Laserfiche WebLink
I <br />ELECTRICAL SYMBOLS LEGEND <br />GENERAL <br />NOTES <br />(SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) <br />SYMBOL <br />DESCRIPTION <br />FO <br />LIGHT FIXTURE <br />1. <br />FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND LABOR, FOR A <br />14. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS AND <br />/ O <br />(WALL MOUNTED/CEILING MOUNTED) <br />COMPLETE INSTALLATION IN ALL RESPECTS, READY FOR INTENDED USE <br />BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY LOCAL <br />AND IN STRICT ACCORDANCE WITH NEC, NESC, STATE, AND LOCAL <br />CODES. <br />E-� <br />LIGHT FIXTURE <br />CODES, AND MANUFACTURER'S RECOMMENDATIONS. PAY ALL <br />NECESSARY FEES AND PERMITS. <br />5. EXISTING ELECTRICAL AND ALARM: <br />LIGHT FIXTURE <br />EMERGENCY LIGHT <br />A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE <br />A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS <br />LIGHT FIXTURE <br />ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS. <br />EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT, <br />DEVICES, OR LIGHTING TO REMAIN, BUT NOT SHOWN ON DRAWINGS, <br />NIGHT LIGHT <br />B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. <br />PROVIDE LABOR AND MATERIALS TO REWORK CIRCUITRY, AS <br />0 <br />ENCLOSED COOLER/FREEZER LIGHT <br />REQUIRED, TO MAINTAIN EXISTING OPERATION. <br />C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE <br />OPERATIONS. COORDINATE ALL DISRUPTIONS WITH WALMART <br />B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT EXISTING <br />le le le <br />TRACK LIGHTING <br />CONSTRUCTION MANAGER AND STORE MANAGER. <br />UNDERGROUND SERVICES (ELECTRICAL, TELEPHONE, PARKING LOT <br />LIGHTING CIRCUITRY, ETC.) PROVIDE ALL MATERIALS AND LABOR AS <br />/® <br />EXIT FIXTURE <br />D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESS <br />REQUIRED TO REROUTE, SLEEVE, OR OTHERWISE REWORK THESE <br />(WALL MOUNTED/CEILING MOUNTED) <br />BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED <br />SERVICES TO MAINTAIN THEIR EXISTING OPERATION. <br />BOXES OR BOX EXTENDERS WHERE REQUIRED. <br />EMERGENCY FIXTURE <br />C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES <br />E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED PANELBOARDS <br />DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM AND <br />SWITCH, SINGLE POLE <br />HAVE CIRCUIT BREAKER KNOCKOUTS PROPERLY COVERED AND <br />SECURITY CABLES FROM ACCIDENTAL DAMAGE SO THAT SYSTEMS <br />THAT ALL TRIM IS IN GOOD CONDITION, ALLOWING NO ACCESS TO <br />REMAIN OPERATIONAL AT ALL TIMES. <br />LIVE PARTS. <br />$3 <br />SWITCH, 3-WAY <br />D. DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE <br />2. <br />PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: <br />NOTED. <br />$4 <br />SWITCH, 4-WAY <br />A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE STOPPING. <br />B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. <br />16. EXISTING ELECTRICAL DEMOLITION: <br />C. