NOTES: Z o o a o N
<br />d M 3 M cN
<br />1. FLOOR AND GROUND SURFACES SHALL COMPLY WITH 1,2,&3/GO10. 9l0`'�� r �� o 0
<br />1.1. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE /y ly�� S`° o 0 v v '
<br />ACCESSIBLE PERMITTED. NOTES: 2. ACCESSIBLE ROUTES SHALL COMPLY WITH 9/G010. 9 `Po > �G? ��^\\ 9 0 8 V ° �
<br />PARKING 2. ACCESSIBLE ROUTES SHALL COMPLY WITH 9/GO10. 1. FLOOR AND GROUND SURFACES SHALL COMPLY WITH 3, UNLESS INDICATED OTHERWISE IN THESE DETAILS, o o �'� ,� `��� LANDING AREA � v v o;
<br />ACCESSIBLE VAN ACCESSIBLE ACCESSIBLE VAN ACCESSIBLE ACCESSIBLE SIGNAGE, 3. VERTICAL CLEARANCE: MIN. 98" (8'-2' MIN. 1,2,&3/G010. CURB RAMPS AT ACCESSIBLE ROUTES ARE REQUIRED ti� � '�S' 1:48 CROSS E �° HANDICAPPED PARKING HANDICAPPED PARKING HANDICAPPED PARKING HANDICAPPED PARKING HANDICAPPED PARKING COMPLY WITH 4. CONTINUE ACCESSIBLE ROUTES AND AISLE MARKINGS ACROSS 1.1. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 TO MEET THE REQUIREMENTS OF RAMPS ON `!' Q �� �,' �Gq,� ��� `\\ SLOPE (MAX.) v l
<br />SIGNAGE, SEE DIAGRAM SIGNAGE, SEE DIAGRAM SIGNAGE, SEE DIAGRAM SIGNAGE, SEE DIAGRAM SIGNAGE, SEE DIAGRAM SIGNAGE VEHICULAR ZONES TO PEDESTRIAN ZONES. PARKING SPACES AND SHALL BE PERMITTED. ACCESSIBLE ROUTES (2/G010.01). < �iJ, ,p,, ti > Q
<br />THIS DETAIL. THIS DETAIL. THIS DETAIL. THIS DETAIL. THIS DETAIL. REQUIREMENTS. ACCESS AISLES SHALL NOT OBSTRUCT THE REQUIRED CLEAR WIDTH OF PAVEMENT CROSSWALK GJ �J `\\ J 'io o,' ,ate.,
<br />ADJACENT ACCESSIBLE ROUTES. MARKINGS, TYP. ._
<br />S
<br />CG'f'� \ \ V 0 m "
<br />RESERVED RESERVED
<br />,o WHERE PROVIDED, CURB < Z 2 o
<br />PARKING PARKING LL
<br />z z z `£ " �� �� PARKING SPACE MINIMUM NUMBER REQUIREMENTS RAMP FLARES SHALL HAVE
<br />o W o W W£ n 63 A 1:10 SLOPE (MAX.) Q) « w
<br />� ne W k TOTAL NUMBER OF PARKING SPACES MINIMUM NUMBER OF REQUIRED • 0 `y°c «
<br />----- JQ` ° ° a ° ° PROVIDE ADA COMPLIANT > W- W r-. �' W onooa � Q
<br />s PROVIDED IN PARKING FACILITY ACCESSIBLE PARKING SPACES c, a a a a a a a
<br />c VAN G �� o o°O°0°o 0 0
<br />ACCESS AISLE TO BE DETECTABLE WARNING
<br />�� �� y 1 TO 25 1 �, aoaaaoaoaaaa
<br />_ ACCESSIBLE �a �, O4`
<br />0 0 0 0 0 0 0 0 0 0
<br />0 0 0 0 0 0 o n o o a
<br />z z ao°00000000o STRIP INSERT TO WARN
<br />�� \ 0000000aoao
<br />Q MARKED THE FULL z ¢ �� ��`' vS OF HAZARDS ON A
<br />w 41 v, Q ` o n°°°°° o ° ° ° o °a CIRCULATION PATH, SUCH U
<br />O Q O 0 0 0 0 0 0 0 0
<br />o LENGTH AND WIDTH Jo o "' 26 TO 50 2 ° W
<br />s s OF THE ACCESS s s -j \ a a a a a a N
<br />W / \n0000000° 2
<br />0° 51 TO 75 3 �� o AS CROSSING FROM A 0
<br />t '
<br />�` 0000n V
<br />Z 3 AISLE. ACCESS AISLE CN
