Laserfiche WebLink
_DRAWING2022 38111 INDEX <br />REVISIONS <br />- J51 <br />GN1.0 Cover Sheet <br />WOMEN S0V�STI9ULE��CIS BUILDING BB20 <br />4 � �JE -; �� I GN 1 .1 General Notes <br />LS1.0 Life Safety <br />STORAGE <br />ATLANTA FIELD OFFICE z <br />FREEZER R �j (� l J - - <br />- - o a �; <br />-- �e REFERENCE <br />I I I <br />CY <br />-I - - r ---- D ' , BUILDING INFORMATION: DT1 .0 Drive-Thru Plan & Details Cn <br />W <br />--� i S '---- 2 -JAN <br />8---�-'C 'I ADDRESS: �f <br />ARCHITECTURAL <br />COOLER r - <br />STATE SITE CODE: 09-2721 A1.0 Floor Plan <br />° - NATIONAL STORE NUMBER: 40871 <br />C) �� -- I I I STREET ADDRESS: 7557 GALL BLVD. A1.2 Reflected Ceiling Plan <br />CUSTOMER ; ` _ I I 1 I CITY: ZEPHYRHILLS A1.3 Roof Plan <br />III KITCHEN <br />COUNTY: PASCO _ _ A2.0 Elevations <br />- J <br />SUPPORT _ --5 -� ��; I I STATE: FL A2.1 Elevations < <br />MECHANICAL ° <br />CJ _ a 'Y, I I ZIP: 33541 - o <br />A3.1 Customer Service Pod Details <br />STRUCTURE: A4.0 Enlarged Restroom Plan & Details <br />u ARIENTER-1 II MASONRY LOAD BEARING WALLS A4.1 Enlarged Plan Details I <br />'CREW ROOM OFFICE _ ORDER <br />\ J PRESENTS_; STEEL JOIST ROOF FRAMING A5.0 Wall Sections & Details <br />UTILITIES: A5.1 Wall Sections & Details <br />I I I I I I <br />ELECTRIC GRILLS & ELECTRIC FRYERS A5.2 Wall Sections & Details <br />A5.3 Wall Sections & Details <br />GAS HVAC & GAS WATER HEATER Date:moo* 0 ' :: • <br />BUILDING CODE: A6.0 Door & Hardware Schedules f • :73:�+��oo,. <br />A6.1 Finish Schedules ��`��'. <br />1 KEY FLOOR PLAN 'sT; --••••••---�;`� <br />BUILDING CODE: 2020 FBC-BUILDING, 7TH EDITION - IBC 2018 w/AMENDMENTS RFD Po <br />GN1.0 SCALE: 1/8" = 1'-O" EXISTING BUILDING CODE: 2020 FBC-EXISTING BUILDING, 7TH EDITION - IEBC 2018 <br />NORTH w/AMENDMENTS STRUCTURAL <br />MECHANICAL CODE: 2020 FBC-MECHANICAL, 7TH EDITION - IMC 2018 w/AMENDMENTS S1.0 Foundation Plan <br />PLUMBING CODE: 2020 FBC-PLUMBING, 7TH EDITION - IMC 2018 w AMENDMENTS THIS DOCUMENT AS <br />2 / S1 .2 Roof Framing Plan BEEN DIGITALLY SIGNED <br />REVIEW DATE.. ELECTRICAL CODE: 2017 NATIONAL ELECTRICAL CODE OF FLORIDA - NFPA 70, 2017 AND SEALED. PRINTED <br />CITY OF ZEPHYRHIL S S2.0 Foundation Sections <br />ALL WORK SHALL COMPLY WITH PREVAILING ENERGY CODE: 2020 FBC-ENERGY CONSERVATION, 7TH EDITION - IECC 2018 COPIES of THE <br />53.0 Framing Sections DOCUMENT ARE NOT <br />CODES