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM SEALANT. <br />$K <br />SWITCH, KEYED <br />D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR SEALING <br />A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL <br />REQUIREMENTS AT ALL EXTERIOR MOUNTED DEVICES, FIXTURES, <br />EQUIPMENT CONDUIT, AND CONDUCTORS AS INDICATED ON THE <br />$D <br />SWITCH, DIMMER <br />ENCLOSURES, AND RACEWAY PENETRATIONS. <br />DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. REMOVE ALL <br />PANELBOARDS, DISCONNECT SWITCHES, BOXES, RELAYS, TIME <br />3. <br />PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR (SIZE <br />SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL NOT BE REUSED. <br />$VS <br />SWITCH, VARIBLE SPEED <br />PER NEC) IN PVC TYPE CONDUIT, POWER CIRCUITS, ISOLATED GROUND <br />CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT SHALL BE SIZED PER <br />B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, <br />$M <br />SWITCH, MANUAL MOTOR <br />NEC BASED ON THWN 600 VOLT COPPER SINGLE CONDUCTORS, PLUS <br />CONDUCTORS AND RELATED DEVICES SERVING SALES AREA <br />THE EQUIPMENT GROUNDING CONDUCTOR. <br />GONDOLAS BEING RELOCATED OR REMOVED. EXISTING CONDUIT <br />4. <br />WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM FINISHED <br />AND CONDUCTORS MAY BE REUSED FOR NEW POWER DROPS <br />$OS <br />SWITCH, OCCUPANCY SENSOR <br />FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED OTHERWISE ON <br />WHERE SIZE, RATING, AND CONDITION MEET REQUIREMENTS <br />PLANS. COORDINATE THE STANDARD MOUNTING HEIGHTS WITH <br />INDICATED ON PLANS AND ALL U.L. RATINGS. REMOVE ALL UNUSED <br />$$OS <br />SWITCH, BI-LEVEL OCCUPANCY SENSOR <br />MASONRY: <br />CONDUIT AND CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER <br />"SPARE". <br />FEASIBLE AND RELABEL DEMOLISHED CIRCUITS AS <br />ES / ® <br />CEILING OCCUPANCY SENSOR AND ASSOCIATED RELAY <br />A. SWITCHES +42" <br />B. RECEPTACLES +20,r <br />PROVIDE HANDLE DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN <br />THE "OFF" POSITION. <br />C. VOICE/DATA +20" <br />RECEPTACLE, DUPLEX <br />5. <br />WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN <br />C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING SPACES AND <br />CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS. <br />OTHER NON-PUBLIC AREAS (I.E., THROUGH STOCKROOM AREA): <br />RECEPTACLE, DUPLEX, <br />6. <br />CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE <br />CUT WIRING LOOSE AND REMOVE FROM RACEWAY(S), LEAVING <br />MOUNTED HORIZONTALLY <br />PANELBOARD IDENTIFICATION SCHEDULES FOR