<br />PEDESTRIAN TO VEHICULAR ``
<br />AND PARKING SPACE J F z 76 TO 100 4 �/� �> ZONE. o
<br />z DIMENSIONS SHALL z g z a m �� A� Zgb
<br />o NOT OVERLAP. TYP. o o z z 101 TO 150 5 G
<br />c) c> v � Ui � z � � - - - � Oaf'
<br />Z Z 0 151 TO 200 6 36" MIN, 36" MIN. z \\\ �� �oA / ��F cio UR
<br />CAR PARKING VAN PARKING CAR PARKING ACCESS AISLE VAN PARKING CAR PARKING CAR PARKING z `f' o LO 201 TO 300 7 `� ,� �°q�. F pF U) W_ Q w z
<br />" A " " " ooco ( d \ i 'lfF <CnPWa00
<br />SPACE, 96 MIN. SPACE, 132 MIN. SPACE, 96 MIN. 9fi MIN. SPACE, 96 MIN. SPACE, 96 MIN. SPACE, 96 MIN. _� a 301 TO 400 8 _ ` �� d'
<br />n , n : n , e , a , » r " ¢ C- _ ��/l/C m (n W W 0 0 0 (n W
<br />(8'-0" MIN) (11 -0 MIN.) (8 -0 MIN.) (8'-0" MIN.) (8'-On MIN.) (8 -0 MIN.) (8'-0- MIN.) TYP. CURB RAMP S 1.-
<br />z 0 �' z
<br />_ CONSTRUCTION N= w = a LU W
<br />401 TO 500 9 vw>wwoawo
<br />501 TO 1000 2 PERCENT OF TOTAL ¢ w - wow
<br />ACCESS AISLE, ACCESS AISLE, < W ¢ - v 0 jE
<br />60 MIN. 60 MIN. 1001 AND OVER 20, PLUS 1 FOR EACH 100, OR cn cn ¢ I- }
<br />(5'-0" MIN.) (5'-0" MIN.) ACCESSIBLE VAN ACCESSIBLE FRACTION THEREOF, OVER 1000. ( w j o
<br />PARKING SIGN PARKING SIGN 0 0= w W¢ w �- W
<br />„ FOR EVERY SIX, OR FRACTION OF SIX PARKING SPACES REQUIRED oaf 0 2 v w m zD_
<br />ACCESSIBLE CAR AND VAN PARKING - OPTION A ACCESSIBLE CAR AND VAN PARKING - OPTION B ACCESSIBLE CAR PARKING 1 =1 -0 1 2 =1 -0 TO BE ACCESSIBLE, AT LEAST ONE SHALL BE BE A VAN DIAGONAL CURB RAMP PLAN = - f) � _ ? 0 --
<br />ACCESSIBLE PARKING SPACE. `) 0 w w
<br />rT_� ACCESSIBLE ROUTES -PARKING ACCESSIBLE RAISED ISLAND CROSSING - ACCESSIBLE RAISED ISLAND CROSSING - _ _ _ _ Cm
<br />CUT THROUGH ON LEVEL WITH STREET �16"=1-0") CURB RAMP AT ISLAND (3/16"=1-O'� i - _ _
<br />�10
<br />1/8"=V-0" (UNLESS NOTED OTHERWISE) I SAME WIDTH LANDING AREA: 1:48
<br />I AS CURB RAMP. i CROSS SLOPE (MAX.)
<br />(MIN.)
<br />� T �
<br />NOTES:
<br />PROVIDE ADA COMPLIANT
<br />1. INFORMATION SHOWN BELOW IS TO i DETECTABLE WARNING
<br />ILLUSTRATE THE MINIMUM REQUIREMENTS L-----_ --
<br />FOR ELEVATORS AND ELEVATOR LANDINGS. STRIP INSERT TO WARN
<br />2. ELEVATOR MANUFACTURER AND GUTTER/ROAD SURFACE CURB RAMP: CURB RAMP: OF HAZARDS ON A
<br />CONTRACTOR SHALL COMPLY WITH ALL THE IMMEDIATELY ADJACENT TO MAX RUN: 72" CIRCULATION PATH, SUCH
<br />REQUIREMENTS OF AMERICANS WITH CURB RAMP. 1:20 SLOPEIN. WIDTH: 36" AS CROSSING FROM A
<br />32" CLR. MIN. 32" CLR. MIN. (MAX.)( ) MAX. RISE: 6" 36" MIN. : aco PEDESTRIAN TO
<br />DISABILITIES ACT, SECTION 407 ELEVATORS, WHERE PROVIDED, CURB RAMP �'
<br />NOTES: AND ALL LOCAL AMENDMENTS TO SAID ACT. LANDING AREA:
<br />� VEHICULAR ZONE.
