MUA FAN INFORMATION - JOB,#536648 9 <br />FAN <br />UNIT <br />TAG <br />QTY <br />FAN UNIT MODEL # <br />BLOWER <br />H❑USING <br />MIN <br />DESIGN <br />ESP <br />RPM <br />MOTOR <br />HP <br />BHP <br />PHASE <br />VOLT <br />FLA <br />MCA <br />MOCP <br />WEIGHT <br />SONES <br />NO <br />CFM <br />CFM <br />ENCL <br />(LBS) <br />2 <br />MUA-2 <br />1 <br />EA-Al-15D <br />15MF-1-MOD <br />Al <br />- <br />1100 <br />0,500 <br />1299 <br />❑DP <br />0,750 <br />0,3280 <br />3 <br />208 <br />2.5 <br />3,2A <br />15A <br />265 <br />13.4 <br />FAN #2 EA-Al-15D - SUPPLY FAN (KSF-1) <br />1, UNTEMPERED SUPPLY UNIT WITH 15' MIXED FLOW DIRECT DRIVE FAN IN SIZE #1 HOUSING, <br />2. INTAKE HOOD WITH EZ FILTERS. <br />3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT. <br />4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 1 UNTEMPERED DIRECT DRIVE AHUS, <br />5. GRAVITY BACK DRAFT DAMPER, 16' WIDE X 18' HIGH, STANDARD GALVANIZED CONSTRUCTION, 1 1/4' REAR FLANGE, FOR SIZE 1 <br />UNTEMPERED FAN HOUSING (5181). <br />6. MIAMI DADE IMPACT AND WIND LOAD CERTIFICATION +30 / -130 PSF - MIAMI DADE COUNTY PRODUCT CONTROL APPROVED, <br />FLORIDA BUILDING CODE APPROVAL, ROOF MOUNT EXHAUST CURBS UP TO 20' HIGH MUST BE 16 GAUGE ALUMINIZED. <br />7. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER SECTI❑N). <br />8.2 YEAR PARTS WARRANTY <br />wN❑TEt SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS, A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED <br />DOWNSTREAM OF UNIT DISCHARGE AS ❑UTLINED IN AMCA PUBLICATI❑N 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST <br />BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD <br />NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT, SYSTEM EFFECT WILL <br />DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW, D❑ NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY, FAILURE <br />TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT• <br />SUGGESTED STRAIGHT DUCT SIZE IS 14' x 14', <br />LIFTING LUG, <br />3 <br />20' EQUIPMENT CURB. <br />2 1' <br />ROOF OPENING 2' SMALLER THAN CURB DIMENSION• <br />7 L <br />13 <br />6 3/8' <br />DI M% /rn T1 T C1 rli IAf9rr <br />FOR FIELD <br />WIRING. <br />32 1/8' <br />AIRFLOW, <br />SERVICE <br />DISCONNECT <br />29 3/4' SWITC <br />BLOWER/MOTOR <br />ACCESS DOOR <br />24' SERVICE <br />CLEARANCE REQ. <br />MINIMUM <br />STRAIGHT <br />DUCT <br />PER AMCAA <br />�~ 29'- <br />I 1 <br />I 1 <br />MIN, 14' <br />76 1/2' <br />AIRFL❑W, <br />FOR REFERENCE ONLY !ll <br />ELECTRICIAN NOTES <br />All Hood/Fan/EMS/UDS/PCU electrical <br />connections and interconnections to <br />be provided and installed by <br />Electrician, Electrician to provide, <br />install, and land wiring between hood <br />Lights, hood temp sensors, remote <br />Ansul system microswitches, and any <br />other component requiring an <br />electrical connection to the <br />Captive -Aire electrical package, <br />Failure by the Electrician to make ALL <br />required electrical connections and <br />interconnections will result in the <br />electrical controls not