PANELBOARDS <br />RACEWAY(S) IN PLACE. CONDUIT TO BE ABANDONED IN WALLS OR <br />AFFECTED BY REMODEL. <br />FLOORS SHALL BE REMOVED BACK TO FINISHED SURFACE AND <br />RECEPTACLE, DOUBLE DUPLEX <br />7. <br />NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN EXISTING <br />CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT. <br />PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE TYPE <br />RECEPTACLE, DUPLEX ISOLATED GROUND <br />AND AIC RATING OF EXISTING OVERCURRENT PROTECTIVE DEVICES. <br />D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE <br />N <br />ABANDONED OR REMOVED SHALL REMAIN IN RESPECTIVE <br />8. <br />BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG UNLESS <br />PANELBOARD FOR FUTURE USE, UNLESS NOTED OTHERWISE ON <br />RECEPTACLE, DOUBLE DUPLEX, <br />NOTED OTHERWISE IN SCHEDULES. WHERE 20A BRANCH CIRCUITS <br />DRAWINGS. PROVIDE HANDLE DEVICE TO LOCK "SPARE" CIRCUIT <br />ISOLATED GROUND <br />HAVE #8 AND LARGER WIRE SPECIFIED, #10 AWG WIRE SHALL BE USED <br />BREAKER IN THE "OFF" POSITION. <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />FOR THE FINAL CONNECTION (15-FT MAXIMUM). <br />L5-15R, UNO <br />9. <br />WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND DERATE <br />E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />CURRENT CARRYING CONDUCTORS PER NEC. <br />SELECTIVE SITE DEMOLITION SPECIFICATION FOR DISPOSAL OF <br />LIGHT FIXTURE. <br />ISOLATED GROUND, L5-15R, LINO <br />10. <br />PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH <br />n <br />RECEPTACLE, DUPLEX TWIST LOCK, <br />CIRCUITS PER NEC REQUIREMENTS. <br />F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK <br />`�#' <br />L5-15R, LINO <br />SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR <br />RECEPTACLE, DUPLEX TWIST LOCK, <br />11. <br />SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE SHALL <br />CREATING DAMAGE OF ANY KIND IN THE FUTURE. <br />nn <br />BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE ONLY THE <br />`W <br />ISOLATED GROUND, L5-15R, UNO <br />TOP AND BOTTOM CHORDS FOR SUPPORTING THE ELECTRICAL <br />7. ETHERNET CABLE: <br />RECEPTACLE, SPECIAL <br />SYSTEM INSTALLATIONS. <br />A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON PLANS. <br />12. <br />DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE SURFACE <br />PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES AND/OR <br />RECEPTACLE, SIMPLEX <br />MOUNTED UNLESS NOTED OTHERWISE. REFER TO ARCHITECTURAL <br />ORDINANCES. <br />DOCUMENTS FOR CONDUIT INSTALLATION AND SEALING <br />RECEPTACLE, PLUG -MOLD <br />REQUIREMENTS. <br />B. ETHERNET CABLE IS FURNISHED BY OTHERS. <br />13. <br />ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM AND <br />C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POWER POLES. <br />O <br />JUNCTION BOX <br />BRANCH CIRCUITS NOTED BY LEGEND SHALL BE INSTALLED UNDER <br />(WALL MOUNTED/CEILING MOUNTED) <br />SLAB. ALL OTHER FEEDER AND BRANCH CIRCUITS SHALL BE <br />D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS <br />OA <br />JUNCTION BOX, ALARM SYSTEM <br />INSTALLED OVERHEAD. PROVIDE EXTERIOR COATED GRC BENDS ON <br />ALL CONDUIT RUNS THAT HAVE 45 DEGREE BENDS OR GREATER. REF <br />DIRECTED BY WALMART CONSTRUCTION MANAGER. <br />(WALL MOUNTED/CEILING MOUNTED) <br />SPECIFICATIONS. <br />ALARM JUNCTION BOX, <br />® <br />FOR REMOTE TEST/RESET <br />(WALL MOUNTED/CEILING MOUNTED) <br />EQUIPMENT CONNECTION POINT <br />0 <br />(PROVIDED WITH EQUIPMENT) <br />Eh <br />NON -FUSED DISCONNECT <br />01 <br />FUSED DISCONNECT <br />SNATCHED/ <br />TRAVELERS NEUTRAL <br />CIRCUIT, CONCEALED IN WALLS OR <br />CEILING, E INDICATES EXISTING <br />Ic HOTS <br />GROUND <br />WIRING <br />CIRCUIT, CONCEALED IN FLOOR SLAB, <br />_ <br />E INDICATES EXISTING WIRING <br />CIRCUIT, EXPOSED, <br />E INDICATES EXISTING WIRING <br />FLUSH MOUNTED PANELBOARD <br />- <br />SURFACE MOUNTED PANELBOARD <br />VOICE/DATA, <br />-/-d/-v <br />d = DATA ONLY, v = VOICE ONLY <br />0 <br />LOW VOLTAGE CABLE BOX FOR OTHER <br />m <br />VOICE/DATA, FLUSH FLOOR <br />MOTOR <br />7 <br />8 <br />2-1/2" UNISTRUT <br />STRAP FIRMLY <br />CLAMPED TO <br />CONDUIT <br />2-1/2" <br />PVC <br />CONDUIT <br />PHOT <br />1 /8" = 1'-O" <br />�O TELEPOWER POLE I I FURNISH AND INSTALL QUAD I ELECTRICAL CONTRACTOR TO DISCONNECT EXISTING POWER AND <br />RECEPTACLES IN WIRELESS AND DATA AS REQUIRED FOR REPLACEMENT OF GONDOLA BY GENERAL <br />�• PUSH BUTTON CHECKOUT KIOSK THAT DOES NOT CONTRACTOR. RECONNECT POWER AND DATA UPON PLACEMENT ON <br />3'-2" CONTAIN A POWERPOLE, TYP. NEW GONDOLA. COORDINATE WITH GENERAL CONTRACTOR. <br />In 1 <br />BUZZER <br />ENL <br />OS SMOKE DETECTOR PD2 _ <br />i 3 <br />OENERGY MANAGEMENT I 16.470 <br />S TEMPERATURE SENSOR a' 16.957 E1 <br />10'-8" 10'-4" 9'-8" 10'-0" 5'-7" 0 <br />10'-6" -* 17'-5" <br />OT THERMOSTAT (-- <br />ENG J I0 or <br />FTC TIME CLOCK PD2 87 <br />°I <br />ABBREVIATIONS 16.470 <br />a, b, c LOWER CASE LETTERS INDICATE HD HAND DRYER 16.957 I Ll o <br />sm <br />SWITCHING CONFIGURATION IG ISOLATED GROUND I O <br />AFC ABOVE FINISH COUNTER IRC INTER -REGISTER <br />AFF ABOVE FINISH FLOOR COMMUNICATION <br />AFG ABOVE FINISH GRADE ISP IN-STORE PROCESSOR 1 70 16.470 <br />C CONDUIT LCU LIGHTING CONTROL UNIT 1 1 57 66.957 1 <br />CCT CIRCUIT K KEY OPERATED 16.470 16.470 16.470 16.470 <br />CF CEILING/CIRCULATION FAN N NEUTRAL 16.957 16.957 16.957 16.957 <br />D DATA NTS NOT TO SCALE 16.470 <br />EC ELECTRICAL CONTRACTOR P WITH PILOT LIGHT 16.957 <br />EF EXHAUST FAN RH RADIANT HEATER ENG tPD2 tE <br />5 LE <br />IPD <br />PN <br />EP