MATERIAL LEGEND <br />CONSTRUCTION NOTES <br />GENERAL NOTES <br />WILDING CODE IWORMATION <br />INDEX OF DRAWINGS <br />EARTH/ FILL <br />I. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILING SHALL <br />I. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITION OF <br />APPL ICA6LE GORES AND STANDARDS <br />TI TITLE SHEET <br />`.. <br />BRICK <br />BE IN ACCORDANCE WITH ASTM E84. ALL FINISH MATERIALS SHALL <br />MEET A CLA55 "B" INTERIOR FINISH RATING IN EXIT AND EXIT <br />ACCESS AREA. CLASS "C" ELSEWHERE. <br />THE NATIONAL FIRE CODE "FLORIDA BUILDING CODE," "FLORIDA <br />PLUMBING CODE," "FLORIDA MECHANICAL CODE," "NATIONAL <br />ELECTRICAL CODE," AND ALL OTHER APPLICABLE LOCAL, STATE, <br />THE FLORIDA BUILDING CODE, 2010 EDITION <br />• BUILDING <br />TZ A HUREVIATION SHEET <br />T3 RESPONSIBILITIES SCHEDULE <br />AND FEDERAL CODES AND ORDINANCES, AND ALL AUTHORITIES <br />• PLUMBING <br />a �: • <br />G CONCRETE <br />STUCCO, CEMENT PLASTER, LIGHTWEIGHT CONCRETE <br />2. ALL EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE <br />WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT, <br />MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS SHALL NOT <br />BE USED. <br />HAVING LOCAL JURISDICTION. <br />2. THE GENERAL CONTRACTOR SHALL PERFORM ALL WORK IN <br />ACCORDANCE WITH THE CURRENT EDITION OF THE "GENERAL <br />CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" AIA DOCUMENT <br />• MEG-IANICAL <br />• FUEL GAS <br />• ELECTRICAL <br />• EXISTING BUILDING <br />Di EXISTING / DEMOLITION ARCHITECTURAL SITE <br />MAN <br />DZ EXISTING /DEMOLITION FLOOR PLAN <br />03 EXISTING / DEMOLITION ELEVATIONS <br />2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION <br />CMU- LARGE SCALE <br />CMU- SMALL SCALE <br />3. ALL GLAZING WITHIN A 24 INCH ARC OF DOORS WHOSE BOTTOM EDGE <br />IS LESS THAN 60 INCHES ABOVE THE FLOOR AND GLASS BELOW 18" <br />A.F.F. AND ALL GLAZING IN DOORS SHALL BE SAFETY GLASS, <br />TEMPERED GLA55 OR ACRYLIC PLASTIC SHEET. PER FBC-2406.1 <br />4. OBJECTS PROTRUDING FROM WALLS WITH THEIR LEADING EDGES <br />A201• <br />3. THE CONTRACTOR SHALL, UPON DISCOVERY, GIVE WRITTEN NOTICE <br />TO THE ARCHITECT OF ANY MATERIALS, EQUIPMENT, OR DESIGN <br />FEATURES WHICH HE BELIEVES TO BE INADEQUATE OR UNSUITABLE, IN <br />VIOLATION OF LAWS, ORDINANCES, OR RULES AND REGULATIONS OF <br />ASI ARCHITECTURAL SITE FLAN AND DETAILS <br />Ala EQUIPMENT FLOOR PLAN <br />Alb EQUIPMENT FLOOR PLAN AND SCHEDULE <br />FLORIDA FIRE PREVENTION CODE FIFTH EDITION <br />NFPA 101 LIFE SAFETY CODE FLORIDA EDITION <br />NATIONAL ELECTRICAL CODE 2010 EDITION <br />METAL -LARGE SCALE <br />BETWEEN 21" AND 80" ABOVE THE FINISHED FLOOR SHALL <br />PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, <br />PASSAGEWAYS, OR AISLES. OBJECTS MOUNTED AT OR BELOW 21" <br />ABOVE FINISHED FLOOR MAY NOT PROTRUDE ANY AMOUNT. FREE <br />THE AUTHORITIES HAYING JURISDICTION OVER THE WORK, AND OF <br />ANY NECESSARY ITEMS OR WORK OMITTED FROM THE DRAWINGS. <br />4. ALL SUBCONTRACTORS SHALL USE ONLY SKILLED CRAFTSMEN, <br />Alc ENLARGED TOILET PLAN AND TOILET <br />ELEVATIONS <br />A2 REFLECTED CEILING PLAN AND DETAILS <br />2010 ADA STANDARDS FOR ACCESSIBLE DESIGN <br />USE AND OCCUPANCY CLASSIFICATION <br />METAL OR SHEET METAL -SMALL SCALE <br />l,! / <br />% WOOD FINISH <br />STANDING OBJECTS MOUNTED ON POST OR PYLONS MAY OVERHANG <br />12". PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF <br />AN ACCE5515LE ROUTE OR MANEUVERING SPACE. <br />5. PROVIDE DEADWOOD BLOCKING WITHIN WALL CAVITIES AT <br />EXPERIENCED IN THE WORK OF THEIR TRADE, TO ENSURE FIRST <br />CLASS WORKMANSHIP. ANY WORK NOT EQUAL TO BEST TRADE <br />STANDARDS SHALL BE REMOVED AND REPLACED AT NO <br />ADDITIONAL COST. SHOULD ANY SUBCONTRACTOR REFUSE TO <br />REMOVE AND REPLACE UNSATISFACTORY WORK, THE CONTRACTOR <br />A3 ROOF PLAN AND DETAILS <br />Aq, EXTERIOR ELEVATIONS <br />Asa WALL SECTIONS <br />A5b WALL SECTIONS <br />ASSEMBLY -GROUP A3 <br />WOOD BLOCKING CONTINUOUS <br />LOCATIONS INCLUDING, BUT NOT LIMITED TO, WALL MOUNTED <br />CABINETRY, FIRE EXTINGUISHER CABINETS, TOILET ACCE55ORIES, <br />GRAB BARS, WALL STOPS, ETC- ISGA. GALV. FLAT METAL MAY BE <br />USED IN LOCATIONS APPROVED BY ARCHITECT. <br />MAY REMOVE AND REPLACE IT, AND CHARGE THE COST TO THE <br />SUBCONTRACTOR <br />5. IT 15 THE GENERAL CONTRACTOR'S SOLE RESPONSIBILITY TO <br />A6d INTERIOR ELEVATIONS <br />Abb INTERIOR ELEVATIONS <br />Al DOOR SCHEDULE / DETAILS <br />CLASSIFICATION OF WORK <br />DETERMINE ERECTION PROCEDURE AND SEQUENCE TO ENSURE THE <br />I01e FINISH FLOOR <br />WOOD BLOCKING INTERMITTENT <br />rc. PROVIDE AND INSTALL PORTABLE FIRE EXTINGUISHERS AS SHOWN IN <br />SAFETY OF PEOPLE AND OF THE BUILDING AND ITS COMPONENT <br />PARTS DURING CONSTRUCTION. THI5 INCLUDES, BUT 15 NOT LIMITED <br />PER FEBC EXISTING BUILDING SECTION 405 -ALTERATION LEVEL-3 <br />IDIb FINISHES SCHEDULES <br />!171 PLYWOOD <br />THESE DOCUMENTS OR AS OTHERWISE DIRECTED BY THE LOCAL <br />FIRE MARSHAL. <br />TO, THE ADDITION OF WHATEVER TEMPORARY BRACING OR TIE <br />DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE <br />REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR <br />N1 ARG41TECTURAL