My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7646 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7646 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:51:40 AM
Creation date
2/18/2025 3:43:17 PM
Metadata
Fields
Template:
Building Plans
Street #
7646
Location
Gall Blvd
Contractor
Chipotle Restaurant
Building Plans - Permit #
2638
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL POWER PLAN NOTES <br />1 SHOW ROOM WINDOW RECEPTACLE. COORDINATE EXACT RECEPTACLE MOUNTING HEIGHT IN THE FIELD. LOCATION SHALL BE IN <br />THE DRYWALL IMMEDIATELY ABOVE THE MAIN STORE -FRONT WINDOW AND AS SHOWN IN THE DINING ROOM ELECTRICAL <br />ELEVATIONS ON SHEET E700. <br />2 ICE MACHINE ELECTRICAL TIE-IN. COORDINATE EXACT LOCATION WITH EQUIPMENT INSTALLER PRIOR TO ROUGH -IN. PROVIDE <br />L5-20P FLANGED INLET WIRED TO THE REMOTE CONDENSER. PROVIDE 48" CORDS, ONE WITH 5-20P END AND ONE WITH L5-20R <br />END, FROM ICE MAKER TO RECEPTACLE AND FLANGED INLET. <br />3 CONNECT RECEPTACLES SERVING EQUIPMENT BELOW THE KITCHEN HOOD TO THE CIRCUITS SHOWN THROUGH THE CONTACTOR <br />INTEGRAL TO THE HOOD CONTROL PANEL. INTEGRAL CONTACTOR SHALL BE INTERLOCKED TO HOOD FIRE PROTECTION SYSTEM <br />SO THAT RECEPTACLES ARE DE -ENERGIZED UPON ACTIVATION OF HOOD FIRE PROTECTION SYSTEM. <br />4 JUNCTION BOX FOR EXTERIOR SIGN LIGHTING. COORDINATE EXACT LOCATION WITH CHIPOTLE'S CONSTRUCTION MANAGER AND <br />THE SIGN INSTALLER PRIOR TO ROUGH -IN. CONNECTTO CIRCUIT SHOWN THROUGH THE EXTERIOR LIGHTING CONTACTOR PANEL <br />AS SHOWN IN DETAIL 5/E710. <br />5 PROVIDE 4" OCTAGONAL JUNCTION BOX WITH SCREW THREADS SET AT THE 2 & 8 O'CLOCK POSITIONS FOR THE ANSUL PULL <br />STATION. PROVIDE A 1/2" CONDUIT FROM THE J-BOX TO 6" ABOVE THE CEILING AND TERMINATE WITH A CONDUIT BUSHING. <br />COORDINATE EXACT LOCATION WITH THE ANSUL SYSTEM INSTALLER AND THE FIRE MARSHALL PRIOR TO ROUGH -IN. <br />6 HOOD CONTROL PANEL AND ANSUL CABINET SHALL BE LOCATED WITHIN THE INTEGRAL HOOD UTILITY CABINET. PROVIDE FINAL <br />ELECTRICAL CONNECTIONS PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS NECESSARY FOR A COMPLETE AND <br />OPERATIONAL SYSTEM. <br />7 SHOW ROOM WINDOW RECEPTACLE. COORDINATE EXACT RECEPTACLE MOUNTING HEIGHT IN THE FIELD. LOCATION SHALL BE IN <br />THE CEILING IMMEDIATELY ABOVE THE STOREFRONT WINDOW. <br />8 PROVIDE AN EMPTY SINGLE GANG J-BOX FOR VOLUME CONTROLS. INSTALL THE CAT5 VOLUME CONTROL WIRE FURNISHED BY <br />THE TENANT FROM THE J-BOX TO THE AMPLIFIER IN THE OFFICE WITH 3 FEET OF SLACK AT EACH END. <br />9 COORDINATE DATA/POWER RECEPTACLE MOUNTING REQUIREMENTS WITH THE