<br />FLARES (BEYOND) SHALL HAVE WHERE PROVIDED, CURB
<br />1. FLOOR AND GROUND SURFACES SHALL COMPLY 3. ELEVATOR MANUFACTURER AND 1:48 CROSS � z N_
<br />WITH 1,2,&3/GO10. CONTRACTOR SHALL PROVIDE ELEVATORS A 1:10 SLOPE (MAX) SLOPE (MAX.) Of � RAMP FLARES SHALL
<br />1.1. EXCEPTION: SLOPES NOT STEEPER THAN THAT FULLY COMPLY WITH THE _ _ a HAVE A 1:10 SLOPE
<br />1:48 SHALL BE PERMITTED. REQUIREMENTS OF ASME A18.1. 124'
<br />PROVIDE ADA COMPLIANT DETECTABLE WARNING °°°°°° ° °° ° 0°°°
<br />00000n000a00000000
<br />4. PLATFORM LIFE FLOORS SHALL COMPLY ALL ADJOINING SURFACES SHALL BE AT THE O°O°°°°°°°°°°°°°°° ( )
<br />2. ACCESSIBLE ROUTES SHALL COMPLY WITH STRIP INSERT TO WARN OF HAZARDS ON A ° ° ° ° ° ° ° ° ° ° 0 ° ° ° ° ° ° ° 1:10 SLOPE
<br />SAMELEVEL, TYP. 1:10 SLOPE 0000 00000000000000000
<br />9/G010. WITH 1,2,&3/G010. CIRCULATION PATH SUCH AS CROSSING FROM d- ° ° ° ° °
<br />5. PLATFORM LIFTS SHALL NOT BE ' `� 000000000000000
<br />000000noa00000aoao
<br />A PEDESTRIAN TO VEHICULAR ZONE.
<br />3. VERTICAL CLEARANCE: MIN. 114" (9'-6") MIN. r _ _ _ _ _ _ _ _ _ MIN. PLATFORM AREA r _ _ _ _ _ _ _ _ ATTENDANT -OPERATED AND SHALL PROVIDE ° 000
<br />00000000000000
<br />i SHALL BE PER 6/GO10 I i CURB RAMP SECTION °°°°°°°°°°°°°°°°°
<br />OI
<br />I I I UNASSISTED ENTRY AND EXIT FROM THE
<br />LIFT. 3 CURB RAMPS ON ACCESSIBLE ROUTES oRTHAGONAL CURB RAMP PLAN o
<br />6. DOORS AND GATES:
<br />ACCESS AISLE WIDTH z i I z i i M
<br />' w I I w 6.1. DOORS AND GATES SHALL HAVE LOW- G-0.10 3/8"=1'-0" (UNLESS NOTED OTHERWISE)
<br />SAME AS VEHICLE „
<br />a z CL I ENERGY POWER -OPERATED DOORS LANDING, RAMP RUN, 60 , LANDING, RAMP RUN, LANDING AT CHANGE
<br />PULL-UP SPACE LENGTH I i i "UJI 30" RISE0" RISEf AND GATES COMPLYING WITH NOTES 60 MIN. (MAX.)( ) 60 MIN. (MAX.)( IN DIRECTION, 60 MIN.
<br />IN 1/GO10.01. DOORS SHALL �� ^,�
<br />6.1.1. REMAIEX O PTIONPEN �RPLATFORMSECONDS MIN. _ - _ _ - "C�
<br />fi 12" HANDRAIL ^
<br />I i i SERVING TWO LANDINGS MAXIMUM EXTENSION, HANDRAILS MAY Q
<br />- - - - AND HAVING DOORS OR GATES TOP AND z ,,,., z
<br />ON OPPOSITE SIDES SHALL BE BOTTOM OF z
<br />PERMITTED TO HAVE EACH RAMP LANDING G AREAS < co
<br />D
<br />Uj CL z z AREA TO BE MARKED TO MIN. PLATFORM AREA SELF -CLOSING MANUAL DOORS RUN, TYP. M
<br />U J
<br />DISCOURAGE PARKING IN o
<br />in SHALL BE PER 6 G010 AND GATES. ¢ z Q
<br />' / NOTES: NOTES: _ _ _ - = c, M
<br />o THEM 6.2. END DOORS AND GATES SHALL n 1. EDGE PROTECTION NOT REQUIRED AT RAMPS THAT DO 1. A PIPE BARRIER CONDITION WHERE THE RAMP IS OPEN o OR I M
<br />N ° ( PROVIDE A CLEAR WIDTH OF 32 MIN. NOT REQUIRE RAILINGS AND FLARED SIDES CURB ON BOTH SIDES IS SHOWN. THE PIPE BARRIER IS
<br />( HANDRAILS REQUIRED AT RAMPS
<br />L - - - - - - - - - - - J 6.3. SIDE DOORS AND GATES SHALL RAMP) INTEGRAL TO THE RAILING IS SHOWN. A SOLID WITH RISER GREATER THAN 6"
<br />32" CLR. MIN. PROVIDE A CLEAR WIDTH OF 42" MIN. 2. EDGE PROTECTION IS NOT REQUIRED ON THE SIDES OF CONCRETE CURB, OR OTHER BARRIER IS ALSO
<br />ACCEPTABLE.
