT AND QUALITY SHALL BE PER IBC SECTION 1904, ASTM C 94, ASTM C 685, AND ACI <br />HIGH -STRENGTH BOLTS SHALL BE TIGHTENED USING ANY AISC APPROVED METHOD. <br />302. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT SLABS ON GRADE NEED ONLY BE VIBRATED OR <br />2. FOUNDATION SETTLEMENT MAY CAUSE DISTORTION AND DISTRESS TO THE SUPPORTED STRUCTURE AS WELL AS <br />THOROUGHLY RODDED AROUND EMBEDDED STRAPS OR HARDWARE BOLTS FOR HOLDOWNS CURBS AND EDGES OF <br />D ID <br />3. WELDING SHALL BE PERFORMED BY WELDERS HOLDING VALID CERTIFICATES AND HAVING <br />ADJACENT UTILITIES, SLABS OR FOUNDATIONS. THE SOIL REPORT MAY INDICATE A LEVEL OF DISPLACEMENT. <br />SLAB STEPS AND UNDER FLOOR DUCTS OR SIMILAR ELEMENTS. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING <br />CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS. ALL WELDING <br />CONCRETE. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN WALLS AND COLUMNS SO AS <br />SHALL USE E70 SERIES LOW HYDROGEN ELECTRODES UNLESS NOTED OTHERWISE. ALL <br />ATTENTION TO PROPER SOIL PREPARATION AND GRADING, AS WELL AS PROPER DRAINAGE AWAY FROM STRUCTURE <br />TO CAUSE SEGREGATION OF AGGREGATES. UNCONFINED FALL SHALL NOT EXCEED 5 FEET. CARE SHALL BE TAKEN <br />WELDS INVOLVING REINFORCING BARS SHALL USE E90 SERIES ELECTRODES. ALL WELDING <br />IS ESSENTIAL IN REDUCING EXPECTED SETTLEMENT. <br />IN PLACING SLABS ON GRADE SO AS CONCRETE DOES NOT DISTURB FILL MATERIAL. <br />SHALL CONFORM TO THE LATEST AMERICAN WELDING SOCIETY (AWS) STANDARDS. WELDS <br />ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD <br />AND/OR <br />3. VARIATION IN DIMENSIONS MAY OCCUR AS A RESULT OF THERMAL INFLUENCES, NATURAL DEFLECTIONS D/0 <br />8. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING DOWELS BOLTS ANCHORS SLEEVES ETC. SHALL BE <br />TESTED AND <br />WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE ES <br />CAMBERS OF MEMBERS. AS A RESULT, QUANTITIES MAY VARY AND ARCHITECTURAL FINISHES MAY BE AT RISK OF <br />SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. <br />CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. <br />COSMETIC VARIATION OR DAMAGE. <br />9. CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL <br />4. GROUT BENEATH COLUMN BASES OR BEARING PLATES SHALL BE 5,000 PSI (MIN) <br />4. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR VARIATIONS TO PLANS BETWEEN BID PROCESS AND FINALIZED <br />DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE <br />NON -SHRINK FLOWABLE GROUT OR DRYPACK. INSTALL GROUT UNDER BEARING PLATES <br />BOUNDED BY KEYED, DOWELED OR SAW -CUT CONTROL JOINTS SUCH THAT THE ENCLOSED AREA DOES NOT EXCEED <br />BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL GROUT UNDER BASE <br />APPROVED DOCUMENTS RELEASED FOR CONSTRUCTION. ADDITIONS AND ALTERATIONS MAY BE MADE BETWEEN <br />144 SQUARE FEET. RATIO OF BOUNDARY DIMENSIONS SHALL NOT EXCEED 1.5:1. KEYED OR DOWELED CONTROL <br />PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. <br />RELEASE OF BID DOCUMENTS AND FINALIZED CONSTRUCTION DOCUMENTS. <br />JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING. ALL OTHER JOINTS MAY BE SAW CUT. SAW CUT <br />GROUT DEPTH SHALL BE SUFFICIENT TO ALLOW GROUT OR DRYPACK TO BE PLACED <br />JOINTS SHALL BE CUT IN SLABS ON GRADE AS SOON AS POSSIBLE AFTER SLAB FINISHING AS MAY BE SAFELY DONE <br />BENEATH PLATE WITHOUT VOIDS. <br />5. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS <br />WITHOUT DISLODGING AGGREGATE. <br />NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEERS IN THIS OR <br />5. DETAILS OUTLINE BASIC CONNECTION TYPES. BEAM TO BEAM AND BEAM TO COLUMN <br />SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN <br />10. CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (TILT -UP WALL PANELS) NOT SPECIFICALLY <br />CONNECTIONS NOT DETAILED IN DRAWINGS SHALL BE SIZED BY STEEL DETAILER AS <br />EXPERIENCED CONTRACTOR, SUBCONTRACTOR AND/OR WORKPERSONS WHO HAVE A WORKING KNOWLEDGE OF THE <br />SHOWN OR NOTED ON THE DRAWINGS REQUIRE PROPER APPROVAL OF THE ENGINEER. CONTRACTOR SHALL <br />STANDARD AISC, TYPE 2, BEARING CONNECTIONS CAPABLE OF SUPPORTING REACTIONS <br />SUBMIT SHOP DRAWINGS SHOWING PROPOSED JOINTS TO ENGINEER FOR APPROVAL. <br />DEVELOPED BY MAXIMUM UNIFORM LOAD CAPACITY ON A SIMPLE SPAN FOR BEAM AND <br />APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS <br />BEAM SPAN GIVEN. <br />NOT EVERY CONDITION OR ELEMENT IS OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS. IT IS UNDERSTOOD <br />( <br />11. WHERE DOWELS, BOLTS OR INSERTS ARE CALLED TO BE ANCHORED TO CAST IN PLACE CONCRETE ELEMENTS <br />THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL WORK EXPLICITLY <br />USING EPDXY ADHESIVES, USE ANCHORAGE SYSTEM EQUAL TO EPCON G5. FOLLOW ALL MANUFACTURERS <br />6. STEEL SHALL BE DESIGNED, DETAILED, FABRICATED AND ERECTED ACCORDING TO ALL <br />SHOWN. <br />RECOMMENDATIONS. ALTERNATE ANCHORAGE SYSTEMS MAY BE USED WITH ENGINEERS PRIOR APPROVAL. <br />APPLICABLE SECTIONS OF THE LATEST EDITION OF THE AISC MANUAL OF STEEL <br />CONSTRUCTION. SHOP DRAWINGS SHALL BE SUBMITTED INDICATING COMPLETE <br />6. CALCULATION AND DESIGN OF MISCELLANEOUS NON-STRUCTURAL ITEMS, SUCH AS RAILINGS, NON-STRUCTURAL <br />FOUNDATIONS: <br />INFORMATION REQUIRED FOR CONSTRUCTION OF STRUCTURAL STEEL. SHOP DRAWINGS <br />WALLS AND PREFABRICATED STRUCTURAL ITEMS, SUCH AS FLOOR AND ROOF TRUSSES, ARE NOT INCLUDED AND ARE <br />1. GEOTECHNICAL REPORT: NONE PROVIDED <br />SHALL INCLUDE LAYOUT AND DIMENSIONS OF FRAMING PLANS, CONNECTION DETAILS, AND <br />TO BE PROVIDED BY OTHERS UNLESS SPECIFICALLY NOTED ON THESE DRAWINGS. <br />SEQUENCE, ETC. SHOP DRAWINGS AND CALCULATIONS SHALL BE SEALED BY A <br />STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT SITE. <br />2. THE OWNER SHALL EMPLOY A GEOTECHNICAL ENGINEER TO PROVIDE SOIL TESTING AND REVIEW DURING <br />7. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF <br />CONSTRUCTION. THE GEOTECHNICAL ENGINEER SHALL REVIEW AND APPROVE THE FOUNDATION REQUIREMENTS <br />7. FIELD CUTTING, DRILLING OR OTHER MODIFICATION OF STRUCTURAL STEEL <br />CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, <br />OF THE CONTRACT DOCUMENTS. IF CONDITIONS VARY FROM THAT INDICATED HEREIN, THEN THE GEOTECHNICAL <br />COMPONENTS IS NOT PERMITTED WITHOUT WRITTEN APPROVAL OF THE STRUCTURAL <br />TECHNIQUES, SEQUENCES AND PROCEDURES. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DESIGN AND <br />ENGINEER SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO FOUNDATION CONSTRUCTION. <br />ENGINEER. WHERE BEAM PENETRATIONS CANNOT BE AVOIDED OR WHERE CUTTING IS <br />PROVIDE ADEQUATE, SHORING, BRACING, FORMWORK, ETC. AS REQUIRED FOR THE PROTECTION OF LIFE AND <br />3. THE BACKFILL SHALL BE PLACED AND COMPACTED ON EACH SIDE OF FOUNDATION WALLS SUCH THAT NO <br />REQUIRED, CONTRACTOR SHALL SUBMIT TO THE ENGINEER, ALL PERTINENT INFORMATION <br />PROPERTY DURING CONSTRUCTION. CONSTRUCTION MATERIALS SHALL BE UNIFORMLY SPREAD OUT SUCH THAT <br />UNBALANCED LATERAL LOADS ARE INDUCED TO THE WALL. <br />INCLUDING PENETRATION SHAPE, SIZE LOCATION AND METHOD OF CUTTING THE OPENING. <br />DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED, VISITS TO THE SITE BY THE <br />STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. <br />4. BACKFILL SHALL BE PLACED EVENLY AGAINST EACH SIDE OF SUBGRADE STRUCTURAL ELEMENTS TO PRODUCE <br />MISCELLANEOUS STEEL: <br />APPROXIMATELY EQUAL AND OPPOSITE LATERAL PRESSURES. <br />8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING SHORING AND <br />1. PROVIDE L4x4x3/ EDGE ANGLE AT ALL ROOF DECK EDGES UNLESS NOTED OTHERWISE. <br />PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH THE LOCAL <br />5. PROVIDE PERIMETER DRAINAGE AS INDICATED IN SOILS REPORT. <br />BUILDING DEPARTMENT. ALL WORK OR CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES UIL G C U <br />SLAB ON GRADE: <br />2. PROVIDE AN L3x3xYa H FRAME BELOW ALL ROOF DRAINS UNLESS NOTED OTHERWISE. <br />REGULATIONS AND SAFETY REQUIREMENTS. <br />1. TYPICAL CONCRETE SLAB ON GRADE SHALL BE 4" THICK WITH #4 @ 18" O.C. <br />3. REFER TO MEP/HVAC DRAWINGS FOR LOCATIONS OF ROOF OR FLOOR MOUNTED <br />9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS, CONDITIONS AND ELEVATIONS <br />MECHANICAL EQUIPMENT. CONTRACTOR SHALL COORDINATE MEP/HVAC UNIT LOCATIONS <br />WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. THE CONTRACTOR SHALL INFORM THE <br />2 CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON SELECT FILL MATERIAL AS NOTED ABOVE. FILL MATERIAL <br />AND VERIFY CONFORMANCE WITH STRUCTURAL FRAMING PLANS. <br />SHOULD BE MOISTENED, BUT NOT SATURATED JUST PRIOR TO PLACING CONCRETE. CARE SHALL BE TAKEN IN <br />ARCHITECT IN WRITING OF ANY DISCREPANCIES OR OMISSIONS NOTED ON THE DRAWINGS. ANY SUCH DISCREPANCY, <br />PLACING SLABS ON GRADE SO AS NOT TO DISTURB FILL MATERIAL OR REINFORCING. THE FILL MATERIAL SHALL BE <br />OMISSION OR VARIATION NOT REPORTED BEFORE THE START OF CONSTRUCTION SHALL BE THE RESPONSIBILITY OF <br />COMPACTED TO NO LESS THAN 95% COMPACTION @ MOISTURE CONTENT RANGE OF 3% BELOW TO 3% ABOVE <br />4. PROVIDE ALL EMBED PLATES, LEDGERS, LINTELS AND BRACKETS AS REQUIRED FOR A <br />THE CONTRACTOR. <br />OPTIMUM MOISTURE CONTENT BEFORE PLACEMENT OF SLABS. <br />COMPLETE SYSTEM AS OUTLINED IN THE CONTRACT DOCUMENTS. <br />10. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE <br />SHALLOW SPREAD FOOTINGS; <br />5. REFER TO STRUCTURAL STEEL NOTES FOR REQUIRED ASTM DESIGNATIONS FOR <br />LATEST EDITION AND/OR ADDENDA. <br />1. MIN FOOTING DEPTH IS 12 INCHES BELOW GRADE. <br />VARIOUS STEEL SHAPES AND PLATES AS WELL AS FINISHES, CONNECTION INFORMATION <br />AND QUALITY CONTROL. <br />11.OPTIONS ARE FOR CONTRACTORS CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE <br />2. ASSUMED ALLOWABLE FOOTING BEARING IS 1500 PSF <br />RESPONSIBLE FOR ALL NECESSARY CHANGES AND SHALL COORDINATE ALL DETAILS. <br />6. MECHANICAL CONTRACTOR SHALL DESIGN AND SUPPLY ALL FRAMING AS REQUIRED TO <br />3. ALL FOOTINGS SHALL EXTEND TO DEPTH NOTED ABOVE U.N.O.ON PLANS OR DETAIL. GRADE IS DEFINED AS TOP <br />OF SLAB FOR INTERIOR FOOTINGS, AND LOWEST ADJACENT COMPACTED SUBGRADE (PAD GRADE BEFORE <br />SUPPORT OR SUSPENDED EQUIPMENT, DUCTS AND PIPING BETWEEN FRAMING OUTLINED IN <br />12. TYPICAL DETAILS AND NOTES SHALL APPLY, THOUGH NOT NECESSARILY AT A SPECIFIC LOCATION ON PLANS. <br />LANDSCAPING) OR NATURAL GRADE WITHIN 5 FEET OF BUILDING FOR PERIMETER FOOTINGS. GRADE IS DEFINED AS <br />THE CONTRACT DOCUMENTS. REFER TO MEP / HVAC DRAWINGS FOR LOCATIONS AND <br />WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, DETAILS <br />TOP OF EXTERIOR PAVING OR CONCRETE WHERE EXTERIOR PAVING OR CONCRETE IS PERMANENTLY LOCATED <br />WEIGHTS OF ITEMS TO BE SUPPORTED OR SUSPENDED. <br />MAY ONLY SHOW ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. WHERE DISCREPANCIES <br />DIRECTLY ADJACENT TO BUILDING AND EXTENDS AT LEAST 5 FEET FROM BUILDING. FOOTING EXCAVATIONS SHALL <br />OCCUR IN THESE DRAWINGS, NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL <br />BE CLEAN AND FREE FROM LOOSE DEBRIS, STANDING WATER, OR UNCOMPACTED MATERIAL AT TIME OF CONCRETE <br />7. PROVIDE AN 1_50Y4/16 "H" FRAME BELOW ALL ROOF MOUNTED MECHANICAL EQUIPMENT <br />STRUCTURAL NOTES AND TYPICAL DETAILS. <br />PLACEMENT. <br />UNLESS NOTED OTHERWISE. <br />13. ALL OPENINGS ARE NOT SHOWN ON THESE DRAWINGS. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR <br />4. EXCAVATION FOR FOOTINGS SHALL BE CUT TO ACCURATE SIZE AND DIMENSIONS AS SHOWN ON PLANS. ALL SOIL <br />BELOW SLABS AND FOOTINGS SHALL BE PROPERLY COMPACTED AND SUBGRADE BROUGHT TO A REASONABLE TRUE <br />BASIS FOR DESIGN: <br />ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND <br />AND LEVEL PLANE BEFORE PLACING CONCRETE. <br />SUBCONTRACTORS PRIOR TO CONSTRUCTION, OPENINGS MAY REQUIRE ADDITIONAL REINFORCING OR SUPPORTS AS <br />BUILDING CODE: FLORIDA BUILDING CODE 2010 <br />SHOWN ON TYPICAL DETAILS. IF TYPICAL DETAILS FOR ALL CONDITIONS ARE NOT INCLUDED HEREIN, IT SHALL BE THE <br />5. SITE PREPARATION AND GRADING REQUIREMENTS OF THE GEOTECHNICAL REPORT AND ANY ADDENDA SHALL BE <br />RESPONSIBILITY OF THE CONTRACTOR TO REQUEST IN WRITING ADDITIONAL INFORMATION. <br />COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS, INSPECTIONS, FIELD OBSERVATIONS, OR <br />1. DEAD LOADS <br />APPROVAL FROM THE GEOTECHNICAL ENGINEER SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION <br />A. ROOF (EXISTING)..................................27 PSF (ASSUMED FOR BALLASTED ROOF) <br />14. ALL INSPECTIONS REQUIRED BY THE BUILDING CODES, LOCAL BUILDING OFFICIALS, OR BY THESE PLANS SHALL BE <br />REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO <br />PROVIDED BY AN INDEPENDENT INSPECTION COMPANY OR, THE BUILDING DEPARTMENT. INSPECTION REQUIREMENTS <br />THE ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. <br />2. LIVE LOADS <br />STATED HEREIN ARE PARTIAL. COMPLETE INSPECTION REQUIREMENTS SHALL BE AS DIRECTED BY THE LOCAL <br />MASONRY (CONCRETE BLOCK): <br />A. ROOF (EXISTING)..................................20 PSF <br />BUILDING DEPARTMENT. SITE VISITS BY THE ENGINEER DO NOT CONSTITUTE AN INSPECTION, UNLESS SPECIFICALLY <br />CONTRACTED FOR. <br />1. COMPRESSIVE STRENGTH OF CONCRETE MASONRY CONSTRUCTION, (CMU) SHALL BE AS FOLLOWS (PSI). MASONRY <br />3. SNOW LOAD <br />STRENGTH NOT SPECIFICALLY NOTED ON PLAN SHALL BE (F'm)1500 PSI. <br />A. GROUND SNOW, Pg = 0 PSF <br />15. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. SHOP DRAWINGS ARE REVIEWED ONLY FOR <br />MASONRY STRENGTH (F'm DESIGN) = 1500 PSI <br />B. FLAT ROOF SNOW LOAD, Pf = 0 PSF <br />GENERAL COMPLIANCE WITH THE STRUCTURAL DRAWINGS. REVIEW DOES NOT INDICATE THAT THE SHOP DRAWINGS <br />BLOCK STRENGTH = 1900 PSI <br />C. EXPOSURE FACTOR, Ce =1.0 <br />ARE CORRECT OR COMPLETE. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ANY <br />TYPE M MORTAR STRENGTH = 2500 PSI <br />D. IMPORTANCE FACTOR, Is =1.0 <br />CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE <br />TYPE S MORTAR STRENGTH = 1800 PSI <br />E. THERMAL FACTOR, Ct = 1.0 <br />AFOREMENTIONED SHALL NOT BE CONSIDERED APPROVED AFTER ENGINEER'S REVIEW UNLESS SPECIFICALLY NOTED <br />GROUT STRENGTH = 3000 PSI <br />F. RAIN ON SNOW = 0 PSF <br />ACCORDINGLY. THE SHOP DRAWINGS DO NOT SUPERSEDE OR REPLACE THE ORIGINAL CONTRACT DRAWINGS. ANY <br />ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN APPROPRIATELY <br />2. CONCRETE BLOCK SHALL BE HOLLOW LOAD BEARING CONCRETE MASONRY UNITS CONFORMING TO ASTM C90, GRADE N II. <br />4. WIND LOAD <br />REGISTERED ENGINEER. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE ADEQUACY OF ENGINEERING DESIGNS <br />ALL BLOCKS SHALL BE PLACED IN RUNNING BOND CONSTRUCTION (UNLESS OTHERWISE NOTED) WITH ALL VERTICAL CELLS IN <br />A. ULTIMATE WIND SPEED (3-SECOND GUST) .......... 140 MPH <br />ALIGNMENT. <br />PERFORMED BY OTHERS. ALLOW 5 WORKING DAYS FOR THE ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL <br />B. RISK CATEGORY = "2" <br />WILL BE RETAINED FOR THE ENGINEER'S RECORDS. <br />3. MORTAR MIX SHALL CONFORM TO REQUIREMENTS OF IBC SECTION 2103.8, TYPE M OR S, TYPE M MORTAR SHALL BE USED <br />C. EXPOSURE = "B" <br />WHERE MASONRY IS IN CONTACT WITH SOIL. <br />D. INTERNAL PRESSURE COEFFICIENT = t0.18 (ENCLOSED BUILDINGS) <br />E. COMPONENT AND CLADDING <br />REINFORCING STEEL (FOR CONCRETE AND MASONRY): <br />4. GROUT: USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT SEGREGATION. ALL <br />a. ROOF <br />1. REINFORCED CONCRETE DESIGNED IN ACCORDANCE WITH THE "BUILDING CODE REQUIREMENTS FOR REINFORCED <br />CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL BE FILLED SOLID WITH GROUT. ALL MASONRY BELOW <br />1. CORNER =11.4, -38.2 PSF <br />CONCRETE" (ACI 318-05) BY THE AMERICAN CONCRETE INSTITUTE. <br />FINISHED FLOOR OR GRADE SHALL BE GROUTED. <br />2. EDGE =11.4, -38.2 PSF <br />2. REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE "ACI STANDARD: DETAILS AND <br />5. MINIMUM WALL VERTICAL REINFORCING, UNLESS