ELECTRICAL NOTES <br />1. ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH ARTICLES <br />250.56 AND 250.58 OF THE NATIONAL ELECTRICAL CODE (NEC), CURRENT EDITION. <br />2. WHEN WATER HEATERS ARE INSTALLED THEY SHALL BE PROVIDED WITH READILY ACCESSIBLE <br />DISCONNECTS ADJACENT TO THE WATER HEATERS SERVED. THE BRANCH CIRCUIT SWITCH OR <br />CIRCUIT BREAKER SHALL BE PERMITTED TO SERVE AS THE DISCONNECTING MEANS ONLY <br />WHERE THE SWITCH OR CIRCUIT BREAKER IS WITHIN SIGHT FROM THE WATER HEATER OR IS <br />CAPABLE OF BEING LOCKED IN THE OPEN POSITION. <br />3. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS ADJACENT TO <br />THE EQUIPMENT SERVED. A UNIT SWITCH WITH A MARKED "OFF" POSITION THAT IS A PART OF <br />THE HVAC EQUIPMENT AND DISCONNECTS ALL UNGROUNDED CONDUCTORS SHALL BE PERMITTED <br />AS TFE DISCONNECTING MEANS WHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY <br />A READILY ACCESSIBLE CIRCUIT BREAKER. <br />4. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING OF THE MAIN BREAKER MUST <br />BE DESIGNED AND VERIFIED AS BEING IN COMPLIANCE WITH SECTION 110-9 OF THE NEC. <br />5. THE MAIN ELECTRICAL PANEL AND FEEDERS ARE DESIGNED AND INSTALLED BY OTHERS. <br />6. BUILDING PIPING SYSTEMS SHALL BE BONDED IN ACCORDANCE WITH ARTICLE 250.104 <br />OF THE NATIONAL ELECTRICAL CODE (NEC), CURRENT EDITION. <br />7. FIRE ALARM SYSTEM SHALL BE WIRED TO MECHANICAL SYSTEM WITH AUTOMATIC SHUTDOWN. <br />8• ALL WIRING SHALL BE COPPER WITH THWN / THHN INSULATION INSTALLED IN APPROVED RACEWAYS. <br />9. CONTRACTOR TO CONNECT ALL FIXTURES AND APPLIANCES. <br />10. CONTRACTOR TO HAVE VALID FLORIDA LICENSE TO DO ELECTRICAL WORK. <br />11. ALL ELECTRICAL TO BE ABOVE FLOOD ELEVATION. <br />12. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES TO AVOID CONFLICTS. <br />13. ELECTRICAL CONTRACTOR SHALL SECURE ALL PERMITS AND INSPECTIONS AS REQUIRED BY <br />STATE AND LOCAL CODES AND ORDINANCES. <br />14. UPON COMPLETION OF WORK, ELECTRICAL CONTRACTOR SHALL PROVIDE TO THE OWNER CERTIFICATES <br />OF FINAL INSPECTIONS AND APPROVALS FROM AUTHORITIES HAVING JURISDICTION. <br />15.ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL WORK FOR ONE YEAR FROM THE DATE <br />OF FINAL ACCEPTANCE BY THE OWNER. <br />16. USE FLEXIBLE CONDUIT FOR SHORT FINAL CONNECTIONS TO VIBRATING EQUIPMENT SUCH AS MOTORS AND <br />TRANSFORMERS. LIQUID -TIGHT FLEXIBLE CONDUIT SHALL BE USED IN DAMP AND WET LOCATIONS. <br />17• CONDUITS INSTALLED IN CONCRETE SLABS SHALL NOT BE LARGER THAN 1/3 OF THE SLAB THICKNESS. <br />18. PROVIDE CABLE SUPPORTS IN ACCORDANCE WITH ARTICLE 300 OF THE N.E.C. <br />19. PROVIDE EXPANSION FITTINGS IN CONDUIT RUNS THAT CROSS