My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7495 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7495 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:45:19 PM
Creation date
2/18/2025 3:41:36 PM
Metadata
Fields
Template:
Building Plans
Street #
7495
Location
Gall Blvd
Contractor
Southland Construction
Building Plans - Permit #
8088
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SLOPE TOP PLATE FOR POSITIVE <br />DRAINAGE TOWARDS ROOF <br />HOT AIR WELD <br />MEMBRANE FLA <br />ROOF MEMBRAI <br />PROVIDE EDGE <br />AND SEAM CAL <br />1 DETAIL- FASCIA ® PARAPET <br />).0 1 1/2" = 1'-0" <br />ROOFING ASSEMBLY <br />(SEE SHEET A1.3) <br />ROOF JOISTS - <br />(SEE STRUCTURAL <br />DRAWINGS) <br />1 /2" GYP. BOARD To -- <br />UNDERSIDE OF JOIST <br />BEARING <br />CEILING AS <br />SCHEDULED <br />TILE OVER 1 /2" - <br />CEMENT BOARD. SEE <br />DECOR DRAWING FOR <br />MORE INFORMATION <br />AND EXTENT <br />FLOOR FINISH AS <br />SCHEDULED <br />n <br />1 <br />A5.0 <br />,--- - - - - <br />I I <br />I I <br />I I <br />I I <br />I i <br />I I <br />I I <br />- I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />'lI <br />3 <br />A5.1 SIM. <br />1 <br />I <br />WALL SECTION - RESTROOM <br />3/4" = 1'-0" <br />CONT. SEALING STRIP ADHERED <br />TO WOOD BLOCKING <br />CONT. NON -CURING SEALANT <br />CONT. 2x WOOD BLK'G. SLOPED <br />TOWARDS ROOF <br />PRE-FAB ANCHOR-TITE FASCIA <br />WITH 24 GA PRE -FINISHED COVER BY <br />METAL -ERA (SEE ELEVATIONS FOR <br />COLOR) <br />EXTEND ROOFING MEMBRANE UP <br />BACKSIDE PARAPET TO UNDERSIDE <br />OF FASCIA, (SEE A1.3 FOR ROOFING <br />NOTES) <br />EXTERIOR WALL ASSEMBLY 1 C <br />(SEE ASSEMBLY NOTES) <br />ROOFING ASSEMBLY <br />(SEE NOTES ON SHEET A1.3) <br />T <br />tPARAPET BLOCKI <br />ELEV. + 18'-9 1, <br />McDONALD'S FASCIA SIGN BY <br />OTHERS & UNDER SEPARATE <br />PERMIT (COORDINATE <br />STRUCTURAL AND ELECTRICAL <br />REQUIREMENTS) <br />PENETRATION AT <br />CORRUGATED METAL <br />PER MANUFACTURER'S <br />RECOMMENDATION <br />ELEV. +13'-4 <br />EXTERIOR WALL ASSEMBLY 1 C - <br />CMU (SEE ASSEMBLY NOTES) <br />LIGHT FIXTURE <br />(SEE ELECTRICAL DRAWINGS) <br />EXTERIOR WALL ASSEMBLY 1 C - <br />BRICK (SEE ASSEMBLY NOTES) <br />TYPICAL FOUNDATION AND <br />CONCRETE SLAB (SEE <br />STRUCTURE DRAWINGS) <br />SIDEWALK (SEE CIVIL <br />DRAWINGS) <br />TOP OF SLAB <br />ELEV. t0'-0" <br />SLOPE TOP PLATE FOR POSITIVE <br />DRAINAGE TOWARDS R <br />CONT. SEALING STRIP ADHERED <br />TO WOOD BLOCKING <br />CONT. NON -CURING SEALANT <br />401111111pZsPPPERRNin <br />CONT. 2x WOOD