EXPLOSION PROOF RC REFRIGERATION �n E1 <br />NG <br />ETR EXISTING TO REMAIN CONTRACTOR J J PD2 <br />EWC ELECTRIC WATER COOLER SC SECURITY CAMERA o 2A SIMILAR,TYP 72A <br />FUT FUTURE SF SUPPLY FAN <br />GR GROUND TR TAMPER RESISTANT 1 15'-11" 1 ;-4" <br />GFEP GROUND FAULT EQUIPMENT TYP TYPICAL 0° <br />PROTECTION WH WATER HEATER <br />GFI GROUND FAULT CIRCUIT WP WEATHERPROOF PD2 PD2 ENT ENT ENT EN ED PD2 <br />INTERRUPTER WR WEATHER RESISTANT <br />GF GABLE FAN UH UNIT HEATER <br />UNO UNLESS I <br />OTHERWISENOTED 1 B11 B 1 g11 B o' 1. 1 BL1 B 1 BL1 B 1 BL1 B <br />0 <br />PROVIDE 3/8" FLEXIBLE METAL WHIPS FROM JUNCTION BOX AND <br />CONNECT AT TOP OF POWER POLE. CABLE WHIPS TO POWER POLE <br />SHALL BE INSTALLED IN A NEAT AND WORKMAN -LIKE MANNER. ROUTE <br />WHIPS TO TERMINATIONS ALONG UNISTRUT OR STRUCTURE AND <br />SUPPORT EVERY 12" TO 24". EXCESS CABLE SHALL BE KEPT TO A <br />MINIMUM AND TIGHTLY COILED AND ATTACHED TO UNISTRUT OR JOIST. <br />NO CONNECTION OF ANY KIND SHALL BE MADE TO JOIST <br />WEB MEMBERS, JOIST BRIDGING, OR ROOF DECK. MAINTAIN <br />MINIMUM 6" CLEARANCE FROM TOP OF POWER POLE TO <br />ROOF DECK. JUNCTION BOXES AND RACEWAYS SHALL NOT <br />BE MOUNTED WITHIN 1-1/2" OF DECK. <br />EXTEND POWER <br />POLE 12" MIN. WITHIN <br />PVC SLEEVE <br />EXTENDER ARM / <br />POWER POLE <br />FINISHED <br />FLOOR <br />PVC SLEEVE LENGTH 12" MIN. TO 36" <br />MAX. TO ACCOMMODATE VARIATIONS/ <br />IN STRUCTURE HEIGHT. <br />INSTALL CEILING FLANGE <br />PROVIDED WITH POLE FOR <br />STORES WITH LAY -IN <br />CEILING <br />ANCHOR POWER POLE TO FLOOR OR <br />GONDOLA WITH FOOT BRACKET PER <br />MANUFACTURER RECOMMENDATIONS <br />UNISTRUT <br />PROVIDE 1-1/4"\ <br />FENDER WASHER, <br />LOCK WASHER AN <br />NUT, TYP <br />PROVIDE UNISTRUT PER <br />SPECIFICATIONS. LENGTH AS <br />REQUIRED TO SPAN JOISTS. <br />SECURE TO BOTTOM CHORD <br />OF BAR JOIST. <br />POWER POWER POLE CONNECTION, <br />PHOTO <br />LAB <br />16.492 <br />=CTRCAL DEVICES, <br />CIRCUITRY ANC) O <br />PANEL BOAR___] <br />PROVIDE 1 /4" BOLT <br />AND 1-1/4" FENDER <br />WASHER TYP <br />PROVIDE <br />UNISTRUT P1026 <br />ANGLE FITTING OR <br />EQUAL <br />BOTTOM <br />CHORD OF <br />BAR JOIST <br />0&3&18 EP42 <br />8 <br />ROUTE POWER AND DATA/VOICE - <br />CONDUITS FROM THE STRUCTURE ABOVE <br />DOWN TO THE PHOTO LAB COUNTERS <br />THROUGH POWER POLE WHEN PHOTO LAB' <br />IS LOCATED ON THE SALES FLOOR. <br />BL1 A <br />BL1 A C16.470 <br />H 16.470 16.957 <br />LAB DEMO POWER PLAN <br />POWER DROP PL. <br />r <br />ALCOA <br />H <br />G.5 <br />0 <br />PHASER- <br />P AND SP <br />UNIT <br />WIDE FORMAT <br />PRINTER <br />PHOTO <br />LAB <br />HP\ <br />\ <br />BL1 A <br />DL PRINTER 16.470 <br />16.957 <br />- BL1 A <br />16.470 <br />16.957 <br />NOTE <br />GENERAL POWER NOTES <br />11.19.10 EN09 <br />THAT REUIRES POWER1 <br />ARANGE ALLBOX(ES) <br />TO <br />MOUNTNTO <br />INTERRUPTIONS�ORK <br />THE STORE4TO BE ACCOMPLISHED <br />TOP SI EE OF BOTTSOM CHORD OF BAR: JOIST. INSTALL <br />AFTER NORMAL STORE BUSINESS HOURS. NOTIFY THE <br />FURNISHED POWER POLE AND TERMINATE WIRING TO <br />STORE MANAGER AND THE WALMART CONSTRUCTION <br />JUNCTION BOX. PROVIDE UNISTRUT SUPPORTS AND <br />MANAGER A MINIMUM OF 48 HOURS IN ADVANCE OF ALL <br />HARDWARE TO SECURE TELEPOWER POLE PLUMB TO <br />STORE POWER INTERRUPTIONS. STORE MANAGER MUST <br />BUILDING STRUCTURE. REF POWER POLE <br />ALLOW FOR POWERING DOWN OF COMPUTER SYSTEMS, <br />CONNECTION DETAIL. <br />MOVING AFFECTED PRODUCT, MODIFICATION OF <br />WALMART AFTER-HOURS WORK SCHEDULES, <br />2. <br />PROVIDE LIQUID -TIGHT FLEXIBLE METAL CONDUIT <br />COORDINATION WITH OTHER TRADES, AND OTHER <br />AND WIRING FROM DISCONNECT SWITCH OR <br />CRITICAL SCHEDULING CONCERNS. PROVIDE <br />JUNCTION BOX TO EQUIPMENT KNOCKOUT OR <br />TEMPORARY POWER AS REQUIRED. INSTALLATION OF <br />ELECTRICAL CONNECTION POINT. <br />NEW EQUIPMENT SHALL BE COMPLETED AND THE <br />POWER SYSTEM TESTED AND RE -ENERGIZED PRIOR TO <br />3. <br />WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE <br />START OF BUSINESS THE FOLLOWING MORNING NO <br />RATING DIFFERS FROM SIZE PROVIDED, CHANGE OUT <br />LATER THAN A TIME ESTABLISHED BY THE STORE <br />BRANCH CIRCUIT WIRING AND OVERCURRENT DEVICE <br />MANAGER AND THE WALMART CONSTRUCTION <br />TO APPROPRIATE RATING PER NEC. <br />MANAGER. <br />4. <br />UPON COMPLETION OF ELECTRICAL INSTALLATION <br />AND PRIOR TO ENERGIZING CIRCUIT: <br />A INSPECT WIRE AND CABLE FOR PHYSICAL <br />DAMAGE. <br />B. PERFORM CONTINUITY TEST. <br />C. VERIFY PROPER PHASING CONNECTION TO ALL <br />THREE PHASE MOTOR LOADS. <br />POWER DROP NOTES <br />03.27.15 EN01 a <br />1. <br />POWER DROPS WILL BE IDENTIFIED BY AN IPTV TAG <br />OR POWER TAG, I.E. 44A, 46E, ETC. ALL CHECKOUT <br />POWER SHALL BE CONSIDERED POWER DROPS. <br />2. <br />A REVISION OF THIS PLAN BASED ON THE FINAL <br />MERCHANDISE LAYOUT MAY BE ISSUED TO SHOW <br />FINAL LOCATIONS FOR THE POWER DROPS. IF THE <br />MERCHANDISE PLAN DOES NOT CHANGE, THIS PLAN <br />WILL NOT BE REISSUED. PROVIDE CIRCUITRY TO <br />DISPLAY RACKS AS THE RACKS ARE SET. IN ADDITION, <br />THE FOLLOWING POWER DROP NOTES APPLY: <br />A. THERE WILL BE NO ADDITIONAL CHARGE FOR <br />DROP RELOCATION WITHIN POWER DROP ZONES <br />DEFINED ON DRAWING. <br />B. AT CLOSE OF PROJECT THE GENERAL <br />CONTRACTOR AND CONSTRUCTION MANAGER <br />SHALL REVIEW ADDITIONAL OR DELETED POWER <br />DROPS WITHIN EACH ZONE TO VERIFY ANY <br />ADDITIONAL CHARGES OR CREDITS THAT APPLY <br />DUE TO CHANGES. <br />C. ADDING OR SUBTRACTING A POWER DROP TO <br />ANY ZONE WILL RESULT IN A