SPECIFICATIONS <br />N2 ARCHITECTURAL SPECIFICATIONS <br />GENERAL BUILDING HEIGHTS AND AREAS <br />1. SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN <br />AFTER COMPLETION OF THE PROJECT. <br />TABLE 503 <br />MAX. ALLOWED <br />PROVIDED <br />GYPSUM WALLBOARD <br />ACCORDANCE WITH THE PROVISIONS OF ASTM C 635 AND ASTM C <br />(036. <br />(c. ALL PRODUCTS AND PARTS SHALL FIT TOGETHER NEATLY, WITHOUT <br />PI PLUMBING SANITARY PLAN, SCHEDULE / RISE <br />TOTAL BUILDING AREA <br />60M <br />2,411 <br />11 111 11 1 litDAMAGE <br />OR DISFIGUREMENT. EXCEPT FOR SPECIFIED CURVED <br />RIGID INSULATION <br />8. MATERIAL, OTHER THAN FOAM PLASTIC USED AS INTERIOR TRIM <br />SURFACES, ALL PRODUCTS AND PARTS SHALL BE CONSTRUCTED/ <br />MI MECHANICAL PLAN/DETAIL t LEGEND <br />BUILDING HEIGHT <br />40' <br />19'-0" <br />�vr -;v' C"C' � <br />BATT INSULATION <br />SHALL HAVE A MINIMUM CLASS C FLAME SPREAD AND <br />SMOKE -DEVELOPED INDEX WHEN TESTED IN ACCORDANCE WITH <br />ASTM E 84. <br />FABRICATED AND INSTALLED TRUE, IN LINE, AND PLUMB. ALL NON <br />CONFORMING WORK SHALL BE REJECTED AND RE -ACCOMPLISHED <br />BY THE <br />E, GENERAL CONTRACTOR AT NO ADDITIONAL COSTS TO THE <br />E) ELECTRICAL LIC'�iTINi3 PLAN <br />E2 ELECTRICAL POWER MAN <br />PLAN <br />NUMBER OF STORIES <br />I <br />I <br />- TOTALS REFLECT AREA MODIFICATION AS FOLLOWS: <br />9. INTERIOR WALL SURFACES WITHIN (2) TWO FEET OF URINALS AND <br />RISER <br />RI <br />EE3 ELECTRICAL RISCHEDULES <br />WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONA55OR5ENT <br />SURFACE TO A HEIGHT OF (4) FOUR FEET ABOVE THE FINISHED <br />1. ALL WORK SHOWN ON THE DRAWINGS SHALL BE CONSTRUCTED OF <br />NEW COMPONENTS. <br />FRONTAGE INCREASE PER FB06 C 52 = 9ld0go <br />AUTOMATIC SPRINKLER SYSTEM PER FBC 5062 = 0.0mo <br />ELECTRICAL SPECIFICATIONS AND LEGEND <br />FLOOR MINIMUM. THE MATERIALS USED IN SUCH WALLS SHALL BE OF <br />A TYPE THAT 15 NOT ADVERSELY AFFECTED BY MOISTURE. <br />8. ALL BIDS SHALL BE PREPARED FROM A COMPLETE SET OF <br />EXISTING GROSS BUILDING AREA 2331 SQF <br />CONSTRUCTION DOCUMENTS. COMPLETE SETS OF DOCUMENTS SHALL <br />ADDITION GROSS BUILDING AREA 140 SQF <br />10. 51GNAGE SHALL BE PROVIDED AS REQUIRED AND AS STATED IN THE <br />NOT BE BROKEN UP FOR BID PURPOSES. SUCH ACTION MAY RESULT <br />2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION <br />IN A LACK OF INFORMATION IN REFERENCE TO THE SCOPE OF WORK <br />TOTAL GROSS BUILDING AREA 2,411 SQF <br />AND SHALL COMPLY WITH CHAPTER 1 SECTION 103 SIGNS. <br />TO BE PERFORMED. <br />' <br />TYPES OF CONSTRUCTION <br />11. GENERAL