BLK'G. SLOPED <br />TOWARDS ROOF <br />PRE-FAB ANCHOR-TITE FASCIA <br />WITH 24 GA PRE -FINISHED COVER BY <br />METAL -ERA (SEE ELEVATIONS FOR <br />COLOR) <br />EXTEND ROOFING MEMBRANE UP <br />BACKSIDE PARAPET TO UNDERSIDE <br />OF FASCIA, (SEE A1.3 FOR ROOFING <br />NOTES) <br />EXTERIOR WALL ASSEMBLY 1 D <br />(SEE ASSEMBLY NOTES) <br />2 DETAIL- FASCIA � BATTEN PARAPET <br />ROOFING ASSEMBLY <br />(SEE SHEET A1.3) <br />ROOF JOISTS <br />(SEE STRUCTURAL <br />DRAWINGS) <br />CEILING AS <br />SCHEDULED <br />1 /2" GYP. BOARD TO <br />UNDERSIDE OF JOIST <br />BEARING <br />WALL FINISH AND <br />FLOOR FINISH PER <br />DECOR DRAWINGS <br />FLOOR FINISH AS <br />SCHEDULED <br />G � d <br />a <br />T/PARAPET BLOCKING <br />ELEV. +18'-9 1/2- <br />EXTERIOR WALL ASSEMBLY 1 C <br />(SEE ASSEMBLY NOTES) <br />T JOIST BEARING <br />3 <br />ELEV. +13'-4" <br />STEEL BEAM <br />A5.3 (SEE STRUCTURAL DRAWINGS) <br />SIM. <br />CANOPY & FASCIA SYSTEM <br />w/ TIE BACKS <br />' I <br />i <br />I T WINDOW & B CANOPYjk <br />- - - - - - - - - - - - - ELEV. + 9'-4" <br />A5.0 <br />6 WALL SECTION - DINING ROOM <br />D5:.O 3/4" <br />EXTERIOR WINDOW ASSEMBLY <br />(SEE ASSEMBLY NOTES) <br />SIDEWALK (SEE CIVIL <br />DRAWINGS) <br />TOP OF SLAB <br />ELEV. f0'-On <br />TYPICAL FOUNDATION AND <br />CONCRETE SLAB (SEE <br />STRUCTURE DRAWINGS) <br />EXTERIOR WALL ASSEMBLIES <br />FROM EXTERIOR TO INTERIOR <br />a LIGHT FIXTURE MOUNTED ON WALL. CENTER ON LOWEST 1A. NOT USED <br />° - "---� FULL METAL PANEL. COORDINATE RECESSED J-BOX 18. NOT USED <br />`---' r WITH BRICK & METAL INSTALLER. 1C. STUCCO SYSTEM <br />° - (SEE ELECTRICAL DRAWINGS) 1. DRYVIT COMMERCIAL CEMENT PLASTER (CCP) 3, CEMENTITIOUS STUCCO <br />° --- CONTINUOUS SEALANT - PROVIDE BACKER ROD WHERE VENEER WITH EXPANDED METAL OVER WEEP SCREED. <br />TRELLIS IS NOT FLUSH WITH WALL SURFACE 2. OVER WALL ASSEMBLY 2. <br />LED LIGHT FIXTURE 1 p, VERTICAL BATTEN SYSTEM <br />(SEE ELECTRICAL DRAWINGS) 1. ALUMINUM BATTEN W/MOUNTING BACK RAIL SIZE: 2" WIDE x 2" DEEP. <br />° a 2" TYP 0 REFER TO EXTERIOR ELEVATIONS FOR COLOR. INSTALL PER LOCAL <br />° CANOPY FASCIA SYSTEM CODES AND MANUFACTURERS SPECIFICATIONS ON TERMINATION AND <br />SEE ASSEMBLY NOTES) INSTALLATION DETAILS. <br />( 2. 1 /2" EXTERIOR HIGH DENSITY OVERLAY (HDO) PLYWOOD, BB, GROUP 1. <br />__---_ -- I HDO BOTH FACES. APA TRADEMARKED. SAND WITH COURSE GRIT ALL <br />SURFACES PRIOR TO PRIMING. PRIME AND PAINT BOTH SIDES AND ALL <br />EDGES. BY GC, INSTALL BY GC. ALUM EDGE TRIM BY GC. COLOR TO <br />I MATCH SUBSTRATE. <br />° SEE STRUCTURAL DRAWINGS FOR 3. 