CASE WORK INSTALLER PRIOR TO ROUGH -IN. <br />10 PROVIDE ROUGH -INS FOR LAUNCHPORT AS NOTED AND INSTALL LAUNCHPORT FURNISHED BY CHIPOTLE PER THE <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS WITH THE WALLSTATION AT 62" AFF AND THE WALL PLATE DIRECTLY ABOVE <br />THE WALLSTATION AT 90" AFF. SEE ARCHITECTURAL DRAWINGS FOR HORIZONTAL LOCATION OF WALL PLATE AND <br />WALLSTATION. PROVIDE SINGLE -GANG J-BOX AT 90" AFF FOR THE WALL PLATE INSTALLATION, A 4" X 2-1/8" DEEP OCTAGON <br />1-BOX AT 62" AFF FOR THE WALLSTATION INSTALLATION, AND A 3/4" CONDUIT BETWEEN THE TWO J-BOXES. PROVIDE A 22 <br />GAUGE 2 CONDUCTOR CABLE BETWEEN THE WALLSTATION AND THE WALL PLATE J-BOXES WITH 6" SLACK AT EACH END. <br />PROVIDE RECEPTACLE AT 90" AFF NEXT TO THE WALL PLATE J-BOX AS SHOWN. THE RECEPTACLE AND WALL PLATE AT 90" AFF <br />SHALL BE CONCEALED FROM PUBLIC VIEW BY THE HOOD. <br />11 PROVIDE AN EMPTY 1" CONDUIT WITH PULL STRING FROM THE BASE BUILDING'S TELEPHONE SERVICE ENTRANCE LOCATION TO <br />THE SPACE ABOVE THE OFFICE CEILING. <br />12 PROVIDE A SUITABLE LENGTH OF LIQUID -TIGHT CONDUIT TO THE EXHAUST FAN EF-1 TO ALLOW THE EXHAUST FAN TO HINGE <br />COMPLETELY OPEN WHEN THE VIROGUARD SYSTEM IS INSTALLED. <br />13 AFTER THE FAX LINE, POS, AND OFFICE EQUIPMENT IS INSTALLED PROVIDE CHILDPROOF RECEPTACLE COVERS ON UNUSED IG <br />RECEPTACLES AT THE FAX LINE, POS, AND OFFICE. <br />14 PROVIDE ONE PHASE, ONE NEUTRAL, AND ONE GROUND CONDUCTOR FROM THE ICE MAKER TO THE REMOTE CONDENSING <br />UNIT. <br />15 UNIT SHALL HAVE AN INTEGRAL NON -FUSED DISCONNECT SWITCH. <br />16 INSTALL DOOR CHIME AT 96" AFF. SEE ARCHITECTURAL DOOR EQUIPMENT FOR EQUIPMENT INFORMATION. <br />17 INSTALL THE BYPASS DISTRIBUTION PANEL (BDP) FURNISHED BY THE TENANT. INSTALL PER THE MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS AND DETAIL 3/E710. <br />18 ROUGH -INS TO SERVE LINE AND POS EQUIPMENT ARE UNDERGROUND. COORDINATE ROUGH -IN REQUIREMENTS AND <br />LOCATIONS WITH EQUIPMENT MANUFACTURER PRIOR TO ROUGH -IN. <br />19 ROOFTOP UNIT SHALL HAVE AN INTEGRAL UNIT -MOUNTED GFCI RECEPTACLE. PROVIDE CONNECTION TO CIRCUIT SHOWN. <br />20 ICE MAKER RECEPTACLES SHALL BE CONCEALED BEHIND THE ICE MAKER. COORDINATE LOCATION WITH ACTUAL WIDTH OF ICE <br />MAKER. <br />21 PROVIDE VERTICAL METAL DIE CAST WEATHERPROOF WHILE IN USE OUTLET COVER ON RECEPTACLES AT COOK LINE. COVER <br />SHALL BE INTERMATIC WP1010MXD FOR SINGLE GANG BOXES AND WP1030MXD FOR DOUBLE GANG BOXES. NO SUBSTITUTIONS <br />SHALL BE ACCEPTED. <br />22 LABEL BATTERY -PROTECTED RECEPTACLES "BATTERY -PROTECTED: DISCONNECT AT PANEL BDP". <br />23 LABEL MAIN DISCONNECT SWITCH AND PANEL A "WARNING: BATTERY -PROTECTED RECEPTACLES IN USE. DISCONNECT AT PANEL <br />BDP." <br />24 PROVIDE A NEMA 5-20P FLANGED INLET (LEVITON MODEL #15378-C) AND A SINGLE NEMA 5-20R RECEPTACLE IN OFFICE FOR <br />CONNECTION TO A CENTRAL UPS SYSTEM. CONNECT THE FLANGED INLET AND THE SINGLE RECEPTACLE TO THE TERMINAL BLOCK <br />IN THE BDP PER THE MANUFACTURER'S INSTRUCTIONS. PROVIDE FINAL CONNECTION FROM FLANGED INLET TO THE OUTPUT OF <br />THE UPS USING A 2'-LONG 20A EXTENSION CORD. PLUG THE UPS INTO THE SINGLE RECEPTACLE. <br />25 CONNECT RESTROOM EXHAUST FAN TO CIRCUIT SHOWN THROUGH THE LIGHTING CONTROL PANEL (LCP). <br />26 INSTALL 16/2 SPEAKER WIRE FURNISHED BY OWNER. INSTALL SPEAKER WIRE BETWEEN SPEAKERS IN THE DINING ROOM AS <br />SHOWN AND TO THE AMPLIFIER IN THE OFFICE WITH 3 FEET OF SLACK AT EACH END. THERE SHALL BE TWO SPEAKER WIRE <br />HOMERUNS WITH THREE SPEAKERS ON EACH HOMERUN. SEE ARCHITECTURAL PLANS FOR SPEAKER LOCATIONS. ADJUST EACH <br />SPEAKER 70V TAP SETTING TO BE 15 WATTS. <br />27 PROVIDE POWER CONNECTIONS TO ISLAND PREP TABLE PER DETAIL 2/E710. PROVIDE GFCI DUPLEX RECEPTACLES IN THREE <br />J-BOXES INTEGRAL TO PREP TABLES (FOR UNDERCOUNTER REFRIGERATOR, HOT HOLDING CABINET, AND GENERAL RECEPTACLE). <br />28 PROVIDE GFCI RECEPTACLE AND J-BOX AND INSTALL CO2 ALARM FURNISHED BY CO2AS AS SHOWN IN DETAIL 4/E710. <br />29 PROVIDE J-BOX AND INSTALL CO2 ALARM REMOTE DISPLAY UNIT FURNISHED BY CO2AS AS SHOWN IN DETAIL 4/E710. <br />30 INSTALL WALK -IN -COOLER EXTERNAL READOUT THERMOMETER REMOTE PROBE ON WALL OPPOSITE FROM DOOR AS SHOWN. <br />ROUTE TEMPERATURE PROBE WIRE ABOVE WALK-IN COOLER CEILING PANELS, SEAL PENETRATIONS THROUGH THE CEILING <br />PANELS, AND SECURE VERTICAL PROBE WIRE TIGHT TO WALLS. NO EXCESS PROBE WIRE SHALL BE WITHIN THE WALK-IN COOLER. <br />31 PROVIDE RECEPTACLE FOR RESTROOM HAND SINK FAUCET AS SHOWN IN DETAIL 14/P700. <br />32 LABEL UTENSIL COUNTER RECEPTACLES "TRACTOR BEVERAGE", "ICE MAKER/IMSB", AND "SODA FOUNTAIN". <br />33 PROVIDE 1" CONDUITS FROM LOW -VOLTAGE J-BOXES AT POS COUNTER CONCEALED WITHIN THE SERVE LINE WIRING CHASE TO <br />THE WALL, THEN CONCEALED WITHIN THE WALL AND ABOVE THE CEILING TO ABOVE THE OFFICE CEILING. <br />34 PROVIDE CORD AND NEMA 5-20P PLUG FROM UTENSIL COUNTER ICE MAKER, THROUGH UTENSIL COUNTER, TO ICE MAKER <br />RECEPTACLE. <br />35 PROVIDE 4" SQUARE J-BOX ON EXTERIOR WALL FOR MOUNTING OF EXTERIOR CAMERA. SEE ARCHITECTURAL ELEVATION FOR <br />EXACT HEIGHT AND LOCATION. PROVIDE 3/4" CONDUIT WITH PULLSTRING FROM J-BOX TO ABOVE LAY -IN CEILING AREA