<br />VEHICLE PULL-UP RAMP LANDINGS SERVING AN ADJOINING RAMP RUN OR
<br />PLATFORM LIFT - PLATFORM LIFT - STAIR. 2. WHERE THE RAMP IS ENCLOSED BY A SOLID WALL ON NOTES: v ►--�
<br />SPACE LENGTH, ONE OR MORE SIDES, THE SOLID WALL ITSELF �1
<br />20'-0" MIN. FRONT AND SIDE PASSAGE FRONT AND REAR PASSAGE 3. EDGE PROTECTION SHALL NOT BE REQUIRED ON THE 1. RAMPS:
<br />SIDES OF RAMP LANDINGS HAVING A VERTICAL PROVIDES THE BARRIER. z w ►--�
<br />1.1. MIN. WIDTH: 36 CLEAR, BETWEEN THE HANDRAILS. = g
<br />6 ACCESSIBLE ROUTES -PASSENGER LOADING ZONES 5 ACCESSIBLE ROUTES - ELEVATORS DROP -OF OF EQU IN 1a" OF THE MINIMUM 1.2. MAX. RUNNING SLOPE: 1:12. a- W
<br />LANDING AREA REQUIRED. 1.3. MAX. RISE: 30" PER EACH RAMP RUN.
<br />3/16"=1'-0" 1.4. MAX. CROSS SLOPE: 1:48. o
<br />12" 1.5. CHANGES IN LEVEL OTHER THAN RUNNING SLOPE AND
<br />HANDRAIL CROSS SLOPE ARE NOT PERMITTED. w
<br />NOTES: 4. ELEVATOR FLOORS SHALL COMPLY WITH 1,2,&3/G010. EXTENSION, 2. LANDINGS: a I
<br />1. INFORMATION SHOWN BELOW IS TO ILLUSTRATE THE 5. ALL IN -CAR AND ELEVATOR DING BUTTONS SHALL BE TYP PROVIDE CURB OR 2.1. LANDINGS SHALL OCCUR AT AT THE TOP AND BOTTOM w
<br />MINIMUM REQUIREMENTS FOR ELEVATORS AND ELEVATOR FLUSH, OR RAISED DESIGN D SHALL PROVIDE VISIBLE BARRIER TO PREVENT SLOPE:
<br />EACH RAMP RUN. I---------------1 N
<br />SIGNALS. BUTTONS S BE 3/4 IN SMALLEST PASSAGE OF 4 SPHERE,
<br />LANDINGS. " 2.2. SLOPE: LANDINGS SHALL BE .LEVEL. CHANGES IN
<br />2. ELEVATOR MANUFACTURER AND CONTRACTOR SHALL DIMENSION, MIN. WHERE ANY PORTION OF n LEVEL ARE NOT PERMITTED. LANDINGS AND REQUIRED
<br />COMPLY WITH ALL THE REQUIREMENTS OF AMERICANS WITH 6. ALL IN -CAR AN LEVATOR LANDING SIGNALS SHALL THE SPHERE IS WITHIN 4 2.2.1. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 MANEUVERING CLEARANCES AT � i F•L�
<br />DISABILITIES ACT, SECTION 407 ELEVATORS, AND ALL INCLUDE VISI AND AUDIBLE SIGNALS. EACH SIGNAL OF THE GROUND. SHALL BE PERMITTED. DOORS ARE PERMITTED TO
<br />LOCAL AMENDMENTS TO SAID ACT. 12" 36" 12" 2.3. WIDTH: SAME WIDTH AS THE WIDEST PART OF THE OVERLAP. UPPER LANDING SIZE s w
<br />v J J SHALL B 1/2 IN THE SMALLEST DIMENSION, MIN. $o RAMP LEADING TO THE LANDING. MAY NEED TO BE INCREASED TO i i g
<br />HORIZONTALLY SLIDING ELEVATOR 3. ELEVATOR MANUFACTURER AND CONTRACTOR SHALL MIN. MIN. MIN. r,, '0 n A t
<br />PROVIDE ELEVATORS THAT FULLY COMPLY WITH THE FLOOR OR GROUND 2.4. LENGTH: 60 MIN. ACCOMMODATE THE OVERLAP.
