Laserfiche WebLink
4'-6 3/4" 21'-9" W-0" 5'-1 1/4" <br />C1 LE C1 n <br />LE C1 c, LEGEND mBASE RAIL <br />3'-0") (P(3'-O") L2 (3'-0") (3'-0'� <br />S L.P. LOW POINT ASRREQUSRED <br />LE HVAC UNIT <br />T ROOF ASSEMBLY <br />� a � o_ �— o_ LE H.P. HIGH POINT SEE SHEET A1.3 <br />L1 --- - -- --- - -_ -- ¢ ¢ ¢ ¢ ¢ L1 ROOF CURB ( ) <br />XX, <br />H.P. DIRECTION OF DRAINAGE ROOF DECKH.p.\ __��- INSULATION 0 <br />\y <br />L.P. © ® MF MF H.P. <br />AP TRELLIS SYSTEM WITH FRAMING FOR a <br />ROOF DRAIN w/ k/ y ALUMINUM INFILL PANELS. < <br />OVERFLOW DRAIN i Cl C2 OPENING (SEE v <br />SLOPE TO EDGE 01 /4 PER FT. STRUCTURAL <br />TAPERED INSULATION (TY '--�`� DRAWINGS o <br />S i MAINTAIN POSTIVE DRAIN E _) <br />1 1 RESTROOM _` KEY NOTES -------------- ----- <br />7 ll0EXHAUST FAN I I ALUMINUM CANOPY SYSTEM W/ FASCIA <br />c1 <br />❑ (COLOR: SEE ELEVATIONS) <br />ALUMINUM CANOPY SYSTEM (COLOR: <br />I C 1 C2 <br />VENT STACK, ( ( co � ❑ SEE ELEVATIONS) <br />SEE DETAIL 2 A6.0 ( ( 3 -0 BAR JOIST <br />- O / i i 3 M( ) METAL ROOF DECK w <br />00%I ROOF WALKWAY PAD, TYP. HOSE IB 1 - ACCENT LIGHTING - SEE Q <br />w \ SEE M ING TYP 0w tz qp LE Ll %ELEVATIONS & ELECTRICAL <br />-) <br />a i ROOF TOP _ _ _ L—L - - - _ _ - <br />0 0° HVAC UNIT - - - ROOF TO>p o 00 L3 L1 D LIGHT: <br />LED DOWN ONLY <br />J I <br />HVAC UNIT i U) po �'P• <br />H.P. (RIDGE) N M L2 = INTEGRAL CANOPY FIXTURE � <br />i H.P. (RIDGE) L3 = UP ONLY FLOOD FIXTURE 3 HVAC UNIT ROOF CURB DETAIL <br />8 _ _ _ _ _ _ <br />- - - I 4FRYER <br />iwa MF METAL FASCIA 1 1 2 1 GRILL i i o A Cl-COLOR: �Q'.K R S <br />i EXHAUST - - - - - - N 00 AP Cl = SEE ELEVATIONS FOR COLOR y: rti•;'� <br />_ _ _ _ _ _ _ _ FAN EXHAUST FAN I I �j C2 = SEE ELEVATIONS FOR COLOR <br />i ,� � DIRECTION <br />T I 4 McDONALD'S SIGNAGE BY OTHERS OF EXHAUST • ;Date: ' � s '�b�3-b8.11: <br />I •br � I i � 1. <br />w i ROOF TOP i i AP El SEPARATE PERMIT (SEE •• <br />o` I IL HVAC UNIT TYP I I ---- --- _ . _ _ ELEVATIONS) ��'�•.••.. ..••'••,��V <br />J ' <br />-} .. <br />0o I�- ��. _�I � '� i i I s�FRED ARG�� <br />1­1SEE EXHAUST <br />M 2'-0"W ADDITIONAL ROOF �� - _ S ROOFING NOTES FAN DETAILS <br />1 CRICKET AT ALL <br />6.0 - MEMBRANE AROUND ON MECHANICAL <br />CURBS &EQUIPMENT <br />SUPPORTS TYP. - - COOKING EXHAUST FANS DRAWINGS FOR <br />1. SINGLE -PLY ROOFING SYSTEM WITH <br />BASE FLASHING SHEET EXTENDING UP ADDITIONAL THIS DOCUMENT HAS <br />4' m (3'-0") PARAPET AND TERMINATED UNDER I INFORMATION. BEEN DIGITALLY SIGNED <br />--`__ 7 co COPING HOT WELDED TO SEALING STRIP AND SEALED. PRINTED <br />A3.1 TMp MF MF SECURED TO WOOD BLOCKING COPIES DOCUMENT THE <br />2. INSTALLATION OF ROOFING SHALL BE IN SIDERARE NOT <br />H p L-P• p �1_''- a L.P. H.P. ACCORDANCE WITH MANUFACTURER'S CONSIDERED SIGNED AND <br />H.P. Cl C1 C2 SEALED. THE SIGNATURE <br />SPECIFICATIONS AND PER DETAIL 2 OF <br />THIS SHEET. 