FLORIDA BUILDING CODE BUILDING OFFICIA w/AMENDMENTS - -- CONSIDFRFD SIGNED ANI) <br />NATIONAL ELECTRIC CODE, S 3.1 Framing m i n Sections <br />AND THE CITY OF ZEPHYRHILLS FIRE CODE: 2020 FFPC - NFPA 1 AND NFPA101 w/AMENDMENTS g SEALED. THE SIGNATURE <br />ORDINANCES FUEL/GAS CODE: 2020 FBC-FUEL GAS, 7TH EDITION - IFGC 2018 w/AMENDMENTS S3.2 Framing Sections MUST eE VERIFIED ON <br />ANY ELECTRONIC COPIES <br />ACCESSIBILITY CODE 2020 FBC-ACCESSIBILITY, 7TH EDITION S4.0 General Notes OF IHE DOCUMENT <br />........ <br />2010 ADA STANDARDS 08.11.2023 <br />BUILDING DATA: MECHANICAL DATE <br />OCCUPANCY: USE GROUP A2 - ASSEMBLY CONSTRUCTION M1.0 Mechanical Roof Plan <br />SITE Ce <br />OCCUPANCY ALLOWANCE: TYPE: VB M1.2 Ductwork Plan <br />2020 FBC-BUILDING, 7TH EDITION NUMBER OF STORIES: 1 M1.4 Mechanical Piping Plan Z) <br />,. TABLE 1004.5 BUILDING HEIGHT: 18'-9 1 /2" (MAIN BLDG. PARAPET) M2.0 Exhaust Hoods Ln g <br />- MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT BUILDING AREA: 4,115 S.F. <br />M3.0 Mechanical Details 0 M W <br />iJ sag* ; aenral o <br />- Li ►- Q rn <br />M4.0 General Notes Ln r"`x` 1Y'�'k FUNCTION OF SPACE ALLOWANCE AREA OCCUPANTS `" " " <br />DESIGN LOADS: M4.1 Mechanical Schedules o <br />ACCESSORY STORAGE AREAS, 0° �`~ � _j tj co <br />MECHANICAL EQUIPMENT ROOM 300 GROSS 540 SF 2 GROUND SNOW LOAD: 0 PSF o w J <br />"e�"c'��"'"` £""M�^'''1' ASSEMBLY WITH FIXED SEATS <br />WIND SPEED: 140 MPH. (ULTIMATE) EXPOSURE C `� L" <br />SEE PLAN - 64 PLUMBING w it tA o <br />- DINING SEISMIC DESIGN CATEGORY: A REVIEW DATE 5 ' ` S - �u 1N <br />°a <br />ASSEMBLY W/OUT FIXED SEATS SOIL BEARING CAPACITIES: 1 ,500 PSF ASSUMED CITY OF ZEPHYRHILLS P1 .0 Domestic Water Piping <br />STANDING SPACE 5 NET 10 0 S F 2 0 ( ) FIRE AND LIFE SAFETY EXAMIN <br />P1.2 Waste Vent & Storm Piping Plan N4-' J 0 Q, <br />ENERGY CRITERIA. P1.4 Underground Rough -in o o <br />BUSINESS AREAS L <br />150 GROSS 76 SF 1 a ° <br />CLIMATE ZONE: 2A WARM HUMID P1 .6 Overhead Rough -in `- (� v ° N �0 <br />KITCHENS COMMERCIAL U d � ° ° <br />17 P2.0 Domestic Water Isometric U � ° ao <br />ROOF: R-25 CI o ° f <br />(BASED ON FULL STAFF) MASONRY WALLS: R-5.7 Cl P2.1 Waste & Vent Isometric o, ' `' ° J a 3 - ° N <br />Y TOTAL OCCUPANCY ALLOWANCE 104 OPAQUE DOORS: U-0.61 ° N Ny <br />ALL WORKSW�LLCUIVINLYWITH P2.2 Storm Isometric <br />(FIXED): = NFFA CODES AND STANDARDS P 3.0 