CHARGE OR CREDIT <br />ACCORDING TO SPECIAL CONDITIONS. <br />3. <br />PROVIDE JUNCTION BOX AND CIRCUITRY TO NEAREST <br />JOIST ABOVE LOCATION SHOWN ON DRAWING. <br />EXTEND CONDUIT AND CIRCUITRY FROM JUNCTION <br />BOX TO ENDCAP OF DISPLAY RACK (AWAY FROM <br />ACTION ALLEY). <br />4. <br />PROVIDE CONDUIT, RECEPTACLE(S) AND FINAL <br />CONNECTIONS AT DISPLAY RACK SHELVING PER <br />POWER DROP SCHEDULE UNLESS NOTED <br />OTHERWISE ON DRAWING. VERIFY EXACT HEIGHT <br />AND LOCATION OF RECEPTACLE(S) WITH STORE <br />PLANNING SET-UP SUPERVISOR PRIOR TO <br />INSTALLATION. <br />BL1 A <br />16.470 <br />5. <br />POWER DROPS FED FROM TRACK BUSWAY:INSTALL <br />16.957 <br />PLUG-IN UNIT IF REQUIRED ON TRACK BUSWAY AT <br />POINT NEAREST TO POWER DROP(S) <br />0 <br />POWER DROP SCHEDULE <br />O <br />07.28.17 ES01 <br />NO <br />DESCRIPTION <br />VOICE/DATA BOX PRE -INSTALLED BY <br />-P CABINET MANUFACTURER. <br />OUTLET BOX PRE -INSTALLED BY CABINET <br />P MANUFACTURER. FURNISH AND INSTALL <br />RECEPTACLE, COVERPLATE, AND CIRCUITRY. <br />ALL EQUIPMENT IS SINGLE PHASE. <br />ROUTE ALL CIRCUITRY THROUGH COUNTERS <br />AND WALLS UNLESS OTHERWISE NOTED. <br />PHOTO LAB POWER <br />1 /4" = V-0" <br />PD1 <br />MOUNT RECEPTACLE(S) ON TOP OF DISPLAY UNIT <br />(S) <br />OPD2 <br />MOUNT RECEPTACLE(S) 6" ABOVE BASE OF <br />DISPLAY UNIT(S) SO THAT RECEPTACLE(S) AND <br />O <br />CONDUIT DO NOT INTERFERE WITH SHELF HEIGHT <br />ADJUSTMENTS <br />PD3 <br />PROVIDE DIRECT CONNECTION TO EQUIPMENT <br />PD4 <br />OPEN STRUCTURE: MOUNT RECEPTACLE AT BAR <br />JOIST AND INSTALL FURNISHED CORD REEL. <br />LAY -IN CEILING: PROVIDE RECESSED CEILING <br />RECEPTACLE AND INSTALL FURNISHED CORD <br />REEL BELOW CEILING. CORD REEL SHALL BE <br />MOUNTED TO CEILING FAN RATED JUNCTION BOX <br />SECURED TO LAY -IN CEILING WITH T-BAR BOX <br />HANGER. PROVIDE 1 /2" THREADED STEEL ROD <br />FROM JUNCTION BOX TO BOTTOM OF <br />STRUCTURAL JOIST OR CHANNEL STRUT <br />BRIDGING ABOVE FOR SUPPORT. <br />20A WIRE SIZING SCHEDULE <br />ALL WIRE SIZES SHOWN ON PANEL SCHEDULES <br />ARE INTENDED TO BE MINIMUM ACCEPTABLE WIRE <br />SIZE. <br />THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE <br />PLAN WIRE FOR 20 AMP CIRCUITS (120 AND 277 VOLT). <br />LENGHTS (IN FEET) ARE INTENDED TO BE MAXIMUM. <br />O1 O2 0 <br />O4 O5 (D C) <br />O7 0 <br />0 <br />10 11 12 13 14 <br />BUSWAY BL1A AND BL1B FEED <br />FROM PANEL L1 D2 LOCATED IN <br />ELECTRICAL ROOM 41 <br />� KEY PLAN <br />120 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />200 FT. <br />325 FT <br />490 FT <br />770 FT. <br />6-10 AMPS <br />100 FT <br />160 FT. <br />245 FT <br />385 FT, <br />11-15 AMP <br />70 FT., <br />110 FT., <br />165 FT., <br />255 FT. <br />277 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />480 