<br />o DOORS REQUIREMENTS OF ASME A17.1. SURFACE EXTENSION 2.5. CHANGES IN DIRECTION: LANDING CLEAR DIMENSIONS
<br />o VISIBLE HALL SIGNAL, VERTICALLY i i Q1
<br />� Q � BEYOND OUTSIDE SHALL BE 60"x60". �
<br />SEE PLANS STACKED. ROUND AND ARROW SEE PLANS
<br />cn HORIZONTALLY SLIDING FACE OF RAILINGS. d 3. EDGE PROTECTION AT THE SIDES OF THE EXPOSED SIDES
<br />FOR WIDTH STYLE SHOWN FOR REFERENCE. FOR WIDTH
<br />z v- ELEVATOR DOORS v OF THE RAMP ARE REQUIRED, SEE ADJACENT DIAGRAMS.
<br />_ Z � REQUIREMENTS SECONDARY CONTROLS MAY CAR DESIGNATION TEXT, FLOOR DESIGNA110N REQUIREM ,�
<br />N C o OCCUR FOR SECURITY. WHERE INCLUDE SPECIAL TEXT, INCLUDE SPECIAL VISIBLE HALL SIGNAL, EDGE PROTECTION - EDGE PROTECTION -
<br />s POSSIBLE, LOCATE ON THE SYMBOLS AS REQUIRED. SYMBOLS AS REQUIRED. VERTICALLY STACKED. EXTENDED FLOOR OR GROUND SURFACE (A) CURB OR BARRIER (B) RAMP PLAN
<br />_ o ELEVATOR PANEL PLATE. IF NOT ROUND AND ARROW STYLE
<br />CD= = o _ LOCATE TO THE SIDE AS SHOWN. EQ. ��' 1, f__ A - SHOWN FOR REFERENCE. Z RAMPS ON ACCESSIBLE ROUTES
<br />z '- ¢ r � - FIRE DEPT. EMERGENCY = _
<br />z , OPERATIONS - `u `� z / 'IN CASE OF FIRE USE G-0:10 3/8"=1'-0"
<br />o a `"�'� I ,� J CAR CONTROL BUTTON �`'� I I STAIRWAY. DO NOT USE a
<br />ca �®'° J
<br />" ¢ ®OOO RAISED TEXT AND BRAILLE TO o C Pau -T i I ELEVATOR.' PICTOGRAPH AND �_
<br />N n BRAILLE COPY � BRAILLE C I I I TEXT. COMPLY WITH LOCAL "' NOTES: 8.3. NON -FIRE DOORS, SLIDING OR FOLDING DOORS: 5 LBS MAX.
<br />®O Q�� THE LEFT OF EACH GAR �11
<br />�O®O CONTROL BUTTON. INCLUDE � W +� EMIL -- I REQUIREMENTS. 0 1. REVOLVING DOORS, GATES, AND TURNSTILES SHALL NOT BE PART OF AN 8.4. THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO
<br />*' O ®O STAR GRAPHIC AT MAIN ENTRY z Q z w BRAILLE COPY. ACCESSIBLE ROUTE. RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD
<br />FLOOR. 'i o z_ z '* W 2. DOUBLE -LEAF DOORS AND GATES: AT LEAST ONE OF THE ACTIVE THE DOOR OR GATE OPEN. "
<br />ZE C.Da I o 48 CLR. MlN. 48 CLR. MIN.