Details t a i I s -, .c ° C <br />�t Y- FENESTRATION FIXED U-0.50 N <br />ACCESSIBLE SEATING: 64 x 5% = 4 REQUIRED, 4 PROVIDED FENESTRATION (OPERABLE): U-0.65 P4.0 General Notes ° °' <br />NOTE: DINING AREA SHALL HAVE MAXIMUM OCCUPANT LOAD POSTED IN A ENTRANCE DOORS: U-0.77 <br />i •-J � L o O o O� O <br />P4.1 Schedules v �, ° a ° <br />NOTICEABLE PLACE NEAR THE MAIN ENTRANCES TO THE DINING AREA WINDOWS SHGC: SEW: 0.25, N: 0.33 (WITHOUT CANOPY, PF=O) a o c �, o <br />SEW: 0.30, N: 0.37 WITH CANOPY, 0.2<PF<0.5 ° ° �: <br />- TO BE SUBMITTED UNDER SEPARATE PERMIT: r a �~ <br />ELECTRICAL - c� <br />LIFE SAFETY SYSTEM. U1.2 o N o <br />• RADIO COMMUNICATION ENHANCEMENT SYSTEM (RCES) EMERGENCY LIGHTING: YES NO _ E1.0 POS Electrical Riser Diagram Y - ° , <br />0 rn "C " o a> .y <br />VICINITY MAP: ®® <br />EXIT SIGNS: <br />NORTH KITCHEN HOOD SUPPRESSION SYSTEMS �_ YES NO _ E1.1 Rough In Floor Plan � •� 0 ° � N � o ` <br />FIRE ALARM: YES _X NO E2.0 Lighting Plan & Schedule O ° L <br />DUCT SMOKE DETECTORS W AUDIBLE VISIBLE DEVICE: YES NO �L <br />/ / �- E2.1 Electrical Roof Plan o o ` <br />PUBLIC HEALTH NOTES. FIRE SPRINKLERS: YES NO E3.0 Electrical Schedule �� <br />SPRINKLER FLOW/TAMPER SWITCH W/ AUDIBLE/VISIBLE DEVICE: __ YES NO v ; , <br />CO2 DETECTION SYSTEM W/ AUDIBLE/VISIBLE DEVICE: X YES NO E3.1 Electrical & Lighting Notes \�.. a o- `� a ° <br />PANIC HARDWARE: �_ YES NO _ E3.2 Interlock Diagrams � a ~ a3� �` "� <br />1. IF FOOD PREPARATION AND RENOVATION WORK ARE TO OCCUR AT THE SAME TIME, A BARRIER HA E4.0 Wiring Details �` W <br />BETWEEN CONSTRUCTION AND FOOD PREPARATION ARLAS SHALL BE ERECTED PRIOR TO THE START OF - - a } o M <br />ANY WORK. THE BARRIER MUST BE SUFFICIENT TO ELIMINATE ALL DUST AND DEBRIS FROM ENTERING FIRE EXTINGUISHERS (MINIMUM ): E4.1 Lighting Controls Lj <br />m ( o o 0 <br />THE FOOD PREPARATION AREAS. SPECIAL CARE MUST BE TAKEN IF H.V.A.C. WORK IS CONDUCTED. E4.2 Electrical Utilities Distribution z m "'I W cv <br />i <br />2. ANY OPENINGS IN THE EXTERIOR BUILDING ENVELOPE MUST BE SEALED TO PREVENT VECTOR/RODENTS (1) 1 0# CLASS ABC WITH UL RATING 4A-60BC, o 0 0 o <br />ACCESS. MOUNTED IN SUPPORT AREA a <br />1 1.8 GALLON CLASS K WITH UL RATING C CD N <br />3. IF WATER SERVICE IS INTERRUPTED AT ANY POINT DURING RENOVATION, ALL SUPPLY LINES INCLUDING ( ) ( ) KITCHEN E Q U I P M E N T <br />TO THE ICE MACHINE SHALL BE FLUSHED. 