FT. <br />760 FT <br />1170 F <br />.1865 FT <br />6-10 AMPS <br />240 FT. <br />380 FT <br />585 FT <br />930 FT. <br />11-15 AMPT <br />160 FTI <br />250 FTJ <br />390 FTj <br />620 FT. <br />ELECTRICAL KEYNOTES <br />16.470 FURNISH AND INSTALL NEW 20 AMP, 120 <br />VOLT CIRCUIT(S). FEED FROM PANELBOARD <br />AS INDICATED. PROVIDE 20A-1P CIRCUIT <br />BREAKER IF NEEDED. EC SHALL MATCH <br />TYPE AND AIC RATINGS OF EXISTING <br />CIRCUIT BREAKERS. EC SHALL VERIFY PRIOR <br />TO ROUGH -IN THAT EXISTING PANELBOARD <br />HAS SPARE CAPACITY TO ACCOMMODATE <br />ADDITIONAL LOAD. <br />16,492 EC SHALL COORDINATE WITH GENERAL <br />CONTRACTOR AND ARCHITECTURAL <br />DEMOLITION PLANS THE EXTENT OF <br />ELECTRICAL DEMOLITION. REMOVE CONDUITS <br />AND WIRES ALL THE WAY BACK TO <br />ORIGINATING JUNCTION BOXES OR <br />PANELBOARDS. DEMOLITION SHALL NOT <br />AFFECT ACTIVE CIRCUITS. LABEL <br />DEMOLISHED CIRCUIT(S) IN PANELBOARDS <br />AS "SPARE". COORDINATE EXACT <br />REQUIREMENTS WITH EXISTING CONDITIONS <br />PRIOR TO BID. <br />16.957 CONNECT CIRCUIT(S) TO EXISTING BRANCH <br />CIRCUITRY. MINIMUM WIRE SIZE AND <br />PANELBOARD CIRCUIT ARE NOTED. VERIFY <br />SIZE, RATING AND CONDITION OF EXISTING <br />BRANCH CIRCUIT CONDUIT AND WIRE PRIOR <br />TO USE TO ENSURE THAT THEY MEET <br />REQUIRED SIZE, AND ALL U.L. RATINGS AND <br />REPLACE AS REQUIRED. <br />A <br />EXISTING CONDITIONS WERE TAKEN FROM EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A <br />ORIGINAL DRAWINGS AND MAY NOT REFLECT THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />SHALL CAREFULLY COORDINATE NEW WORK AND THE WORK PROPERLY. NO ADDITIONAL COMPENSATION <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT <br />EXISTING CONDITIONS. OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS <br />WITH THIS KNOWLEDGE. <br />o_ <br />e( N O O <br />p <br />co <br />gn. <br />>r <br />B <br />LIJw ,may, 1,. 0 <br />Iz- <br />TzaF zWaNW,— <br />Owz <br />W 0 I20ulx aSul, a8 <br />� as �~oaoo�=ZaW= <br />0 ww g 0a aw WP0 � <br />O Z Q JWa'F�� <br />Li O� >z< zo z k F_ F_ p <br />Z aQa��Wa3X�nwoar <br />O <br />z3c�eo <br />~ vai asokDo'vgi��`w'�aZz <br />Q O-=www>_ U. n0 <br />D xZ <br />a i0-jou.WUWZ0w <br />a LomNw=zkow000 <br />�np��aamN o <br />z <br />a <br />I— <br />D <br />Ln <br />z <br />0 <br />U <br />a <br />%60 <br />O © <br />O O <br />w <br />� <br />z <br />Q <br />^rz, <br />O <br />x <br />C/D <br />0 <br />� <br />z <br />W <br />0 <br />.-. <br />O <br />F-- <br />o <br />r-I <br />w <br />N <br />z <br />C� <br />0 <br />ISSUE BLOCK <br />CHECKED BY: <br />JPM <br />DRAWN BY: <br />DG <br />PROTO: <br />EOTF <br />DOCUMENT DATE: <br />04/01 /19 <br />.% ?fkADEFP Ole <br />Nz�0 .,\C•E•NSc� <br />��•' Nd769 .(P <br />Mar 29, 2019 <br />POWER <br />PLANS <br />SHEET: <br />El <br />