Laserfiche WebLink
EXISTING RAIN - <br />HOODS OVER <br />REAR DOORS <br />TO REMAIN AS IS <br />Interior Elevation <br />SCALEA.T.S. <br />REF: <br />EXISTING SCONCE NEW RAIN HOOD <br />LIGHT FIXTURE OVER NEW DOOR. <br />TO BE REWIRED. RE: DOOR SCHEDULE <br />RE: E101 <br />® EX <br />EM <br />EX <br />7EXISTING CMU, SAW CUT JAMBS AS SHOWN <br />FOR ADDITION OF VERT. REINF. AND GROUT <br />EXISTING CMU, SHOWN WITH ADDED <br />REINF. (CENTER SPACING) AND GROUT <br />2 Masonry Vert. Reinforcing <br />SCALEATS. <br />REF: <br />ALL EXISTING REBAR OUTSIDE OF THE NEW 6-4" X 7'-4" <br />CMU OPENING SHALL REMAIN UNDAMAGED. ALL DEMO <br />WORKAT THE JAMBS AND HEAD OF THE NEW OPENING <br />SHALL BE PERFORMED CAREFULLY AND SURGICALLY <br />SO AS NOT TO DAMAGE ANY OF THE EXISTING REBAR. <br />1'-0' MIN. EXISTING CMU AND SLAB SECTION <br />TO BE REMOVED, GC TO MINIMIZE <br />EXTENTS OF SLAB SECTION REMOVED <br />GC V.I.F. ALL CELLS GROUTED <br />SOLID BELOW FIN. FLR. <br />EXISTING FOOTING TO REMAIN <br />CEILING CEILING PLAN GENERAL NOTES: <br />1. ALL NEW CEILINGS SHALL BE 2' X 4' ACT MOUNTED <br />AT 10'-0"AFF WITH NO INSULATION. <br />2. ON THE FRONT OF THE BUILDING, THE EXISTING <br />DECORATIVE SCONCE FIXTURES SHALL REMAIN WIRED <br />AS IS TO THE EXISTING HOUSE PANEL. <br />3. EXISTING REAR WALL MOUNTED LIGHTS SHALL BE WIRED <br />TO THE NEW TENANT PANELS VIA NEW LIGHT SWITCHES. <br />4. THE EXISTING EXIT AND EMERGENCY LIGHTS SHALL BE <br />NEW 2' X 4' ACOUSTICAL TILE REUSED IF POSSIBLE. THEY SHALL BE RE -WIRED FROM <br />THE HOUSE PANEL TO THE NEW TENANT PANELS. <br />CEILINGS MOUNTED AT 1U-0" <br />ABOVE FLOORS IN SPACE F1-F3 IN RESTROOMS ONLY 5. ALL NEW LIGHTS SHALL BE WIRED TO THE NEW PANELS. <br />V.I.F. <br />Slab @ New Opening, Demo <br />SCALEATS. <br />REF: <br />­ <br />tM� <br />EM <br />EXISTING RAIN <br />HOODS OVER <br />REAR DOORS <br />TO REMAIN AS IS <br />EXISTING LIGHTS IN _ _ EXISTING SCONCE EXISTING RAIN EXISTING SCONCE <br />FIRE RISER ROOM � LIGHT FIXTURE HOODS OVER LIGHT FIXTURE <br />TO BE REWIRED. REAR DOORS TO BE REWIRED. <br />TO REMAIN AS IS. RE: E101 TO REMAIN AS IS RE: E101 <br />EM EM <br />NEW HVAC RETURN AIR <br />GRILLE MOUNTED <br />IN CEILING. RE: M101 <br />—� <br />EM EM <br />117 <br />EM ® ® ® EM <br />EMERGENCY LIGHT FIXTURE (EM). <br />WIRED TO NEW TENANT PANEL. <br />REUSE EXISTING IF POSSIBLE. RE: E201 <br />--_ - - _ (1) EX <br />EXISTING CANOPY <br />(I <br />LIGHT FIXTURE <br />TO REMAIN AS IS <br />�❑ <br />EXISTING SOLID <br />FABRIC AWNING <br />STRIPED FABRIC AWNING <br />TO BE REPLACED WITH <br />TO REMAIN AS IS <br />SOLID FABRIC TO MATCH <br />ADJACENT. AWNING <br />EXISTING CANOPY <br />FRAME TO REMAIN AS IS. <br />_ = <br />ACCESS HATCH <br />TO REMAIN AS IS <br />EXISTING SCONCE = <br />= <br />EXISTING SCONCE <br />LIGHT FIXTURE <br />LIGHT FIXTURE <br />TO REMAIN AS IS <br />_ <br />TO REMAIN AS IS <br />4 <br />eN <br />Reflected <br />Ceiling <br />Plan <br />SCALE: 1/8" = V-0" <br />STRIPED FABRIC AWNING <br />TO BE REPLACED WITH <br />EXISTING SOLID <br />FABRICAWNING <br />SOLID FABRIC TO MATCH <br />TO REMAIN AS IS <br />ADJACENT. AWNING <br />FRAME TO REMAIN AS IS. <br />EXISTING SCONCE <br />LIGHT FIXTURE <br />TO REMAIN AS IS <br />NEW EXHAUST FANS <br />IN RESTROOM <br />CEILINGS. RE: M101 <br />NEW 2 X 4 CEILING <br />MOUNTED LIGHT <br />FIXTURES. RE: E101 <br />NEW HVAC SUPPLY AIR <br />DIFFUSER MOUNTED <br />IN CEILING. RE: M101 <br />NEW 2' X 4' ACOUSTICAL TILE <br />CEILINGS MOUNTED AT 10'-0" <br />ABOVE FLOORS IN RESTROOMS <br />AND IN MAIN ROOM OF F4 <br />EX IeY Y" <br />NEW EXIT LIGHT EXISTING SCONCE <br />FIXTURE (EX) WIRED TO NEW LIGHT FIXTURE <br />TENANT PANEL. REUSE EXISTING TO REMAIN AS IS <br />IF POSSIBLE. RE: E201 <br />Door Schedule <br />DOOR <br />FRAME <br />HARD <br />WARE <br />TYPE <br /># <br />MATERIAL <br />SIZE (EACH) <br />MATERIAL <br />DETAILS <br />SET <br />A <br />DBL <br />HM <br />T-0" X T-0" <br />HM <br />H1, J1, S1 <br />1 <br />X 1 3/4" <br />B <br />SGL <br />ALUM. <br />3'-0" X 7' 0" <br />ALUM. <br />H2, J2, S2 <br />2 <br />X 1 3/4" <br />C <br />DBL <br />ALUM. <br />3'-0" X 7'-0" <br />ALUM. <br />H2, J2, S2 <br />3 <br />X 1 3/4" <br />D <br />SGL <br />WOOD <br />3-0"X/4" <br />WOOD <br />H3, J3, S3 <br />4 <br />X 1 3/4" <br />E <br />DBL <br />ABS <br />3'-0' X 8'-0" <br />ABS <br />J4 <br />5 <br />X 1 3/4" <br />NOTES: <br />1. PAINT EXTR. OF DOOR "A" TO MATCH EXISTING. LEAVE INTR. PAINT READY. <br />2. PAINT INTR. OF DOOR'D' TO MATCH RESTROOM WALLS. EXTR. SHALL <br />BE <br />PAINT READY. PROVIDE REINFORCED PANEL TO ACCEPT CLOSER. <br />3. DOOR "E" IS A DOUBLE ACTING IMPACT TRAFFICE DOOR <br />(RUBBAIR ULTRA-LITE WITH WINDOWS). <br />NOA Schedule <br />BUILDING <br />MANUFACTURER <br />NOA# <br />EXPIRATION <br />MATERIAL <br />/ MODEL # <br />DATE <br />STOREFRONT <br />YKK-AP <br />08 0715.14 <br />08-07-13 <br />WINDOWS <br />YES 45 FS <br />STOREFRONT <br />YKK-AP <br />07-0403.08 <br />04-16-12 <br />DOORS <br />35D, MEDIUM STILE <br />HOLLOW METAL <br />CECO <br />09-0505.09 <br />08-05-14 <br />REAR DOORS <br />6-0 X 7-0 SWINGING DOOR <br />NOTES: <br />1. THESE NOA'S ARE PROVIDED TO COMPLY WITH THE FLORIDA BUILDING <br />COMMISSION RULE 9B-72. THESE APPROVALS HAVE BEEN REVIEWED FOR <br />APPLICATION ON THIS PROJECT. THE ARCHITECT'S SIGNATURE AND SEAL <br />DOES NOT REPLACE OR SUPERCEDE THE PROFESSIONAL RESPONSIBILITY <br />OF THE INDIVIDUAL NOA'S OR INTERNAL DESIGN COMPONENTS THEREOF. <br />2. THE CONTRACTOR MAY SUBMIT ALTERNATES FOR ANY OF THE BUILDING <br />COMPONENTS ON THIS LISTAS LONGAS IT DOES NOTVIOLATEANY <br />EXISTING WARRANTIES THAT MAY BE IN EFFECT. IN ORDER TO RECEIVE <br />APPROVAL ON ANYALTERNATES, THE GC MUST SUBMIT PRODUCT <br />INFORMATION TO THE OWNER FOR REVIEW AS WELL AS TO THE LOCAL <br />JURISDICTION AS REQUIRED FOR PERMITTING AND C.O. <br />3. THE MAXIMUM DESIGN PRESSURE THAT THESE COMPONENTS NEED TO <br />WITHSTAND IS + / - 36.1 PSF. IMPACT RESISTANCE IS NOT REQUIRED. <br />All <br />HEAD DETAIL - H1 <br />WCUT CMU, <br />INT IN RAIN <br />OD, CAULK <br />NT <br />GA. GALV. <br />L. RAINHOOD, <br />NT TO <br />TCH DOORS. <br />OD TO <br />FEND 8" <br />3T EDGE <br />DOOR ON <br />TH SIDES <br />DOOR <br />THEIR <br />P <br />GROUT SOLID <br />FULL DOOR <br />WEATHER STRIP <br />MASONRYJAMB <br />ANCHOR AS REQ. <br />CAULK PERIMETER <br />CONT TYP <br />JAMB DETAIL - J 1 <br />DOORFRAME <br />'OND) <br />THRESHOLD <br />V MASTIC (TYR) <br />3H FLOOR <br />--LOOR PLAN <br />SILL DETAIL - S1 <br />COORDINATE ALL EXTERIOR DOOR DETAILS <br />5 Door Details WITH THE REQUIREMENTS OF THE ASSOCIATED <br />SCALE: 3" = VI FLORIDA PRODUCT APPROVAL (NOA) <br />Hardware Schedule <br />HARDWARE SET # 1: (REAR HOLLOW METAL DOOR) <br />(6) - HAGER 4-1/2" X 4-1/2" BUTT FULL MORTISE <br />HINGES NO. BB1191 (NRP). STAINLESS <br />STEEL HINGES W/ STAINLESS STEEL PINS <br />(1) - LOCKSET SCHLAGE AL53PD "ENTRANCE <br />LOCK". FINISH 626 (US 26D) SATIN CHROME <br />(1) - CLOSER - LCN NO.4040. STANDARD POWDER <br />COATALUMINUM FINISH. STANDARD PLASTIC <br />COVER. MOUNTED ON INTERIOR SIDE <br />(1) - SET FULL WEATHERSTRIP <br />(1) - DOOR SWEEP <br />(1) -ALUMINUM THRESHOLD (ADA COMPLIANT) <br />(1) - RAINHOOD. RE: HEAD DETAIL <br />(1) - ASTRAGAL <br />(1) - FLOOR BOLT FOR SECONDARY LEAF <br />(1)-1.5",180 DEGREE PANORAMIC VIEWER <br />(1) - DOOR STRIKE COVER PLATE <br />HARDWARE SET # 2: (STOREFRONT DOOR) <br />(1) - SET SINGLE ACTING OFFSET PIVOT HINGES <br />(1) - DOOR CLOSER - NORTON 1601 (ADJUSTABLE FORCE) <br />(1) - MILL FINISH ALUMINUM THRESHOLD (FOR <br />OFFSET PIVOTAND OVERHEAD CLOSER) <br />(1) -ADAMS RITE MS+1890 DEADLOCK/ LATCH COMBINATION <br />(1) -ADAMS RITE 4590 