IN <br />KITCHEN. <br />37 LABEL RECEPTACLE "UV INSECT TRAP". <br />38 INSTALL TRANSFORMER FURNISHED BY TUV WITH THE REME HALO AIR PURIFIER IN THE JUNCTION BOX ON THE EXTERIOR OF THE <br />RTU PER DETAIL 6/M700. CONNECT LINE SIDE OF THE TRANSFORMER TO THE RTU SERVICE RECEPTACLE CIRCUIT SO THAT REME <br />HALO RUNS CONTINUOUSLY. CONNECT THE LOW VOLTAGE SIDE OF THE TRANSFORMER TO THE REME HALO USING THE <br />INCLUDED BARREL PLUG. <br />39 PROVIDE (2) 10"X10"X4" JUNCTION BOXES (J-BOX #1/J-BOX #2) ON THE WALL ABOVE PANELBOARDS 6" BELOW THE LAY -IN <br />CEILING AND MOUNTED ADJACENT TO EACH OTHER AND CONNECTED BY 3/4" EMT CHASE. TEMS SHALL PROVIDE GRIDPOINT 3 <br />PHASE METER AND TRANSFORMER WITHIN 1-BOX #1 AND GRIDPOINT IOM/HUB WITHIN J-BOX #2. PROVIDE CIRCUITS SHOWN TO <br />J-BOX #1 AND TERMINATE CONDUCTORS WITH 16" SLACK WITHIN J-BOX #1 FOR FINAL CONNECTION BY TEMS. PROVIDE 1" <br />CONDUIT WITH PULL STRING FROM J-BOX #1 (THROUGH BACK OF J-BOX #1) TO PANEL A FOR THE CT WIRING THAT WILL BE <br />PROVIDED BY TEMS. PROVIDE 3/4" EMT STUB UP FROM J-BOX #2, 6" ABOVE LAY -IN CEILING WITH INSULATING BUSHING ON END. <br />PROVIDE CABLE (18-24AWG SHIELDED TWISTED PAIR) FROM J-BOX #2 TO MANAGER'S OFFICE AREA ABOVE DROP CEILING AND <br />LABEL "EMS POWER" ON BOTH ENDS OF CABLE. LEAVE 10' OF SLACK CABLING ABOVE LAY -IN CEILING AND 16" INSIDE OF J-BOX <br />#2. PROVIDE CABLE (CATS) FROM J-BOX #2 TO MANAGER'S OFFICE AREA ABOVE LAY -IN CEILING AND LABEL "RS-485 COMMS". <br />LEAVE 10' OF SLACK CABLING ABOVE LAY -IN CEILING AND 16" INSIDE J-BOX #2. SEE GRIDPOINT INSTALLATION SHEET FOR <br />40 INSTALL VEHICLE DETECTOR SYSTEM FURNISHED BY TLS SURFACE -MOUNTED ON WALL 12" BELOW CEILING AND CONNECT TO <br />,2, STROBE/CHIME AND DETECTOR LOOPS PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MAKE FINAL ADJUSTMENTS <br />TO LOOP SENSITIVITY PER THE MANUFACTURER'S INSTRUCTIONS. ONCE ALL COMPONENTS ARE INSTALLED AND OPERATIONAL <br />THE CHIIME/STROBE LIGHT SHOULD STAY ILLUMINATED AND THERE SHOULD BE A SINGLE CHIME WHEN A VEHICLE DRIVERS <br />OVER QR STOP.5 ON -,EITHER LOOP. <br />41 INSTALL WIRED DOOR BUZZER AT 96" AFF, SEE ARCHITECTURAL DOOR EQUIPMENT FOR EQUIPMENT INFORMATION. CONNECT <br />TO CIRCUIT SHOWN THROUGH THE TRANSFORMER FURNISHED WITH THE DOOR BUZZER. PROVIDE WIRING TO A BUTTON <br />ADJACENT TO THE SERVICE DOOR AND CONNECT PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />42 CONNECT BATHROOM SANITIZER TO CIRCUIT SHOWN SO THAT IT IS ENERGIZED AT ALL TIMES. <br />43 PROVIDE POWER AND LOW VOLTAGE CONNECTIONS TO DISH SANITIZING MACHINE PER DETAIL 7/E710. CONNECT