NOTED OTHERWISE ON PLANS OR DETAILS, SHALL BE #5 BAR VERTICAL <br />3. INTERIOR =11.4, -32.3 PSF <br />DETAILING OF CONCRETE REINFORCEMENT" (ACI 315) AND THE "MANUAL OF ENGINEERING AND PLACING DRAWINGS <br />FULL HEIGHT IN CENTER OF GROUTED CELL AT ALL WALL INTERSECTIONS, CORNERS, WALL ENDS, JAMBS AT WALL OPENINGS, <br />b. WALL <br />FOR REINFORCED CONCRETE STRUCTURES" (ACI 315R) BY THE AMERICAN CONCRETE INSTITUTE. THE MOST <br />EACH SIDE OF CONTROL JOINTS, AND AT INTERVALS NOT TO EXCEED 48 INCHES ON CENTER. TIE AT 8'-0" VERTICALLY, WITH <br />1. EDGE = 30.0, -36.7 PSF <br />CURRENT EDITIONS OF CONCRETE REINFORCING STEEL INSTITUTE'S "REINFORCING BAR DETAILING" AND "PLACING <br />SINGLE WIRE LOOP TIE OR EQUIVALENT. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION WITH DOWELS TO MATCH AND <br />2. INTERIOR = 30.0, -33.0 PSF <br />REINFORCING BARS" MAY ALSO BE USED. <br />LAP VERTICAL REINFORCING. <br />5. SEISMIC LOAD (NOT CONSIDERED: MODIFICATIONS DO NOT EFFECT LOAD ON EXISTING MEMBERS) <br />3. REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615. REINFORCING SHALL BE GRADE 60 <br />6. MINIMUM WALL HORIZONTAL REINFORCING UNLESS NOTED OTHERWISE ON PLANS OR DETAILS SHALL BE A SINGLE # 5 BAR <br />A. Ss = 0.068 <br />(FY=60 KSI) DEFORMED BARS FOR ALL BARS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL REINFORCING <br />IN CENTER OF 8 INCH DEEP CONTINUOUS GROUTED BOND BEAM AT TOP OF PARAPET OR FREE STANDING WALL AND AT V-0" <br />B. S1 = 0.034 <br />TO BE WELDED SHALL BE ASTM A706. GRADE 60 LOW ALLOY WELDABLE STEEL. <br />INTERVALS THROUGH CONTROL JOINTS. PROVIDE BENT BARS PER TYPICAL DETAILS TO MATCH AND LAP HORIZONTAL BOND <br />A.) THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED FY BY MORE THAN 18000 PSI; AND <br />BEAM REINFORCING AT CORNERS AND WALL INTERSECTIONS TO MAINTAIN BOND BEAM CONTINUITY. USE BOND BEAM UNITS <br />C. SITE CLASS = D <br />B.) THE RATIO OF THE ACTUAL TENSILE STRENGTH TO THE ACTUAL YIELD STRENGTH IS NOT LESS THAN 1.25. <br />AT HORIZONTAL REINFORCING. <br />D. SDs = 0.072 <br />E. SD1 = 0.055 <br />4. WELDED WIRE FABRIC SHALL CONFORM TO THE REQUIREMENTS OF ASTM A185. LAPS IN WELDED WIRE FABRIC <br />7. MINIMUM LINTEL, WHERE NOT NOTED ON PLANS, SHALL HAVE A MINIMUM OF (2) #5 CONTINUOUS HORIZONTAL BARS IN <br />F. SEISMIC DESIGN CATEGORY = A <br />SHALL BE MADE SUCH THAT THE OVERLAP, MEASURED BETWEEN OUTERMOST CROSS WIRE OF EACH FABRIC SHEET, <br />BOTTOM OF BOND BEAM OR LINTEL BLOCK AND SHALL BE GROUTED SOLID TO A MINIMUM DEPTH OF 24 INCHES. ALL LINTEL <br />IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 INCHES. <br />REINFORCING AND GROUT SHALL EXTEND 2 FEET MINIMUM PAST JAMBS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. <br />5. ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO <br />8. LAP REINFORCING 60 BAR DIAMETERS FOR GRADE 60. STAGGER LAP SPLICES A MINIMUM OF ONE LAP LENGTH. <br />CENTER OF STEEL, MINIMUM COVER FOR NON -PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS, <br />UNLESS NOTED OTHERWISE ON PLANS OR DETAILS: <br />9. MASONRY VENEER SHALL BE ATTACHED TO SUPPORTING WALL FRAMING WITH Y6" DIA. WALL TIES OR DOVETAIL -TYPE <br />METAL TIES OF EQUIVALENT STIFFNESS EMBEDDED INTO HORIZONTAL MORTAR JOINTS. MAX. VERTICAL SPACING OF TIES <br />EXPOSURE CONDITION: MINIMUM COVER: TOLERANCES (+/-): <br />SHALL BE 16". MAX. HORIZONTAL SPACING SHALL BE 24". TIES IN ALTERNATE COURSES SHALL BE STAGGERED. PROVIDE 9 <br />GA. WIRE REINFORCING IN HORIZONTAL MORTAR JOINTS AT 16" O.C. ENGAGE 9 GA. WIRE WITH WALL ANCHOR TIES. <br />CAST AGAINST AND <br />CONSTRUCTION JOINTS IN MASONRY VENEER WALLS SHALL BE LOCATED PER THE ARCHITECTURAL DRAWINGS. <br />PERMANENTLY EXPOSED <br />TO EARTH: 3" %" <br />10. HORIZONTAL JOINTS SHALL BE REINFORCED WITH 9-GAUGE TRUSS -TYPE JOINT REINFORCEMENT EQUAL TO "DUROWALL" <br />@ 16" O.C. <br />EXPOSED TO EARTH <br />OR WEATHER: <br />COLD FORMED STEEL FRAMING: <br />#5 AND SMALLER: 1X22" %" <br />1. ALL COLD -FORMED STEEL FRAMING SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH MANUFACTURER'S <br />#6 AND LARGER: 2" %" <br />RECOMMENDATIONS AND IN ACCORDANCE WITH THE LATEST EDITION OF "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED <br />STEEL STRUCTURAL MEMBERS" BY THE AMERICAN IRON AND STEEL INSTITUTE. <br />NOT EXPOSED TO WEATHER OR IN <br />CONTACT WITH THE GROUND: <br />2. STRUCTURAL DRAWINGS TYPICALLY SHOW ONLY THE PRIMARY STRUCTURAL FRAMING ELEMENTS OF THE SYSTEM. <br />ROOF SLAB: 1" Y" <br />CONTRACTOR SHALL PROVIDE ALL ACCESSORIES INCLUDING TRACKS, WEB STIFFENERS, BLOCKING, LINTELS, CLIP ANGLES, <br />STRUCTURAL SLABS & WALLS: X" Y" <br />REINFORCEMENTS, FASTENING DEVICES, BRACING, AND OTHER ACCESSORIES AS RECOMMENDED BY THE MANUFACTURER TO <br />BEAMS AND COLUMNS (PRIMARY <br />PROVIDE A COMPLETE FRAMING SYSTEM. <br />REINFORCEMENT, TIES, STIRRUPS <br />AND SPIRALS): 1Y" % " <br />3. STEEL FOR 12,14 AND 16 GA. STUDS AND JOISTS SHALL HAVE MINIMUM YIELD STRENGTH OF 50 KSI. STEEL FOR ALL 18,20 AND 25 <br />SLABS ON GRADE: 1y" X" <br />GA. STUDS AND JOISTS, ALL GAGES OF TRACK, ALL DIAGONAL TENSION STRAPS OR BRACES, AND BRIDGING SHALL HAVE MINIMUM <br />YIELD STRENGTH OF 33 KSI. STEEL SHALL BE GALVANIZED OR THOROUGHLY COATED WITH RUST INHIBITIVE PAINT AT ALL <br />6. LAP SPLICES OF REINFORCING STEEL IN ALL CONCRETE SHALL BE ACCORDING TO ACI 318 (CLASS B SPLICE), <br />LOCATIONS. <br />UNLESS NOTED OTHERWISE. STAGGER SPLICES A MINIMUM OF ONE LAP IN LENGTH. NO TACK WELDING OF <br />REINFORCING BARS ALLOWED. LATEST ACI CODE AND DETAIL MANUAL APPLY. PROVIDE BENT CORNER BARS TO <br />4. FASTENING OF COMPONENTS SHALL BE WITH SELF -TAPPING SCREWS OR WELDS. ALL WELDS OF GALVANIZED STEEL SHALL BE <br />MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL <br />TOUCHED UP WITH ZINC -RICH PAINT. ALL WELDS OF CARBON SHEET STEEL SHALL BE TOUCHED UP WITH PAINT. <br />WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. SPLICE BARS TOP BARS AT CENTER LINE OF SPAN AND <br />BOTTOM BARS AT THE SUPPORT IN SPANDRELS, BEAMS, GRADE BEAMS, ETC. UNLESS NOTED OTHERWISE. <br />5. ALL STUDS SHALL BE SECURELY SEATED FOR FULL END BEARING ON TOP AND BOTTOM TRACK. UNLESS NOTED OTHERWISE, <br />PROVIDE DOUBLE STUDS AT ALL JAMBS, CORNERS, INTERSECTIONS, AND BEAM BEARING. <br />7. ALL CONSTRUCTION JOINTS SHOWN ON THE DRAWINGS SHALL BE INCORPORATED IN THE STRUCTURE UNLESS <br />THEIR ELIMINATION IS APPROVED BY THE ENGINEER. ADDITIONAL CONSTRUCTION