Laserfiche WebLink
REFERENCES <br />U1ILIZE THE FOLLOWING ABBREVIATIONS AND DEFINITIONS FOR DISCERNMENT WITHIN THE DRAWINGS AND <br />SPECIFICATIONS. <br />NEC NATIONAL ELECTRICAL CODE 2005 <br />OSHA OCCUPATIONAL SAFETY AND HEALTH ACT <br />ANSI AMERICAN NATIONAL STANDARDS INSTITUTE <br />NFPA NATIONAL FIRE PROTECTION ASSOCIATION <br />ASA AMERICAN STANDARDS ASSOCIATION <br />IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS <br />NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION <br />UL UNDERWRITERS' LABORATORIES, INC. <br />IES ILLUMINATING ENGINEERING SOCIETY <br />ICEA INSULATED CABLE ENGINEERS ASSOCIATION <br />ASTM AMERICAN SOCIETY OF TESTING MATERIALS <br />ETL ELECTRICAL TESTING LABORATORIES, INC. <br />CBM CERTIFIED BALLAST MANUFACTURERS <br />EIA ELECTRONIC INDUSTRIES ASSOCIATION <br />FBC FLORIDA BUILDING CODE <br />SECTION 16010 <br />GENERAL PROVISIONS <br />THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE A COMPLETE WORKING SYSTEM <br />READY FOR THE OWNER'S OPERATION. ANY ITEM NOT SPECIFICALLY SHOWN ON THE DRAWINGS OR <br />CALLED FOR IN THE SPEC'S BUT IS NORMALLY REQUIRED TO CONFORM WITH THE INTENT, ARE TO BE <br />CONSIDERED A PART OF THE CONTRACT. <br />THE INTENT OF THESE DRAWINGS IS NOT TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE <br />CONTRACTOR IS EXP..CTED TO FURNISH AND INSTALL ALL ELECTRICAL EQUIPMENT AND ITEMS FOR <br />A COMPLETE ELECTRICAL SYSTEM. IF THE CONTRACTOR HAS QUESTIONS, OR IN THEIR OPINION FINDS <br />OMISSIONS OR ERRORS ON THE ELECTRICAL DRAWINGS, IT IS THEIR RESPONSIBILITY TO BRING IT TO THE <br />ATTENTION OF THE ELECTRICAL ENGINEER/ARCHITECT IMMEDIATELY. IF CONTRACTOR PROCEEDS WITH <br />ANY CHANGES TO THE CONTRACT DOCUMENTS WITHOUT WRITTEN PRIOR APPROVAL FROM THE ELECTRICAL <br />ENGINEER/ARCHITECT THE CONTRACTOR WILL NOT BE COMPENSATED. <br />ALL MATERIALS USED SHALL BE LISTED AND LABELED PROVIDED A STANDARD HAS BEEN ESTABLISHED FOR THE MATERIAL <br />BEING USED. INSTALLATION OF EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE LATEST EDITIONS (LION) OF THE <br />LOCAL CODES AND ORDINANCES OF THE BUILDING DEPARTMENT, THE SERVING UTILITY COMPANIES, NFPA, NATIONAL ELECTRIC <br />CODES AND ORDINANCES, INCLUDING ALL AMENDMENTS TO THE NEC EQUIPMENT, AND WHERE APPLICABLE, SHALL BE LISTED <br />AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL). THE WORKMANSHIP AND QUALITY ESTABLISHED BY <br />THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE REDUCED BY THE ABOVE MENTIONED CODES. <br />ALL EQUIPMENT SHALL BE EQUAL TO OR EXCEED THE MINIMUM REQUIREMENTS OF NEMA, IEEE, AND UL. <br />SHOULD ANY CHANGE TO THE DRAWINGS OR SPECIFICATIONS BE REQUIRED TO COMPLY WITH GOVERNMENTAL <br />REGULATIONS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER PRIOR TO ANY SUCH WORK <br />BEING EXECUTED. <br />ALL LOCAL FEES, PERMITS, AND REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY <br />DAMAGE OR THE DURATION OF THE WORK, AND SERVICES OF INSPECTION AND TESTING AUTHORITIES SHALL <br />BE OBTAINED AND PAID FOR BY THE CONTRACTOR. THE CONTRACTOR SHALL INCLUDE IN HIS BID ANY <br />COSTS TO BE INCURRED RELATIVE TO POWER SERVICE (PRIMARY AND/OR SECONDARY) AND TELEPHONE <br />SERVICE. CONTRACTOR SHALL COOPERATE FULLY WITH THE LOCAL COMPANIES WITH RESPECT TO THEIR <br />SERVICES. <br />BIDDERS ARE TO SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK BY VISITING THE <br />SITE AND FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS. THE SUBMISSION OF A BID WILL <br />BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, <br />OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN <br />BY AN EXAMINATION OF THE SITE PRIOR TO THE BID WILL NOT BE ALLOWED. <br />ALL WORK TO BE PERFORMED IN A FIRST CLASS WORKMANLIKE MANNER, AND BE INSTALLED BY A <br />LICENSED ELECTRICAL CONTRACTOR. CERTAIN MATERIALS WILL BE PROVIDED BY OTHER TRADES. <br />EXAMINE THE CONTRACT DOCUMENTS TO ASCERTAIN THESE REQUIREMENTS. CAREFULLY CHECK <br />SPACE REQUIREMENTS WITH OTHER TRADES AND THE PHYSICAL CONFINES OF THE AREA TO <br />INSURE THAT ALL MATERIAL CAN BE INSTALLED IN THE SPACES ALLOTTED THERETO INCLUDING <br />FINISHED SUSPENDED CEILINGS. MAKE MODIFICATIONS THERETO AS REQUIRED AND APPROVED. <br />TRANSMIT TO OTHER TRADES ALL INFORMATION REQUIRED FOR WORK TO BE PROVIDED UNDER <br />THEIR RESPECTIVE SECTIONS IN AMPLE TIME FOR INSTALLATION. THE CONTRACTOR SHALL ORDER <br />THE PROGRESS OF HIS WORK TO CONF <br />ORM ORM TO THE PROGRESS OF THE WORK OF THE OTHER <br />TRADES AND SHALL COMPLETE THE ENTIRE INSTALLATION AS SOON AS THE CONDITIONS OF <br />THE BUILDING WILL PERMIT. ANY COST RESULTING FROM THE DEFECTIVE OF ILL-TIMED WORK <br />PERFORMED UNDER THIS SECTION SHALL BE BORNE BY THE CONTRACTOR. <br />ANY CORRECTIONS OF DEFECTS TO BE COMPLETED BY CONTRACTOR WITHOUT ADDITIONAL <br />CHARGE AND TO INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION <br />WHICH MAY HAVE BEEN DAMAGED THEREBY. <br />THE CONTRACTOR SHALL BE TOTALLY RESPONSIBLE FOR THE SHIPPING AND STORING OF ALL <br />PRODUCTS AND MATERIALS IN A MANNER THAT WILL PROTECT THEM FROM DAMAGE AND <br />WEATHER. IF ITEMS ARE DAMAGED, TAKE IMMEDIATE STEPS TO OBTAIN REPLACEMENT OR <br />REPAIR. ANY SUCH REPAIRS SHALL BE SUBJECT TO REVIEW AND ACCEPTANCE OF THE <br />ARCHITECT/ENGINEER. <br />CONTRACTOR SHALL STORE MATERIALS IN SUITABLE SHELTER FROM THE ELEMENTS, BUT <br />READILY ACCESSIBLY FOR INSPECTION BY THE ARCHITECT/ENGINEER UNTIL INSTALLED. STORE <br />ALL ITEMS SUBJECT TO MOISTURE DAMAGE IN DRY, HEATED SPACES. <br />PROVIDE SUPPORTS, HANGERS AND AUXILIARY STRUCTURAL MEMBERS REQUIRED FOR SUPPORT <br />OF THE WORK. FURNISH AND SET ALL SLEEVES FOR PASSAGE OF RACEWAYS THROUGH STRUCTURAL. <br />MASONRY AND CONCRETE WALLS OF FLOORS AND ELSEWHERE AS WILL BE REQUIRED FOR THE <br />PROPER PROTECTION OF EACH RACEWAY PASSING THROUGH BUILDING SURFACES. <br />IF WALL MOUNTED EQUIPMENT IS TO BE SECURED TO WALLS THE USE OF STEEL BOLTS ARE TO <br />BE USED TO MAINTAIN AT LEAST 1" AIR SPACE BETWEEN EQUIPMENT AND SUPPORTING WALL. <br />GROUPS OF EQUIPMENT MAY BE MOUNTED ON ADEQUATELY SIZED STEEL ANGLES, CHANNELS, OR <br />BARS. PREFABRICATED STEEL CHANNELS PROVIDING A HIGH DEGREE OF MOUNTING FLEXIBILITY, <br />SUCH AS THOSE MANUFACTURED BY GLOB-STRUTT, KINDORF, AND UNISTRUT, MAY BE USED FOR <br />MOUNTING GROUPS OF EQUIPMENT. <br />AN ACCURATE RECORD OF ALL DEVIATIONS SHALL BE KEPT AS TO THE WORK SHOWN ON THE <br />DRAWINGS AND THAT WHICH IS ACTUALLY INSTALLED SO THAT A SET OF AS BUILT DRAWINGS <br />CAN BE MADE BY CONTRACTOR, WERE UPON COMPLETION AND ACCEPTANCE OF THE PROJECT <br />BY THE OWNER, A NEAT AND LEGIBLE SET OF PRINTS CAN BE DELIVERED. <br />THE CONTRACTOR SHALL GUARANTEE ALL MATERIAL AND WCRKMANSHIP FOR A PERIOD OF ONE (1) <br />YEAR FROM DATE OF FINAL ACCEPTANCE BY THE OWNER, EXCEPT THAT WHERE GUARANTEES OR <br />WARRANTIES FOR LONGER TERMS ARE SPECIFIED. WITHIN 24 HOURS AFTER NOTIFICATION, CORRECT <br />ANY DEFICIENCIES THAT OCCUR DURING THE GUARANTEE PERIOD AT NO ADDITIONAL COST TO THE OWNER, <br />ALL TO THE SATISFACTION OF THE OWNER. OBTAIN SIMILAR GUARANTEES FROM SUBCONTRACTORS, <br />MANUFACTURERS, SUPPLIERS AND SUBTRADE SPECIALISTS. <br />THE ELECTRICAL CONTRACTOR SHALL COORDINATE AT THE SITE PRIOR TO CONSTRUCTION WITH THE <br />LOCAL POWER COMPANY TO RELATE WORK WITH THE UTILITY COMPANY'S RESPONSIBILITIES TO MEET <br />THE OWNERS SCHEDULE. <br />CONTRACTOR SHALL PROVIDE SUBMITTALS FOR SUBSTITUTION OF MATERIALS OR EQUIPMENT SUCH AS SITE LIGHTING, <br />LIGHT FIXTURES, SWITCHGEAR, WIRING DEVICES, EMERGENCY GENERATOR/TRANSFER EQUIPMENT, AND ALL <br />SYSTEMS (FIRE ALARM, SECURITY ETC.) TEN (10) DAYS PRIOR TO BID DATE (TWO COPIES) FOR ENGINEER'S <br />APPROVAL TO SUBMIT. ENGINEER'S APPROVAL OF THE PRIOR APPROVAL PACKAGE WILL BE CONSIDERED <br />PRELIMINARY. FINAL APPROVAL WILL BE CONTINGENT UPON REVIEW OF FINAL SHOP DRAWINGS. ALL <br />PROPOSED ALTERNATES MUST BE INDUSTRY STANDARD EQUALS TO THE ITEMS SPECIFIED AS THE BASIS <br />OF DESIGN; HOWEVER, IF THE ITEMS ARE NOT CONSIDERED EQUAL BY THE ENGINEER, IT SHALL BE <br />DISAPPROVED FOR FINAL SUBMITTAL. IF ELECTRICAL CONTRACTOR/GENERAL CONTRACTOR DOES NOT <br />SUBMIT SHOP DRAWINGS TO THE ELECTRICAL ENGINEER FOR ITEMS LISTED ABOVE, ELECTRICAL ENGINEER <br />WILL NOT BE RESPONSIBLE FOR ANY, AND OR OMISSIONS OR ERRORS DUE TO SHOP DRAWINGS NOT SUBMITTED. <br />SITE FIXTURES SHALL INCLUDE A COMPUTER GENERATED POINT-TO-POINT PHOTOMETRIC CALCULATION BASED <br />ON THE PLANS (FIXTURE CHARACTERISTICS AND POLE PLACEMENT SHALL NOT BE ALTERED). THIS DIAGRAM <br />SHALL SHOW COMPOSITE VALUES OF THE ILLUMINANCE PROJECTED FROM THE ARRANGEMENT OF LIGHT <br />SOURCES AS SHOWN ON PLAN. COMPUTER PLOT DIAGRAM SHALL ALSO SHOW THE LOCATIONS OF THE POLES, <br />SPACING BETWEEN POLES, THE MOUNTING HEIGHT USED IN THE CALCULATIONS, AND THE FIXTURE CATALOG <br />NUMBER BEING USED. <br />A COMPLETE SET OF CONTRACT DRAWINGS SHALL BE MAINTAINED AT THE JOB SITE WITH COLORED MARKINGS <br />INDICATING PROGRESS OR WORK. THIS SET OF CONTRACT DRAWINGS IS TO BE SEPARATE FROM AND IN ADDITION <br />TO CONTRACTOR'S CONSTRUCTION SET. EVERY UNIT OF EQUIPMENT, DEVICE, CONDUIT AND WIRE IS TO BE <br />MARKED WHEN INSTALLED. USE GREEN TO INDICATE INSTALLATION AS SHOWN ON DRAWINGS AND USE RED <br />TO INDICATED FIELD CHANGES. UPON COMPLETION OF WORK, THIS SET OF CONTRACT DRAWINGS IS TO BE <br />TURNED OVER TO, AND BECOME PROPERTY OF THE ARCHITECT/ENGINEER. <br />THE OWNER RESERVES THE RIGHT TO REVISE THE DRAWINGS FROM TIME TO TIME TO INDICATE CHANGES IN <br />THE WORK. WHEN REVISEDRA DRAWINGS AND/OR <br />OR ANY REVISIONS ARE ISSUED THE CONTRACTOR SHALL EVALUAT <br />E <br />THE CHANGES PROMPTLY. BEFORE INSTALLATION OF ANY ITEM OR PERFORMANCE OF THE WORK INDICATED <br />BY THE REVISED DRAWING OR REVISIONS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IN <br />WRITING THAT THE REVISED DRAWINGS INVOLVE AN ADDITION OR DEDUCTION OF A SPECIFIC AMOUNT OF MONEY <br />TO THE CONTRACT PRICE. THE CONTRACTOR SHALL NOT PROCEED WITH THE REVISED WORK WITHOUT PRIOR <br />WRITTEN APPROVAL BY THE ARCHITECT/ENGINEER/OWNER OF THE COST OF THE REVISED WORK. <br />ALL LOAD DATA HAS BEEN BASED ON INFORMATION GIVEN ENGINEER/ARCHITECT AT THE TIME OF DESIGN. <br />VERIFY ALL EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. <br />FURNISH AND INSTALL DISCONNECT SWITCHES, WIRING AND CONNECTIONS ON AIR CONDITIONING SYSTEMS AS <br />SHOWN ON PLANS. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE WITH MECHANICAL CONTRACTOR <br />REGARDING SUPPLY AND INSTALLATION OF ALL REQUIRED CONTROLS. <br />SECTION 16110 <br />RACEWAYS AND BOXES <br />STANDARDS <br />EXCEPT AS MODIFIED BY GOVERNING CODES AND BY THE CONTRACT DOCUMENTS, COMPLY WITH THE <br />LATEST APPLICABLE PROVISIONS AND LATEST RECOMMENDATIONS OF THE FOLLOWING: <br />1. RIGID STEEL CONDUIT <br />a) U.L. STANDARD I <br />b A.N.S.I. C80-1 <br />c FEDERAL SPECIFICATION WW-C-581E <br />2. INTERMEDIATE METALLIC CONDUIT <br />a) U.L. STANDARD UL-1242 <br />b) FEDERAL SPECIFICATION WW-C-581E <br />3. ELECTRICAL METALLIC TUBING <br />a) U.L. STANDARD UL-7971 <br />b A.N.S.I. C80-3 <br />c) FEDERAL SPECIFICATION WW-C-563 <br />4. FLEXIBLE STEEL CONDUIT <br />a) U.L. STANDARD I <br />5. LIQUID TIGHT FLEXIBLE CONDUIT <br />a) U.L. STANDARD UL-360 <br />6. NON-METALLIC CONDUIT <br />a) U.L. STANDARD UL-651 <br />b A.N.S.I. STANDARD F512 <br />c) N.E.M.A. STANDARD TC-2 <br />d) FEDERAL SPECIFICATIONS GSA-FSS AND W-C-1094-A <br />7. WIREWAYS AND AUXILIARY GUTTERS <br />a) U.L. STANDARD UL-870 <br />DO NOT USE ALUMINUM CONDUIT FOR ANY PURPOSES. <br />SPECIFICATIONS HAVE BEEN WRITTEN WITH THE INTENT OF VARIOUS EQUIPMENT <br />BEING INSTALLED. NOT ALL EQUIPMENT MAY BE REQUIRED ON THIS PROJECT. <br />REVIEW POWER, LIGHTING PLANS AND DETAILS FOR ITEMS Al EQUIPMENT <br />THAT WILL APPLY TO THIS PROJECT. <br />RACEWAY TYPES <br />STANDARD THREADED RIGID STEEL CONDUIT. <br />1. RIGID CONDUIT HEAVY WALL GALVANIZED. <br />2. THREADED TYPE FITTINGS: ERICKSON COUPLINGS WHERE THREADED CANNOT BE USED. <br />INTERMEDIATE METALLIC CONDUIT <br />1. LIGHT WEIGHT RIGID STEEL CONDUIT. <br />2. THREADED TYPE FITTINGS: ERICKSON COUPLINGS WHERE THREADED CANNOT BE USED. <br />ELECTRICAL METALLIC TUBING <br />1. CONTINUOUS, SEAMLESS TUBING, GALVANIZED OR SHERADIZED ON THE EXTERIOR, COATED ON THE INTERIOR <br />WITH A SMOOTH HARD FINISH OF LACQUER, VARNISH, OR ENAMEL, <br />2. COUPLINGS AND CONNECTORS: <br />a INDOOR AND TWO (2") INCHES IN SIZE AND SMALLER, SHALL BE STEEL SET -SCREW TYPE FITTINGS. <br />b 2 1/2" SIZE AND LARGER MUST EMPLOY STEEL COMPRESSION GLAND FITTINGS. <br />c) OUTDOOR SHALL BE RAINTIGHT STEEL COMPRESSION GLAND FITTINGS. <br />3. INDENT TYPE FITTINGS SHALL NOT BE USED. <br />4. ALL CONNECTORS SHALL HAVE INSULATED THROAT. <br />5. WHERE INSTALLED IN SLAB OR CONCRETE WORK, PROVIDE APPROVED CONCRETE TIGHT FITTINGS. <br />FLEXIBLE STEEL CONDUIT <br />1. SINGLE STRIP, CONTINUOUS, FLEXIBLE INTERLOCKED, DOUBLE -WRAPPED STEEL, GALVANIZED INSIDE AND OUTSIDE, <br />FORMING SMOOTH INTERNAL WIRING CHANNEL. <br />2. MAXIMUM LENGTH: (SIX 6) FEET. <br />3. EACH SECTION OF RACEWAY MUST CONTAIN AN EQUIPMENT GROUNDING WIRE BONDED AT EACH END AND SIZED <br />AS REQUIRED. PROVIDE CONNECTORS WITH INSULATING BUSHINGS. <br />4. STEEL SQUEEZE -TYPE OR STEEL SET SCREW TYPE FITTINGS. <br />LIQUID TIGHT FLEXIBLE ELECTRICAL CONDUIT <br />1. SAME AS FLEXIBLE STEEL CONDUIT EXCEPT WITH TOUGH, INSERT WATER -TIGHT PLASTIC OUTER JACKET. <br />2. CAST MALLEABLE IRON BODY AND GLAND NUT, CADMIUM PLATED WITH ONE-PIECE BRASS GROUNDING BUSHINGS <br />WHICH TREAD TO INTERIOR OF CONDUIT. SPIRAL MOLDED VINYL SEALING RING BETWEEN GLAND NUT AND <br />BUSHING AND NYLON INSULATED THROAT. <br />NON-MATALLIC RACEWAY <br />1. COMPOSED OF POLYVINYL CHLORIDE SUITABLE FOR 90 DEGREES C. <br />2. RACEWAY, FITTINGS, AND CEMENT MUST BE PRODUCED BY THE SAME MANUFACTURER WHO MUST HAVE HAD <br />A MINIMUM OF TEN (10) YEARS EXPERIENCE IN MANUFACTURING THE PRODUCTS <br />3. MATERIALS MUST HAVE A TENSILE STRENGTH OF 7,000-7,200 PSI AT 73.4 DEGREES F., FLEXURAL STRENGTH <br />OF 12,000 PSI AND COMPRESSIVE STRENGTH OF 9,000 PSI. <br />4. ALL JOINTS SHALL BE SOLVENT CEMENTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE MANUFACTURER. <br />ALL UNDERGROUND RACEWAYS SHALL BE A MINIMUM OF 3/4" GALVANIZED RIGID STEEL CONDUIT OR SCHEDULE 40 PVC. <br />ALL OTHER RACEWAYS TO COMPLY WITH GOVERNING CODES. WHERE RIGID STEEL CONDUIT IS USED, IT SHALL BE <br />COMPLETELY COATED WITH AN ALKALI AND RUST RESISTANT BITUMASTIC PAINT, KOPPER NO. 50, AND THREADS