Laserfiche WebLink
101 ELECTRICAL PLAN <br />SCALE:3/16" ■ I'-0" <br />MODEM <br />Y VENT <br />HOLE <br />SECURITY CONT. PIANO <br />MONITOR HINGES <br />_i• <br />(DI OMICE ELEVATION DETAIL <br />SCALE:3/6" ■ 1'-0" <br />mu <br />102" AFG 13 <br />1\A-2 <br />WP1GF1 <br />3 <br />AIRS <br />02 <br />---------------------------------------------------------------------- OOP DETECTOR <br />SEE WIRING DETAIL 5 THIS SHEETO <br />455"AFF �ZoR <br />EMA NEMA 6-30R <br />_ 80" AFF 12"AFF <br />3 <br />1 ■ 54"AFF ■ Cm -- -- MENUBOARD"G220 <br />DRIVE "P300 ■ 1811� 0010 4010 "D81 <br />'IC31 TLRU "C20 00 <br />C IG 12 16 0 "D20 ITK GLEN <br />A-18 � <br />C 24'AFF, 54"AFF I \\ 3 <br />13 �_2 11�5 NEMA 15-30R ra u SPEAKERBOX "Q21 <br />C G 1 II <br />to C 12 A� �$10 44 0 16"AFF EXISTING <br />A-2 IG i0 - 8 ■ "D 0 NEMACOOLER �EZER SEE WIRING DETAIL 5 THIS SHEETO <br />� 9 ■ ■ -30R <br />�10.4PD 5 10 ROOF MOUNTED ICE MAKER \ <br />OIWIOAPD 4 EF-2 +Fl 1 "AISU6 D_11 ANSUL -- REMOTE CONDENSER UNIT •\ <br />(, )%4I0.4PD <br />30 NEMA- 12"AFF-3 6010AFF "KI0 30 i ,\. <br />6-15R J40 rR I NF I \ <br />O16 I "P20 ~■ 92 4 p-15 9 OR D-34 I S L I P1REP - - - - `\% <br />\30 �A- ■ 94 O 8 p-19 14 D 15 � \% <br />SALES 2/0 L6-30R/ ■ 92 Imt ' <br />_ _ RTLI-2f <br />AREA I NEMA- © "D93 "A54 B T `� <br />` <br />104 '%tbbP20 A <br />6-15R 54"AFF "A4411.4 9 A-2 31 <br />-1 162/@- -- - �. <br />LEI <br />R I 12 A -IS - MEN S � C <br />S �� <br />,I ►-� TOILET I_� <br />i <br />ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP RECEPTACLES INSTALLED <br />IN KITCHEN AND SERVING AREAS SHALL HAVE GROUND FAULT CIRCUIT <br />INTERRUPTER PROTECTION FOR PERSONNEL IN ACCORDANCE WITH <br />ARTICLE 210.8 (B) OF THE NATIONAL ELECTRICAL CODE. <br />0 <br />r FINISHED FLOOR <br />. d , <br />a ° <br />END CAP <br />A-6 A-8 <br />98"AFF <br />66 <br />86"AFF <br />BRUSH <br />IG IG IG A-10 <br />ALUM. PULLS 14"AFF <br />A-10 16 - A-6 <br />O 2 DATA PORTS <br />A-12 A-12 A-14 A-14 �'f A211 AFF <br />IG IG I�T <br />2 DATA PORTS kT <br />I TELEPHONE PO <br />RIGID STEEL CONDUIT <br />/; <br />►� OFFICE PREVIEW BOARD <br />A-3 <br />ICeOR. <br />I SSBE DETAIL , <br />l THIS SHEET I A-21 <br />-� �- FOR DEVICE61 <br />!L L IN THIS AREA <br />-�- - - - - 6 ISTING <br />44_EK_ <br />13 EL A <br />A-9 EXISTINGp PANEL H <br />DRY STORAGE <br />XISTING <br />18 PANEL C <br />TOILE IFgTpRAQE <br />IG i EXISTING <br />EXISTING PANEL WATER HEATER EXISTING MDP O <br />j 4K42 <br />EXISTING <br />j t PANEL <br />METER EXISTING <br />EXISTING TO REMAIN 84" AFF <br />WATER HEATER <br />CONTROLS RECEPTACLE C-33 <br />TYPE FS BOX 4 FSK COVER <br />AS REQUIRED FOR RECEPTACLE <br />REMOVE PLUG 4 INSTALL 3/4" <br />RIGID STEEL NIPPLE <br />CONDUIT COUPLING 4 COUNTER <br />SUNK CLOSE PLUG SET. FLUSH <br />WITH FINISHED FLOOR DURING <br />CONCRETE POUR. <br />I d <br />CAP END UNLESS FEEDING <br />ADDITIONAL OUTLETS <br />KITCHEN FLOOR BOX OUTLET DETAL <br />N.T.S. <br />CEILING GRID-J <br />WIRELESS DRIVE-THRU <br />CENTER MODULE <br />(WALL MOUNTED) -� <br />DETECTOR <br />- FIN. FLOOR <br />�- V CONDUIT <br />SIGNAL 4"x4" J-BOX <br />PROVIDE STAINLESS <br />STEEL COVER PLATE <br />W/ 3/4" BUSHING <br />HOLE FOR SIGNAL <br />OUTLET BOX" <br />__-A-16 <br />120 VOLT DUPLEX <br />4"x4" J-BOX <br />COUNTERTOP <br />3/4" CONDUIT TO <br />SPEAKER POST. <br />VERIFY LOCATION <br />O DRIVE THFaJ AUDIO DETAIL <br />SCALE: N.T.S. <br />E.C. SHALL CONNECT <br />G.C. PROVIDED DOOR <br />FLY FAN <br />E.C. SHALL INSTALL <br />AND WIRE-G.C. <br />PROVIDED MICRO <br />SWITCH IN INDOOR <br />FRAME FOR ON/OFF <br />CONTROL OF DOOR <br />FLY FAN <br />KITCHEN <br />EQUIPMENT <br />SCHEDULE <br />ITEM NO <br />QTY <br />DESCRIPTION <br />AMP <br />KW <br />HP <br />VOLTS <br />PH <br />DIRECT <br />PLUG <br />CIRCUIT <br />MANUFACTURER <br />MODEL <br />A18.U6 <br />1 <br />Fryer Battery, 6-18", Gas <br />8.5 <br />1/4 <br />120 <br />1 <br />X <br />H-1 <br />Ultrafryer Systems <br />B-P20-18-6-CFS-U23 <br />A31 <br />1 <br />Marinator - reduced height) <br />5.0 <br />115 <br />1 <br />X <br />A-21 <br />Falcon <br />FFM-1 67-365 <br />A47.4 <br />1 <br />Ice Batter / Sifter Table, 4 Pans, 100" <br />2.3 <br />.3 <br />115 <br />1 <br />X <br />A-19 <br />Kitchen Equip. Supplier <br />CUSTOM <br />A54 <br />1 <br />Freezer, Upright <br />12.0 <br />1/2 <br />115 <br />1 <br />X <br />A-17 <br />Delfield <br />6125XL-S <br />B10 <br />1 <br />Oven, 1/2 Size, Double Deck Convection, Elec. <br />2 24.0 <br />2 6 <br />208 <br />3 <br />X <br />D-8,10,12 , D-14,16,18 <br />Blodgett <br />2-CTB <br />B60 <br />1 <br />Refrigerator, Upright <br />12.0 <br />1/3 <br />115 <br />1 <br />X <br />A-15 <br />Delfield <br />6025XL-S <br />B65 <br />1 <br />1 Biscuit Holding Unit Optional <br />8.3 <br />1.0 <br />120 <br />11 <br />Ix <br />C-31 <br />Kitchen Equip. Supplier <br />CUSTOM <br />C10.27 <br />1 <br />REFRIGERATOR, SANDWICH UNIT <br />6.5 <br />1/5 <br />115 <br />11 <br />X <br />C-16 <br />Delfield <br />4427-6 <br />C20 <br />1 <br />Toaster, Vertical Contact <br />13.0 <br />1.5 <br />115 <br />1 <br />X <br />C-14 <br />Prince Castle <br />297-T20 <br />C30 <br />1 <br />Product Holding Unit Optional <br />4.5 <br />0.545 <br />115 <br />1 <br />X <br />C-18 <br />Hatco <br />GRKW <br />D20 <br />2 <br />Microwave Oven <br />20.0 <br />4.0 <br />208 <br />1 <br />X <br />C-23,25 , C-27,29 <br />Amana <br />HDC-18 <br />D30 <br />1 <br />Packing Station wl Cup Disp.