1" 0.125 ALUMINUM CHANNEL. BY GC, INSTALL BY GC <br />BOLT ATTACHMENT 4. OVER WALL ASSEMBLY 1A <br />1 E. ALPOLIC ACM PANEL <br />3'-0" 1. 4MM PE CORE ALPOLIC METAL PANEL (4CASM-BJ CLIP SYSTEM). SEE <br />i LIGHT FIXTURE MOUNTED ON INTEGRAL GUTTER SYSTEM FOR ELEVATIONS <br />TIO S FOR COLOR. PROVIDE MFG. SHOP DRAWINGS TO ARCHITECT <br />TRELLIS FRAMING, SEE _ _ _ <br />ELECTRICAL DRAWINGS CANOPY INSTALLED PER 2. OVER WALL ASSEMBLY 1A <br />MEMBRANE WALL FLASHING MFR. SHOP DRAWINGS <br />/STAINLESS STEEL DRIP EDGE FULL WALL HEIGHT ELEMENTS: <br />STEEL BEAM WITH w/ 1 /4" PLATE PROVIDE SLEEVES ON ALL FASTENERS 2• 8" CONCRETE BLOCK WITH INTEGRAL WATER REPELLENT (W.R. GRACE <br />(SEE STRUCTURAL DRAWINGS) OF CANOPY CONNECTIONS TO PROVIDE DRY -BLOCK OR EQUAL), SMOOTH FACED FINISH. MORTAR SHALL CONTAIN <br />CONSISTENT AND UNIFORM ATTACHMENT AN INTEGRAL WATER REPELLENT ADMIXTURE. COLOR TO BE STANDARD <br />3 DETAIL- CANOPY 0 WINDOW HEAD THROUGH BUILDING EXTERIOR WALL GRAY. PROVIDE NON -CORROSIVE METAL HORIZONTAL MASONRY <br />REINFORCING -SEE STRUCTURAL FOR VERTICAL SPACING. PROVIDE WEEP <br />5.0 1 1 /2" = 1 '-0'. FINISH. VENTS 32" O.C. AT ALL FLASHING LOCATIONS. WEEP VENTS SHALL BE <br />3/8"x 3 1 /2"H x3 1 /2" W. BASE OF WALL THROUGH -WALL FLASHING <br />TO BE EPDM OVER A STAINLESS STEEL DRIP EDGE TO EXTEND BEYOND <br />EXTERNAL FACE OF WALL ASSEMBLY. EPDM FLASHING SHALL RUN 16" <br />2 MIN. VERTICALLY UP ON INTERIOR FACE OF BLOCK. APPLY A CLEAR <br />PENETRATING WATER REPELLENT SURFACE TREATMENT CONTAINING <br />SILOXANE ON EXTERIOR FACE OF ALL CMU (SEE SPECS). SEE STRUCT. <br />T/PARAPET BLOCKING DWGS FOR LOCATION OF CMU w/ GROUTED CELLS AND BOND BEAM <br />ELEV. +18'-9 1/2"V LOCATIONS. POUR GRANULAR INSULATION INTO ALL UNGROUTED CMU <br />T BATTEN CAVITIES. <br />- - ELEMENTS BELOW THE ROOF DECK ONLY: <br />I ELEV. +18'-3" <br />I 3. 1 1 /2" RIGID INSULATION, R-7.5 VALUE <br />I 4. 3-5/8" 20 GAUGE METAL STUD FRAMING 0 16" O.C. <br />- SEE STRUCTURAL DRAWINGS FOR ANCHORAGE DETAILS <br />5. UNFACED GLASS FIBER INSULATION (R VALUE = 13). <br />6. 1 /2" CEMENT BOARD SUBSTRATE FOR ALL TILE LOCATIONS. (TYP.) <br />NON TILE LOCATIONS: 1 /2" GYPSUM BOARD TO EXTEND TO DECK <br />ABOVE. UNLESS NOTED OTHERWISE. <br />ALL GYP BOARD MUST SCORE 10 PER ASTM D3273, REFERENCE <br />CURRENT PROJECT MANUAL. <br />McDONALD'S ARCH SIGN BY 7. SEE A1.0 & ROOM FINISH SCHEDULE FOR ADDITIONAL SUBSTRATE <br />OTHERS & UNDER SEPARATE INFORMATION. <br />z <br />0 <br />a <br />tr <br />v <br />V) <br />w <br />0 <br />Date: 20�3_._08.11 <br />�y .