My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7446 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7446 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:25:17 PM
Creation date
2/18/2025 3:39:51 PM
Metadata
Fields
Template:
Building Plans
Street #
7446
Location
Gall Blvd
Contractor
Southland Construction
Building Plans - Permit #
16576
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J-BG <br />FOR <br />EX SIGNAGE <br />CIRGUIT VIA LC <br />FIXTURE SCHEDULE <br />,SYM <br />MANUFACTURER <br />CATALOG NUMBER LAMPS <br />MTG. <br />DESCRIPTION <br />D <br />JUNO LIGHTING <br />CH8-2180-850C-WH <br />2- CFQ18W/ <br />RECESSED <br />RECESSED DOWNLIGHT <br />NATIONAL ACCOUNT: E.sAMJONES <br />CONTACT: KEVIN PRICE <br />G2402 <br />12.700K <br />NATIONAL ACCOUNT. E.SAM JONES <br />LIGHTING ALLOWANCE CALCULATION <br />CONTACT: KEVIN PRICE. PHONE: 1-800-624-9849 <br />2010 FBC CHAPTER 5 <br />WATTAGE TOTAL ACTUAL <br />P1 <br />KAREN CLEGG <br />42046OZ <br />1 -VINTAGE <br />PENDANT <br />PENDANT DECORATIVE LIGHT FIXTURE <br />SQUIRREL CAGE <br />FILAMENT BULB <br />NATIONAL ACCOUNT: E.SAM JONES <br />ALLOWED PER WATTAGE BALLAST BALLAST WATTAGE <br />ROOM NAME AREA SQUARE FOOT ALLOWED LAMP TYPE QUANTITY WATTAGE USED <br />P2 <br />KAREN CLEGG <br />78200 <br />1 - 100W <br />PENDANT <br />PENDANT DECORATIVE LIGHT FIXTURE <br />DINING AREA 1456 2.1 30S7.6 2-18W CFL 23 39 897! <br />1-100W 10 100 1000 <br />5-40W 4 200 800 <br />W <br />TECH LIGHTING <br />LYNN SCONCE 70OBCLYNNWZ <br />5 - 40W G9 <br />WALL <br />WALL DECORATIVE LIGHT FIXTURE <br />HALOGEN <br />FOOD PREP 875 1.2 1050 3-32W T8 15 85 1275 <br />A <br />LITHONIA LIGHTING <br />REAL6C-DI-MW-1000L-0.95SC-120- <br />14.2 LED <br />RECESSED <br />EXTERIOR RECESSED DOWNLIGH WITH WHITE <br />-6VL-PFMW-ISH <br />BY MFR <br />TRIM RING (PAINT TO MATCH DECOR) <br />OFFICE 38 1.1 41.8 3-32W T8 1 85 85 <br />NATIONAL ACCOUNT: E.SAM JONES <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />RESTROOMS 115 0.9 103.5 3-32W T8 2 85 170 <br />F1 <br />LITHONIA LIGHTING <br />2SP8-G-2-U316-Al2-MVOLT-GEB101S <br />2 - 32W T8 <br />RECESSED <br />2' X 2' FLUORESCENT TROFFER WITH STEEL <br />HOUSING AND DOOR FRAME FULLY GASKETED <br />3,000K <br />NATIONAL ACCOUNT: E.SAM JONES <br />TOTALS 2484 4252.9 4227 <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />COMF LIES BY 25.9 <br />F2 <br />LITHONIA LIGHTING <br />2SP8-G-3-32-Al2-MVOLT-GEB101S <br />3 - 32W T8 <br />RECESSED <br />2' X 4' FLUORESCENT TROFFER WITH STEEL <br />3.000K <br />HOUSING AND DOOR FRAME FULLY GASKETED <br />NATIONALACCOUNT: E.SAM JONES <br />CONTROL NOTE: <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />BUILDING IS NOT LARGER THAN 5000 SQ. FEET <br />EMI <br />NAVILITE <br />NIWH <br />2- 5AW, 6V <br />SURFACE/ <br />THETMOPLASTIC EMERGENCY LIGHTWITH <br />AUTOMATIC LIGHTING CONTROL IS NOT REQUIRED <br />BY MFR <br />CEILING <br />ADJUSTABLE HEADS AND LEAD CALCIUM BATTERY <br />NATIONAL ACCOUNT: E.SAM JONES <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />EM2 <br />TCP <br />207R4 <br />2 - 5AW, 6V <br />SURFACE <br />GREY TWO HEAD WEATHERPROFF REMOTE <br />LITHONIA LIGHTING <br />BY MFR <br />EMERGENCY EGRESS LIGHT <br />NATIONAL ACCOUNT: E.SAM JONES <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />EM3 <br />TCP <br />20784 <br />2 - 5AW, 6V & <br />SURFACE <br />THERMOPLAS11C TYPE EXIT SIGN WITH ADJUSTABLE <br />LITHONIA LIGHTING <br />T5 WEDGE <br />HEADS, RED LETTERS AND EM BATTERY BACK UP <br />BY MFR <br />NATIONAL ACCOUNT: E.SAM JONES <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />X <br />TBD <br />TBD <br />1-75W <br />RECESSED <br />EXTERIOR RECESSED LIGHT FIXTURE MOUNTED IN SLAB <br />MAX <br />IN THE SLAB <br />COORDINATE WITH NATIONAL ACOUNTAND OWNER <br />NATIONAL ACCOUNT E.SAM JONES <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />Y <br />TBD <br />TBD <br />1-75W <br />WALL <br />EXTERIOR WALL DECORATIVE LIGHT FIXTURE <br />MAX <br />COORDINATE WITH NATIONAL ACOUNTAND OWNER <br />NATIONAL ACCOUNT: E.SAM JONES <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />Z <br />TBD <br />TBD 1-75W <br />WALL <br />EXTERIOR WALL DECORATIVE LIGHT FIXTURE <br />MAX <br />COORDINATE WITH NATIONAL ACOUNTAND OWNER <br />NATIONALACCOUNT: E.SAM JONES <br />CONTACT: KEVIN PRICE, PHONE: 1-800-624-9849 <br />L Ir_:�HTING; SCHEDULE NOTES <br />1, PROVIDE ALL FIXTURES COMPLETE WITH LAMPS. REFER TO NATIONAL ACCOUNT SOURCE INFO FOR <br />LAMP SPECS. <br />2. ALL INCANDESCENT LAMPS SHALL BE RATED 130 VOLTS. <br />3 ALL BALLASTS SHALL BE HIGH POWER FACTOR FLUORESCENT BALLASTS FOR T8 LAMPS TO BE <br />ADVANCED MANUFACTURED OPTANIUM WATT MISER, EXCEPT OUTDOOR FIXTURES TO BE <br />ZERO -DEGREE MAGNETIC BALLASTS. <br />41 PROVIDE HOLD DOWN CLIPS FOR EACH CORNER OF FLUORESCENT GRID TROFFERS. <br />5. PROVIDE ALL REQUIRED MOUNTING OR HANGING HARDWARE. <br />6. COORDINATE AND VERIFY ALL FIXTURE INFORMATION, TYPES AND FINAL LOCATIONS WITH THE <br />REFLECTED CEILING PLAN. <br />�. LAMPS SHALL BE AS MANUFACTURED BY SYLvANIA, WESTINGHOUSE, GENERAL ELECTRIC, OR <br />APPROVED EQUAL. <br />OL <br />IGHTINC- FIXTURE. SCWr=0ULE <br />J(DI <br />L IGW ING ALLOWANCE <br />SCALE: NOT TO SCALE <br />SCALE: NOT TO SCALE <br />J - BOX <br />FOR SIG <br />0 ELECTRICAL LIGHTINC3 PLAN <br />SCALE: 3/16" = P-0" <br />KEYED NOTES <br />DRAWING NOTES <br />I. WALK-IN AND FREEZER LIGHTS ARE EXISTING TO <br />REMAIN, <br />2, VERIFY' THE EXACT LOCATION OF SIGNS, AND FASCIA <br />BOXES BEFORE INSTALLATION OF JUNCTION BOXES. <br />3- ELECTRICAL CONTRACTOR SHALL VERIFY EXACT <br />SIGN(S) WIRING REQUIREMENTS WITH THE SIGN <br />SUPPLIER PRIOR TO SUBMITTING A BID FOR THE <br />ELECTRICAL_ <br />4. THE EXTERIOR BUILDING SIGNAGE AND LIGHTING <br />SHALL BE ROUTED VIA LIGHTING CONTACTORS FOR <br />AUTOMATIC 4 MANUAL CONTROL_ FILED VERIFY <br />EXISTING CONTACTOR/S AND PROVIDE NEW LIGHTING <br />CONTACTOR/5 IF NEEDED, COORDINATE FINAL <br />REQUIREMENTS WITH OWNER- <br />5. PROVIDE DECORA OCCUPANCY SENSORS IN AREAS <br />SHOWN. LEVITON 00D515-ID. <br />6, ALL "EX" EMERGENCY E EXIT LIGHTING FIXTURES <br />SHALL BE CONNECTED AHEAD OF ROOM/AREA <br />SWITCHING/CONTROL PER NATIONAL ELECTRICAL <br />GODE (NEG) ARTICLE i00-12(F), <br />-1, PROVIDE FLANGE KIT FOR RECESSED 2'X4' LIGHTS IN <br />REST ROOMS- <br />0. UTILIZE EXISTING SIGNAGE BRANCH CIRCUIT FROM THE <br />DEMOLISHED SIGNAGE FOR NEW THE BUILDING <br />SIGNAGE (FIELD VERIFY EXACT GIRCUIT). EXTEND NEW <br />WIRES/CONDUITS TO NEW SIGNAGE LOCATION AS <br />NEEDED. <br />9- UTILIZE EXISTING EXTERIOR LIGHTING BRANCH <br />CIRCUIT FROM