1 -A:K (A) 2-A:K MOUNTED IN KITCHEN AREA M <br />K 1 .0 Kitchen Cover Sheet m <br />4. IF THE GREASE INTERCEPTOR IS IN A TRAFFIC AREA, THE MANHOLE LIDS SHALL BE RATED FOR DESIGNER OF RECORD: K2.0 Kitchen Equipment Plan I <br />TRAFFIC. C D <br />K2.1 Kitchen Equipment Schedule z <br />5. PLEASE REFER TO A6.1 FOR ROOM FINISH SCHEDULE, WALL TILE SCHEDULE AND FLOOR TILE DISCIPLINE: NAME: ADDRESS: LICENSE #: PHONE #: o <br />SCHEDULE FOR ANY ROOMS THAT WILL BE RENOVATED. ALL EXISTING ROOMS NOT INCLUDE IN SCOPE <br />SHALL KEEP EXISTING FINISHES WHICH ARE NOTED ON THESE SCHEDULES AS WELL FOR REFERENCE ARCHITECT: MARK SMITH 70 MANSELL COURT, SUITE 200, ROSWELL, GA 30076 AR101675 269-332-4691 iD <br />OF WHAT THOSE FINISHES ARE. marksmith®axiscompanies.com Z w n <br />m < o <br />(7 d V J <br />STRUCTURAL: PATRICK KELLY 70 MANSELL COURT, SUITE 200, ROSWELL, GA 30076 85562 678-395-4920 cr < W m <br />FOR PUBLIC HEALTH REVIEW THESE FINISHES ARE AS FOLLOWS: C W Q <br />patrickkelly®axiscompanies.com Q m o < <br />FLOOR WALL COVE BASE CEILING - p <br />ALL KITCHEN AREA QUARRY TILE FRP/TILE (SEE DETAILS) COVED QUARRY TILE 2x2 VINYL FACE TILE z o o z W <br />(BEHIND COUNTER AREA): MECHANICAL: MICHAEL PENNA 70 MANSELL COURT, SUITE 200, ROSWELL, GA 30076 96294 678-395--4920 Q I o¢ w ,n <br />michoelpenno0axiscompanies.com I- ; Q � <br />DRY STORAGE: QUARRY TILE FRP COVED QUARRY TILE 2x2 VINYL FACE TILE PROJECT MANUAL V? z r - m <br />TOILET ROOMS: PORCELAIN TILE TILE SEE DETAILS SCHLUTER DILEX-AHK BSS PAINTED MOIST. GYP. o < o <br />( ) PLUMBING: MICHAEL PENNA 70 MANSELL COURT, SUITE 200, ROSWELL, GA 30076 96294 678-395-4920 a z <br />THESE DRAWINGS AND THE 2023 PROJECT MANUAL - N E 0 W U o <br />ELECTRICAL: MICHAEL T. ODUSELU 70 MANSELL COURT, SUITE 200, ROSWELL, GA 30076 88126 678-395-4920 - , CD UD w N <br />michaeloduselu®axiscompanies.com in MCDONALDS STANDARD BUILDING PROGRAM - ARE INTENDED cv ►� o �' �' o <br />CONSTRUCTION PROJECT MANAGER: TO DESCRIBE AND PROVIDE FORA FINISHED PIECE OF WORK. NSN#: 40871 <br />PHONE #: THEY ARE INTENDED TO BE COOPERATIVE, AND WHAT IS CALLED o <br />NAME: ADDRESS: FOR BY EITHER WILL BE AS BINDING AS IF CALLED FOR BY Z <br />SITE PLAN: ®® MANAGER: Jason Sawall McDonald's USA LLC I Wesley Chapel, FL 33543 813-344-7972 BOTH. THE PROJECT MANUAL FOR IS AVAILABLE THROUGH THE G 1 *0 NORTH jason.sowall®us.mcd.com MCDONALDS ACM OR ECM. V' COVER SHEET <br />