& Dipper Well <br />6.0 <br />1.24 <br />208 <br />1 <br />X <br />C-19,21 <br />Kitchen Equip. Supplier <br />CUSTOM <br />D70 <br />2 <br />Dispenser, Hot Water, 5 gal. Wall Mounted <br />19.2 <br />4.03 <br />208 <br />1 <br />X <br />C-20,22 , C-24,26 <br />Bunn-O-Matic <br />H5X40-208 <br />D81 <br />1 <br />Chubb Warmer, Elec Rethermalizer. <br />47.6 <br />9.5 <br />1 <br />208 <br />1 <br />X <br />D-4,6 <br />Ultrafryer Systems <br />REO-1620 <br />D90 <br />1 <br />Holding Cabinet, Reach -In <br />17.6 <br />2.11 <br />120 <br />1 <br />X <br />C-28 <br />Winston <br />HA4522POP <br />D92 <br />2 <br />Side Items Holding Unit, Pass-Thru <br />13.87 <br />3.33 <br />208 <br />1 <br />X <br />C-1,3 , C-5,7 <br />Prince Castle <br />DHB-P1A <br />D93 <br />1 <br />Chicken Holding Cabinet <br />25.7 <br />6.16 <br />208 <br />1 <br />X <br />C-13,15 <br />Prince Castle <br />DHB2PT-44E <br />D94 <br />1 <br />Dedicated Holding Unit, 12 Pans 4 x 3H <br />23.7 <br />5.7 <br />208 <br />1 <br />X <br />C-9,11 <br />Prince Castle <br />DHB3PT-41 <br />F15 <br />1 <br />Exhaust Hood, Back Shelf, 6-20" Fryers <br />115 <br />1 <br />X <br />D-19 <br />Action Air <br />GL-L <br />F15.1 <br />1 <br />Heated Holding Unit, Wall Mount <br />18.8 <br />13.9 <br />1208 <br />1 <br />X <br />H-3,5 <br />Kitchen Equip. Supplier <br />CUSTOM PC-HPL52-26 <br />H10.4PD <br />1 <br />Production Counter Dual Line 52 1/4" x 134" Prince Castle <br />14.0 <br />3.5 <br />120/208 <br />1 <br />X <br />C-2,4 , C-6,8 , C-10,12 <br />Kitchen Equip. Supplier <br />CUSTOM <br />J40 <br />1 <br />Refrigerator, Undercounter <br />4.9 <br />1/6 <br />120 <br />1 <br />X <br />C-17 <br />Silver Kin <br />SK-SR <br />K10 <br />1 <br />Ice Cuber w/ Remote Condenser <br />11.9 <br />6.7 <br />1 1/2 <br />208-230 <br />1 <br />X <br />C-30,32 <br />Manitowoc <br />SY 0894N/JC-0895SA <br />K31 <br />1 <br />Soda Dispenser, 8 Head, Drop -In, Fast Flow Valves <br />1.5 <br />115 <br />1 <br />X <br />A-13 <br />Comelius <br />CB 2323-AK8 <br />K32 <br />1 <br />Soda Dispenser, 8 Head, Counter w/ Ice Bin Adapter Plate <br />4.0 <br />115 <br />1 <br />X <br />A-5 <br />Comelius <br />Duraflex 250-02803 <br />K42 <br />1 <br />Ba -N-Box Rack w/ 2 Carbonators on Shelves <br />7.2 <br />1/3 <br />115 <br />1 <br />X <br />A4 <br />Bib Flex Rack <br />K71 <br />1 <br />Brewer, Tea & Coffee <br />14.0 <br />1.7 <br />120 <br />1 <br />X <br />A-23 <br />Bunn-O-Matic <br />ICTB <br />M10 <br />1 <br />Office Wall Cabinet <br />120 <br />1 <br />X <br />A-6, A-8, A-10, A-12 <br />General Contractor <br />Custom <br />M30 <br />1 <br />Safe <br />5.0 <br />0.6 <br />115 <br />1 <br />X <br />A-11 <br />NKL Industries <br />BSM292020A BAX <br />P20 <br />4 <br />Cash Register <br />115 <br />1 <br />X <br />A-7, A-9 <br />POS System <br />P30 <br />3 <br />Printer <br />115 <br />1 <br />X <br />A-7, A-9 <br />POS System <br />Q10 <br />1 <br />Menu board, 7 Panels <br />115 <br />1 <br />X <br />B-15 <br />LSI <br />Custom <br />Q20 <br />2 <br />Menuboard, Drive-Thru <br />115 <br />1 <br />X <br />B-1 <br />LSI <br />Custom <br />Q21 <br />1 <br />Remote Sneaker Tower, Drive-Thru <br />115 <br />1 <br />X <br />A-16 <br />ILSI <br />Custom <br />CABLES <br />,CONDUIT BUSHING WITH TERMINATION <br />AT 6" ABOVE FINISHED CEILING. <br />DATA f DATA CEILING GRID <br />1" CONDUIT WITH <br />TEL PULL STRING AS NOTED. <br />TELEPHONE <br />DUAUDOUBLE RECESSED SINGLE GANG <br />LCELECTRICAL BOX. <br />TEL 1/1 <br />LL <br />4 aZ <br />v0/I o <br />SINGLE vo/I <br />FINISHED FLOOR <br />TYPICAL GOB'" STUB UP DETAIL <br />SCALE: N.T.S. <br />REFR TO SITE <br />PLAN FOR <br />EXACT LOCATION <br />-EXTERIOR MENUBOARD <br />SEE SITE PLAN FOR <br />ORIENTATION <br />BOX <br />NOTE: REFER TO MFR. LITERATURE <br />LITERATURE FOR SPECIFIC INSTALLATION <br />INSTRUCTIONS FOR PREFAB LOOP <br />KEYED NOTES <br />DRAWING NOTES O <br />1. EXISTING ELECTRICAL SERVICE TO REMAIN. <br />2. SEE DRIVE THRU DETAIL THIS SHEET FOR DEVICES IN THIS AREA <br />3. VERIFY EXACT LOCATION OF MENUBOARD AND SPEAKERBOX <br />WITH SITE PLAN. <br />4. PRODUCTION COUNTER ELECTRICAL POWER CIRCUITS REFER TO <br />PANEL SCHEDULE "C" FOR CIRCUIT NO'$. REFER TO EQUIPMENT <br />SUPPLIER SHOP DRAWINGS FOR EXACT LOCATIONS AND TYPE <br />OF CONNECTIONS FOR EQUIPMENT AND HEAT LIGHTS IN/OR ON <br />PRODUCTION COUNTER <br />5. ROUTE ALL CONDUIT ROOF PENETRATIONS THRU (WITH -IN) ROOF <br />CURBS FOR THE EQUIPMENT. REFR TO MECH. PLANS FOR CURB <br />DETAILS. (TYPICAL) <br />6. EXISTING PANEL H CONTACTOR - CONTRACTOR SHALL EXTEND <br />CONTROL WIRING TO HOOD FIRE SUPPRESSION SYSTEM CONTACTS <br />FOR SHUTDOWN OF UNDER HOOD EQUIPMENT. <br />1. EXISTING DRIVE THRU EQUIPMENT RACEWAYS MAY BE REUSED IF <br />THEY MEET CURRENT SPECIFICATIONS AND ARE IN GOOD <br />CONDITION. OTHERWISE PROVIDE NEW AS SHOWN. <br />6. E.C. SHALL INSTALL