•13:44V4"00' :A. <br />THIS DOCUMENT HAS <br />BEEN DIGITALLY SIGNED <br />AND SEALED. PRINTED <br />COPIES OF THE <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND <br />SEALED. THE SIGNATURE <br />MUST BE VERIFIED ON <br />ANY ELECTRONIC COPIES <br />OF THE DOCUMENT <br />08.11.2023 <br />PERMIT (COORDINATE EXTERIOR WINDOW ASSEMBLY DATE <br />STRUCTURAL AND ELECTRICAL (STOREFRONT & ENTRANCE SYSTEM <br />ROOFING ASSEMBLY - REQUIREMENTS) GLAZING REQ'S: SEE TITLE SHEET <br />(SEE SHEET A1.3) 1. EXTRA DARK BRONZE ANODIZED ALUMINUM FRAME, THERMALLY BROKEN <br />WITH HEAD RECEIVER CHANNEL. 1�- <br />2. 1" TEMPERED INSULATED IMPACT GLAZING <br />3. PROVIDE FLASHING AT HEAD & SILL - CONTINUOUS SEALANT. <br />4. PROVIDE METAL CAP 0 EXTERIOR BRICK SILL o10 <br />5. 1 /2" CORIAN SILL AT INTERIOR Q N c <br />ROOF JOISTS ' <br />(SEE STRUCTURAL <br />DRAWINGS) <br />1 /2" GYP. BOARD TO <br />UNDERSIDE OF JOIST <br />BEARING <br />EXTERIOR WALL ASSEMBLY 1 D <br />(SEE ASSEMBLY NOTES) <br />FREEZER/COOLER <br />PANELS ARE <br />CONSTRUCTED OF 4" <br />RIGID URETHANE <br />INSULATION (TO COMPLY <br />WITH ALL LOCAL CODES) <br />ENCLOSED IN MIN. 26 <br />GA. STEEL. <br />SEE FINISH SCHEDULE <br />FOR FLOORING <br />INFORMATION (SEE <br />STRUCTURAL DRAWINGS <br />FOR FREEZER SLAB <br />DETAILS) <br />(2) LAYERS R-10 RIGID <br />25 PSI XPS INSULATION I <br />w/STAGGERED SEAMS I R-10 RIGID XPS <br />INSULATION TOP OF SLAB <br />- - - - - - f-- ELEV. t0'-0" <br />o a <br />T FREEZER SLAB <br />ELEV. -0'-9 1 /4., <br />�' �- TYPICAL FOUNDATION AND <br />7 WALL SECTION - FREEZER COOLER CONCRETE SLAB (SEE <br />6 <br />STRUCTURE DRAWINGS) <br />5.0 3/4" = 1'-0" <br />w cn o <br />Ill - <br />CANOPY SYSTEM W f FASCIA <br />- z <br />CANOPY INFORMATION SHOWN IN CONSTRUCTION DOCUMENTS IS FOR DESIGN <br />ro <br />�' �, v 0 <br />INTENT ONLY APPROVED MANUFACTURERS SHALL PROVIDE A COMPLETE AND <br />COD COMPLIANT FINAL DESIGN. REFER TO ELEVATIONS FOR COLOR OF <br />ELEMENTS <br />� <br />wco <br />w � c~o- <br />1. CANOPY STRUCTURE OUTRIGGERS: CONT. 2" x 8" PAINTED ALUM. TUBE. <br />�„ <br />L <br />PROVIDE CLOSURE PIECE WHERE TUBE ENDS ARE EXPOSED. <br />a <br />¢ 3 z <br />2. FASCIA: CONT. 12"H PAINTED ALUM. w/ LED DOWN -LIGHT FIXTURE OVER <br />w <br />i uh O <br />CANOPY STRUCTURE. <br />of <br />a <br />n a a <br />3, TIEBACKS: PAINTED ALUM. THREADED RODS BY MFR. LOCATIONS AS <br />INDICATED ON ROOF PLAN. FINAL LOCATIONS AND QUANTITY SHALL BE AS <br />INDICATED ON CANOPY INSTALLATION DRAWINGS. <br />J <br />v ° <br />4. WHERE INDICATED ON ROOF PLAN, PROVIDE PAINTED ALUM. PANEL INFILL <br />a <br />TO MATCH OUTRIGGERS. PANEL TO PROVIDE POSITIVE SLOPE FOR DRAINAGE. <br />m o o 2 ° .o <br />5. SYSTEM SHALL ALLOW FOR MOVEMENT AT EXPANSION JOINTS AND FOR <br />ZD <br />a 0-aai 00� > j <br />MOVEMENT OF EXTERIOR WALL SYSTEM ON WHICH THE CANOPY IS <br />N <br />U o n ° <br />MOUNTED. <br />a <br />° v � �; ° o <br />6. STRUCTURAL ATTACHMENTS & LOAD CALCULATIONS SHALL BE FURNISHED BY <br />o <br />J o 0 3 D' 'o . <br />CANOPY SYSTEM DESIGNER OF RECORD. SUPPLIER'S DESIGNER OF <br />0 'n <br />RECORD SHALL DESIGN PER PREVAILING CODES. <br />u <br />^ U C N s- >n U <br />7. CANOPY SYSTEM SHALL BE SELECTED FROM ONE OF THE SUPPLIERS <br />LISTED BELOW. <br />8. MANUFACTURER SHALL PROVIDE INSTALLER WITH INSTALLATION INSTRUCTIONS. <br />o <br />c4 <br />r /� 4= --. <br />U) 0 °c °0 3 0 c <br />MANUFACTURER SHALL DESIGN CANOPY IN ACCORDANCE WITH THE WALL <br />w 0 0 o o ° co <br />SYSTEM AND BLOCKING AS INDICATED IN THE CONSTRUCTION DOCUMENTS. <br />L L ° ° <br />+-. VI - U N 2 ° <br />9• INSTALLER SHALL NOTIFY CANOPY DESIGNER OF RECORD, McDONALD' S ACM, <br />(n 2 ° o E <br />G.C. AND ARCHITECT OF ANY DEFICIENCIES THAT WOULD NOT ALLOW FOR <br />BE <br />- ° c ° _ ° v ° <br />° °o of-. <br />°' <br />THE PROPER INSTALLATION OF THE TRELLIS. CANOPY SHALL NOT <br />INSTALLED UNTIL DEFICIENCIES HAVE BEEN CORRECTED IN ACCORDANCE <br />_� <br />WITH THE CONSTRUCTION DOCUMENTS AND THE CANOPY MANUFACTURER'S <br />d? L <br />INSTALLATION INSTRUCTIONS. <br />c: °= U + �J <br />CANOPY SYSTEM BY: <br />0 N w o w <br />GREENHECK (715) 355-3942 ALL-LITE (817) 509-2300 <br />° <br />www.greenheck.com www.alllite.com <br />a o o <br />° U <br />AWNEX (770) 704-7140 <br />Q ° <br />www.ownexinc.com <br />, <br />C �' <br />G i <br />WHITE FASCIA & LED LIGHTING BY: <br />ER <br />o <br />EVERBRITE (888) 857-4078 PERSONA (800) 843-9888 <br />0 <br />® � ° <br />www.everbrite.com www.personasigns.com <br />4)0 N o w° <br />FOUNDATION AND PERIMETER INSULATION <br />a <br />a. <br />1. SEE STRUCTURAL DRAWINGS FOR FOUNDATION AND SLAB DETAILS <br />w <br />� w <br />� N <br />in <br />m <br />0 <br />~ N <br />Q <br />L a J <br />w <br />O <br />N <br />m <br />m <br />I <br />Z <br />J <br />c3 <br />m <br />z W <br />p <br />( m <br />(ifW <br />Q <br />m <br />N <br />Ix zLn <br />IF, <br />c!)�0 <br />Q-Z' <br />N �_ <br />z <br />p 00 <br />3 v�i <br />ifa, <br />N <br />o <br />U) 0 <br />NSN#: <br />40871 <br />0 <br />z <br />5. <br />A 0 <br />w <br />cn <br />WALL SECTIONS <br />
The URL can be used to link to this page
Your browser does not support the video tag.