<br />®�C O-1_-- EMERGENCY CONTROLS FOR: "' En a ; z FIRE DEPARTMENT LEAVES OF DOORWAYS WITH TWO LEAVES SHALL BE FULLY COMPLIANT 9. DOOR AND GATE SURFACES:
<br />o ®O®O DOOR OPEN DOOR CLOSE, Z (0 W � �> g z g z P� CONTROLS z_ WITH ACCESSIBILITY REQUIREMENTS. 9.1. SWINGING DOOR AND GATE SURFACES WITHIN la" OF THE FINISH
<br />�`- ^� EMERGENCY STOP, AND ALARM. 0- � 3 0 co CD d . ELEVATOR CALL 3. CLEAR DIMENSIONS AT DOOR AND WALL OPENINGS: FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH
<br />Z z N 0° o CONTROLS N 3.1. WIDTH: DOOR AND WALL OPENINGS SHALL PROVIDE A CLEAR WIDTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE
<br />o �� �.---- EMERGENCY TWO-WAY o o m '- ^ OF 32" MIN. CLEAR OPENINGS OF DOORWAYS WITH SWING DOORS DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS
<br />COMl- - - -� ANDMSP SPEAKER.
<br />CONTROLS m m SHALL BE MEASURED FROM THE FACE OF THE DOOR AND THE IN THESE SURFACES SHALL BE WITHIN 1/16" OF THE SAME PLANE K
<br />STOP WITH THE DOOR OPEN TO 90 DEGREES, OPENINGS MORE AS THE OTHER. CAVITIES CREATED BY ADDING KICK PLATES SHALL
<br />PedrlL SECONDARY CONTROLS MAY OCCUR FOR SECURITY. '
<br />THAN 24" DEEP SHALL PROVIDE A CLEAR OPENING OF 36" MIN. BE CAPPED.
<br />WHERE POSSIBLE, LOCATE ON THE ELEVATOR PANEL 3.2. VERTICAL' THE MINIMUM VERTICAL CLEARANCE FROM THE FINISH 9.1.1. EXCEPTTON1: SLIDING DOORS SHALL NOT BE REQUIRED TO SWINGING IN SAME DIRECTION (A) SWINGING AWAY FROM EACH OTHER (B)
<br />NOTE: SIGNAGE SHALL BE NOTE: SIGNAGE SHALL BE PLATE. IF NOT LOCATE TO THE SIDE AS SHOWN. FLOOR TO THE BOTTOM OF THE DOOR FRAME IS 80" MIN. COMPLY.
<br />PROVIDED ON BOTH JAMBS PROVIDED ON BOTH JAMBS ALIGN VERTICALLY WITH VISIBLE HALL SIGNAL AT
<br />OF EACH ELEVATO OF EACH ELEVATOR. 3.3. PROJECTIONS INTO THE CLEAR OPENING: PROJECTIONS INTO THE 9.1.2. EXCEPTION 2: TEMPERED GLASS DOORS WITHOUT STILES AND
<br />SINGLE ELEVATORS. AT MULTIPLE ELEVATORS USING CLEAR OPENING WIDTH BETWEEN 34" AND 80" ABOVE THE FINISH HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE `°� ()F.Fto
<br />THE SAME CONTROLS, CENTER CONTROLS HORIZONTALLY TAPERED AT 60 DEGREES MINIMUM FROM THE HORIZONTAL a. s �
<br />BETWEEN THE ELEVATOR DOORS. FLOOR OR GROUND SHALL NOT EXCEED 4.
<br />3.3.1. EXCEPTION: DOOR CLOSERS AND DOOR STOPS SHALL BE SHALL NOT BE REQUIRED TO MEET THE 10" BOTTOM SMOOTH " .' Q
<br />PERMITTED TO BE 78" MIN. ABOVE THE FINISH FLOOR OR SURFACE HEIGHT REQUIREMENT. 48 CLR. MIN.
<br />GROUND. 9.1.3. EXCEPTION 3: DOORS AND GATES THAT DO NOT EXTEND TO 140
<br />CAR S AMBS FLOOR DESIGNATIONS ON JAMBS 4. FLOOR AND GROUND SURFACE AT REQUIRED MANEUVERING CLEARANCES WITHIN 10" OF THE FINISH FLOOR OR GROUND SHALL NOT BE
<br />IN -CAR CONTROL BUTTONS AND EMERGENCY CONTROLS OF DESTINATION-O HOTS Y ENTRANCES 54" MIN. OF ELEVATOR HOISTWAY EN CES ELEVATOR LANDING DOOR ELEVATION REQUIRED TO PROVIDE SMOOTH SURFACES PROVIDE THAT IF lk SHALL COMPLY WITH 9/G010. CHANGES IN LEVEL ARE NOT PERMITTED. ADDED KICK PLATES ARE INSTALLED, CAVITIES CREATED BY
<br />36 MIN. 4.1. EXCEPTION 1: SLOPES NOT STEEPER THAN 1:48 SHALL BE
<br />r :, „ ., 60" MIN.