CONTRACTOR TO PROVIDE A FINAL CONCLUSION REPORT <br />STATING COMPLIANCE WITH "NFPA -101: <br />STANDARD METHODS OF FIRE TESTS FOR FLAME PROPAGATION OF <br />9. It SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO <br />PERSONALLY FIELD INSPECT THE PROJECT SITE PRIOR TO THE <br />PREPARATION AND SUBMITTAL OF HIS BID. THIS INSPECTION 15 <br />Q��/}� <br />�/ ' ' I�L LEGEND <br />TEXTILES AND FILMS." <br />REQUIRED SO THAT THE CONTRACTOR SHALL BE TOTALLY FAMILIAR <br />TYPE OF CONSTRUCTION - VB UNSPRINKLERED <br />CALIFORNIA FIRE MARSHAL REPORT IS ACCEPTABLE. <br />WITH THE EXISTING CONDITIONS AND THEIR INTERFACE WITH THE NEW <br />CONSTRUCTION AS DEFINED IN THESE CONSTRUCTION DOCUMENTS. <br />TABLE 601 - FIRE RESISTANCE RATING FOR BUILDING ELEMENTS <br />_ <br />10. UNLESS OTHERWISE SPECIFIED, THE G.G. SHALL FURNISH A WRITTEN <br />BUILDING ELEMENT <br />REQUIRED <br />PROVIDED <br />BUILDING SECTION SYMBOL <br />GUARANTEE FOR ALL WORK (EQUIPMENT, MATERIALS, AND LABOR), <br />AGAINST ANY DEFECTS IN SAID WORK FOR A PERIOD OF ONE (1) <br />PRIMARY STRUCTURAL FRAME <br />0 HR <br />0 HR <br />YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION, WITH ALL <br />APPROPRIATE REPAIRS OR REPLACEMENTS AT NO ADDITIONAL <br />BEARING WALLS -EXTERIOR <br />0 HR <br />0 HR <br />COST TO THE OWNER <br />BEARING WALLS - INTERIOR <br />0 HR <br />0 HR <br />_ <br />11. It SHALL BE THE RESPONSIBILITY OF THE G.G. AND/OR <br />CONTRACTORS TO COMPLY WITH ALL THE REQUIREMENTS OF THE <br />OCCUPATIONAL SAFETY AND HEALTH ACT OF 1910 BY THE U.S. <br />NONBEARING WALLS AND PARTITIONS - <br />EXTERIOR <br />0 HR <br />0 HR <br />NONBEARING WALLS AND PARTITIONS - <br />INTERIOR <br />0 HR <br />0 HR <br />WALL SECTION SYMBOL <br />DEPARTMENT OF LABOR, AND REQUIRE ALL ITS SUBCONTRACTORS <br />AND EMPLOYEES t0 COMPLY WITH THIS LAW, AND ANY RELATED <br />_ <br />STATE OR LOCAL LAWS. <br />12, THE DATA GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS <br />COULD BE SECURED. THEIR A55OLUTE ACCURACY 15 NOT <br />GUARANTEED, AND THE G.G. SHALL OBTAIN EXACT LOCATIONS, <br />FLOOR CONSTRUCTION AND SECONDARY <br />MEMBERS <br />HR <br />0 HR <br />ROOF CONSTRUCTION AND SECONDARY <br />MEMBERS <br />0 HR <br />0 HR <br />DETAIL SYMBOL <br />MEASUREMENTS, LEVELS, ETC. AT THE SITE AND SHALL <br />SATISFACTORILY ADAPT HIS WORK TO THE ACTUAL CONDITIONS OF <br />TABLE 602 - FIRE RESISTANCE RATII G FOR EXTERIOR WALLS BEARING AND NON BEARING <br />THE BUILDING. DO NOT SCALE PRINTS. VERIFY ALL DIMENSIONS <br />BASED ON FIRE SEPARATION DISTANCE <br />WITH THE ARCHITECT PRIOR TO COMMENCING WORK. <br />FIRE SEPARATION