working <br />properly. Any loss or failed test as <br />a result of electrical controls not <br />working properly is the responsibility <br />of the Electrician, <br />Light bulbs for kitchen hoods to be <br />provided and installed by electrician, <br />GENERAL NOTES : <br />1. ELECTRICAL HOOK-UP TO CAS MOTOR CONTROLS <br />(MOTOR STARTERS, FAN SWITCHES, <br />FAN DISC❑NNECTS, RELAYS, ETC. ) BY OTHERS, <br />2. FIRE CHASE BY OTHERS, IF REQUIRED, <br />3. ALL PHASES OF INSTALLATION SHALL COMPLY <br />WITH NFPA 96. <br />4. WRITTEN MEASUREMENTS HAVE PRECEDENCE <br />OVER SCALE. <br />5. PROVIDE CLEAN❑UTS IN EXHAUST AIR <br />DUCTS AS INDICATED TO ALLOW CLEANING <br />AT ALL BENDS AND HORIZ❑NTAL RUNS, <br />6. UNLISTED EXHAUST DUCT TO BE 16 GA. GAV <br />STEEL ALL SEAMS AND J❑INTS TO HAVE A LIQUID <br />TIGHT CONTINU❑US EXTERNAL WELD, <br />7. FAN TO HAVE A MINIMUM OF 10 FT, OF <br />CLEARANCE FROM THE OUTLET TO ADJACENT <br />BUILDINGS, PROPERTY LINES, AIR INTAKES <br />OR 3 FT, VERTICAL CLEARANCE PER NFPA96 <br />8. H❑RIZONTAL EXHAUST DUCT TO SLOPE NOT LESS <br />THAN 1/4' PER FOOT TOWARD HOOD FOR DUCT <br />LESS THAN 75' LONG. <br />1' PER FOOT SLOPE FOR DUCT LONGER THAN 75' <br />9. HOOD TO OVERHANG COKING EQUIPMENT 6' <br />ON ALL OPEN SIDES, <br />10,EXHAUST DUCT TO BE PROTECTED FROM <br />COMBUSTIBLES PER NFPA96 AND LOCAL CODE, <br />11,BUILDING PRESSURE SHALL NOT EXCEED 0.02' <br />WATER COLUMN AT EXTERI❑R DOORS. <br />12.KITCHEN SHALL BE BALANCED TO BE NEGATIVE <br />WITH RESPECT TO THE DINING ROOM, <br />N <br />0 <br />I <br />0 <br />REVISIONS <br />E <br />8 <br />.� <br />c <br />to <br />ill <br />W <br />0 <br />00 <br />cM <br />6 <br />M <br />00 <br />Uj <br />z' <br />O <br />s <br />a' <br />ACD <br />M <br />M <br />U_ <br />cd <br />a <br />E <br />ca <br />0 <br />Uj <br />CO <br />OI <br />x <br />2LO <br />Ui <br />S <br />S` <br />Q <br />W <br />Ln <br />f`J <br />I <br />M <br />� <br />O <br />> <br />C <br />S <br />V) <br />L <br />(:5 <br />>1 <br />4- <br />S <br /><Z5 <br />M <br />C <br />CU <br />M <br />Q� <br />N <br />) <br />DATE: 4/25/2022 <br />DWG.#: <br />5366481 <br />DRAWN <br />Y: celso,saenz <br />SCALE: <br />3/4" = 1 '-0" <br />MASTER DRAWING <br />SHEET NO. <br />3 <br />11111111 <br />MCO 0) <br />W V) 4 <br />LLJ (14 Co <br />N 4k <br />Lj U <br />' 0 3 M -J <br />lL <br />Y n W <br />Lt1 o <br />Z <br />pUM�, <br />� Z <br />/ � J <br />V Q a=W 3 <br />W <br />Q <br />a - <br />Go <br />v <br />� <br />L <br />_o <br />Jj <br />C1 Q <br />a <br />$ <br />$ <br />ld <br />c > <br />� c <br />� <br />gos <br />1� <br />x <br />Z <br />W <br />L <br />Q <br />cl <br />`o~Qco <br />0 <br />o�wQ <br />4-) <br />In <br />J <br />� <br />o�m0 <br />O <br />Q <br />V�1WJ\ <br />ts)f <br />Q <br />Q <br />V <br />0 <br />� <br />0 <br />Q) <br />C� <br />❑L <br />0 <br />l�l <br />LU <br />E-:� <br />N <br />W <br />ti <br />A E•� <br />i1+ <br />No 56189 <br />►1 • STATE OF <br />o P <br />tS��NA'. <br />Date: 4. 25. 22 <br />Checked by: MI. <br />Drawn: '1'J/KB <br />Job: 21-042 <br />Sheet <br />M006 <br />