THE DEMOLISHED EXTERIOR LIGHTING <br />FOR THE NEW EXTERIOR LIGHTING (FIELD VERIFY <br />EXACT CIRCUIT). EXTEND NEW WIRES/CONDUITS TO NEW <br />LIGHTING FIXTURE LOCATIONS AS NEEDED. <br />10, THE INTERIOR LIGHTING SHALL BE ROUTED VIA <br />EXISTING LIGHTING SWITCH BANK FOR MANUAL <br />CONTROL. COORDINATE FINAL REQUIREMENTS WITH <br />OWNER_ <br />IL EXISTING LIGHT SWITCH BANK FOR INTERIOR LIGHTING <br />CONTROL. COORDINATE FINAL REQUIREMENTS WITH <br />OWNER, <br />12. EXTEND TO EXISTING LIGHTING CIRGUIT IN THIS AREA, <br />PROVIDE NEW BRANCH CIRCUIT WIRING INDICATED <br />WITH AN UNSWITGHED CONDUCTOR FOR ALL <br />EMERGENCY AND EXIT LIGHTS_ THE CONTRACTOR <br />SHALL VERIFY WITH AN AMPROBE THAT THE EXISTING <br />CIRCUIT HAS ADEQUATE CAPACITY AND NOTIFY THE <br />ARCHITECT IN THE EVENT OF ANY CONFLICT_ <br />6eNERAL NOTES <br />GENERAL NOTES - <br />I. PROVIDE ALL FLOURESCENT FIXTURES WITH BALLAST <br />DISCONNECTING MEANS PER NEC: <br />2. "NL" DESIGNATION INDICATES FIXTURE TO BE NIGHT <br />LIGHT, CIRCUITED HOT FOR CONTINUOUS OPERATION. <br />3. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL <br />THE EQUIPMENT INDICATED WITHIN THESE DRAWINGS <br />UNLESS OTHERWISE NOTED. VERIFY LOCATION AND <br />DIMENSIONS IN THE FIELD PRIOR TO FABRICATION AND <br />/ OR INSTALLATION. <br />4. THE ENTIRE INSTALLATION SHALL BE GUARANTEED <br />FREE OF DEFECTS AND CONTRACTOR SHALL REPAIR <br />AND / OR REPLACE ANY DEFECTIVE MATERIALS OR <br />EQUIPMENT AT NO COST TO THE OWNER FOR A MINIMUM <br />PERIOD OF ONE YEAR FROM THE DATE OF <br />ACCEPTANCE BY ARCHITECT OR OWNER- <br />5, ALL WORK SHALL BE SUBJECT TO THE ACCEPTANCE <br />AND APPROVAL OF THE ARCHITECT AND OWNER THE <br />ARCHITECT SHALL BE NOTIFIED OF ANY AND ALL <br />DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE <br />CONTRACT DOCUMENTS BEFORE PROCEEDING WITH <br />THAT PORTION OF THE WORK FAILURE OF PROPER <br />NOTIFICATION DOES NOT RELIEVE THE CONTRACTOR <br />THE CONTRACTOR SHALL CORRECT ANY AND ALL <br />WORK ARISING FROM SUCH FAILURE TO COORDINATE <br />DISCREPANCIES TO THE SATISFACTION OF THE <br />ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER <br />6. ALL JUNCTION BOXES SHOWN ON THIS PLAN ARE TO BE <br />INSTALLED ABOVE THE FINISHED CEILING- <br />"T, PROVIDE WOOD BLOCKING BEHIND ALL EXTERIOR <br />LIGHTING FIXTURES COORDINATE WITH GENERAL <br />CONTRACTOR <br />8. SPEAKER AND SOUND SYSTEM TO BE PROVIDED AND <br />INSTALLED BY ELECTRICAL CONTRACTOR LOCATE <br />VOLUME CONTROL IN THE OFFICE. SEE ARCHITECTURAL <br />CEILING PLAN FOR EXACT LOCATION AND CONTROL. <br />REVISIONS <br />BY <br />�i <br />7 <br />J <br />INN J .r <br />J� <br />- . <br />= cr, <br />ti <br />•--• _ 2 <br />vi <br />W <br />a <br />U <br />06-09-15 <br />STATE OF \. <br />V <br />,`:_ <br />� U <br />z z . <br />s= <br />AAk <br />F <br />uJ <br />i <br />O <br />%+- <br />W <br />C <br />0 <br />} o <br />0 <br />O �L <br />C > O <br />(1)0 m LL. <br />aC <br />L <br />o in v vi <br />N � <br />X (rD L <br />W <br />-o a <br />� <br />� O <br />V fV <br />L_ <br />0 <br />N <br />t <br />C <br />Date: 06. 09. 15 <br />Scale: AS NOTED <br />Project Mgr: RNS <br />Drawn: IT/WR <br />Job: 15-50 <br />Sheet <br />El <br />
The URL can be used to link to this page
Your browser does not support the video tag.