SHALL <br />BE COATED WITH ZINC CHROMATE. RIGID STEEL SHALL ALSO BE USED WHEN CONDUIT IS EXPOSED TO EXTERIOR <br />ENVIRONMENT SUCH AS EXTERIOR OF BUILDING OR WHERE IT IS EXPOSED AND SUBJECT TO DAMAGE, INSIDE OF <br />BUILDING. ALL BOXES SHALL BE RECESSED (FLUSH) IN WALLS OR CEILINGS WHENEVER POSSIBLE. <br />RACEWAYS IN HUNG CEILING SHALL BE RUN ON AND SECURED TO SLAB OR PRIMARY STRUCTURAL MEMBERS OF CEILING, <br />NOT TO LATHING CHANNELS OR T-BARS, Z-BARS, OR OTHER ELEMENTS WHICH ARE THE DIRECT SUPPORTS OF THE <br />CEILING PANELS. SECURE CONDUIT FIRMLY TO STEEL BY CLIPS AND FITTINGS DESIGNED FOR THAT PURPOSE. INSTALL <br />AS HIGH AS POSSIBLE. BUT NOT LESS THAN 1'-O" ABOVE HUNG CEILINGS. <br />SUPPORT RACEWAYS AT INTERVALS NO GREATER THAN TEN (10) FEET AND WITH ONE SUPPORT WITHIN THREE (3) FEET <br />OF EACH COUPLING, BOX, FITTING, OR OUTLET BOX. PROVIDE ONE SUPPORT WITHIN THREE (3) FEET OF EACH ELBOW <br />OR BEND. <br />OUTLET, JUNCTION, AND PULL BOXES <br />CAST TYPE CONDUIT BOXES, OUTLET BODIES AND FITTINGS <br />1. PROVIDE SURFACE MOUNTED OUTLET AND JUNCTION BOXES, IN INDOOR LOCATIONS, WHERE EXPOSED TO <br />MOISTURE AND IN OUTDOOR LOCATIONS. <br />2. USE FERROUS ALLOY BOXES AND CONDUIT BODIES WITH RIGID STEEL OR IMC. <br />3. COVERS: CAST OR SHEET METAL UNLESS OTHERWISE REQUIRED. <br />4. TAPERED THREADS FOR HUBS. <br />GALVANIZED PRESSED STEEL OUTLET BOXES <br />1. GENERAL <br />a) PRESSED STEEL, GALVANIZED OR CADMIUM -PLATED, MINIMUM OF FOUR (4") INCHES, OCTAGONAL OR <br />SQUARE, WITH GALVANIZED COVER OR EXTENSION RING AS REQUIRED. <br />2. SWITCH AND RECEPTACLE BOX, INDOORS <br />a) NOMINAL FOUR (4") INCH SQUARE, 1-1/2" OR 2-1/8" DEEP AS REQUIRED, WITH RAISED COVER UNLESS <br />OTHERWISE INDICATED ON DRAWINGS. GANGABLE BOXES SHALL NOT BE USED. <br />3. TELEPHONE OUTLET BOX INDOORS <br />a) NOMINAL FOUR (4") INCH SQUARE, 2-1 /8" DEEP, WITH RAISED COVER UNLESS OTHERWISE INDICATED ON <br />DRAWINGS, GANGABLE BOXES SHALL NOT BE USED. <br />4. LIGHTING FIXTURE BOX <br />a) FOUR (4") INCH OCTAGON WITH 3/8" FIXTURE STUD. <br />b) FOR SUSPENDED CEILING WORK, FOUR (4") INCH OCTAGON WITH REMOVABLE BACKPLATE WHERE REQUIRED, <br />AND TWO (2) PARALLEL BARS FOR SECURING TO THE CROSS -FURRING CHANNELS AND EXTEND FLEXIBLE <br />CONDUIT TO EACH FIXTURE. <br />5. PLUG ANY OPEN KNOCKOUTS NOT UTILIZED. <br />BACK-TO-BACK OUTLETS IN THE SAME WALL, OR "THRU-WALL" TYPE BOXES ARE NOT PERMITTED. PROVIDE TWELVE <br />(12") INCHES (MINIMUM) SPACING FOR OUTLETS SHOWN ON OPPOSITE SIDES OF A COMMON WALL TO MINIMIZE SOUND <br />TRANSMISSION. PROVIDE TWENTY FOUR (24") INCH (MINIMUM) HORIZONTAL SPACING FOR OUTLETS SHOWN ON OPPOSITE <br />SIDES OF A FIRE RATED WALL TO MAINTAIN FIRE RATING. <br />ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY, EMT, IMC, RIGID GALVANIZED CONDUIT <br />OR SCHED. 40 P.V.C. THERE SHALL BE NO TYPE NM, MC, ELECTRICAL NON-MATALLIC TUBING, AND FLEXIBLE METAL <br />CONDUIT USED FOR BRANCH CIRCUITING. MAXIMUM NUMBER OF 120V CIRCUITS ALLOWED IN A COMMON CONDUIT SHALL <br />BE SIX (6). THE CONTRACTOR SHALL STRICTLY CONFORM TO THE N.E.C. REQUIREMENTS OF DERATING FOR CONDUCTOR <br />AMPACITY AND CONDUIT FILL. NO CONDUITS SHALL BE INSTALLED EXPOSED ON ROOF. <br />SECTION 16120 <br />WIRE AND CABLE <br />PRODUCTS <br />CONDUCTOR <br />1. ELECTRICAL GRADE ANNEALED COPPER, TINNED IF RUBBER INSULATED, AND FABRICATED IN ACCORDANCE <br />WITH ASTM STANDARDS. MINIMUM SIZE #12 FOR BRANCH CIRCUITS AND #14 FOR CONTROL WIRING. <br />2. THE CONDUCTORS ILLUSTRATED ON THE DRAWINGS ARE COPPER. <br />STRANDING <br />1. #12 AND #10 SOLID. <br />2. CABLES LARGER THAN #10, STRANDED IN ACCORDANCE WITH ASTM CLASS B STRANDING DESIGNATIONS. <br />3. CONTROL WIRES STRANDED IN ACCORDANCE WITH ASTM CLASS B STRANDING DESIGNATIONS <br />INSULATED SINGLE CONDUCTORS <br />1. TYPE THHN/THWN - FLAME RETARDANT: HEAT -RESISTANT THERMOPLASTIC INSULATION. NYLON JACKET <br />RATED FOR 90 C DRY/75C WET OPERATION. USE FOR BRANCH CIRCUIT WIRING. <br />2. USE TYPE THHN/THWN OR RHW OR XHHW, RATED FOR 90 C, FOR FEEDER CIRCUITS. <br />COLOR CODING <br />1. PROVIDE CONSISTENT COLOR CODING OF ALL CIRCUITS AS FOLLOWS: <br />a) 120/208 VOLTS CODE <br />i) PHASE A - BLACK <br />ii) PHASE B - RED <br />iii) PHASE C -BLUE <br />iv) NEUTRAL -WHITE <br />b) 27GROUND GREEN <br />7/480 VOLT CODE <br />i) PHASE A - BROWN <br />ii) PHASE B - ORANGE <br />iii) PHASE C - YELLOW <br />iv) NEUTRAL - WHITE <br />v) GROUND - GREEN <br />2. COLOR -CODE WIRING FOR CONTROL SYSTEMS INSTALLED IN CONJUNCTION WITH MECHANICAL AND/OR <br />MISCELLANEOUS EQUIPMENT IN ACCORDANCE WITH THE WIRING DIAGRAMS FURNISHED WITH THE EQUIPMENT. <br />FACTORY COLOR CODE WIRE NUMBER 6 AND SMALLER. WIRE NUMBER 4 AND LARGER MAY BE COLOR CODED <br />BY COLOR TAPPING OF THE ENTIRE LENGTH OF THE EXPOSED ENDS. <br />CONNECTORS <br />1. MAKE CONNECTIONS, SPLICES, AND TAPS