STRUCTURAL EXPANSION JOINTS. <br />20. PROVIDE APPROVED FIRE STOPPING MATERIALS AT ALL PENETRATIONS THROUGH FIRE <br />RATED FLOORS AND WALLS AS REQUIRED BY ARTICLE 300-21 OF THE N.E.C. <br />21. ALL PANELS SHALL HAVE TYPWRITTEN CIRCUIT DIRECTORIES MOUNTED ON THE INSIDE OF <br />THE PANEL DOOR. <br />22. PANELS SHALL BE SUITABLE FOR THE SERVICE RATING AND THE A.I.C. RATING INDICATED <br />ON THE PANEL SCHEDULES. <br />23. ALL BREAKERS SHALL BE FULL SPACE, INDIVIDUAL FRAME TYPE. PIGGYBACK OR TANDEM <br />BREAKERS SHALL NOT BE ALLOWED. <br />LIFE <br />SAFETY LEGEND <br />LIGHTED EXIT SIGN WITH <br />EXIT <br />EMERGENCY LIGHT <br />FE <br />FIRE EXTINGUISHER WHERE <br />SHOWN SEMI —RECESSED WHITE <br />CABINET WITH BUBBLE PLEX. <br />FRONT, 5 LB ABC EXTINGUISHER. <br />MT. WITH PULL HANDLE MAX. <br />42" ABOVE FLOOR <br />ELECTRICAL LEGEND <br />8 DUPLEX OUTLET <br />240V. OUTLET <br />GFI GROUND FAULT INTERRUPT OUTLET <br />® ELECTRICAL PANEL <br />OCCUPANCY LOAD AND PLUMBING COUNT DATA: <br />UNIT 181 & 82: <br />NEW 240V.— <br />RECEPTACLES <br />ON TIMERS <br />NEW <br />COMPRESSORS <br />NEW 60 AMP <br />SUB —PANEL B 16 <br />WIRE 1 /0, 220V. <br />\— CONTRACTOR <br />TO INSTALL <br />COMPRESSED <br />AIR LINES TO <br />NEW MACHINES <br />NEW EXHAUST <br />WALL FAN <br />EXISTING 225 AMP <br />MAIN PANEL <br />120/240V., 10 <br />GFI <br />IT <br />0 <br />OCCUPANCY - B, BUSINESS <br />AREA - 2,131 S.F. <br />OCCUPANT LOAD - 1/100 S.F. GROSS = 22 <br />PLUMBING FIXTURES <br />WATER CLOSETS - 1 /25 OCC. = 1 REQ'D - <br />LAVATORIES - 1 /40 OCC. = 1 REQ'D� <br />DRINKING FOUNTAINS - 1 /100 OCC. = 1 REQ'D <br />NOTE: <br />ELECTRICAL CONTRACTOR TO <br />PROVIDE REQUIRED CIRCUIT <br />DIAGRAMS, PANEL <br />CALCULATIONS, ETC. <br />ELECTRICAL PLAN <br />FE) I I EXIT <br />% MAXIMUM TRAVEL DISTAN!"E <br />' TO EXIT = 74'-0" <br />OCCUPAN . LOAD/'LIF'E <br />SAFE91"Y PLAN <br />RUSSELL <br />R001RIGUEZ <br />9 South Pegasus Me. <br />Clearwater, Florida <br />33765 <br />Tel: (727) 492--1468 <br />To N CWK ALL ORTAU MO MtLRIMM <br />OLIOIM"Im am Tm ORNAVOKA0M <br />AK MZ!/A MW MR VMM ALL <br />r v 0 III M Wow fm ANY <br />OR TO TW LaMMDWA�O°NIm ieNTf Or AW1 <br />4661 33N/g S <br />r r� <br />y W T <br />a a t� <br />" <br />< M Z 77A .19 <br />0 A. <br />5 <br />SUCCESSI�'�\' <br />O0-4 <br />� <br />A <br />> <br />0 <br />W <br />� <br />A <br />� <br />O <br />� <br />F-4 <br />P <br />W <br />E. 4 <br />rn <br />Lo <br />M <br />(�� ;. <br />PL1 <br />Vn <br />L\I <br />z <br />i <br />DRAWN BY <br />i RCR <br />REVISION <br />DATE <br />02 13 12 <br />SCALE <br />AS NOTED <br />JOB NO. <br />2K 12009 <br />SHEET <br />A 2 <br />OF � SHEETS <br />