1 MUST BE VERIFIED ON <br />- - 3. PROVIDE PREFABRICATED METAL CURBS. 1/2" CEMENT ANY ELECTRONIC COPIES <br />a a COORDINATE SIZE, LOCATION AND BOARD OR OF THE DOCUMENT/ 08.11.2023 <br />LE C2 ¢ G2 ¢ C2 ¢ LE INSTALLATION REQUIREMENTS W/ M E, 5 8 TYPE X <br />(4'-O") % (4'-0') � S (4'-0") P & S SHEETS. PROVIDE SHIMS TO GYP BOARD <br />L1 DATE <br />6" 6" 6" 6" 6" - - 6" 1 LEVEL CURB AREAS WHERE ROOF DECK <br />ULj <br />IS PITCHED. 1 <br />5'-8" 5'-8"L 5'-8" <br />4. FOR EXACT LOCATION OF EXHAUST _ <br />6'-8" 6'-8" 6'-8" FANS, HVAC UNITS, AND ROOF HATCH. v <br />- _-_- - <br />- - REFER TO STRUCTURAL DRAWINGS. IL <br />5. CRICKETS MUST BE INSTALLED AT ALL ~00 <br />�o <br />ROOF CURBS & EQUIPMENT PLATFORMS 4 DETAIL ® EXHAUST FAN Q uj <br />N a <br />en 0 <br />BY GC. lyLL H N <br />1 ROOF PLAN ter' <br />m® T V W M <br />A1.3 SCALE: 3/ 16» = 1 f -0ff ®� <br />NORTH w Ln <br />Z W W <br />w 2 (A O <br />a. 0 � a <br />ROOFING SYSTEM PVC VENT PIPE DIAMETER TAPERED INSULATION � 1,-0 o _ ° <br />VARIES SEE PLUMBING DWGS TO FORM ROOF DRAIN 1'-2" PARAPET WALL � o o c O.�' ° o <br />COPING PER 1. MANUFACTURERS AND PRODUCTS: SURE -SEAL WATER CUT-OFF MASTIC SUMP AREA ` ` am � o N > <br />to �,J <br />SPECIFICATION COPING PER SPECIFICATION A. DURO-LAST PVC ROOFING SYSTEM z 0-'- a, -0° - a o <br />ROOF GROMMETTED SCREWS 18"O.C. B. JM-PVC. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) Q STAINLESS STEEL CLAMP RING OVERFLOW TERMINATION 2 7 o �, o <br />MEMBRANE VIEW COPING ROOF MEMBRANE FULLY FOR MOST UP-TO-DATE INFORMATION. p --�'r� OVERFLOW DRAIN (SEE PLUMBING DRAWINGS) 0 o o N a <br />Ui <br />FULLY ADHERED NO SUBSTITUTIONS ALLOWED 0 _ _ _ - . _ a r , <br />ADHERED Z DRAIN w/ STRAINER, N _, -n o -- L <br />SURE -WELD PRE -MOLDED PIPE FLASHING r<, t? E •- - o <br />m - INSTALL PER MFR'S RECOMMENDATIONS � - ° :L o <br />::.. 2. SPECIFIED ROOFING SYSTEMS (AS SHOWN): s SEE DETAIL 8/A1.3 �� - - - - - (n o � - .3 u o W <br />CMU WALL, HEAT -WELDABLE SINGLE -PLY 50 MIL PVC ROOFING SYSTEM, INSTALLED J O � L �' <br />BRICK WALL, OVER RIGID INSULATION ON WOOD ROOF DECK HAVING A SLOPE OFcn <br />o_ HOT AIR WELDS AT SEAMS cD s s <br />FASTENERS ' x�`' =' SMOOTH CONCRETE WALL, 3/8"/FT. MATERIALS SHALL BE AS FOLLOWS: w (n �_ <br />��`'::::::: w COMBINATION MAIN ROOF iv �, o - �, E c <br />12 O.C. �` OR ANY "APPROVED" N MIN. <br />:+�?:`:::::::::::::: :::::: A. SINGLE -PLY ROOFING SYSTEM AS MANUFACTURED BY MANUFACTURER AND OVERFLOW DRAIN o c ° t <br />,� A SMOOTH SURFACE SUBSTRATE LISTED ABOVE TO COMPLY WITH ASTM E 108 OR UL 790, ASTM SEE PLUMBING ' $ PIPING c 0 <br />CLEAT :..• .:.:.::::..:............................... 