AND JOINTS WITH SOLDERLESS DEVICES, MECHANICALLY AND ELECTRICALLY <br />SECURE. PROTECT EXPOSED WIRES AND CONNECTING DEVICES WITH ELECTRICAL TAPE OR INSULATION TO PROVIDE <br />PROTECTION NOT LESS THAN THAT OF THE CONDUCTOR. <br />2. ELECTRICAL TAPE SHALL BE SPECIFICALLY DESIGNED FOR USE AS INSULATING TAPE. SUPER 33+ SCOTCH VINYL <br />ELECTRICAL TAPE AS MANUFACTURED BY 3M SHALL BE EQUAL. <br />3. USE LUBRICANT WHERE THE POSSIBILITY OF DAMAGE TO CONDUCTORS EXISTS. USE ONLY A LUBRICANT APPROVED <br />BY THE CABLE MANUFACTURER AND ONE WHICH IS COMPATIBLE WITH CABLE AND RACEWAYS. <br />EXECUTION <br />WIRE AND CABLE <br />1. USE #12 AWG MINIMUM FOR BRANCH CIRCUITS WHOSE LENGTH FROM THE PANEL TO FURTHEST OUTLET DOES NOT <br />EXCEED 100 FEET (HORIZONTAL RUN) FOR 120-VOLT CIRCUITS OR 200 FEET FOR 277-VOLT CIRCUITS. USE #10 <br />AWG OR LARGER FOR LONGER RUNS. <br />2. FLASHOVER OR INSULATION VALUE OF JOINTS SHALL BE EQUAL TO THAT OF THE CONDUCTOR. PROVIDE <br />UNDERWRITERS' LABORATORIES LISTED CONNECTORS RATED TO 600 VOLTS FOR GENERAL USE AND 1,000 VOLTS <br />FOR USE BETWEEN BALLASTS AND LAMPS OR GASEOUS DISCHARGE FIXTURES. <br />3. USE TERMINATING FITTINGS, CONNECTORS, ETC., OF A TYPE SUITABLE FOR THE SPECIFIED CABLE FURNIFHED. MAKE <br />BENDS IN CABLE AT TERMINATION PRIOR TO INSTALLING COMPRESSION DEVICE. MAKE FITTINGS TIGHT. <br />4. EXTEND WIRE SIZING FOR THE ENTIRE LENGTH OF A CIRCUIT, FEEDER, ETC. UNLESS SPECIFICALLY NOTED OTHERWISE. <br />GENERAL INSTALLATION <br />1. PROVIDE TOOLS, EQUIPMENT, AND MATERIALS TO PULL ALL WIRE AND CABLE INTO PLACE AND TO MAKE REQUIRED <br />SPLICES AND TERMINATION. <br />2. WIRE AND CABLE IN CONDUIT, DUCT OR WIREWAY <br />a UTILIZE ROLLER BEARING SWIVEL TO PREVENT TWISTING OF CABLE ENTERING CONDUIT OR DUCT. <br />b TAKE PRECAUTIONS TO AVOID ENTRANCE OF DIRT AND WATER INTO CONDUIT AND DUCTS. <br />C CLEAN EXISTING CONDUITS AND DUCTS TO REMOVE ANY PULLING COMPOUND PRIOR TO PULLING NEW CABLES. <br />d DO NOT DAMAGE CONDUCTOR INSULATION, BRAID JACKET OR SHEATH. <br />e DO NOT BEND CONDUCTOR TO LESS THAN MANUFACTURER'S RECOMMENDED RADUIS. <br />f) MAKE SPLICES ONLY IN PULL BOXES, JUNCTION BOXES AND OUTLET BOXES. <br />g) UTILIZE CABLE REELS ON JACKS FOR PULLING THROUGH PULL BOXES, DUCTS AND CONDUITS SO BENDS WILL <br />NOT BE EXCESSIVE AND CONDUCTORS WILL NOT TOUCH SHARP EDGES; USE FEEDING TUBE WHERE REQUIRED. <br />h) FOR LARGE DIAMETER CABLES, UTILIZE PROPERLY SIZED PULLING GRIPS. <br />i) DO NOT EXCEED MAXIMUM RECOMMENDED PULLING TENSION OF WIRE AND CABLE. <br />FIELD QUALITY CONTROL <br />1. TEST SYSTEM WIRING FOR CONTINUITY, GROUNDS AND SHORT CIRCUITS PRIOR TO CONNECTION OF ANY EQUIPMENT. <br />2. TEST FINAL EQUIPMENT CONNECTIONS FOR CONTINUITY OF GROUNDS AND SHORT CIRCUITS. <br />3. INSULATION RESISTANCE OF FEEDERS AND SUBFEEDERS. <br />a) TEST WITH MEGGER FOR INSULATION RESISTANCE. <br />b) CORRECT FAULTS AND REPLACE SECTIONS WITH FAULTY INSULATION. <br />c) DEMONSTRATE INSTALLATION IS FREE OF GROUNDS AND SHORT CIRCUITS AND THAT INSULATION RESISTANCE <br />COMPLIES WITH ICEA VALUES <br />4. TEST DIRECT BURIAL CABLES AFTER COMPLE11ON OF BACKFILLING. <br />SECTION 16140 <br />WIRING DEVICES <br />EXECUTION <br />SWITCHES <br />1. PROVIDE SPECIFICATION GRADE, FLUSH MOUNTING, QUIET -OPERATING AC TYPE, WITH TOGGLE OPERATOR, HEAT -RESISTANT <br />PLASTIC HOUSING AND SELF GROUNDING METAL STRAP. SILVER OR SILVER ALLOY CONTACT. DESIGN FOR SIDE OR BACK <br />WIRING WITH UP TO NUMBER 10 WIRE. VERIFIED BY UL TO MEET OR EXCEED FEDERAL SPECIFICATION WS-896E. USE <br />SINGLE -POLE, DOUBLE -POLE, 3-WAY, 4-WAY, LIGHTED, PILOT OR KEYED TYPE, AS INDICATED ON DRAWINGS OR REQUIRED. <br />PROVIDE IVORY COLOR UNLESS OTHERWISE NOTED. <br />2. WHERE SWITCHES ARE INDICATED TO BE INSTALLED NEAR DOORS, CORNER WALLS, ETC. MOUNT SAME NOT LESS THAN 2" <br />AND NOT MORE THAN 18" FROM TRIM. VERIFY EXACT LOCATION WITH THE ARCHITECT. <br />3. CAREFULLY COORDINATE THE LOCATION OF SWITCHES TO INSURE LOCATIONS AT THE STRIKE SIDE OF DOORS. <br />4. FURNISH AND INSTALL AN ENGRAVED LEGEND FOR EACH SWITCH THAT CONTROLS EXHAUST FANS, MOTORS, EQUIPMENT <br />SYSTEMS, ETC., NOT LOCATED WITHIN SIGHT OF THE CONTROLLING SWITCH. <br />RECEPTACLES <br />1. UNLESS OTHERWISE NOTED, MOUNT RECEPTACLE VERTICALLY WITH U-SHAPED GROUND POSITION ON BOTTOM. <br />ALL GENERAL PURPOSE SWITCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE <br />MANUFACTURER. CATALOG NUMBERS LISTED ARE LEVITON: HOWEVER, COMPARABLE DEVICES BY <br />PASS & SEYMOUR, BRYANT, OR ARROW HART WILL BE ACCEPTED. COLOR OF DEVICES AND <br />PLATES SHALL BE DICTATED BY ARCHITECT/OWNER. <br />A. SWITCHES: LEVITON #CSB1-201 <br />B. RECEPTACLES: LEVITON #BR20-1 <br />C. COVER PLATES: SMOOTH PLASTIC <br />NOTE: ALL OTHER REQUIRED DEVICES SHALL MATCH IN COLOR AND STYLE. <br />GROUND FAULT INTERRUPTERS <br />1. SWAB ALL CONDUITS CLEAR OF MOISTURE <br />2. DO NOT COMBINE G.F.I. PROTECTED CIRCUITS WITH OTHER CIRCUITS IN SAME RACEWAY. <br />3. LIMIT MAXIMUM NUMBER OF G.F.I. PROTECTED CIRCUITS IN ANY ONE RACEWAY TO A MAXIMUM OF ONE CIRCUIT. <br />4. GFCI DEVICES SHALL BE ARRANGED TO BE EASILY LOCATED <br />a) LABEL DOWNSTREAM RECEPTACLES TO INDICATE THE GFCI LOCATION WHERE RECEPTACLES ARE MORE THAN 20' FROM <br />THE GFCI DEVICE. <br />b) GFCI DEVICES LOCATED IN RESTROOMS SHALL N.