Laserfiche WebLink
51GNAGE DETAILS <br />SCALE: T IT' <br />TYPICAL SIGN TYPICAL SIGN TYPICAL SIGN <br />FOR TOILETS FOR TOILETS AT STAIRS <br />MEN WOMEN EXIT STAIRS <br />NOT USED NOT USED NOT USED <br />T T T T <br />ADA—DOOM CLEARANCE <br />NOTE: NOTE: <br />X= 1 2" IF BOTH CLOSER X= 1 2' IF BOTH CLOSER AND LATCH ARE <br />AND LATCH ARE PROVIDED <br />PROVIDED (")=48" MIN. IF BOTH CLOSER AND LATCH ARE NOTE: <br />PROVIDED (")=48" IF CLOSER IS <br />r <br />PROVIDED <br />T — — � <br />I I 1 F T — — — — r — — — — <br />1I I 1 1 41 I I I <br />I I I i I <br />1 1 PUSH 51DE1 PUSH SIDE PUSH 51D <br />%PU PULL 51DE PULL SID PULL SID <br />L — — — — — <br />i—-j <br />FRONT APPROACH HINGE APPROACH HINGE APPROACH LATCH APPROACH <br />MANEUVERING CLEARANCE AT MANUAL SWINGING DOOR <br />H.C. PARKING <br />C = - <br />s <br />c <br />VAN ACCESSIBLE <br />PLAN <br />Xx <br />e <br />VAN <br />CCE551BL <br />PARKING <br />ALTERNATE VAN ACCE551BLE PLAN <br />VAN <br />ACCESSIBLE <br />PARKING'\\\X <br />TYPICAL ACCESSIBLE PARKING <br />PLAN <br />ARKING SIGN It HC <br />3OL5 (SEE DETAILS) <br />NOTES: <br />1 . VAN SPACES FOR EVERY SIX OR FRACTION OF <br />SIX ACCE551PLE PARKING SPACES, AT LEAST <br />ONE SHALL BE VAN ACCESSIBLE PARKING <br />SPACE <br />2. REFER TO ICC;AN51 A 1 1 7. 1-2003 FOR HC <br />PARKING REQUIREMENTS AT HOSPITAL <br />OUTPATIENT, REHAB, t PHYSICAL THERAPY <br />FACILITIES <br />3, SURFACE SLOPES OF HC PARKING SPACES SHALL <br />BE 1 :48 OR L55 IN ALL DIRECTIONS <br />HC <br />PARK <br />8" DIA. <br />1 2"x 18" HC <br />PARKING SIGN 2 COATS Of <br />VAN <br />ACCESS 8 <br />TRAFFIC <br />t5 <br />1 2"xG" VAN <br />ACCESSIBLE SIGIN_ <br />,,--PAVING <br />p <br />14" R. <br />4" WIDE BLUE <br />PAINT LINES <br />TYP. ACCESSIBILITY <br />SIGN DETAIL HANDICAP PARKNG SYMBOL <br />SCALE: NT5 <br />SCALE: NTS <br />TYPICAL REACH RANGES <br />-F <br />UNOBSTRUCTED FOKW.AKD REACH <br />OBSTRUCTED HIG1 FORWARD REACH <br />FF <br />TYPICAL SIGN <br />AT STAIRS <br />IN CASE t�i <br />OF FIRE <br />DO NOT USE <br />ELEVATOR <br />USE STAIRS, <br />ACCESSIBLE <br />ENTRANCE <br />NOT USED NOT USED NOT USED <br />T n T <br />STAIR D ETA I LS <br />ETURN <br />12'. <br />Tr <br />m EXTENSION I ANDRAIL GRIPS MUST BE <br />ET MI I - 1/4"-2", OUTSIDE DIA. <br />-1 /2" MIN. CLEAR SPACE <br />I " (MIN) TREAD BETWEEN HANDRAIL AND WALL <br />7" (MAX) RISER UPPORT 1ANDRAIL FROM <br />12". <br />MIN. <br />I " (MIN) TREAD <br />7" (MAX) RISER <br />STAIRS € HANDRAILS <br />BELOW SO GRIPPING SURFACE <br />I5 NOT INTERRUPTED <br />SECTION <br />r <br />XTfN510N DIMEN51ON <br />ND OF HANDRAILS <br />MUST RETURN <br />SMOOTHLY INTO A <br />WALL, FLOCK, OR P05T <br />PLAN <br />RAMPS AND STAIRS <br />SCALE: 6/6211 <br />LANDING <br />1 :48 SLOPE <br />RAMP RU N <br />1:12 <br />SLOPE LANDING <br />WPM I :48 SLOPE <br />(MAX) <br />RAMP <br />UN 1:12 <br />SLOPE <br />(MAX) <br />FF <br />10 <br />UNOBSTRUCTED 51DE REACH <br />RAMP RUN 1: 12 <br />SLOPE (MAX) <br />LANDING <br />1:45 SLOPE <br />MAX <br />c <br />C <br />a <br />i 2". IN. <br />EXTENDED <br />SURFACE <br />CURB OR <br />BARRIER <br />OPTION <br />I <br />(MIN) <br />N <br />GRADE BADE <br />GRADE OPTION <br />RAMP EDGE PROTECTION <br />1101 I "-24" <br />MAXIMUM <br />XX OCCUPANTS <br />NOT USED <br />T <br />r <br />RESTROOM <br />n <br />TYPICAL MOUNTING HEIGHTS <br />SCALE: 1/2" = 1'-0" <br />ANY OBSTRUCTION <br />SHALL BE 42" MIN. <br />FROM DOOR 51DE OF <br />STALL <br />1 2" MIN. FOR <br />CHILDREN ONLY <br />UNITS <br />TYPICAL ACCESSIBLE TOILET <br />STALL AND FIXTURES <br />TYPICAL CLEAR SPACE <br />SCALE: 1 /4" = 1'-0" <br />q� I <br />J <br />S . _ 30"x48" CLEAR <br />FLOOR SPACE AT <br />LAVATORY <br />LAV CLEARANCES <br />GO'x5G" CLEAR FLOOR <br />SPACE ATTOILET (DOORS <br />SHALL NO- SWING INTO <br />—CLEAR FLOOR SPACE <br />HC TOILET CLEARANCES <br />Biohazard. <br />Authorized <br />personnel only. <br />i u <br />cC. w." G. <br />AMBULATORY <br />WATER CLOSET ACCESSIBLE <br />URINAL <br />2'-G" <br />(MIN) <br />z 30"x48" CLEAR FLOOR SPACE <br />AT URINAL (3G'x48" IF URINAL <br />IS INSTALLED IN AN ALCOVE <br />q I 12 OVER 24" DEEP, SEE SEC. <br />0'1QJ 10 305.7) <br />EDOz <br />'0/ I� <br />U JL _ J <br />HC URINAL CLEARANCES <br />30"x52" CLEAR <br />FLOOR SPACE AT <br />_ LAVATORY <br />GO"xGO" CLEAR FLOOR <br />SPACE AT TOILET <br />I I 1 2" HIGH TOE CLEARANCE <br />/ EXTENDED 8" BEYOND <br />FRONT PARTITION AND AT <br />LEAST ONE SIDE <br />PARTITION OF TOILET <br />FLUSH HANDLE <br />TO BE LOCATED <br />ON OPEN 51DE <br />51GN <br />MOUNTING LOCATION <br />SUALF 2 = - <br />IF ADJACENT SIDELIGHT, <br />........... <br />------. MOUNT ON GLA55 WITH A <br />----- <br />i BLANK MATCHING PANEL <br />ON OPPOSITE 51DE OF <br />GLAZING. <br />ii <br />i i MOUNT SIGN ON <br />i i LATCH SIDE OF <br />(I <br />DOOR <br />PAPER TOWEL ACCE55IDL <br />DISPENSER E LAV <br />3'-0" <br />Q <br />ACKIWALL <br />O <br />m <br />N <br />c <br />30x48" CLEAR <br />I <br />O <br />FLOOR SPACE @ <br />J <br />HCSHOWER <br />— — _ <br />4'-0" <br />—n <br />STALL <br />IU <br />15' (MIN) <br />z0 m <br />GRAB BAR <br />IN v� <br />�O� <br />\� <br />_ <br />_ <br />con <br />4 <br />U O <br />C) <br />0 co <br />cn z n- m O <br />C) <br />O U <br />=- <br />HC SHOWER CLEARANCES <br />DISPENSER <br />FIRE ALARM <br />LU <br />Q <br />I <br />I � I <br />I ; I <br />�—T <br />CENTERED ON <br />RAISED <br />CHARACTERS <br />O <br />Z <br />05-04-2022 <br />SANITARY <br />NAPKIN <br />DISPOSAL <br />,�� O F FL09i <br />P. Ap 9 <br />John P Digitally signed • ; - * - • <br />AR%252 r <br />by John P Adam .. <br />Date: 2022.05.04 A <br />Adams 17:12:07-04'00' <br />;_ <br />U <br />Q W Q f1 (0 <br />qe J _ <br />C <br />mco � <br />Q Q Q ` v <br />U_o • <br />C Z c h <br />cc <br />C p cocc <br />N <br />m N L J <br />CID i 17 LL <br />G M 0 <br />d Z <br />CD <br />D i <br />Q O <br />v_i ui <br />O <br />m Q <br />n 0 <br />Z <br />. g <br />� F <br />z � <br />O <br />Y o <br />0 <br />v 00 <br />i J <br />W <br />T� <br />L Q <br />rrnn <br />W m <br />0 <br />rV <br />N <br />H <br />V <br />W <br />dCL <br />H <br />Y <br />ACCE551 B 1 LITY NOTES z <br />aIRT <br />_ rn <br />M <br />V M <br />J <br />LL <br />I . THESE DIMENSIONS ARE REQUIREMENTS FOR MANEUVERING AREA AND FORTHE � Z J <br />LOCATION OF FIXTURES, DEbICE5, AND TOILET ACCESSORIES. CONFLICTS WITH THE W O J <br />DRAWING DETAILS OR DIMENSIONS SHALL 13E BROUGHT TO THE ATTENTION OF THE C <br />ARCHITECT. G <br />> V, } <br />2. NOT ALL OF THESE DIMENSIONS OR DETAILS MAY BE APPLICABLE TO THIS PROJECT. V l Q <br />w <br />THI5 INFORMATION 15 PROVIDED FOR REFERENCE PURPOSES. J m Q N <br />� <br />3. IF NOT DETERMINED OTHERWISE, STANDARD ADA VEACH RANGE' I5 15"-48"'. j V) WQ <br />4. ALL PIPING FOR ACCESSIBLE LAV5, INCLUDING DRAIN PIPING UNDER COUNTER TO BE + Z Q J <br />INSULATED. Cie <br />Q O <br />5. ACCE551BLE SIGNAGE SHALL HAVE 18" WIDE x 18" DEEP CLEAR FLOOR SPACE (SEE °0 <br />Uj <br />ANSI A 1 1 7. 1-2009 FOR ALTERNATE SIGN LOCATION).Lu Q <br />G. ®DENOTES FIXTURES TO MEET THE ACCESSIBIUTY REQUIREMENTS OF PERSONS 0 U <br />WITH DISABILITIES. �J W O m <br />Ln <br />7. HORIZONTAL SRAB BARS SHALL BE PROVIDED ACROSS THE CONTROL WALL � ON THE W Z U n <br />BACK WALL TD A POINT 18" FROM CONTROL WALL OF SHOWER. <br />Z APRIL 1, 2022 <br />8. VERTICAL GRAB BAR, 18" (M N) IN LENGTH, SHALL BE PROVIDED ON THE COINTKOL END WALLL 3" TO O <br />G" ABOVE THE HORIZONTAL GRAB BAR * 4" iMAX) INWARD FROM FRONT EDGE OF SHOWER. <br />9. RAMP It LANDING GRO55 SLOPES 1 :48 MAX.. V <br />10. HANDRAIL5 REQ. AT RAMPS 'N/ G" OR MORE RISE. <br />1 1. EDGE PROJECT AT RAMPS SHALL BE REQUIP-D WHERE DROP-OFF ALONG EDGE IS <br />GREATER THAN 1/2" WITHIN 10" OF RAMP EDGE. Z <br />12. 42" HIGH GUARDRAILS 5HAL_ BE PROVIDED WHERE EDGE DPOP-OFF GREATER THAN V <br />30 INCHES. <br />13. CONTRACTOR TO SUPPLY AND INSTALL SIGNS AS SHOWN ON THIS SHEET, AS NOTED <br />ELSEWHERE ON DRAWINGS, AND AS REQUIR=D BY ANY OTHER CODE ORAGGENCY <br />HAVING JURISDICTION. A02 <br />G:\2020\2001 GA\Dwg\DWG\arch\2001 GA - PP5WCF - UnivPIazaChncPcno (RI 8).rvt COPYRIGHT 2020 - KTH ARCHITECTS, INC. <br />-- <br />I , 1. 1 , 1 w c.,111. .i: n..uiei „, i 11--]-1•I F 1 I -� -f— I - <br />I <br />