5' ( OUTLINE OF STORM P c o 0 :::,>�............::::::::::. :::::::::::::::.:: i.e., PLYWOOD, 1.3 J _ o E, <br />- - UPLIFT. DRAWINGS <br />0 <br />D 6878 AND FMG I 90 FOR WIND U <br />FASTENED PER : ��`'::::::::::::::::::.:.:::::::::.:::::::::.:.:::::::::: GLASS FACED GYPSUM __ (SEE PLUMBING DRAWINGS) ° a � a " 0 L <br />"SMACNA B. FASTENERS: METAL FASTENERS AND PLATES AS PER MANUFACTURER. _ <br />o 0 <br />o - c <br />C. ACCESSORIES: PRE -FABRICATED CURBS, FLASHING, CORNERS, <br />I I 0 N-- = °w �t <br />PIPE FLASHING T FLASHING ETC. AS PER - c n - c <br />TERMINATION BARS, VENT FLA 3 MEMBRANE FASTENERS AND PLATES <br />....................................................... <br />TAPERED INSULATION <br />SPACED EQUALLY AROUND PIPE 0 c <br />" MANUFACTURER. _ <br />1-1 /2 MIN. HEAT WELD SEE ROOF PLAN I 1 0° o to m o <br />D. PLEASE SEE SINGLE -PLY FLASHING SPECIFICATIONS FOR A FULL 5 <br />U 0 o N ° o <br />2x NAILER 'a. ° - o -c <br />�.. , ROOF MEMBRANE EDGE DESCRIPTION OF INSTALLATION INSTRUCTIONS AND REQUIREMENTS � ° <br />FASTENED AS :�: �� •• SEE ROOF PLAN FOR FLAT ROOF LINE OF KICKER, SEE z �,CL <br />+ �::. I ( SEALANT IF FIELD CUT) WHICH ARE CONSIDERED A PART OF THIS DETAIL. <br />SPECIFIED '` •4•�••••• •••• c - o L <br />t { D BE DESIGNED AND i'�-- _ <br />• 4• • CONSTRUTION PLAN w ° o� o o o <br />ROOF MEMBRANE E. ANY CARPENTRY OR METAL WORK SHOUL o v T <br />............................. <br />.............................. <br />............................. <br />.............................. <br />......•...... """""" {- •-••,�•� ) CONSTRUCTED IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS 2x FRAMING AT OPENING W N °1 ° <br />ROOF :.:�\1'..:' ' (MECHANICALLY FASTENED AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS SHOULD BE l`�-�J a a, o ° W'i <br />MEMBRANE 44 , ,r� :: a N a N , <br />4�•... xr�(� REVIEWED AND APPROVED BY A LICENSED DESIGN PROFESSIONAL. PIPE CLAMP 5 TYPICAL VENT PENETRATION 6 ROOF DRAIN DETAIL a's ° <br />BONDING x...:..;�,.:.::.:. <br />i x. . <br />ADHESIVE ::.:..,� r}{��`` WITFiINCTHE AMANUFACTUREROS GUARANTEE. <br />ONS TO BE INCLUDED A1.3 1 1 =1 -Q .3 3 4 = 0 <br />w <br />MIN. 1/2! F. ROOF MEMBRANE EDGE SEALANT IS REQUIRED ON ALL CUT OR <br />ocD WN <br />04 <br />MEMBRANE �� NON -ENCAPSULATED EDGES OF REINFORCED MEMBRANE. THIS cn ,,, o o Cn o <br />' INCLUDES FACTORY CUT MEMBRANE AIL "A" 3 m M W M `� 006 <br />ABOVE TERM r�' .. • .... NOTE: DETAIL N <br />t5 .. go_ -o ��! _ <br />BAR TAPER INSULATION INSTALL ROOF DRAIN THIS DETAIL ILLUSTRATES THE METHOD TO o <br />C1, <br />" ' ' ' ' 3. WALKWAYS: TOWARD DRAIN SUMP AREA PER MFR. SPECS ELIMINATING PITCH POCKETS AND THE METHOD OF SNAP CAP TO o = <br />2, e::...................................................... " <br />GROUPING PIPING THAT MUST PENETRATE THE ROOF. N <br />- • • AY ROLL HOT AIR WELDED TO MEMBRANE. LOCK <br />A. 3O