-T FEED THROUGH TO PROTECT DEVICES IN OTHER ROOMS. <br />SECTION 16195 <br />ELECTRICAL IDENTIFICATION <br />PRODUCTS <br />NAMEPLATES <br />1. UNLESS OTHERWISE NOTED, NAMEPLATES SHALL BE BLACK LAMACOID PLATES WITH WHITE ENGRAVED UPPER CASE <br />LETTERS ENCLOSED BY WHITE BORDER ON BEVELED EDGES. <br />2. NAMEPLATES FOR EQUIPMENT, SUPPLIED BY THE EMERGENCY SYSTEM, SHALL BE RED LAMACOID WITH WHITE <br />LETTERING. <br />3. ALL NAMEPLATES SHALL BE ENGRAVED AND MUST BE SECURED WITH RIVETS, BRASS OR CADMIUM PLATE SCREWS. <br />THE USE OF DYMO TAPE OR THE LIKE IS UNACCEPTABLE. <br />CABLE TAGS AND WIRE IDENTIFICATION LABELS <br />1. CABLE TAGS SHALL BE FLAMEPROOF SECURED WITH NYLON TIES. <br />2. WIRE MARKERS SHALL BE PREPRINGTED CLOTH TAPE TYPE OR APPROVED EQUIVALENT. <br />3. LABEL DESIGNATIONS, NOMINAL SYSTEM VOLTAGES APPLIED TO THE COVERS OF ALL MEDIUM AND LOW VOLTAGE <br />PULL, SPLICE AND JUNCTION BOXES. <br />EXECUTION <br />SWITCHBOARDS. <br />1. FURNISH AND INSTALL A MASTER NAMEPLATE FOR EACH SWITCHBOARD, ENGRAVED WITH THE EQUIPMENT IDENTIFICATION <br />INDICATED ON THE DRAWINGS. MOUNT AT TOP OF INCOMING SECTION. <br />2. PROVIDE ON EACH MAIN SWITCH AN IDENTIFYING NAMEPLATE. <br />PANELBOARDS <br />1. FURNISH AND INSTALL A NAMEPLATE FOR EACH PANELBOARD AND LOAD CENTER ENGRAVED WITH THE IDENTIFICATION <br />INDICA T EED ON THE DRAWINGS. MOUNT AT TOP OF PANEL. <br />DISCONNECT SWITCHES <br />1. FURNISH AND INSTALL A NAMEPLATE FOR EACH DISCONNECT SWITCH ENGRAVED WITH EQUIPMENT DESIGNATION WHICH <br />THE DISCONNECT SERVES. <br />SECTION 16431 <br />SWITCHBOARDS <br />PRODUCTS <br />APPROVED MANUFACTURERS <br />1. ALL SWITCHBOARDS ARE TO BE OF THE SAME MANUFACTURER AS THE PANELBOARDS <br />2. SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING MANUFACTURERS: <br />a) SQUARED <br />b CUTLER -HAMMER <br />c GENERAL ELECTRIC <br />d SIEMENS ITE <br />RATINGS <br />1. THE ASSEMBLY SHALL BE RATED TO WITHSTAND MECHANICAL FORCES EXERTED DURING SHORT CIRCUIT CONDITIONS <br />WHEN CONNECTED DIRECTLY TO A POWER SOURCE HAVING AVAILABLE FAULT CURRENT AS SHOWN ON THE DRAWINGS. <br />ENCLOSURES <br />1. PROVIDE NEMA 1 ENCLOSURES WHERE LOCATED INDOORS IN DRY LOCATIONS. <br />2. PROVICE NEMA 3R ENCLOSURES WHERE LOCATED OUTDOORS AND CT LOCATIONS SU J SUBJECT TO THE ELEMENTS. <br />FINISH <br />1. ALL EXTERIOR AND INTERIOR STEEL SURFACES OF THE SWITCHBOARD SHALL BE PROPERLY CLEANED AND PROVIDED <br />WITH A RUST -INHIBITING PHOSPHATIZED COATING. COLOR AND FINISH OF INDOOR SWITCHBOARDS SHALL BE ANSI 61 <br />LIGHT GRAY. <br />2. OUTDOOR SWITCHBOARD SHALL BE PAINTED TO MATCH THE BUILDING. <br />SECTION 16450 <br />GROUNDING <br />SUBMITTALS <br />1. SUBMIT TEST REPORTS CERTIFYING RESISTANCE VALUES FOR BURIED OR DRIVEN GROUNDS AND WATER PIPE GROUNDS. <br />PRODUCTS <br />MATERIALS <br />1. GROUND CABLES: GREEN COLOR CODED, INSULATED, ANNEALED STRANDED TINNED COPPER WIRE AS INDICATED ON <br />DRAWINGS. <br />2. GROUND RODS: <br />a COPPER -CLAD STEEL FABRICATED BY MOLTEN WELDING PROCESS. <br />b DIAMETER: 5/8 INCH. USE 3/4 INCH FOR ROCKY SOIL. <br />c) LENGTH: 10 FEET. <br />GENERAL <br />1. ALL GROUND WIRES AND BONDING JUMPERS SHALL BE STRANDED COPPER INSTALLED IN CONDUIT. ALL GROUND WIRES <br />SHALL BE WITHOUT JOINTS AND SPLICES OVER ITS ENTIRE LENGTH. <br />2. THE SYSTEM NEUTRAL SHALL BE GROUNDED AT THE SERVICE ENTRANCE ONLY, AND KEPT ISOLATED FOR <br />GROUNDING SYSTEMS THROUGHOUT THE BUILDING. <br />3. EACH SYSTEM OF CONTINUOUS METALLIC PIPING AND DUCTWORK SHALL BE GROUNDED IN ACCORDANCE WITH THE <br />REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. <br />4. MECHANICAL EQUIPMENT SHALL BE BONDED TO THE BUILDING DQUIPMENT GROUNDING SYSTEM. THIS SHALL INCLUDE <br />BUT IS NOT LIMITED TO, FANS, PUMPS, CHILLERS, ETC. <br />5. PVC CONDUITS AND PORTIONS OF METALLIC <br />LL C PIPING AND DUCT SYSTEMS WHICH ARE ISOLATED BY FLEXIBLE CONNECTIONS, <br />INSULATED COUPLINGS, ETC., SHALL BE BONDED TO THE EQUIPMENT GROUND WITH A FLEXIBLE BONDING JUMPER, OR <br />SEPARATE GROUNDING CONDUCTOR. <br />SEPARATELY DERIVED SYSTEMS <br />1. EQUIPMENT GROUNDINNG CONDUCTORS SHALL BE PROVIDED FOR SEPARATELY DERIVED SYSTEMS AND SHALL BE <br />GROUNDED TO BUILDING S ft-L- , , COLD WATER PIPES, ETC., OR AN ALTERNATE GROUNDING MEANS. <br />2. A SEPARATE, GREEN TYPE THW COr�t=a GROUND CONDUCTOR SHALL BE RUN FROM GROUND LUG OF EACH GROUNDED <br />RECEPTACLE TO AN APPROVED