Laserfiche WebLink
37 1/2 <br />2- <br />41 7/8 <br />33 <br />DUC <br />TWORK BETWEEN <br />EXHAUST RISER ON HOOD <br />AND FAN (BY OTHERS). <br />41 7/8 <br />33 <br />- ROOF MOUNTED FANS. <br />- RESTAURANT MODEL. <br />- UL705 AND UL762 AND ULC-S645. <br />- AMCA SOUND AND AIR CERTIFIED. <br />- WIRING FROM MOTOR TO DISCONNECT SWITCH. <br />- NEMA 3R SAFETY DISCONNECT SWITCH. <br />- HIGH HEAT OPERATION 300•F <149.0. <br />- GREASE CLASSIFICATION TESTING. <br />NORMAL TEMPERATURE TEST <br />t8 EXHAUST FAN MUST OPERATE CONTINUOUSLY <br />WHILE EXHAUSTING AIR AT 300•F C149.0 <br />UNTIL ALL FAN PARTS HAVE REACHED <br />THERMAL EQUILIBRIUM, AND WITHOUT ANY <br />DETERIORATING EFFECTS TO THE FAN WHICH <br />WOULD CAUSE UNSAFE OPERATION. <br />ABNORMAL FLARE-UP TEST <br />EXHAUST FAN MUST OPERATE CONTINUOUSLY <br />WHILE EXHAUSTING BURNING GREASE VAPORS <br />AT 600•F <316*0 FOR A PERIOD OF <br />15 MINUTES WITHOUT THE FAN BECOMING <br />DAMAGED TO ANY EXTENT THAT COULD CAUSE <br />AN UNSAFE CONDITION. <br />GREASE BOX, <br />REMOVE HINGE KIT LABEL FROM <br />THE FAN BASE, <br />MIAMI DADE CERTIFICATION - <br />NOA-1 ALUMINUM UPBLAST, <br />2 YEAR PARTS WARRANTY. <br />W. <br />VENTED <br />CURB. <br />6 GAUGE <br />TEEL <br />;ONSTRUCTION. <br />®r <br />` / ROOF OPENING <br />31 DIMENSIONS. <br />31 <br />PITCHED CURBS ARE AVAILO <br />FOR PITCHED ROOFS$ <br />SPECIFY PITCHi 12' <br />EXAMPLEo 7/12 PITCH = 30' SLOPE. <br />0' <br />JOB CHIPOTLE ZEPHYRHILLS #3687 <br />LOCATION Ze h rhills, FL, 33541 <br />PATT 7/28/2021 JOB # 4681827 <br />.9FO # 9 MUFAr BYJMB-40 <br />REV SCMLS 3/8' = i'-0' <br />