WIDE WALKWAY N <br />B. PROVIDE WALKWAY FROM ROOF LADDER EXIT TO ALL ROOF TOP <br />_ EXTEND ROOF N <br />EQUIPMENT AS PER ROOF PLAN ABOVE. DRAIN w STRAINER PORTALS PLUS KORAD LAMINATED STAINLESS CLAMP BY m <br />:..::..::::::::::•... MEMBRANE UNDER PORTAL COVER PORTALS PLUS m <br />-- . - - . - . -- C. INSTALL WALKWAY ACCORDING TO WALKWAY PAD MFR S WRITTEN ABS PIPE <br />INSTRUCTION. - - -- CLAMPING COLLAR _ <br />R PER MFR. GASKETED FASTENERS MIN. EPDM RUBBER PIPE <br />:. 4. RIGID INSULATION: TWO PER SIDE PORTAL CAP Z_ <br />POLYURETHANE PROVIDE REQUIRED LAYERS OF POLYISOCYANURATE INSULATION w/ 1 /2" <br />SEALANT "DENSDECK" COVER BOARD TO MEET A MINIMUM CONTINUOUS R-25 FASTENERS APPROX. 8" O.C. ROOF ASSEMBLY J <br />VALUE - THICKNESS AS REQUIRED. PROVIDE POSITIVE SLOPE TO ALL i (SEE SHEET A1.3) Q <br />TERMBAR WITH m 3 c, <br />ROOF DRAINS. SEE ROOF PLAN. PROVIDE TOP LAYER PROTECTION PORTALS PLUS PIPE PORTAL z w <br />FASTENERS ® 16" O.C. - c0 J <br />MATERIAL AS PER MANUFACTURERS RECOMMENDATIONS. BOTTOM LAYER � CURB STYLE RC-4A p z � on <br />PERMITER FASTENING - OF INSULATION TO HAVE INTEGRAL THERMAL BARRIER OR APPROVED cn (a� <br />/ - � V J <br />MECHANICAL FASTENERS ROOFING MANUFACTURERS THERMAL UNDERLAYMENT SHEET. ASSEMBLY FASTEN PER MANUFACTURER'S Q 444m»J o q <br />SHALL COMPLY WITH UL 1256 OR FMG 4450 AND ASTM C 1289, TYPE w <br />�. � O Z W � <br />12 O.C. I OR II.--Lo <br />----------------- __ _ REQUIREMENTS Q J m NLn <br />DENSDECK 1/2" PRIME - - -- - -- - -- - ---- z <br />------- <br />ROOF- HOARD 5. TAPERED INSULATION: _________________ ROOF DECK - - o <br />POLYISO BOARD INSULATION PROVIDE TAPERED INSULATION AS REQUIRED FOR POSITIVE DRAINAGE TO -` - ` -' `- - - - --- - _ ______________ LOOSE BATT INSULATION cam► 0 <br />ROOF DRAINS AS INDICATED PER ROOF PLAN ABOVE. 1/4" PER FOOT �� (R-30 MIN.) N r 0 � W N <br />ROOF DECK - THIS DETAIL IS ALSO SUITABLE MIN. REQUIRED. PORTALS PLUS IS A SUPPLIER OF PREFABRICATED ROOF ` 0 w cn �' rn <br />TERMINATION OF FLEECE BACKED 6. EXHAUST FANS: ACCESSORIES AND DOES NOT ASSUME RESPONSIBILITY ��— SUPPORT PIPES FROM F N r vn o <br />FOR ERRORS IN DESIGN, ENGINEERING STRUCTURE <br />MEMBRANES. NON FLEECE BACK INSULATE BELOW ROOF---- NSN#: 40871 <br />PROVIDE ADDITIONAL LAYER OF ROOF MEMBRANE AROUND EXHAUST FANS <br />MEMBRANE IS REQUIRED FOR WALL DECK AT ROOF DRAIN OR INSTALLATION. THE ROOFING SYSTEM MFR'S <br />2 ROOFING SYSTEM FLASHINGS. AS INDICATED PER ROOF PLAN ABOVE. (R-30 MIN. INSULATION 7 SECTION ® ROOF DRAIN INSTALLATION REQUIREMENTS MAY SUPERSEDE THESE 8 PIPE PORTAL DETAIL Z <br />WITH FIRE RETARDANT DETAILS FOR WARRANTED ROOF SYSTEMS. SEE ff f » w <br />A1.3 N.T.S. VAPOR BARRIER) A1.3 SCALE: 3" = 1'—O" MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION A1.3 SCALE: 3 = 1 -O ROOF PLAN <br />