AND WIRE RELAY CONTROL PANEL <br />PACKAGE FOR HOOD FANS EF-I AND SF-1. PROVIDE POWER AND <br />INTERLOCK CONTROL WIRING FOR HPI-F CONTROL PANEL AND <br />HOOD FIRE SUPPRESSION SYSTEM. MOUNT STARTERS AND <br />CONTROLS ON WALL. <br />( <br />'1 ON/OFF SELECTOR SWITCH AND PILOT LIGHT IN NEMA 4X <br />STAINLESS STEEL ENCLOSURE MOUNTED ON THE FACE OF THE <br />HOOD. PROVIDED BY HOOD MFR. <br />10. PROVIDE 2P30A NEMA 3R FUSED DISC SWITCH 4 L.T. <br />FLEX CONNECTION TO ROOF MTD ICE MAKER COND UNIT, <br />FUSE SIZE PER MFG'S NAMEPLATE DATA. <br />11. PROVIDE 3/4" x 24" H x 24" W PLYWOOD TELEPHONE BOARD <br />PAINTED WITH 2 COATS OF "LISTED" FIRE RETARDANT LIGHT <br />GRAY COLOR PAINT. AT 96" AFF. PROVIDE QUAD RECEPTACLE <br />ADJACENT TO BOARD. PROVIDE " 6 CU, GROUND TO SERVICE <br />ENTRANCE GROUND, SEE ARCHITECTURAL PLANS. <br />CONTRACTOR SHALL EXTEND TELEPHONE AND OR INTERNET <br />UTILITY WIRING TO THIS LOCATION. <br />12. PROVIDE CEILING OUTLET W/ISOLATED GROUND RECEPTACLES <br />SUPPORTED FROM BLDG. STRUCTURE FOR VIDEO <br />MONITOR/PRINTER 4 OR HEADSET. VERIFY EXACT <br />REQUIREMENTS 4 LOCATION. <br />13. OUTLET AND CONNECTION FOR SECURITY CAMERA. VERIFY EXACT <br />LOCATIONS AND TYPE CONNECTIONS FOR INDOOR AND OUTDOOR <br />CAMERAS WITH OWNER AND POPEYE'S CONSTRUCTION MANAGER <br />14. EXISTING DUCT MOUNTED SMOKE DETECTORS, REMOTE <br />TEST/INDICATORS, AND ROOFTOP RECEPTACLES TO REMAIN AS IS. <br />CONTRACTOR 5HAL VERIFY PROPER FUNCTION AND REPLACE OR <br />REPAIR AS NECESSARY. SEE MECHANICAL PANELS FOR EXACT <br />LOCATIONS OF DUCT DETECTORS, REMOTE INDICATORS 4 TEST SW'S. <br />15, EXISTING RTU DISCONNECT, CONDUIT, AND CONDUCTORS TO <br />REMAIN AS -IS. CONTRACTOR SHALL INSPECT ELECTRICAL <br />EQUIPMENT AND CIRCUITRY ASSOCIATED WITH THIS UNIT AND <br />REPAIR OR REPLACE AS NECESSARY. <br />16. FURNISH AND INSTALL NEW COMMUNICATION OUTLET BOX. STUB 1,011 <br />CONDUIT UP INTO CEILING SPACE AND TERMINATE WITH AN END <br />BUSHING. INSTALL CAT 6 WIRING FROM DATA PORT TO NEW <br />TELEPHONE TERMINAL BOARD IN OFFICE AND TERMINATE ON <br />PATCH PANEL. PROVIDE CAT 6 TERMINATED RJ-45 DATA JACKS <br />AND TRIM PLATES AT DROP LOCATIONS. INSTALL CAT 6 WIRING <br />FROM TELEPHONE PORT TO NEW TELEPHONE TERMINAL BOARD IN <br />OFFICE AND TERMINATE ON 66 BLOCK PROVIDE RJ-45 <br />TELEPHONE JACKS AND TRIM PLATES AT DROP LOCATIONS. THE <br />NUMBER OF DATA AND TELEPHONE PORTS 15 INDICATED NEXT TO <br />THE DATA DROP SYMBOL. ALL DATA/TELEPHONE WIRING SHALL BE <br />TERMINATED, TESTED, AND LABELED At BOTH ENDS. <br />POS SYSTEM NOTES <br />I. ALL P.O.S. (POINT OF