My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7646 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7646 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:51:40 AM
Creation date
2/18/2025 3:43:17 PM
Metadata
Fields
Template:
Building Plans
Street #
7646
Location
Gall Blvd
Contractor
Chipotle Restaurant
Building Plans - Permit #
2638
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 23 .38 13 13 <br />SPECIFICATIONS <br />TAGi Commercial Kitchen Ventilation Hoods, Listed Commercial Kitchen Hoods <br />PART 1 - GENERAL <br />B. Duct sizes, CFM, and static pressure requirements shall be as shown <br />on drawings. Static pressure requirements shall be precise and <br />accuratei air velocity and volume Information shall be accurate within <br />1-ft Increments along the length of the ventilator. <br />corrected In a Manner acceptable to Installer. <br />3.2 INSTALLATION <br />1.1 SUMMARY <br />A. The ND2 series is a Type I, wall canopy hood for use over 600'F <br />cooking surface temperatures. The aerodynamic design Includes a <br />mechanical baffle and performance enhancing Up for exceptional <br />capture and containment. <br />B. The hood shall have the size, shape, and performance specified on <br />drawings. <br />1.2 SUBMITTALS <br />A. The manufacturer assumes no liablUty for the use or results of <br />use from this document. Specifications are to be reviewed by the <br />engineer to confirm the pro,ject's requirements and meet Federal.. <br />State, and Local codes and regulations. <br />B. As the manufacturer continues product development, it reserves <br />the right to change design and specifications without notice. <br />C. The manufacturer shall supply complete computer generated <br />submittal drawings, including hood section view(s) and hood plan <br />vlew(s). These drawings must be available to the engineer, architect, <br />and owner for their use In construction, operation, and maintenance. <br />1.3 QUALITY ASSURANCE <br />A. This hood is ETL-listed to standard UL710, ULC710, and ULC-S646 <br />when Installed in accordance with these installation Instructions and <br />National Fire Protection Association Standard `NFPA 96, Standard for <br />Ventilation Control and Fire Protection of Commercial Cooking <br />Operations." <br />B. Built -In compliance with NSF/ANSI Standard 2. <br />C. The hood shall be ETL Listed asi <br />1. `Exhaust Hood Without Exhaust Damper." <br />2. ETL Sanitation Listed and built In accordance with NFPA 96. <br />3. The ETL label shall list temperature rating(s) and minimum CFM/ft <br />rating(s). <br />1.4 WARRANTY <br />A. All units shall be provided with the following standard warranty, <br />1. This equipment Is warranted to be free from defects in materials <br />and workmanship, under normal use and service, for a period of <br />2-years from date of shipment. <br />B. The manufacturer shall not be liable for incidental and consequential <br />losses and damages potentlally attributable to malfunctioning <br />equipment. Should any part of the equipment prove to be defective <br />In materlal or workmanship within the 2-year warranty period, upon <br />examination by the manufacturer, such part will be repaired or <br />replaced by manufacturer at no charge. The buyer shall pay all <br />labor costs Incurred In connection with such repair or replacement. <br />Equipment shall not be returned without manufacturer's prior <br />authorization, and all returned equipment shall be shipped by the <br />buyer, freight prepaid to a destination determined by the <br />manufacturer. <br />C. Refer to Manufacturers Operation, Installation, and Maintenance <br />(OIM) Manual for detalled descriptions of what Is/is not covered and <br />contact Information for warranty claims. <br />PART 2 - PRODUCTS <br />2.1 GENERAL <br />A. Construction shall be dependent on the structural appUcatlon to <br />minimize distortion and other defects. All seams, ,joints, and <br />penetrations of the hood enclosure to the lower outermost <br />perimeter, which directs and captures grease -laden vapor and <br />exhaust gases, shall have a liquid -tight continuous external weld in <br />accordance with NFPA 96. <br />2.2 CONSTRUCTION <br />A. Construction shall be type 430 stainless steel. <br />B. Double wall Insulated front to eliminate condensation and Increase <br />rigidity on wide sizes. The Insulation shall have a flexural modulus of <br />475 El, meet UL 181 requirements and be In accordance with NFPA 90A <br />and 90B. <br />C. Hood shall be equipped with a minimum of four connections for <br />hanger rods. Hood lengths greater than 12 ' will have added hangers. <br />D. Exhaust duct collar to be 4 " high with flange. <br />E. The grease drain system shall be an enclosed Integral part of the <br />hood back and have slopes with an exposed, removable 1/2 grease <br />cup to facilitate cleaning. <br />F. An Integral baffle to direct grease laden vapors toward the <br />exhaust filter bank. <br />G. Hood shall be furnished with UL classif led filters, supplied in size <br />and quantity as required by ventilator. <br />H. All seams shall be welded and have stainless steel on exposed <br />surfaces, <br />2.3 LIGHTING <br />A. L55 Series canopy light fixture, Includes clear thermal and shock <br />resistant globe. <br />2.4 FILTERS <br />A. Stainless Steel Captrate Solo filter with hook, ETL Listed. <br />Particulate capture efficiencyo 85X efficient at 9 microns, 76X <br />efficient at 5 microns. <br />2.5 OPTIONS <br />A. Fire Suppression Systems UL 300 fire suppression system. <br />B. Optional perforated supply plenum shall provide make-up air <br />discharged below the cooking equipment. <br />1. Perforated diffuser plates shall be Included In the design to <br />provide even air distribution. <br />2. Unexposed surfaces shall be constructed of aluminized steel. <br />Plenum shall be Insulated to prevent condensation. <br />3. Dual Plenum (AC-PSP) <br />C. Hood Mounted Utility Cabinet - Cabinet can store listed fire <br />suppression system, listed components, pre -wired electrical controls. <br />2.6 ACCESSORIES <br />A. End Panel(s) maximize hood performance and eliminate the effects of <br />cross drafts in the kitchen. Units constructed of stainless steel <br />and sized according to hood width and cooking equipment. Exposed <br />edges hemmed for safety and rigidity. Selected panelso <br />1. Quarter End Panel <br />B. Wrapper(s) may be Installed from the factory or fleld Installed. <br />Wrapper(s) selectedo <br />1. Wrapper <br />C. Miscellaneous option(s) selectede <br />1. Full Dimension Hanging Bracket-Unistrut added to allow for <br />various hood mounting locations. <br />2. Insulation for Back of Hood -Backside of hood is fully Insulated. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine areas and conditions under which the system Is Installed. Do <br />not proceed with work until unsatisfactory conditions have been <br />A. Install in accordance with manufacturer's Instructions, drawings, <br />written specifications, manufacturer's installation manual, and all <br />applicable building codes. <br />c/OB CHIPOTLE ZEPHYRHILLS #3687 <br />i <br />' r�;; <br />TIP <br />' <br />REV <br />,S"C14LS 1/40 = 1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.