DISTANCES <br />REQUIRED <br />PROVIDED <br />_ <br />13. THESE DOCUMENTS AND THE INFORMATION CONTAINED HEREIN SHALL <br />NOT BE ALTERED IN ANYWAY BY THE CONTRACTOR OR THE OWNER <br />LESS THAN 5'-0" <br />I HR <br />WA <br />'� -- DETAIL SYMBOL <br />ALTERATIONS SHALL BE MADE ONLY BY THE ARCHITECT OF <br />RECORD. <br />FROM 5'-0" 70 10'-0" <br />I HR <br />N/A <br />FROM 10-0" TO 20'-0" <br />0 HR <br />N/A <br />` <br />FROM 20-0" 70 30'-0" <br />0 HR <br />N/A <br />F.F.E. ELEVATION MARK <br />GREATER THAN 30-0" <br />0 HR <br />N/A <br />' <br />FIRE AND SMOKE PROTECTION FEATURES <br />TOP OF SLAB <br />�\ INTERIOR ELEVATION MARK <br />-/-- <br />ASSEMBLY FIRE RATINGS <br />REQUIRED <br />PROVIDED <br />FIRE WALL - 106.1 AND TABLE 106.4 <br />N/A <br />KEYED DRAWING NOTES <br />SHAFT AND EXIT ENCLOSURES - 106.4 / 1018.1 <br />LESS THAN 4 STORIES <br />N/A <br />OCCUPANCY SEPARATION - 10138 / 508 <br />N/A <br />O DOOR NUMBER SYMBOL <br />TENANT SEPARATION - 10al <br />N/A <br />`' /� <br />LORIDA •• ODUCT APPROVAL <br />EXIT PASSAGEWAY -TOTES / 1022.1 <br />WA <br />090 ROOM NUMBER SYMBOL <br />tip <br />HORIZONTAL EXIT - 1013.4 / 1023.1 <br />N/A <br />SYSTEM <br />MANUFACTURER <br />PRODUCT <br />APPROVAL NUMBER <br />SINGLE OCCUPANCY FIRE AREA - 1013.9 <br />N/A <br />OWINDOW SYMBOL <br />ENTRANCES <br />35W <br />STOREFRONT DOORS <br />FL 16554.1 <br />CORRIDORS (OCCUPANT LOAD LESS THAN <br />30) - 1018.1 (UNSPRIWLERED) <br />N/A <br />WINDOWS <br />YKK YHS 50FI <br />STOREFRONT <br />FL 142182 <br />1 <br />ROOFING <br />DURo-LAST <br />SINGLE -PLY <br />FL 1559.R8 <br />INTERIOR FINISHES <br />WINDOWS <br />QUIKSERV <br />DRIVE-THRU. <br />FL 12643,I.R2 <br />REVISION <br />PROJECT SCOPE <br />DOORS <br />PRODUCTS.9 <br />HOLLOW METAL DOORS <br />FL 14231-R1 <br />INTERIOR WALL AID CEILING FINISH REQUIREMENTS BY OCCUPANCY - TABLE 803DOOR <br />STRUCTURAL COMPONENT <br />SIMPSON STRONG TIE <br />SPI <br />FL 10456.41-RI <br />GROUP: ASSEMBLY GROUP A-2 UNSPRINKLERED <br />1. RENOVATIONS TO A FREE STANDING SINGLE STORY ARBY'S <br />STRUCTURAL COMPONENT <br />SIMPSON STRONG TIE <br />A34 <br />FL 104463 <br />EXIT ENCLOSURES AND EXIT PASSAGEWAYS <br />CLASS A <br />STRUCTURAL COMPONENT <br />SIMPSON STRONG TIE <br />A35 <br />FL 11418.1 <br />CORRIDORS <br />CLASS A <br />RESTAURANT BUILDING INCLUDING EXTERIOR AND INTERIOR <br />RENOVATIONS. ADD STORAGE ROOM (140 SQR) <br />2. ALL EXTERIOR SIGNAGE, TO BE SUBMITTED UNDER SEPARATE <br />STRUCTURAL COMPONENT <br />SIMPSON STRONG TIE <br />H3 <br />FL 10456.1E <br />ROOMS AND ENCLOSED SPACES <br />CLASS B <br />MEANS OF EGRESS <br />WALL TYPES <br />PERMIT BY THE SIGNAGE CONTRACTOR <br />3. COMMERCIAL KITCHEN HOOD AND SUPPRESSION SYSTEM IS <br />TABLE IM411 - MAXIMIl1M FLOOR AREA ALLOW,4NCE PER OCCUPANT <br />EXISTING TO REMAIN. (NO RENOVATION). <br />4. GENERAL CONTRACTOR TO SUBMIT PERMIT APPLICATION FOR THE <br />KEY PLAN SECTION SYMBOL <br />FUNCTION OF SPACE <br />OCCUPANTS <br />ROOFING PERMIT. <br />5. EXTERIOR METAL CANOPIES AND BAND TO BE SUBMITTED UNDER <br />SEPARATE PERMIT BY ARBY'S VENDOR <br />GROUP ASSEMBLY A3 <br />DINING UNCONCENTRATED SEATS <br />31 PERSONS <br />DINING -FIXED SEATS <br />21 PERSONS <br />STANDING SPACE <br />25 PERSONS <br />/y <br />LOCATION MAP <br />l I <br />TEAM <br />PROJECT TE A <br />KITCHEN <br />5 PERSONS <br />TOTALS <br />94 PERSONS <br />- - <br />aj <br />�- <br />ARCHITECT <br />OLIVERI ARCHITECTS <br />32101 U.S. HWY.19 <br />PALM HARBOR, FLORIDA 34684 <br />121-181-1525 <br />'r <br />PROJECT <br />LOCATION <br />F:,x a <br />MEANS OF EGRESS <br />REQUIRED <br />PROVIDED <br />EGRESS WIDTH PER PERSON (LEVEL) - 1005.1 <br />02" x OC = TOTAL <br />02"X 122=24,4" <br />MINIMUM CLEAR EXIT DOOR OPENING - 1008.1.1 <br />32" <br />>32" <br />rLIIN� MECHANICAL <br />MDCI FLORIDA INC. <br />405, 2ND STREET SOUTH, SUITE B <br />SAFETY HARBOR, FLORIDA 34695 <br />121E698-0398 <br />,u R,anGr <br />r„ x <br />- <br />MINIMUM CLEAR STAIR WIDTH - 1009.1 <br />44" <br />MAXIMUM COMMON PATH OF TRAVEL - 1014E <br />15 F7 <br /><15 Fr. <br />MAXIMUM TRAVEL DISTANCE - TABLE 1016.1 <br />200 FT <br />g00 FT, <br />MINIMUM CORRIDOR WIDTH - 10182 <br />44" <br /><44 FT. <br />ELECTRICAL <br />ELECTRICAL CONSULTING AND DESIGN, INC. <br />9225 ULMERTON ROAD - SUITE G <br />MAXIMUM DEAD END CORRIDOR LENGTH - <br />1016.4 <br />20 FT <br /><20 P• <br />LARGO, FLORIDA 33-1-11 <br />121-581-4318 <br />.< '� ul,A, `- <br />MINIMUM NUMBER OF EXITS - 1021.1 / 10212 <br />2 <br />3 <br />as awn - <br />i� <br />REVISIONS <br />BY <br />i <br />u <br />• r <br />u�� <br />- � r <br />C U <br />5 ti <br />o � <br />vi U <br />W <br />- <br />s` <br />O <br />V) <br />C <br />O <br />a <br />� <br />O <br />-L <br />O <br />N <br />CC <br />N m <br />^ <br />.0 <br />N <br />m <br />`0 <br />X <br />Q c0 L <br />>` <br />W <br />c <br />� a <br />m <br />p <br />IV <br />i <br />O <br />O <br />C <br />F <br />. 09. 15 <br />NOTED <br />Project Mgr: RNS <br />Drawn: DC <br />Job: <br />15-50 <br />Sheet <br />T2 <br />H:\Projects\Projects 2015\15050 - Arby's Gall Blvd\04-CD\01-CD.A\04-Architectural\_T2-ABBV.dwg, 6/10/2015 12:07:34 PM, dcosta, AutoCAD PDF (High Quality Print).pc3 <br />