SALE) CIRCUITS SHALL HAVE AN <br />ISOLATED GROUND WIRE BACK TO THE PANEL. ALL P.O.S. <br />EQUIP. SHALL BE WIRED INDEPENDENTLY OF ANY NON-P.O.S. <br />EQUIPMENT. <br />2. ALL RECEPTACLES FOR P.O.S. EQUIPMENT SHALL BE ISOLATED <br />GROUND WITH SURGE SUPPRESSOR TYPE. ALL RECEPTACLES <br />FOR P.O.S. EQUIPMENT SHALL BE SINGLE UNIT, UNLESS A <br />DUPLEX RECEPTACLE CAN BE USED t0 SUPPLY TWO P.O.S. <br />UNITS. DUPLEX RECEPTACLES MAY BE USED IN THE <br />MANAGER'S OFFICE FOR NON-P.O.S. EQUIPMENT (COMPUTER, <br />MUSIC, FIRE ALARM, SECURITY, ETC.) <br />3. ALL CIRCUITS FOR P.O.S. EQUIPMENT SHALL BE CONNECTED TO <br />THE SAME PHASE OF POWER IN THE PANEL. ALL BRANCH <br />CIRCUIT BREAKERS SUPPLYING PDA EQUIPMENT SHALL HAVE <br />LOCKING HANDLES DEVICES. <br />4. EACH RECEPTACLE TYPE (LOCKING OR STRAIGHT BLADE) <br />SHALL MATCH THAT OF THE EQUIPMENT FURNISHED. WHERE <br />P.O.S. EQUIPMENT IS FURNISHED WITHOUT A PLUG THE <br />RECEPTACLE SHALL BE LOCKING TYPE. COORDINATE <br />RECEPTACLE TYPES WITH THE P.OS. EQUIPMENT SUPPLIER <br />C FiNERAL NOTES <br />I. <br />VERIFY MOUNTING HEIGHTS OF ALL RECEPTACLES WITH <br />EQUIPMENT SUPPLIED PRIOR TO INSTALLATION. <br />2. <br />ALL EQUIPMENT ELECTRICAL OUTLETS ARE DIMENSIONED TO <br />CENTERLINE OF BOX FROM ABOVE FINISHED FLOOR <br />3. <br />ELECTRICAL CONTRACTOR TO PROVIDE CORD 4 PLUG <br />-LOOP/AUDIO <br />PRE-FAB DETECTOR LOOP <br />SUPPLIED & INSTALLED BY G.C. <br />CONNECTIONS FOR EQUIPMENT AS REQUIRED. <br />TO BLDG <br />FOR AUDIO <br />4. <br />REFER TO HVAC DRAWINGS FOR EXACT LOCATIONS FOR <br />OMIT WIRE REINFORCING MESH <br />CURB IN CONIC. DRIVE WITHIN 24" <br />MECHANICAL HVAC EQUIPMENT. <br />OF PREFAB LOOP <br />5. <br />ALL UNSHADED DEVICES SHALL BE MOUNTED 24" AFF UNLESS <br />OTHERWISE NOTED. SHADED DEVICES SHALL BE MOUNTED AT <br />48" UNLESS OTHERWISE NOTES. SEE SYMBOL LIST SHEET El. <br />D DRIVE THFU LOOP DETECTOR <br />SCALE: N.T.S. <br />REVISIONS <br />BY <br />00 <br />400 <br />y R <br />�w <br />¢�00. <br />yzti �' <br />E X U <br />O • U <br />O LO co <br />U • N t_ <br />ti > <br />Q E <br />Q w 3 <br />3 <br />4-z3N <br />o ti <br />� a c <br />r` o <br />00. <br />N <br />m <br />1 <br />U' <br />�f <br />,�111111111/��� <br />.. <br />v: <br />0.0 <br />�algIIIft <br />i <br />O <br />� Z <br />c W <br />Y v <br />o U -v <br />O � O <br />= <br />m <br />m V <br />N <br />02 <br />W <br />a <br />W <br />A� <br />w 1 <br />0 N <br />O <br />•0 <br />>` CL <br />m <br />Date: 03. 28. 13 <br />Scale: AS NOTED <br />Project Mgr: EJW <br />Drawn: CAD <br />Job: 13-03 <br />Sheet <br />E3 <br />