<br />PERMITTED. SUCH KICK PLATES ARE CAPPED.
<br />4.2. EXCEPTION 2: CHANGES IN LEVEL AT THRESHOLDS COMPLYING WITH 10. VISION LITES:
<br />80" MIN. 68" 3/G010 SHALL BE PERMITTED. 10.1. DOORS, GATES, AND SIDE LIFTS ADJACENT TO DOORS OR GATES, SWINGING TOWARDS EACH OTHER (C)
<br />5. THRESHOLDS. SEE 3/G010.
<br />CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING
<br />t
<br />k THROUGH THE PANELS SHALT HAVE THE BOTTOM OF AT LEAST ONE
<br />6. DOOR D GATE HARDWARE: »
<br />u..
<br />.,.. ._ CLEARANCES AT HINGED DOORS IN SERIES G 00 S SE S
<br />GLAZED PANEL LOCATED 43 MAX. ABOVE THE FINISH FLOOR.
<br />«..:<.
<br />6.1. DOOR HANDLES, PULLS LATCHES LOCKS AND OTHER OPERABLE
<br />.,.... ... ,,.,..„ .,,.. .n...,.,, a.. ... ,,. ,._.....,., ., ... ., rv. ...... x,„. .,,.. ..._,. ..-,. .... .... .x. ... .. ,. _........ .. .,4..,_ru ,.ax._..-. .r �. a. .z,,::....., i__„,_ ,...-. ,_:r ,....,.a .., ..,. ...»s,_ :, _. ....,... _.. .
<br />PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT 10.2. EXCEPTION. VISION LIGHTS WITH THE LOWEST PART MORE THAN C,
<br />66 FROM THE FINISH FLOOR OR GRAND SHALL NOT BE REQUIRED N
<br />---�-® {_ 16 S.F. REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. ______________ _________ _______
<br />o-"
<br />THE FORCE REQUIRED TO ACTIVE OPERABLE PARTS SHALL BE 5L.BS TO COMPLY. r r r --� occ
<br />- (MIN.) 11. AUTOMATIC AND POWER ASSISTED DOORS:
<br />Z
<br />MAX
<br />k 11.1. FULL -POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI BHMA
<br />R , 6.2. OPERABLE PARTS OF DOOR HARDWARE SHALL BE 34" MIN. AND 48" / �L
<br />` z MAX. ABOVE THE FINISH FLOOR OR GROUND. A156.10. i �/
<br />z tL2. LOW -ENERGY AND POWER -ASSISTED DOORS SHALL COMPLY WITH
<br />M 6.3. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, z z z
<br />k - " o d OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH ANSI/BHMA A156.19. I I I
<br />I i I 1 I
<br />,�, °� £_ 11.3. CLEAR WIDTH: DOORWAYS SHALL PROVIDE A CLEAR OPENING OF
<br />SIDES. o I o I I o I
<br />6.4. EXCEPTION: ACCESS GATES IN BARRIER WALLS AND FENCES 32" MIN. IN POWER -ON AND POWER -OFF MODE. THE MIN. CLEAR `n I oo `� I co `� I I ao
<br />x PROTECTING POOLS, SPAS, AND HOT TUBS SHALL BE PERMITTED TO WIDTH FOR AUTOMATIC DOOR SYSTEMS IN A DOOR WAY SHALL BE i ^ i i ^ i 12 i ^ Q
<br />1, : > £ram. 2",
<br />k' O
<br />' HAVE OPERABLE PARTS OF THE RELEASE OF LATCH ON BASED ON THE CLEAR OPENING PROVIDED BY ALL LEAVES IN THE 18 MIN. x ; i x �Y ,�' SELF -LATCHING DEVICES AT 5e MAX. ABOVE FINISH FLOOR OR OPEN POSITION.
<br />I_
<br />x
<br />11.4. MANEUVERING CLEARANCES. CLEARANCES AT POWER -ASSISTED , r.
<br />GROUND PROVIDED THE SELF -LATCHING DEVICES ARE NOT ALSO
<br />.. <.r.,. x.., x:;.. �.:>. ,. ..: ,.M.,.. � s:
<br />..:,. �..N-:.. �..., ... �.:. Q•,.,,,, :.,ry .e...,
<br />..,t,...,. .o.... ..�.. "; ..s.. .n,., ..y:,..r.,.c
<br />� .- ,,.. ,�.�,�, » r. ���, _ DOORS AND GATES SHALL COMPLY WITH THE CLEARANCES NOTED
<br />SELF-LOCKING DEVICES AND OPERATED BY MEANS of A KEY
<br />.x _....