CONNECTION i THE ENCLOSING STEEL OUTLET BOX. DEVICE MOUNTING SCREWS <br />SHALL NOT BE CONSIDERED AN APPROVED GROUND. <br />3. A SEPARATE GROUND CONDUCTOR SHALL BE INSTALLED IN EVERY i;C;MnIIIT AND RACEWAY AND SECURELY BONDED <br />IN AS APPROVED GROUNDING TERMINAL AT BOTH ENDS OF THE RUN. THE Gkc utDING CONDUCTOR SHALL BE SIZED <br />IN ACCORDANCE WITH TABLE 250 OF THE N.E.C.. CONTRACTOR SHALL SIZE CONDUI TO ACCOMMODATE ADDITIONAL <br />CONDUCTOR. <br />ISOLATED GROUND RECEPTACLES <br />1. ISOLATED GROUND RECEPTACLES GROUND LUG SHALL NOT BE CONNECTED TO THE RESPECTIVE OUTLET BOXES. <br />2. PROVIDE INSULATED GROUND WIRE FOR EACH ISOLATED `GROUND RECEPTACLE. GROUND WIRE SHALL SERVE ONLY THOSE <br />RECEPTACLES WHICH ARE ISOLATED. ROUTE GROUND CONDUCTOR TOGETHER WITH PHASE AND NEUTRAL CONDUCTORS <br />IN A COMMON RACEWAY. <br />3. TERMINATE ISOLATED GROUND WIRE AT THE GROUND FROM THE SEPARATELY DERIVED SYSTEM SERVING THE RECEPTACLES. <br />GROUND CONDUCTORS <br />1. SIZE AS SHOWN ON DRAWINGS OR AS REQUIRED BY NATIONAL ELECTRICAL CODE. <br />PANELBOARDS <br />GENERAL <br />1. ALL SWITCHGEAR, PANELS, STARTERS, CONTACTORS ETC., SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER, THE <br />SYSTEM DESIGN IS BASED ON SQUARE "D"; HOWEVER, COMPARABLE EQUIPMENT BY G.E., & SEIMENS ONLY WILL BE <br />ACCEPTABLE ALTERNATES. TANDEM AND HALF -SPACE CIRCUIT BREAKERS SHALL NOT BE USED. <br />2. ALL ELECTRICAL PANELS INDICATED ON THESE DRAWINGS ARE DESIGNED AND SERIES RATED, AS PER SQUARE "D" <br />SPECIFICATIONS. IF AN ALTERNATE MANUFACTURER IS SUBSTITUTED, IT 1S THE RESPONSIBILITY OF THE ELECTRICAL <br />CONTRACTOR TO PROPERLY SERIES RATE ALL PANELS. <br />3. TYPEWRITTEN CIRCUIT INDEX SHALL BE AFFIXED TO INSIDE SURFACE OF EACH PANELBOARD DOOR, CLEARLY INDICATING <br />AREA AND TYPE OF LOAD SERVED BY EACH BRANCH CIRCUIT PROTECTIVE DEVICE, INCLUDING SPARES. HAND PRINTED <br />WILL NOT BE ACCEPTED. <br />4. ENGRAVED, LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED ON ALL PANELS AND <br />SWITCHGEAR. PLATES SHALL BE AFFIXED TO FRONT OF PANELS, INDICATING PANEL NAME, VOLTAGE AND AMPERAGE. <br />ID►;i*11ii me h, <br />INSTALLATION <br />1. MOUNT ALL PANELS AT A MAXIMUM HEIGHT OF 6 FEET 6 INCHES TO TOP UNLESS OTHERWISE NOTED. <br />2. WHERE FLUSHED MOUNTED, THE FIRE INTEGRITY OF THE WALL IN WHICH IT IS INSTALLED MUST BE MAINTAINED. <br />3. NEATLY ARRANGE BRANCH CIRCUIT WIRES AND TIE TOGETHER IN EACH GUTTER WITH THOMAS & BETTS NYLON <br />"TY-RAPS", OR APPROVED EQUAL AT MINIMUM 4 INCH INTERVALS. <br />4. PLUG ALL KNOCKOUTS REMOVED AND NOT UTILIZED. <br />5. PROVIDE NAMEPLATE AND FILL OUT PANEL DIRECTORY. FOR REMODAL WORK OR CHANGES, TRACE CIRCUITS . <br />CETERMINE LOADS AND PROVIDE NEW UPDATED DIRECTORY. <br />TOUCH UP AND CLEANING <br />1. VACUUM ALL BACKBOXES CLEAN OF DEBRIS AFTER INSTALLATION AND PRIOR TO CONTRACT CM .jIJT. <br />2. TOUCH UP SCRATCH MARKS, ETC. WITH MATCHING PAINT. <br />SECTION 16500 <br />LUMINAIRES AND ACCESSORIES <br />PRODUCTS <br />LUPINAIRES <br />1. ACCEPTABLE MANUFAC FOREERS ARE iED IN 1, LIGHTING FIXTURE SCHEDULE SHOWN ON THE DRAWINGS. <br />2. THE DESIGNATIONS INDICATED ON THE LIGn n .0 FsY TURE SCHEDULE ARE A DESIGN SERIES EFFR��!^E O i NECESSARILY A COMPLCrt <br />CATALOG NUMBER) AND DO NOT NECESSARILY REPRESENT THE NUMBER, SITE, VOLTAGE, WATTAGE, TYPE OF LAMP, BALLAST, FINISH <br />TRIM, CEILING TYPE, MOUNTING HARDWARE OF SPECIAL REQUIREMENTS AS SPECIFIED HEREINAFTER ON AS REQUIRED BY THE PARTICULAR <br />INSTALLATION(S) AND CODE. CONTRACTOR SHALL VERIFY THESE REQUIREMENTS AND OTHER FIXTURES AS REQUIRED TO GIVE PROPER <br />INSTALLATION PER THE CONTRACT DOCUMENTS AND PER CODES. <br />BALLASTS <br />1. IT IS PREFERRED THAT ALL BALLASTS SHALL BE OF THE SAME MANUFACTURER. EVERY EFFORT SHALL BE MADE TO ELIMINATE BALLASTS <br />FROM MULTIPLE MANUFATURERS. BALLASTS WITHIN LUMINAIRES OF A GIVEN TYPE MUST HOWEVER BE OF THE SAME MANUFACTURER. <br />MULTIPLE MANUFACTURERS WILL NOT BE PERMITTED. <br />2. APPROVED MANUFACTURERS. <br />a) GENERAL ELECTRIC <br />b) MOTOROLA <br />c) MAGNETEK <br />FABRICATION <br />1. PROVIDE LUMINAIRES, COMPLETE FACTORY -ASSEMBLED AND WIRED AND EQUIPPED WITH NECESSARY SOCKETS, BALLASTS, WIRING, REFLECTORS, <br />CHANNELS, LENSES, ETC., AND DELIVER TO JOB READY FOR INSTALLATION. <br />MATERIALS <br />1. PROVIDE BALLASTS WITH VOLTAGE CHARACTERISTICS TO MATCH THAT OF ALL RELATED CIRCUITRY INDICATED ON DRAWINGS. NO EXTRA <br />COMPENSATION WILL BE ALLOWED FOR FAILURE TO PROPERLY COORDINATE BALLAST VOLTAGE WITH CIRCUITRY. <br />2. BALLASTS FOR CONTROL OF LAMPS IN ONE HOUSING OR FIXTURE UNIT SHALL NOT CONTROL LAMPS OF AN ADJOINING UNIT. <br />3. GUARANTEE BALLAST FOR ONE FULL YEAR AND ONE YEAR PRORATED AS PER STANDARD MANUFACTURER'S WARRANTY AGAINST DEFECTS <br />FOR A PERIOD OF 2 YEARS. GUARANTEE TO INCLUDE REPLACING DEFECTIVE BALLAST WITH NEW