LATCH PADDLE DEVICE <br />(1) -ADAMS RITE STANDARD LATCH STRIKE <br />(1) - CYLINDER - SCHLAGE (7PIN) MORTISE <br />(1) - CP II DOOR PUSH & CO-9 PULL #14 <br />(1) - SEALAIR WEATHERING SYSTEM & EPDM <br />BLADE SURFACE ATTACHED SWEEP STRIP. <br />(1) - STENCILLED NOTE: "DOOR TO REMAIN <br />UNLOCKED DURING STORE OPERATION" <br />HARDWARE SET # 3: (STOREFRONT DOOR) <br />(2) - SET SINGLE ACTING OFFSET PIVOT HINGES <br />(2) - DOOR CLOSER - NORTON 1601 (ADJUSTABLE FORCE) <br />(1) - MILL FINISH ALUMINUM THRESHOLD (FOR <br />OFFSET PIVOT AND OVERHEAD CLOSER) <br />(1) -ADAMS RITE MS+1890 DEADLOCK / LATCH COMBINATION <br />(1) -ADAMS RITE 4590 LATCH PADDLE DEVICE <br />(1) -ADAMS RITE STANDARD LATCH STRIKE <br />(1) - CYLINDER - SCHLAGE (7PIN) MORTISE <br />(2) - CP II DOOR PUSH & CO-9 PULL #14 <br />(1) - SEALAIR WEATHERING SYSTEM & EPDM <br />BLADE SURFACE ATTACHED SWEEP STRIP. <br />(1) - STENCILLED NOTE: "DOOR TO REMAIN <br />UNLOCKED DURING STORE OPERATION" <br />HARDWARE SET # 4: (RESTROOM DOOR) <br />(3) - HAGER 4-1/2" X 4-1/2" BUTT FULL MORTISE <br />HINGES NO. BB1191 (NRP). STAINLESS <br />STEEL HINGES W/ STAINLESS STEEL PINS <br />(1) - LOCKSET SCHLAGE AL40S "PRIVACY LOCK" <br />FINISH 626 (US 26D) SATIN CHROME <br />(1) - CLOSER - LCN NO.4040. STANDARD POWDER <br />COATALUMINUM FINISH. STANDARD PLASTIC <br />COVER. MOUNTED ON INSIDE OF ROOM <br />(1) - WALL STOP <br />(3) - SILENCERS <br />HARDWARE SET # 5: (STOCKROOM DOOR) <br />(2) -10.5" X 23" SEALED VISION PANEL WINDOW <br />EACH WITH RADIUS GASKET <br />(1) - SET OF REMOVABLE FULL PERIMETER SEALS <br />(2) - 8-3/4"HIGH STANDARD JAMB GUARDS <br />(1) - HARDWARE: CAM LIFT 90 DEG. X 90 DEG. <br />ALUM. <br />STORF7A'T <br />SYSTEM <br />ICV <br />ALUM. JAMB <br />BEYOND <br />ALUM. DOOR <br />RE: DOOR <br />SCHEDULE <br />4? ` <br />HEAD DETAIL - H2 <br />BELOW <br />MLVIVI. UVVI[ <br />RE: DOOR SCHEDULE <br />JAMB DETAIL - J2 <br />SILL DETAIL - S2 <br />ALUM. JAMB BEYOND <br />APPLIED SWEEP <br />ALUM. THRESHOLD <br />BY STOREFRONT <br />INSTALLER <br />EXISTING CONCRETE <br />FLOOR SLAB <br />EXISTING EXTR <br />SIDEWALK <br />Hardware Notes <br />1, ADJUST ALL CLOSERS TO A 5 LB MAX OPENING FORCE. <br />2. ALL LOCK & PASSAGE SETS TO BE SCHLAGE GRADE OR BETTER. <br />LOCKS NEED TO BE REKEYABLE. <br />3. ALL DOORS & HARDWARE TO COMPLY WITH NFPA 101-5-2.1.5. <br />4. ALL DOORS & HARDWARE TO COMPLY WITH THE FLORIDA <br />ACCESSIBILITY CODE & THE ADA FEDERAL REGULATION CODES, <br />UTILIZING A LEVER LATCH OR LOCKSET. <br />5. FINAL CORE PROCESS FOR LOCKSETS & KEYING SHALL BE: THE <br />SUBCONTRACTORS WILL INSTALL ALL DOORS, FRAMES, HARDWARE <br />& LOCKSETS. <br />DOUBLE 2X BLOCKING MIN. ATJA BS. PROVIDE EXACT <br />SUPPORT RECOMMENDED BY DOOR MANUFACTURER — <br />STEEL ANGLE MOUNTED <br />TED <br />TO HEADER AND JAMB <br />HARDWARE COVED. <br />TOP MOUNT NG <br />BRACKET <br />1/8" THICK <br />� t <br />ABS FACING _ <br />EXTRUSION - <br />V/ LOOP <br />SEAL <br />LOWER -- <br />PIVOT PIN <br />-3/4" STEEL' <br />JA1 B GOARD <br />HEAD DETAIL - H3 <br />1 y2" <br />JAMB DETAIL - J3 <br />SILL DETAIL - S3 <br />OUNTING DETAIL <br />OFT PIVOT HARDWARE <br />DOOR ROTATED FOR CLARITY <br />JAMB DETAIL - J4 <br />RE: WALL TYPES FOR <br />FRAMING, SHEATHING, & <br />INSULATION INFORMATION <br />CONT 2X WOOD BLOCKING <br />AT ENTIRE PERIMETER OF <br />ROUGH OPENING <br />SOLID WOOD DOOR <br />FRAME. PAINT INTERIOR <br />TO MATCH DOOR. EXTR <br />TO BE PAINT READY <br />RE: DOOR SCHEDULE <br />FLUSH HOLLOW CORE <br />WOOD DOOR <br />RE: DOOR SCHEDULE <br />RE: WALL TYPES FOR <br />FRAMING, SHEATHING, & <br />INSULATION INFORMATION <br />CONT 2X WOOD BLOCKING <br />AT ENTIRE PERIMETER OF <br />ROUGH OPENING <br />FLUSH HOLLOW CORE <br />WOOD DOOR <br />RE: DOOR SCHEDULE <br />SOLID WOOD DOOR <br />FRAME. PAINT INTERIOR <br />TO MATCH DOOR. EXTR <br />TO BE PAINT READY <br />RE: DOOR SCHEDULE <br />HC WOOD DOOR. RE: SCHED. <br />SOLID WOOD DOOR <br />FRAME (BEYOND) <br />COORDINATE UNDERCUT SIZE <br />WITH MECHANICAL PLANS <br />RE: FLOOR PLAN FOR <br />FINISH INFORMATION <br />O <br />O <br />O <br />O <br />U <br />�F3 <br />�a <br />§ <br />wa, <br />P <br />U <br />o <br />MI <br />_o <br />d _o <br />U <br />w <br />U- <br />0-4 <br />�+ <br />Ln�� <br />U <br />0 <br />0 <br />LU <br />CUQOo <br />.VJ <br />a <br />SUM <br />�Q� <br />Ewa <br />04 <br />L_ CID <br />�+Ma <br />Cn <br />E <br />0 <br />0 <br />L <br />0 U_ <br />No = <br />(U m <br />QU_ <br />... <br />M <br />LJL- CO <br />J <br />J <br />r Q <br />U_ CD - <br />U) C4 <br />0 .! . <br />kupappL <br />ti J <br />w <br />. J <br />AI--" 111T _ <br />00 <br />z <br />CU } <br />�Oa <br />v <br />o <br />0 <br />�—�N <br />a <br />- <br />11 <br />zo <br />W <br />J <br />Cal <br />}p� <br />z¢ <br />w <br />> IL <br />Uj <br />,I <br />91 <br />�4 <br />w <br />co <br />w <br />a <br />0 <br />o <br />LU <br />rnl <br />i <br />CD <br />oo <br />it <br />W <br />N <br />J <br />w <br />0 <br />a <br />zCn <br />o <br />M <br />o <br />z <br />N <br />N <br />m <br />O <br />W <br />W <br />1 <br />a <br />U <br />TENANT BUILD OUT <br />Al 03 i <br />-- <br />