<br />xr .,
<br />.. ...,...._ ,.. ,.. ram. ... ...,. ,,.. .... , <,,.. ». .. ... 4... .d � .... ,. .. ..,- ., w�.. .. ... ..,:,.. .. .- ...., .,.....,. x. 9 .. .. x. .. ,.. ,. „.,.s... ..,... ,......
<br />OR THE UAL DOORS AND GATES. CLEARANCES AT AUTOMATIC F MAN R EARAN
<br />_ � . � ._ _ � ,. � .. r. ��� ., �, 0 0 I TION LOCK. � � » *,_ ... . ELECTRONIC OPENER R INTEGRAL C MB NA CK. _ � � �. �xr F, � TR
<br />.:,,. ,....... _ ., . .: � k .. . .. ... ... ,. , ,.... , ., to , �., ..
<br />....,� * rv.• ,,.»... *_ 7. CLOSING SPEED: DOORS AN GATES WITHOUT STANDBY POWER AND SERVICING AN 0
<br />ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THE "-
<br />I 7.1. DOOR AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN
<br />OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE CLEARANCES NOTED FOR THE MANUAL DOORS AND GATES. w ci
<br />42" MIN. 36" MIN. i i 36" MIN. i 36" MIN.' i i i DOOR TO POSITION OF 12 DEGREES FROM THE LATCH IS 5 11.4.1. EXCEPTION: WHERE AUTOMATIC DOORS AND GATES REMAIN Cl) z
<br />ELEVATOR
<br />LANDING CALL ! I SECONDS MIN. OPEN IN THE POWER -OFF CONDITION, COMPLIANCE WITH -
<br />STATION, TYP. i i i i i i i i 7.2. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT MANUAL DOOR CLEARANCES ARE NOT REQUIRED.
<br />I I I I I I FROM THE OPEN POSITION OF 70 DEGREES, THE 11ME REQUIRED TO 11.5. MANUALLY OPERATED CONTROLS SHALL COMPLY WITH THE SAME Sheet Name:
<br />�- MIN. MANEUVERING i i MOVE THE DOOR OR GATE TO THE CLOSED POSITION IS 1.5 REQUIREMENTS AS MANUALLY OPERATED DOORS. ACCESSIBILITY STANDARDS
<br />i CLEARANCE AT ELEVATOR i I I E i i i I SECONDS MIN. 11.6. BREAK OUT OPENING: WHERE DOORS AND GATES WITHOUT STANDBY PUSH SIDE, DOOR PROVIDED WITH
<br />LANDING CALL STATION, SEE I I 8. DOOR AND GATE OPENING FORCE: POWER ARE A PART OF A MEANS OF EGRESS, THE CLEAR BREAK FRONT APPROACH, PULL SIDE (A) FRONT APPROACH, PUSH SIDE (B) BOTH A CLOSER AND A LATCH (C)
<br />L-_----_J L-------J L - - - � L--------' L------- ' 8.1. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE OUT OPENING AT SWINGING AND SLIDING DOORS AND GATES SHALL
<br />6/G010. NO ITEMS
<br />PERMITTED IN THIS SPACE. THE AUTHORITY HAVING JURISDICTION. BE 32" MIN. WHEN OPERATED IN EMERGENCY MODE. Proj #: Issue Date:
<br />E OR CAR MINIMUM CAR ELEVATOR CAR MINIMUM CAR ELEVATOR CAR MINIMUM CAR ELEVATOR CAR MINIMUM CAR ELEVATOR CAR MINIMUM CAR 8.2. NON -FIRE DOORS, INTERIOR HINGED DOORS AND GATES: 5 LBS FRONT APPROACH MANEUVERING 210316 09/01 /2022
<br />DIM IONS - CENTERED DOOR (A) DIMENSIONS - CENTERED DOOR (8) DIMENSIONS - ANY DOOR LOCATION (C) DIMENSIONS - ANY DOOR LOCATION (D) DIMENSIONS -ANY DOOR LOCATION (D) Mg. CLEARANCES AT RECESSED DOORS AND GATES Sheet No.:
<br />_
<br />4 ACCESSIBLE ROUTES - ELEVATORS ACCESSIBLE ROUTES DOORS, GATES, AND WALL OPENINGS (CONTINUED) G-00 10
<br />�10
<br />3/16"=1'-0" �-10
<br />G3/8"=l'-0" Drawn By: Checked By:
<br />DL DS
<br />ISSUED FOR CONSTRUCTION
<br />T-i, 11 .11 1 i
<br />
|