BALLAST. <br />LAMPS <br />1. PROVIDE A COMPLETE SET OF NEW LAMPS IN EACH FIXTURE. <br />2. UNLESS NOTED OTHERWISE LAMPS MUST CONFORM TO THE FOLLOWING: <br />a) FLUORESCENT: T-8, 35K COLOR. <br />b) INCANDESCENT: "A" LAMPS TO BE INSIDE FROSTED RATED AT 130 VOLTS. <br />c) LOW VOLTAGE: MR-16. <br />EXECUTION <br />INSTALLATION <br />1. INSTALL LUMINAIRES IN MECHANICAL AND UNFIN. '-77ER DUCTWORK AND PIP`"),I!.ATION. ADJUST RYTI F <br />TO PROVIDE THE BEST LIGHTING FOR EQUIPMEN - VICE LOCATIONS. I = --T 6 l_OOR, <br />OR AT SUITABLE LOCATIONS WITHIN SPACE ON WALL) BUT N01 NFR THE*' 7'-n" <br />2. THE CONTRACTOR SHALL PROTECT LUMINAIRES FROM DAMAGE DURII JN OF SAME AND _ . OF ACCEPTANCE. <br />ANY BROKEN LUMINAIRES, GLASSWARE, PLASTICS, LAMPS ETC., MUST BE REPLA�.ED BY THE CONTRACTOR WITH NEW PARTS, WITHOUT <br />ANY ADDITIONAL EXPENSE TO THE OWNER. <br />3. WHERE BALLASTS ARE FOUND TO BE PRODUCING EXCESSIVE NOISE THEY SHALL BE REPLACED. <br />4. INSTALL EXIT LIGHT AS INDICATED ON THE DRAWINGS BUT NOT HIGHER THAN 10 FEET A.F.F. SIZE AND COLOR OF LETTERING SHALL COMPLY <br />WITH LOCAL CODES. <br />5. TRACK LUMINAIRES, ADJUSTABLE LUMINAIRES, FLOODLIGHTS AND ACCENT LIGHTS SHALL BE AIMED AS DIRECTED BY THE ARCHITECT/ENGINEER. <br />OUTDOOR LIGHTING SHALL BE AIMED IN PERIODS OF DARKNESS. <br />6. PLUMB ALL OUTDOOR LIGHTING STANDARDS TO TRUE VERTICAL. FOR BOLTED POLES, PROVIDE GALVANIZED ANCHOR BOLTS AND NUTS. PLUMB <br />USING A NUT ABOVE AND BELOW THE BASE PLATE ON THE ANCHOR BOLTS. PACK GROUT BETWEEN BASE PLATE AND CONCRETE FOOTING <br />AND PROVIDE DRAIN HOLE BELOW BASE PLATE TO PREVENT ACCUMULATION OF MOISTURE INSIDE POLE BASE. PROVIDE TWO PIECE OR <br />INDIVIDUAL COVERS FOR NUTS EXPOSED ABOVE THE BASEPLATE OF THE SAME COLOR AS THE POLE. GROUND ALL METAL LIGHTING STANDARDS. <br />SECTION 16475 <br />FUSES 600V AND LESS <br />GENERAL <br />1. ALL FUSES FOR SAFETY SWITCHES SHALL BE FUSES SHALL BE THOSE MANUFACTUI' <br />EITHER BUSSMAN OR LITTLEFUSE. THE CONT� FUSE FOR EACH <br />TYPE OF FUSE INSTALLED. FUSES 600 AMPS -m LESS JIIALL CLASS ,�uISE i <br />OVER 600 AMPS SHALL BE CLASS "L". <br />INSTALLATION <br />1. FUSES SHALL NOT BE INSTALLED UNTIL EQUIPMENT IS READY TO BE ENERGIZED. <br />2. PROVIDE AND INSTALL FUSES OF PROPER TYPE, VOLTAGE AND AMPERE RATINGS FOR ALL FUSIBLE DEVICES FURNISHED. <br />3. LABELS <br />a) APPLY APPROPRIATE LABEL WITHIN EACH SWITCH, 11,10-,.. ^ 41PTER, OR PANEL BOARD DOOR OR AT LOCATION NEXT <br />TO FUSE CLIPS, WHERE F'!` r '?Y THIS CONTRACTOR. FILL-IN IN INK BLANK SPACES <br />ON LABELS FOR NON-S <br />SECTION 16476 <br />DISCONNECT SWITCHES <br />GENERAL <br />1. DISCONNECT SWITCHES SHALL BE H.P. RATED GENERAL DUTY QUICK -MAKE, QUICK -BREAK <br />TYPE ENCLOSURES SHALL BE AS REQUIRED <br />BY N.E.C. AND LOCATION (WEATHERPROOF, EXPLOSIONS PROOF, ETC.) ENGRAVED LAMINATE <br />D PLASTIC IDENTIFICATION PLATES SHALL <br />BE FURNISHED AND INSTALLED ON ALL DISCONNECT SWITCHES, CONTACTORS AND STARTERS. <br />> <br />t <br />P. <br />8 <br />a <br />8' <br />; <br />J <br />(14 <br />� � <br />N '" <br />o <br />S <br />a) P-4 -0 <br />Q'�, CIO w <br />N U <br />0 Y <br />• 0rr� <br />0 V <br />w r. <br />• PI o <br />U i w <br />jai <br />ct U <br />U <br />u64 <br />9 9 <br />^ ♦� <br />W <br />C <br />0 <br />a <br />0 <br />" <br />(/ W 11 <br />�Zco <br />�CD <br />VQM <br />U c+M <br />� Q J <br />�0LL <br />ILL! E¢Q <br />z ." 0) <br />w a- M H <br />J <br />U <br />L_ <br />E <br />0 <br />U <br />L <br />01 <br />0 LL <br />N o <br />(u m <br />iiiii Y <br />u- Q <br />ULm <br />r J <br />U- <br />0 <br />U) N <br />Na) <br />00 <br />U ti <br />cu06J <br />LL . r <br />�0^-I <br />VJ�J <br />J_ <br />��2 <br />jft <br />cu1,>_ <br />�_ <br />cO= <br />O�W <br />LU <br />0 <br />�"_' I- N <br />CL <br />N � <br />M p <br />a •-" <br />F. o) <br />b� <br />g p <br />0 `t <br />0-w <br />9 ' <br />�,-o <br />0 <br />U � <br />.2,G, R <br />O � <br />N - <br />�a 3 <br />■l0 <br />U) <br />Q�. ;, <br />l' <br />0 <br />^0, <br />W <br />r' <br />cu <br />L <br />U <br />L_ 0 <br />H <br />w w <br />w <br />= <br />U) <br />ems.. a <br />.,._ <br />= <br />Q <br />,It.� <br />® <br />z <br />N <br />N <br />k. <br />r-i <br />F- J <br />O w <br />� <br />I <br />c:)"44%iiiiiiiiiiiiiiiii� <br />2__ <br />E35 <br />cn <br />H <br />m <br />IY <br />w <br />i <br />0 <br />fM <br />O_ <br />w <br />mI <br />o <br />Q <br />u] <br />o <br />N <br />J <br />W <br />0 <br />a <br />an <br />"'I <br />d <br />o <br />Z <br />m <br />I <br />oW <br />U <br />o <br />o <br />Zs <br />Y <br />z <br />15, <br />N <br />N <br />Q <br />0 <br />U, <br />S <br />W <br />U <br />a <br />p <br />� <br />4 <br />I_v_ __T___T_._r(1r11, II ��� IfR i I - - <br />-r- T Ili ,1„ , I ,.. - � i � i�-_IT -,. i - - T__. _.__ - 7TfI' i - is ii ,': r s <br />TENANT BUILD OUT <br />E501 <br />