THE <br />DETERGENT DISPENSER TO THE DISH MACHINE USING THE INCLUDED WIRING HARNESS PER THE MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />44 PROVIDE RECEPTACLE FOR 2-DOOR AND/OR 1-DOOR REFRIGERATOR WITH GROUND PINS TOWARDS THE BOTTOM OF THE <br />RECEPTACLE. <br />45 PROVIDE ISLAND PREP TABLE FOOD WARMER RECEPTACLE WITH GROUND PIN TOWARDS THE BOTTOM OF THE RECEPTACLE. <br />46 SEAL INTERIOR AND EXTERIOR OF CONDUITS THAT PASS THROUGH THE WALK-IN COOLER ENVELOPE PER THE NEC. <br />47 PROVIDE HORIZONTAL SINGLE -GANG J-BOX BELOW FUTURE GRIDPOINT CONTROLLER LOCATION. PROVIDE 3/4" CCNDUIT WITH <br />PULL STRING AND INSULATING BUSHING FROM 1-BOX TO 6" ABOVE OFFICE LAY -IN CEILING. <br />2 POWER ROOF PLAN <br />E110 1/8" = 1'-0" <br />(i� <br />A- 37 <br />70 <br />A- 30 -, O <br />48" <br />,— 1 1•�/ 29 <br />ov 8-17 <br />(L5-20P INLET) 60" <br />T20 <br />�ITO REMOTE <br />;'3'\ <br />prp <br />33 b <br />42 - <br />B- 8 <br />- <br />-. <br />- <br />32 <br />_... _--- <br />... _.... <br />,- <br />GFCI, 56" <br />M <br />3_._............ _.... 901i <br />10 <br />A, <br />A- 16,18,20 <br />A- 35 <br />90" 62" <br />HCP <br />m <br />k : <br />...... <br />B- 19 <br />27 <br />45 <br />y' <br />1 <br />18 <br />i <br />B- 9 B- 16,18 B- 20,22 B- 26 <br />31 <br />Consultant: <br />NATIONAL <br />E N G I N E E R IN G <br />4635 Trueman Blvd. Suite 250 <br />Hilliard, Ohio 43026 <br />Phone: (614) 751-9610 <br />Fax: (614) 552-5240 <br />Contact: Joe Jones <br />(614) 328-2024 <br />jjonesC na ' nalengineering.com <br />1 t111 i�11/fj�� <br />VX <br />E • �a1 <br />' SEATE OF ! ;; <br />Q <br />COPYRIGHT 2021 <br />THIS DRAWING IS AN INSTRUMENT OF SERVICE <br />AND AS SUCH REMAINS THE PROPERTY OF <br />CHIPOTLE MEXICAN GRILL, INC.. PERMISSION FOR <br />USE OF THIS DOCUMENT IS LIMITED AND CAN BE <br />EXTENDED ONLY BY WRITTEN AGREEMENT WITH <br />CHIPOTLE MEXICAN GRILL, INC.. <br />CHIPOTLE MEXICAN GRILL, INC. <br />PO BOX 182566 <br />COLUMBUS, OH 43218-2566 <br />TELEPHONE: (614) 318-2400 <br />INTERNET: WWW.CHIPOTLE.COM <br />00 <br />m <br />Ln <br />M <br />J <br />N <br />M <br />-' <br />= <br />0 <br />LL <br />Z <br />} <br />N <br />V <br />L <br />O <br />N <br />(/) <br />(LO <br />n <br />(V <br />Issue Record: <br />10.14.20 <br />BID SET <br />01.20.21 <br />PERMIT SET <br />04.28.21 <br />CONSTRUCTION SET <br />® <br />Revisions: <br />2 <br />01.06.21 <br />DB-07-2020 <br />3 <br />04.23.21 <br />DB-1- DB-4 <br />Drawn: Checked: <br />1EJ MPC <br />Project No. <br />2001004 <br />Contents: <br />ELECTRICAL POWER <br />PLAN <br />E110 <br />