JOINTS REQUIRED TO FACILITATE <br />6. WALL STUD BRIDGING, AS RECOMMENDED BY THE STUD MANUFACTURER, SHALL BE INSTALLED TO PREVENT BOTH WEAK AXIS <br />CONSTRUCTION SHALL BE LOCATED AND DETAILED ON SHOP DRAWINGS. WHEN CONSTRUCTION JOINTS OTHER THAN <br />BENDING AND STUD ROTATION AT 4'-0" MAXIMUM INTERVALS. WALLS 8'-0" AND SHORTER SHALL HAVE A SINGLE ROW OF BRIDGING <br />THOSE SHOWN ON THE DRAWINGS ARE REQUIRED, THE REINFORCEMENT SHALL PASS CONTINUOUSLY THROUGH THE <br />AT MID -HEIGHT. IN ADDITION, BRIDGING SHALL BE PROVIDED AT ROOF LINES AND ELSEWHERE AS NOTED ON THE DRAWINGS. <br />JOINT AND A KEY SHALL BE PROVIDED FOR ADEQUATE SHEAR TRANSFER. <br />SOLID BLOCKING SHALL BE INSTALLED IN LIEU OF BRIDGING WHERE NOTED ON THE DRAWINGS. <br />8. ALL REINFORCING SHALL BE BENT COLD. BARS SHALL NOT BE STRAIGHTENED AND RE -BENT. FIELD BENDING OF <br />7. SCREWS SHALL BE SELF -TAPPING PAN HEAD, HEX HEAD, OR WAFER HEAD SHEET METAL SCREWS. A SCREW OF A LARGER <br />REBAR SHALL NOT BE ALLOWED UNLESS SPECIFICALLY NOTED OTHERWISE. <br />DIAMETER SHALL REPLACE SCREWS, WHICH ARE REMOVED, WHERE THE REPLACEMENT IS MADE INTO AN EXISTING HOLD. <br />REPLACE ALL SCREWS, WHICH STRIP OUT MATERIAL. SCREWS SHALL BE SPACED NO CLOSER THAN % INCH ON CENTER AND WITH <br />9. REINFORCING BAR SPACING SHOWN ON PLANS ARE AT MAXIMUM ON CENTERS, ALL BARS SHALL BE DETAILED AND <br />A MINIMUM FREE EDGE DISTANCE OFY2 INCH. CLIP ANGLES OR FLAT CLIPS USED FOR ATTACHMENTS SHALL BE 20 GA. MINIMUM, <br />PLACED PER CONCRETE REINFORCING STEEL INSTITUTE (CRSI) SPECIFICATIONS AND HANDBOOK. DOWEL ALL <br />UNLESS NOTED OTHERWISE. SIZE CLIP ANGLES AND FLAT CLIPS TO MAINTAIN MINIMUM SCREW SPACING AND EDGE DISTANCES <br />VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. <br />NOTED ABOVE. ALL SCREWS #8 AND LARGER SHALL HAVE A MINIMUM HEAD SIZE OF %6 INCH. <br />10. MECHANICAL SPLICE COUPLERS, FLANGE COUPLERS, THREADED COUPLERS, ETC. SHALL HAVE CURRENT ICBO <br />8. ALL WELDING SHALL BE PERFORMED BY WELDERS EXPERIENCED IN LIGHT GAGE, STRUCTURAL STEEL FRAMING WORK. <br />APPROVAL AND SHALL BE CAPABLE OF DEVELOPING 125% OF THE STRENGTH OF THE BAR. <br />00 <br />00 <br />mm <br />2222 <br />0 <br />�ti <br />z <br />It c <br />• <br />± <br />LL <br />w <br />Ww <br />LO <br />o <br />w <br />Z <br />co <br />0 <br />a <br />w <br />w <br />Z <br />w <br />m^ <br />w <br />F- <br />oCO <br />U- W <br />F- <br />►�- <br />w <br />w � <br />z <br />< <br />w_j <br />F-- <br />x w <br />J <br />U LL <br />V <br />: <br />§z <br />z <br />o m <br />0 <br />U <br />N 0 <br />z <br />W it �rZui x6 �cn <br />0 u- ZWF 0012 <3 <br />W C N <5V6ppg <br />L_ arc �dri° �6:) <br />z 3��=��z�zg�r <br />F zvs /�p<��4636-FZ5 <br />< rc<`V SLc izxZvr�LLv, <br />5 < 2Zl�r 6trJw ZVW <br />� Jig U� <br />w� m <br />Wo W_itCL FoIx-c <br />>m 0 <br />0. <br />Q <br />Im W <br />0 D . <br />�JLL <br />J of <br />w W m <br />>11IIIIIIIIIII�J=r- <br />LU J CL <br />m n/ < w l <br />I..1.. N CrD4 <br />m V <br />\' J 0 w <br />M � <br />r-.. 'm <br />0 <br />ISSUE BLOCK <br />CHECKED BY: ARM, BSVV <br />DRAWN BY: MRH <br />FILE NAME: SO-0-ZEPHYRHILLS-FL-GN <br />DOCUMENT DATE: 08-09-13 <br />GENERAL <br />NOTES <br />SHEET: <br />SO.0 <br />